-
1
-
-
0024453449
-
Adaptive technique for high-definition MR imaging of moving structures
-
Ehman RL, Felmlee JP. Adaptive technique for high-definition MR imaging of moving structures. Radiology 1989;173:255-263.
-
(1989)
Radiology
, vol.173
, pp. 255-263
-
-
Ehman, R.L.1
Felmlee, J.P.2
-
2
-
-
0025040013
-
Adaptive technique for three-dimensional MR imaging of moving structures
-
Korin HW, Felmlee JP, Ehman RL, Riederer SJ. Adaptive technique for three-dimensional MR imaging of moving structures. Radiology 1990;177:217-221.
-
(1990)
Radiology
, vol.177
, pp. 217-221
-
-
Korin, H.W.1
Felmlee, J.P.2
Ehman, R.L.3
Riederer, S.J.4
-
3
-
-
0028886141
-
Orbital navigator echoes for motion measurements in magnetic resonance imaging
-
Fu ZW, Wang Y, Grimm RC, Rossman PJ, Felmlee JP, Riederer SJ, Ehman RL. Orbital navigator echoes for motion measurements in magnetic resonance imaging. Magn Reson Med 1995;34:746-753.
-
(1995)
Magn Reson Med
, vol.34
, pp. 746-753
-
-
Fu, Z.W.1
Wang, Y.2
Grimm, R.C.3
Rossman, P.J.4
Felmlee, J.P.5
Riederer, S.J.6
Ehman, R.L.7
-
4
-
-
0036136070
-
Spherical navigator echoes for full 3D rigid body motion measurement in MRI
-
Welch EB, Manduca A, Grimm RC, Ward HA, Jack CR Jr. Spherical navigator echoes for full 3D rigid body motion measurement in MRI. Magn Reson Med 2002;47:32-41.
-
(2002)
Magn Reson Med
, vol.47
, pp. 32-41
-
-
Welch, E.B.1
Manduca, A.2
Grimm, R.C.3
Ward, H.A.4
Jack, C.R.J.R.5
-
5
-
-
0028030441
-
Analysis and correction of motion artifacts in diffusion weighted imaging
-
Anderson AW, Gore JC. Analysis and correction of motion artifacts in diffusion weighted imaging. Magn Reson Med 1994;32:379-387.
-
(1994)
Magn Reson Med
, vol.32
, pp. 379-387
-
-
Anderson, A.W.1
Gore, J.C.2
-
6
-
-
0032754594
-
Motion correction with PROPELLER MRI: Application to head motion and free-breathing cardiac imaging
-
Pipe JG. Motion correction with PROPELLER MRI: application to head motion and free-breathing cardiac imaging. Magn Reson Med 1999;42:963-969.
-
(1999)
Magn Reson Med
, vol.42
, pp. 963-969
-
-
Pipe, J.G.1
-
7
-
-
0034765483
-
A quantitative comparison of motion detection algorithms in fMRI
-
Ardekani BA, Bachman AH, Helpern JA. A quantitative comparison of motion detection algorithms in fMRI. Magn Reson Imaging 2001; 19:959-963.
-
(2001)
Magn Reson Imaging
, vol.19
, pp. 959-963
-
-
Ardekani, B.A.1
Bachman, A.H.2
Helpern, J.A.3
-
8
-
-
33846167110
-
Augmented generalized SENSE reconstruction to correct for rigid body motion
-
Bammer R, Aksoy M, Liu C. Augmented generalized SENSE reconstruction to correct for rigid body motion. Magn Reson Med 2007;57:90-102.
-
(2007)
Magn Reson Med
, vol.57
, pp. 90-102
-
-
Bammer, R.1
Aksoy, M.2
Liu, C.3
-
9
-
-
0031283439
-
Automatic correction of motion artifacts in magnetic resonance images using an entropy focus criterion
-
Atkinson D, Hill DL, Stoyle PN, Summers PE, Keevil SF. Automatic correction of motion artifacts in magnetic resonance images using an entropy focus criterion. IEEE Trans Med Imaging 1997;16:903-910.
-
(1997)
IEEE Trans Med Imaging
, vol.16
, pp. 903-910
-
-
Atkinson, D.1
Hill, D.L.2
Stoyle, P.N.3
Summers, P.E.4
Keevil, S.F.5
-
10
-
-
0028944350
-
Spatial-frequencytuned markers and adaptive correction for rotational motion
-
Korin HW, Felmlee JP, Riederer SJ, Ehman RL Spatial-frequencytuned markers and adaptive correction for rotational motion. Magn Reson Med 1995;33:663-669.
