메뉴 건너뛰기




Volumn 107, Issue 3, 2014, Pages 261-268

New approach to 'top-and-bottom' whole blood separation using the multiunit TACSI WB system: Quality of blood components

Author keywords

Blood components; Separation system; Storage study; TACSI WB

Indexed keywords

2,3 DIPHOSPHOGLYCERIC ACID; ADENOSINE TRIPHOSPHATE; ALBUMIN; ANTITHROMBIN III; BLOOD CLOTTING FACTOR 10; BLOOD CLOTTING FACTOR 5; BLOOD CLOTTING FACTOR 7; BLOOD CLOTTING FACTOR 8; BLOOD CLOTTING FACTOR 9; D DIMER; FIBRINOGEN; GLUCOSE; HEMOGLOBIN; IMMUNOGLOBULIN A; IMMUNOGLOBULIN G; IMMUNOGLOBULIN M; POTASSIUM; PROTEIN; PROTEIN C; PROTEIN S; PROTHROMBIN; THROMBOCYTE CONCENTRATE;

EID: 84924968103     PISSN: 00429007     EISSN: 14230410     Source Type: Journal    
DOI: 10.1111/vox.12159     Document Type: Article
Times cited : (6)

References (22)
  • 1
    • 0030909270 scopus 로고    scopus 로고
    • A Comparative Analysis of Different Methods for Routine Blood Component Preparation
    • Heaton L, Rebulla P, Pappalettera M, et al.: A Comparative Analysis of Different Methods for Routine Blood Component Preparation. Transfus Med Rev 1997; 11:116-129
    • (1997) Transfus Med Rev , vol.11 , pp. 116-129
    • Heaton, L.1    Rebulla, P.2    Pappalettera, M.3
  • 2
    • 0030857585 scopus 로고    scopus 로고
    • Prestorage leukocyte reduction with in-line filtration of whole blood: evaluation of red cells and plasma storage
    • Rapaille A, Moore G, Siquet J, et al.: Prestorage leukocyte reduction with in-line filtration of whole blood: evaluation of red cells and plasma storage. Vox Sang 1997; 73:28-35
    • (1997) Vox Sang , vol.73 , pp. 28-35
    • Rapaille, A.1    Moore, G.2    Siquet, J.3
  • 3
    • 0025245525 scopus 로고
    • Comparison of a conventional quadruple-bag system with a 'Top-and-Bottom' system for blood processing
    • Pietersz RNI, Dekker WJA, Reesink HW: Comparison of a conventional quadruple-bag system with a 'Top-and-Bottom' system for blood processing. Vox Sang 1990; 59:205-208
    • (1990) Vox Sang , vol.59 , pp. 205-208
    • Pietersz, R.N.I.1    Dekker, W.J.A.2    Reesink, H.W.3
  • 4
    • 0024212721 scopus 로고
    • The bottom and top system: a new technique for blood component preparation and storage
    • Claes F, Eriksson L, Hedlund K, et al.: The bottom and top system: a new technique for blood component preparation and storage. Vox Sang 1988; 55:211-217
    • (1988) Vox Sang , vol.55 , pp. 211-217
    • Claes, F.1    Eriksson, L.2    Hedlund, K.3
  • 5
    • 0024352159 scopus 로고
    • Storage of leukocyte-poor red cell concentrates: filtration in a closed system using connection device
    • Pietersz RNI, Reesink HW, de Korte D, et al.: Storage of leukocyte-poor red cell concentrates: filtration in a closed system using connection device. Vox Sang 1989; 57:29-36
    • (1989) Vox Sang , vol.57 , pp. 29-36
    • Pietersz, R.N.I.1    Reesink, H.W.2    de Korte, D.3
  • 6
    • 77951674132 scopus 로고    scopus 로고
    • Conversion to the buffy coat method and quality of frozen plasma derived from whole blood donations in Canada
    • Sheffield WP, Bhakta V, Jenkins C, et al.: Conversion to the buffy coat method and quality of frozen plasma derived from whole blood donations in Canada. Transfusion 2010; 50:1043-1049
    • (2010) Transfusion , vol.50 , pp. 1043-1049
    • Sheffield, W.P.1    Bhakta, V.2    Jenkins, C.3
  • 7
    • 0033044701 scopus 로고    scopus 로고
