Elimination of pneumothorax and hemothorax during placement of implantable venous access ports using ultrasound and fluoroscopic guidance

Author keywords

hemothorax; pneumothorax; port; ultrasound guidance; venous access

Indexed keywords

ADULT; ARTICLE; CENTRAL VENOUS CATHETER; FEMALE; FLUOROSCOPY; FOLLOW UP; HEALTH CARE COST; HEMATOTHORAX; HUMAN; IMPLANTABLE PORT SYSTEM; IMPLANTABLE VENOUS ACCESS PORT; INTENSIVE CARE; MAJOR CLINICAL STUDY; MALE; MEDICAL DEVICE COMPLICATION; MIDDLE AGED; PNEUMOTHORAX; PRIORITY JOURNAL; RETROSPECTIVE STUDY; THORAX RADIOGRAPHY; ULTRASOUND; VEIN CATHETERIZATION; CENTRAL VENOUS CATHETERIZATION; JUGULAR VEIN;

EID: 84892983979     PISSN: 17085381     EISSN: 1708539X     Source Type: Journal    
DOI: 10.1177/1708538112472279     Document Type: Article
Times cited : (6)

References (21)
  • 2
    • 23844513438 scopus 로고    scopus 로고
    • Randomized, controlled clinical trial of point-of-care limited ultrasonography assistance of central venous cannulation: The third Sonography Outcomes Assessment Program (SOAP-3) trial
    • Milling TJ,Rose J,Briggs WMet al.Randomized, controlled clinical trial of point-of-care limited ultrasonography assistance of central venous cannulation: The third Sonography Outcomes Assessment Program (SOAP-3) trial.Crit Care Med. 2005;33:1764-9.
    • (2005) Crit Care Med , vol.33 , pp. 1764-1769
    • Milling, T.J.1    Rose, J.2    Briggs, W.M.3
  • 3
    • 0029906824 scopus 로고    scopus 로고
    • Ultrasound guidance for placement of central venous catheters: a meta-analysis of the literature
    • Randolph AG,Cook DJ,Gonzales CAet al.Ultrasound guidance for placement of central venous catheters: a meta-analysis of the literature.Crit Care Med. 1996;24:2053-8.
    • (1996) Crit Care Med , vol.24 , pp. 2053-2058
    • Randolph, A.G.1    Cook, D.J.2    Gonzales, C.A.3
  • 4
    • 0025760828 scopus 로고
    • Ultrasound-guided cannulation of the internal jugular vein: a prospective, randomized study
    • Troianos CA,Jobes DR,Ellison N.Ultrasound-guided cannulation of the internal jugular vein: a prospective, randomized study.Anesth Analg. 1991;72:823-6.
    • (1991) Anesth Analg , vol.72 , pp. 823-826
    • Troianos, C.A.1    Jobes, D.R.2    Ellison, N.3
  • 5
    • 43349090817 scopus 로고    scopus 로고
    • Chest radiograph after central line placement under fluoroscopy: utility or futility?
    • Keckler SJ,Spilde TL,Ho Bet al.Chest radiograph after central line placement under fluoroscopy: utility or futility?.J Pediatr Surg. 2008;43:854-6.
    • (2008) J Pediatr Surg , vol.43 , pp. 854-856
    • Keckler, S.J.1    Spilde, T.L.2    Ho, B.3
  • 6
    • 33749665006 scopus 로고    scopus 로고
    • Real-time ultrasonographically-guided internal jugular vein catheterization in the emergency department increases success rates and reduces complications: a randomized, prospective study
    • Leung J,Duffy M,Finckh A.Real-time ultrasonographically-guided internal jugular vein catheterization in the emergency department increases success rates and reduces complications: a randomized, prospective study.Ann Emerg Med. 2006;48:540-7.
    • (2006) Ann Emerg Med , vol.48 , pp. 540-547
    • Leung, J.1    Duffy, M.2    Finckh, A.3
  • 7
    • 34249712832 scopus 로고    scopus 로고
    • Mechanical complications and malpositions of central venous cannulations by experienced operators. a prospective study of 1794 catheterizations in critically ill patients
    • Schummer W,Schummer C,Rose Net al.Mechanical complications and malpositions of central venous cannulations by experienced operators. a prospective study of 1794 catheterizations in critically ill patients.Intensive Care Med. 2007;33:1055-9.
    • (2007) Intensive Care Med , vol.33 , pp. 1055-1059
    • Schummer, W.1    Schummer, C.2    Rose, N.3
  • 9
    • 84941817891 scopus 로고
    • Central vein catheterization: failure and complication rates by three percutaneous approaches
    • Sznajder JI,Zveibil FR,Bitterman Het al.Central vein catheterization: failure and complication rates by three percutaneous approaches.Arch Intern Med. 1986;146:259-61.
    • (1986) Arch Intern Med , vol.146 , pp. 259-261