-
(1995)
Magn Reson Med
, vol.33
, pp. 663-669
-
-
Korin, H.W.1
Felmlee, J.P.2
Riederer, S.J.3
Ehman, R.L.4
-
11
-
-
0029774047
-
Real-time adaptive motion correction in functional MRI
-
Lee CC, Jack CR Jr, Grimm RC, Rossman PJ, Felmlee JP, Ehman RL, Riederer SJ. Real-time adaptive motion correction in functional MRI. Magn Reson Med 1996;36:436-444.
-
(1996)
Magn Reson Med
, vol.36
, pp. 436-444
-
-
Lee, C.C.1
Jack, C.R.2
Grimm, R.C.3
Rossman, P.J.4
Felmlee, J.P.5
Ehman, R.L.6
Riederer, S.J.7
-
12
-
-
0031933419
-
A prospective approach to correct for inter-image head rotation in fMRI
-
Lee CC, Grimm RC, Manduca A, Felmlee JP, Ehman RL, Riederer SJ, Jack CR Jr. A prospective approach to correct for inter-image head rotation in fMRI. Magn Reson Med 1998;39:234-243.
-
(1998)
Magn Reson Med
, vol.39
, pp. 234-243
-
-
Lee, C.C.1
Grimm, R.C.2
Manduca, A.3
Felmlee, J.P.4
Ehman, R.L.5
Riederer, S.J.6
Jack, C.R.J.R.7
-
14
-
-
0034092614
-
Prospective multiaxial motion correction for fMRI
-
Ward HA, Riederer SJ, Grimm RC, Ehman RL, Felmlee JP, Jack CR Jr. Prospective multiaxial motion correction for fMRI. Magn Reson Med 2000;43:459-469.
-
(2000)
Magn Reson Med
, vol.43
, pp. 459-469
-
-
Ward, H.A.1
Riederer, S.J.2
Grimm, R.C.3
Ehman, R.L.4
Felmlee, J.P.5
Jack, C.R.J.R.6
-
15
-
-
33750610656
-
Real-time rigid body motion correction and shimming using cloverleaf navigators
-
van der Kouwe AJ, Benner T, Dale AM. Real-time rigid body motion correction and shimming using cloverleaf navigators. Magn Reson Med 2006;56:1019-1032.
-
(2006)
Magn Reson Med
, vol.56
, pp. 1019-1032
-
-
Van Der Kouwe, A.J.1
Benner, T.2
Dale, A.M.3
-
16
-
-
73349139471
-
PROMO: Real-time prospective motion correction in MRI using image-based tracking
-
White N, Roddey C, Shankaranarayanan A, Han E, Rettmann D, Santos J, Kuperman J, Dale A. PROMO: real-time prospective motion correction in MRI using image-based tracking. Magn Reson Med 2010;63:91-105.
-
(2010)
Magn Reson Med
, vol.63
, pp. 91-105
-
-
White, N.1
Roddey, C.2
Shankaranarayanan, A.3
Han, E.4
Rettmann, D.5
Santos, J.6
Kuperman, J.7
Dale, A.8
-
17
-
-
0033822261
-
Prospective acquisition correction for head motion with image-based tracking for real-time fMRI
-
Thesen S, Heid O, Mueller E, Schad LR. Prospective acquisition correction for head motion with image-based tracking for real-time fMRI. Magn Reson Med 2000;44:457-465.
-
(2000)
Magn Reson Med
, vol.44
, pp. 457-465
-
-
Thesen, S.1
Heid, O.2
Mueller, E.3
Schad, L.R.4
-
18
-
-
33744908028
-
Magnetic resonance imaging of freely moving objects: Prospective real-time motion correction using an external optical motion tracking system
-
Zaitsev M, Dold C, Sakas G, Hennig J, Speck O. Magnetic resonance imaging of freely moving objects: prospective real-time motion correction using an external optical motion tracking system. Neuroimage 2006;31:1038-1050.
-
(2006)
Neuroimage
, vol.31
, pp. 1038-1050
-
-
Zaitsev, M.1
Dold, C.2
Sakas, G.3
Hennig, J.4
Speck, O.5
-
19
-
-
70349632622
-
Prospective head-movement correction for highresolution MRI using an in-bore optical tracking system
-
Qin L, van Gelderen P, Derbyshire JA, Jin F, Lee J, de Zwart JA, Tao Y, Duyn JH. Prospective head-movement correction for highresolution MRI using an in-bore optical tracking system. Magn Reson Med 2009;62:924-934.
