메뉴 건너뛰기




Volumn 99, Issue 4, 2010, Pages 341-347

Storage of Buffy-coat-derived platelets in additive solutions: In vitro effects on platelets prepared by the novel TACSI system and stored in plastic containers with different gas permeability

Author keywords

Additive solutions; Platelets; Storage

Indexed keywords

ADENOSINE TRIPHOSPHATE; CITRIC ACID; PLASTICIZER; POLYVINYLCHLORIDE;

EID: 77958483309     PISSN: 00429007     EISSN: 14230410     Source Type: Journal    
DOI: 10.1111/j.1423-0410.2010.01364.x     Document Type: Article
Times cited : (23)

References (19)
  • 1
    • 34547595111 scopus 로고    scopus 로고
    • Platelet transfusions
    • Stroncek DF, Rebulla P: Platelet transfusions, Lancet, 2007; 370:427-438
    • (2007) Lancet , vol.370 , pp. 427-438
    • Stroncek, D.F.1    Rebulla, P.2
  • 2
    • 17044414569 scopus 로고    scopus 로고
    • Automated preparation of platelet concentrates from pooled buffy coats: in vitro studies and experiences with the OrbiSac system
    • Larsson S, Sandgren P, Sjodin A, et al. : Automated preparation of platelet concentrates from pooled buffy coats: in vitro studies and experiences with the OrbiSac system, Transfusion, 2005; 45:743-751
    • (2005) Transfusion , vol.45 , pp. 743-751
    • Larsson, S.1    Sandgren, P.2    Sjodin, A.3
  • 3
    • 41149112105 scopus 로고    scopus 로고
    • Storage of platelet concentrates from pooled buffy coats made of fresh and overnight-stored whole blood processed on the novel Atreus 2C+ system: in vitro study
    • Sandgren P, Callaert M, Shanwell A, et al. : Storage of platelet concentrates from pooled buffy coats made of fresh and overnight-stored whole blood processed on the novel Atreus 2C+ system: in vitro study, Transfusion, 2008; 48:688-696
    • (2008) Transfusion , vol.48 , pp. 688-696
    • Sandgren, P.1    Callaert, M.2    Shanwell, A.3
  • 4
    • 0031938407 scopus 로고    scopus 로고
    • A multi-laboratory evaluation of in vitro platelet assays: the tests for extent of shape change and response to hypotonic shock. Biomedical Excellence for Safer Transfusion Working Party of the International Society of Blood Transfusion
    • Holme S, Moroff G, Murphy S: A multi-laboratory evaluation of in vitro platelet assays: the tests for extent of shape change and response to hypotonic shock. Biomedical Excellence for Safer Transfusion Working Party of the International Society of Blood Transfusion, Transfusion, 1998; 38:31-40
    • (1998) Transfusion , vol.38 , pp. 31-40
    • Holme, S.1    Moroff, G.2    Murphy, S.3
  • 5
    • 0031014767 scopus 로고    scopus 로고
    • The expression of p-selectin during collection, processing, and storage of platelet concentrates: relationship to loss of in vivo viability
    • Holme S, Sweeney JD, Sawyer S, et al. : The expression of p-selectin during collection, processing, and storage of platelet concentrates: relationship to loss of in vivo viability, Transfusion, 1997; 37:12-17
    • (1997) Transfusion , vol.37 , pp. 12-17
    • Holme, S.1    Sweeney, J.D.2    Sawyer, S.3
  • 7
    • 0042344865 scopus 로고    scopus 로고
    • Defining the optimal storage conditions for the long-term storage of platelets
    • Gulliksson H: Defining the optimal storage conditions for the long-term storage of platelets, Transfus Med Rev, 2003; 17:209-215
    • (2003) Transfus Med Rev , vol.17 , pp. 209-215
    • Gulliksson, H.1
  • 8
    • 0030975027 scopus 로고    scopus 로고
    • Improvement of platelet storage conditions by using new polyolefin containers
    • De Wildt-Eggen J, Schrijver JG, Bouter-Valk HJ, et al. : Improvement of platelet storage conditions by using new polyolefin containers, Transfusion, 1997; 37:476-481
    • (1997) Transfusion , vol.37 , pp. 476-481
    • De Wildt-Eggen, J.1    Schrijver, J.G.2    Bouter-Valk, H.J.3
  • 9
    • 0026002898 scopus 로고
    • Storage of platelets in a new plastic container. Polyvinyl chloride plasticized with butyryl-n-trihexyl citrate
    • Gulliksson H, Shanwell A, Wikman A, et al. : Storage of platelets in a new plastic container. Polyvinyl chloride plasticized with butyryl-n-trihexyl citrate, Vox Sang, 1991; 61:165-170
    • (1991) Vox Sang , vol.61 , pp. 165-170
    • Gulliksson, H.1    Shanwell, A.2    Wikman, A.3
  • 10
    • 0035437322 scopus 로고    scopus 로고
    • Leucoreduced platelet concentrates in additive solution: an evaluation of filters and storage containers