    • Automated separation of whole blood in Top and Bottom bags into components using the compomat G4
    • Van der Meer PF, Pietersz RNI, Hinloopen B, et al.: Automated separation of whole blood in Top and Bottom bags into components using the compomat G4. Vox Sang 1999; 76:90-99
    • (1999) Vox Sang , vol.76 , pp. 90-99
    • Van der Meer, P.F.1    Pietersz, R.N.I.2    Hinloopen, B.3
  • 8
    • 57249103727 scopus 로고    scopus 로고
    • Blood components produced from whole blood using the Atreus processing system
    • Thomas S, Beard M, Garwood M, et al.: Blood components produced from whole blood using the Atreus processing system. Transfusion 2008; 48:2515-2524
    • (2008) Transfusion , vol.48 , pp. 2515-2524
    • Thomas, S.1    Beard, M.2    Garwood, M.3
  • 9
    • 84882448109 scopus 로고    scopus 로고
    • Evaluation of the quality of blood components obtained after automated separation of whole blood by a new multiunit processor
    • Lagerberg JW, Salado-Jimena JA, Löf H, et al.: Evaluation of the quality of blood components obtained after automated separation of whole blood by a new multiunit processor. Transfusion 2013; 53:1798-1807
    • (2013) Transfusion , vol.53 , pp. 1798-1807
    • Lagerberg, J.W.1    Salado-Jimena, J.A.2    Löf, H.3
  • 10
    • 84884291652 scopus 로고    scopus 로고
    • Evaluation of the quality of blood components prepared using the Reveos automated blood processing system
    • Johnson L, Winter K, Kwok M, et al.: Evaluation of the quality of blood components prepared using the Reveos automated blood processing system. Vox Sang 2013; 105:225-235
    • (2013) Vox Sang , vol.105 , pp. 225-235
    • Johnson, L.1    Winter, K.2    Kwok, M.3
  • 11
    • 77958483309 scopus 로고    scopus 로고
    • Storage of Buffy-Coat-derived platelets in additive solutions; in vitro effects on platelets prepared by the novel TACSI system and stored in plastic containers with different gas permeability
    • Sandgren P, Hild M, Sjöfin A, et al.: Storage of Buffy-Coat-derived platelets in additive solutions; in vitro effects on platelets prepared by the novel TACSI system and stored in plastic containers with different gas permeability. Vox Sang 2010; 99:341-347
    • (2010) Vox Sang , vol.99 , pp. 341-347
    • Sandgren, P.1    Hild, M.2    Sjöfin, A.3
  • 12
    • 84890785990 scopus 로고    scopus 로고
    • Quality assessment of buffy-coat-derived leucopleted platelet concentrates in PAS-plasma, prepared by the OrbiSac or TACSI automated system
    • Plaza EM, Céspedes P, Fernandez H, et al.: Quality assessment of buffy-coat-derived leucopleted platelet concentrates in PAS-plasma, prepared by the OrbiSac or TACSI automated system. Vox Sang 2013; 106:38-44
    • (2013) Vox Sang , vol.106 , pp. 38-44
    • Plaza, E.M.1    Céspedes, P.2    Fernandez, H.3
  • 13
    • 0002427925 scopus 로고
    • A method for determination of hemoglobin in plasma by near-ultraviolet spectrophotometry
    • Harboe M: A method for determination of hemoglobin in plasma by near-ultraviolet spectrophotometry. Scand J Clin Lab Invest 1959; 11:66-70
    • (1959) Scand J Clin Lab Invest , vol.11 , pp. 66-70
    • Harboe, M.1
  • 14
    • 44849127632 scopus 로고    scopus 로고
    • Prolonged maintenance of 2,3 diphosphoglycerate acid and adenosine triphosphate in red blood cells during storage
    • de Korte D, Kleine M, Korsten HG, et al.: Prolonged maintenance of 2, 3 diphosphoglycerate acid and adenosine triphosphate in red blood cells during storage. Transfusion 2008; 48:1081-1089