-
(2009)
Magn Reson Med
, vol.62
, pp. 924-934
-
-
Qin, L.1
Van Gelderen, P.2
Derbyshire, J.A.3
Jin, F.4
Lee, J.5
De Zwart, J.A.6
Tao, Y.7
Duyn, J.H.8
-
20
-
-
84870937226
-
An embedded optical tracking system for motion-corrected magnetic resonance imaging at 7T
-
Schulz J, Siegert T, Reimer E, Labadie C, Maclaren J, HerbstM, Zaitsev M, Turner R. An embedded optical tracking system for motion-corrected magnetic resonance imaging at 7T.MAGMA2012;25:443-453.
-
(2012)
MAGMA
, vol.25
, pp. 443-453
-
-
Schulz, J.1
Siegert, T.2
Reimer, E.3
Labadie, C.4
Maclaren, J.5
Herbst, M.6
Zaitsev, M.7
Turner, R.8
-
21
-
-
84868673863
-
Measurement and correction of microscopic head motion during magnetic resonance imaging of the brain
-
Maclaren J, Armstrong BS, Barrows RT, et al. Measurement and correction of microscopic head motion during magnetic resonance imaging of the brain. PLoS One 2012;7:e48088.
-
(2012)
PLoS One
, vol.7
, pp. e48088
-
-
Maclaren, J.1
Armstrong, B.S.2
Barrows, R.T.3
-
22
-
-
80052158364
-
Self-encoded marker for optical prospective head motion correction in MRI
-
Forman C, Aksoy M, Hornegger J, Bammer R. Self-encoded marker for optical prospective head motion correction in MRI. Med Image Anal 2011;15:708-719.
-
(2011)
Med Image Anal
, vol.15
, pp. 708-719
-
-
Forman, C.1
Aksoy, M.2
Hornegger, J.3
Bammer, R.4
-
23
-
-
0002077912
-
Rapid 3D tracking of small RF coils
-
Montreal, Canada
-
Ackerman JL, Offutt MC, Buxton RB, Brady TJ.Rapid 3D tracking of small RF coils. In Proceedings of the 5th Annual Meeting of ISMRM, Montreal, Canada, 1986, pp. 1131-1132.
-
(1986)
Proceedings of the 5th Annual Meeting of ISMRM
, pp. 1131-1132
-
-
Ackerman, J.L.1
Offutt, M.C.2
Buxton, R.B.3
Brady, T.J.4
-
24
-
-
0027399141
-
Real-time position monitoring of invasive devices using magnetic resonance
-
Dumoulin CL, Souza SP, Darrow RD. Real-time position monitoring of invasive devices using magnetic resonance. Magn Reson Med 1993;29:411-415.
-
(1993)
Magn Reson Med
, vol.29
, pp. 411-415
-
-
Dumoulin, C.L.1
Souza, S.P.2
Darrow, R.D.3
-
25
-
-
4243118600
-
Catheter tracking and visualization using 19F nuclear magnetic resonance
-
Kozerke S, Hegde S, Schaeffter T, Lamerichs R, Razavi R, Hill DL. Catheter tracking and visualization using 19F nuclear magnetic resonance. Magn Reson Med 2004;52:693-697.
-
(2004)
Magn Reson Med
, vol.52
, pp. 693-697
-
-
Kozerke, S.1
Hegde, S.2
Schaeffter, T.3
Lamerichs, R.4
Razavi, R.5
Hill, D.L.6
-
26
-
-
0031951983
-
Visualization of vascular guidewires using MR tracking
-
Ladd ME, Zimmermann GG, McKinnon GC, von Schulthess GK, Dumoulin CL, Darrow RD, Hofmann E, Debatin JF. Visualization of vascular guidewires using MR tracking. J Magn Reson Imaging 1998;8:251-253.
-
(1998)
J Magn Reson Imaging
, vol.8
, pp. 251-253
-
-
Ladd, M.E.1
Zimmermann, G.G.2
McKinnon, G.C.3
Von Schulthess, G.K.4
Dumoulin, C.L.5
Darrow, R.D.6
Hofmann, E.7
Debatin, J.F.8
-
27
-
-
0031751681
-
Integrated and interactive position tracking and imaging of interventional tools and internal devices using small fiducial receiver coils
-
Coutts GA, Gilderdale DJ, Chui M, Kasuboski L, DeSouza NM. Integrated and interactive position tracking and imaging of interventional tools and internal devices using small fiducial receiver coils. Magn Reson Med 1998;40:908-913.