    • Van Der Meer P, Pietersz R, Reesink H: Leucoreduced platelet concentrates in additive solution: an evaluation of filters and storage containers, Vox Sang, 2001; 81:102-107
    • (2001) Vox Sang , vol.81 , pp. 102-107
    • Van Der Meer, P.1    Pietersz, R.2    Reesink, H.3
  • 11
    • 33845634805 scopus 로고    scopus 로고
    • Sterilization method of platelet storage containers affects in vitro parameters
    • Van Der Meer PF, Pietersz RN: Sterilization method of platelet storage containers affects in vitro parameters, Vox Sang, 2007; 92:32-36
    • (2007) Vox Sang , vol.92 , pp. 32-36
    • Van Der Meer, P.F.1    Pietersz, R.N.2
  • 12
    • 0030068146 scopus 로고    scopus 로고
    • A multicenter inspection of the swirling phenomenon in platelet concentrates prepared in routine practice. Biomedical Excellence for Safer Transfusion (BEST) Working Party of the International Society of Blood Transfusion
    • Bertolini F, Murphy S: A multicenter inspection of the swirling phenomenon in platelet concentrates prepared in routine practice. Biomedical Excellence for Safer Transfusion (BEST) Working Party of the International Society of Blood Transfusion, Transfusion, 1996; 36:128-132
    • (1996) Transfusion. , vol.36 , pp. 128-132
    • Bertolini, F.1    Murphy, S.2
  • 13
    • 0027976919 scopus 로고
    • Validation of use of the Nageotte hemocytometer to count low levels of white cells in white cell-reduced platelet components
    • Moroff G, Eich J, Dabay M: Validation of use of the Nageotte hemocytometer to count low levels of white cells in white cell-reduced platelet components, Transfusion, 1994; 34:35-38
    • (1994) Transfusion , vol.34 , pp. 35-38
    • Moroff, G.1    Eich, J.2    Dabay, M.3
  • 14
    • 11144356882 scopus 로고    scopus 로고
    • Platelet storage solution affects on the accuracy of laboratory tests for platelet function: a multi-laboratory study
    • VandenBroeke T, Dumont LJ, Hunter S, et al. : Platelet storage solution affects on the accuracy of laboratory tests for platelet function: a multi-laboratory study, Vox Sang, 2004; 86:183-188
    • (2004) Vox Sang , vol.86 , pp. 183-188
    • VandenBroeke, T.1    Dumont, L.J.2    Hunter, S.3
  • 15
    • 0033935718 scopus 로고    scopus 로고
    • Use of firefly luciferase in ATP-related assays of biomass, enzymes, and metabolites
    • Lundin A: Use of firefly luciferase in ATP-related assays of biomass, enzymes, and metabolites, Methods Enzymol, 2000; 305:346-370
    • (2000) Methods Enzymol , vol.305 , pp. 346-370
    • Lundin, A.1
  • 16
    • 70449290511 scopus 로고
    • A routine method for the estimation of lactic dehydrogenase activity
    • King J: A routine method for the estimation of lactic dehydrogenase activity, J Med Lab Technol, 1959; 16:265-272
    • (1959) J Med Lab Technol , vol.16 , pp. 265-272
    • King, J.1
  • 17
    • 0023511467 scopus 로고
    • Platelet storage lesion in second-generation containers: correlation with platelet ATP levels
    • Holme S, Heaton WA, Courtright M: Platelet storage lesion in second-generation containers: correlation with platelet ATP levels, Vox Sang, 1987; 53:214-220
    • (1987) Vox Sang , vol.53 , pp. 214-220
    • Holme, S.1    Heaton, W.A.2    Courtright, M.3
  • 18
    • 77949410279 scopus 로고    scopus 로고
    • Storage of buffy-coat-derived platelets in additive solutions: in vitro effects on platelets stored in reformulated PAS supplied by a 20% plasma carry-over
    • Sandgren P, Mayaudon V, Payrat JM, et al. : Storage of buffy-coat-derived platelets in additive solutions: in vitro effects on platelets stored in reformulated PAS supplied by a 20% plasma carry-over, Vox Sang, 2009; 98:415-422
    • (2009) Vox Sang , vol.98 , pp. 415-422
    • Sandgren, P.1    Mayaudon, V.2    Payrat, J.M.3
  • 19
    • 52049116925 scopus 로고    scopus 로고
    • Flow cytometric measurement of CD62P (P-selectin) expression on platelets: a multicenter optimization and standardization effort
    • Curvers J, De Wildt-Eggen J, Heeremans J, et al. : Flow cytometric measurement of CD62P (P-selectin) expression on platelets: a multicenter optimization and standardization effort, Transfusion, 2008; 48:1439-1446
    • (2008) Transfusion , vol.48 , pp. 1439-1446
    • Curvers, J.1    De Wildt-Eggen, J.2    Heeremans, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.