    • (2008) Transfusion , vol.48 , pp. 1081-1089
    • de Korte, D.1    Kleine, M.2    Korsten, H.G.3
  • 16
    • 67749131149 scopus 로고    scopus 로고
    • Storage of whole blood overnight in different blood bags preceding preparation of blood components: in vitro effects on red blood cells
    • Gulliksson H, van der Peer PF: Storage of whole blood overnight in different blood bags preceding preparation of blood components: in vitro effects on red blood cells. Blood Transfus 2009; 7:210-215
    • (2009) Blood Transfus , vol.7 , pp. 210-215
    • Gulliksson, H.1    van der Peer, P.F.2
  • 17
    • 84863996508 scopus 로고    scopus 로고
    • Repeated short-term warming of red blood cell concentrates has minimal effect on their quality
    • Thomas S, Hancock V, Cardigan R: Repeated short-term warming of red blood cell concentrates has minimal effect on their quality. Vox Sang 2012; 103:113-121
    • (2012) Vox Sang , vol.103 , pp. 113-121
    • Thomas, S.1    Hancock, V.2    Cardigan, R.3
  • 18
    • 78651388261 scopus 로고    scopus 로고
    • Evaluation of overnight hold of whole blood at room temperature before component processing: effect of red blood cell (RBC) additive solutions on in vitro RBC measures
    • Van der Meer PF, Cancelas JA, Cardigan R, et al.: Evaluation of overnight hold of whole blood at room temperature before component processing: effect of red blood cell (RBC) additive solutions on in vitro RBC measures. Transfusion 2011; 51(Suppl):15s-24s
    • (2011) Transfusion , vol.51 , pp. 15s-24s
    • Van der Meer, P.F.1    Cancelas, J.A.2    Cardigan, R.3
  • 19
    • 0348134868 scopus 로고    scopus 로고
    • Modified formulation of CPDA for storage of whole blood, and of SAGM for storage of red blood cells, to maintain the concentration of 2,3-diphosphoglycerate
    • Kurup PA, Arun P, Gayathri NS, et al.: Modified formulation of CPDA for storage of whole blood, and of SAGM for storage of red blood cells, to maintain the concentration of 2, 3-diphosphoglycerate. Vox Sang 2003; 85:253-261
    • (2003) Vox Sang , vol.85 , pp. 253-261
    • Kurup, P.A.1    Arun, P.2    Gayathri, N.S.3
  • 20
    • 35448940128 scopus 로고    scopus 로고
    • Overnight storage of whole blood: a comparison of two designs of butane-1,4-Diol cooling plates
    • Van Der Meer PF, Pietersz RN: Overnight storage of whole blood: a comparison of two designs of butane-1, 4-Diol cooling plates. Transfusion 2007; 47:2038-2043
    • (2007) Transfusion , vol.47 , pp. 2038-2043
    • Van Der Meer, P.F.1    Pietersz, R.N.2
  • 21
    • 75749108236 scopus 로고    scopus 로고
    • Quality of methylene blue-treated fresh-frozen plasma stored up to 27 months
    • Moog R, Reichenberg S, Hoburg A, et al.: Quality of methylene blue-treated fresh-frozen plasma stored up to 27 months. Transfusion 2010; 50:516-518
    • (2010) Transfusion , vol.50 , pp. 516-518
    • Moog, R.1    Reichenberg, S.2    Hoburg, A.3
  • 22
    • 66049121363 scopus 로고    scopus 로고
    • Automatisation de la préparation des produits sanguins labiles
    • Tardivel R, Bois S, Vignoli C, et al.: Automatisation de la préparation des produits sanguins labiles. Transfus Clin Biol 2009; 16:175-178
    • (2009) Transfus Clin Biol , vol.16 , pp. 175-178
    • Tardivel, R.1    Bois, S.2    Vignoli, C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.