    • Sznajder, J.I.1    Zveibil, F.R.2    Bitterman, H.3
  • 11
    • 62349140390 scopus 로고    scopus 로고
    • Is routine postoperative chest X-ray necessary after fluoroscopic-guided subclavian central venous port placement?
    • Brown JR,Slomski C,Saxe AW.Is routine postoperative chest X-ray necessary after fluoroscopic-guided subclavian central venous port placement?.J Am Coll Surg. 2009;208:517-9.
    • (2009) J Am Coll Surg , vol.208 , pp. 517-519
    • Brown, J.R.1    Slomski, C.2    Saxe, A.W.3
  • 12
    • 0018132491 scopus 로고
    • Indications, management. and complications of percutaneous subclavian catheters: an audit
    • Herbst CA.Indications, management. and complications of percutaneous subclavian catheters: an audit.Arch Surg. 1978;113:1421-5.
    • (1978) Arch Surg , vol.113 , pp. 1421-1425
    • Herbst, C.A.1
  • 13
    • 0015012577 scopus 로고
    • Subclavian vein catheterizations: a prospective study: non-infectious complications
    • Bernard RW,Stahl WM.Subclavian vein catheterizations: a prospective study: non-infectious complications.Ann Surg. 1971;173:184-90.
    • (1971) Ann Surg , vol.173 , pp. 184-190
    • Bernard, R.W.1    Stahl, W.M.2
  • 14
    • 0031929958 scopus 로고    scopus 로고
    • Are routine chest radiographs necessary after image-guided placement of internal jugular central venous access devices?
    • Chang TC,Funaki B,Szymski GX.Are routine chest radiographs necessary after image-guided placement of internal jugular central venous access devices?.AJR. 1998;170:335-7.
    • (1998) AJR , vol.170 , pp. 335-337
    • Chang, T.C.1    Funaki, B.2    Szymski, G.X.3
  • 15
    • 0025954391 scopus 로고
    • Subclavian vein catheterization in critically ill children: analysis of 322 cannulations
    • Casado-Flores J,Valdivielso-Serna A,Perez-Jurado Let al.Subclavian vein catheterization in critically ill children: analysis of 322 cannulations.Intensive Care Med. 1991;17:350-4.
    • (1991) Intensive Care Med , vol.17 , pp. 350-354
    • Casado-Flores, J.1    Valdivielso-Serna, A.2    Perez-Jurado, L.3
  • 16
    • 0030070147 scopus 로고    scopus 로고
    • Outcome of tunneled hemodialysis catheters placed by radiologists
    • Lund GB,Trerotola SO,Scheel PFet al.Outcome of tunneled hemodialysis catheters placed by radiologists.Radiology. 1996;198:467-72.
    • (1996) Radiology , vol.198 , pp. 467-472
    • Lund, G.B.1    Trerotola, S.O.2    Scheel, P.F.3
  • 17
    • 0031003645 scopus 로고    scopus 로고
    • Outcome of tunneled hemodialysis catheters placed via the right internal jugular vein by interventional radiologists
    • Trerotola SO,Johnson MS,Harris Viet al.Outcome of tunneled hemodialysis catheters placed via the right internal jugular vein by interventional radiologists.Radiology. 1997;203:489-95.
    • (1997) Radiology , vol.203 , pp. 489-495
    • Trerotola, S.O.1    Johnson, M.S.2    Harris, V.3
  • 18
    • 63449124922 scopus 로고    scopus 로고
    • College's Committee on Perioperative Care
    • College's Committee on Perioperative Care.Bull Am Coll Surg. 2008;93:35-6.
    • (2008) Bull Am Coll Surg , vol.93 , pp. 35-36
  • 19
    • 0021358874 scopus 로고
    • Doppler localization of the internal jugular vein facilitates central venous cannulation
    • Legler D,Nugent M.Doppler localization of the internal jugular vein facilitates central venous cannulation.Anesthesiology. 1984;60:481-2.
    • (1984) Anesthesiology , vol.60 , pp. 481-482
    • Legler, D.1    Nugent, M.2
  • 20
    • 0024980270 scopus 로고
    • Cost effectiveness as a criterion for Medicare coverage
    • Leaf A.Cost effectiveness as a criterion for Medicare coverage.N Engl J Med. 1989;321:898-900.
    • (1989) N Engl J Med , vol.321 , pp. 898-900
    • Leaf, A.1
  • 21
    • 0035229184 scopus 로고    scopus 로고
    • Routine chest X-rays after insertion of implantable long-term venous catheters: necessary or not?
    • Guth AA.Routine chest X-rays after insertion of implantable long-term venous catheters: necessary or not?.Am Surg. 2001;67:26-9.
    • (2001) Am Surg , vol.67 , pp. 26-29
    • Guth, A.A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.