-
(1998)
Magn Reson Med
, vol.40
, pp. 908-913
-
-
Coutts, G.A.1
Gilderdale, D.J.2
Chui, M.3
Kasuboski, L.4
Desouza, N.M.5
-
28
-
-
33847773187
-
Fast and accurate automatic registration for MR-guided procedures using active microcoils
-
Krueger S, Wolff S, Schmitgen A, Timinger H, Bublat M, Schaeffter T, Nabavi A. Fast and accurate automatic registration for MR-guided procedures using active microcoils. IEEE Trans Med Imaging 2007;26: 385-392.
-
(2007)
IEEE Trans Med Imaging
, vol.26
, pp. 385-392
-
-
Krueger, S.1
Wolff, S.2
Schmitgen, A.3
Timinger, H.4
Bublat, M.5
Schaeffter, T.6
Nabavi, A.7
-
29
-
-
70349611299
-
Prospective real-time correction for arbitrary head motion using active markers
-
Ooi MB, Krueger S, Thomas WJ, Swaminathan SV, Brown TR. Prospective real-time correction for arbitrary head motion using active markers. Magn Reson Med 2009;62:943-954.
-
(2009)
Magn Reson Med
, vol.62
, pp. 943-954
-
-
Ooi, M.B.1
Krueger, S.2
Thomas, W.J.3
Swaminathan, S.V.4
Brown, T.R.5
-
30
-
-
79959560120
-
Echo-planar imaging with prospective slice-by-slice motion correction using active markers
-
Ooi MB, Krueger S, Muraskin J, Thomas WJ, Brown TR. Echo-planar imaging with prospective slice-by-slice motion correction using active markers. Magn Reson Med 2011;66:73-81.
-
(2011)
Magn Reson Med
, vol.66
, pp. 73-81
-
-
Ooi, M.B.1
Krueger, S.2
Muraskin, J.3
Thomas, W.J.4
Brown, T.R.5
-
31
-
-
0029781333
-
Tuned fiducial markers to identify body locations with minimal perturbation of tissue magnetization
-
Burl M, Coutts GA, Young IR. Tuned fiducial markers to identify body locations with minimal perturbation of tissue magnetization. Magn Reson Med 1996;36:491-493.
-
(1996)
Magn Reson Med
, vol.36
, pp. 491-493
-
-
Burl, M.1
Coutts, G.A.2
Young, I.R.3
-
33
-
-
35148833921
-
Method for automatic localization of MR-visible markers using morphological image processing and conventional pulse sequences: Feasibility for imageguided procedures
-
Busse H, Trampel R, Grunder W, Moche M, Kahn T. Method for automatic localization of MR-visible markers using morphological image processing and conventional pulse sequences: feasibility for imageguided procedures. J Magn Reson Imaging 2007;26:1087-1096.
-
(2007)
J Magn Reson Imaging
, vol.26
, pp. 1087-1096
-
-
Busse, H.1
Trampel, R.2
Grunder, W.3
Moche, M.4
Kahn, T.5
-
34
-
-
0034759116
-
A method for fast 3D tracking using tuned fiducial markers and a limited projection reconstruction FISP (LPR-FISP) sequence
-
Flask C, Elgort D, Wong E, Shankaranarayanan A, Lewin J, Wendt M, Duerk JL. A method for fast 3D tracking using tuned fiducial markers and a limited projection reconstruction FISP (LPR-FISP) sequence. J Magn Reson Imaging 2001;14:617-627.
-
(2001)
J Magn Reson Imaging
, vol.14
, pp. 617-627
-
-
Flask, C.1
Elgort, D.2
Wong, E.3
Shankaranarayanan, A.4
Lewin, J.5
Wendt, M.6
Duerk, J.L.7
-
35
-
-
12844269349
-
Interventional magnetic resonance angiography with no strings attached: Wireless active catheter visualization
-
Quick HH, Zenge MO, Kuehl H, Kaiser G, Aker S, Massing S, Bosk S, Ladd ME. Interventional magnetic resonance angiography with no strings attached: wireless active catheter visualization. Magn Reson Med 2005;53:446-455.
-
(2005)
Magn Reson Med
, vol.53
, pp. 446-455
-
-
Quick, H.H.1
Zenge, M.O.2
Kuehl, H.3
Kaiser, G.4
Aker, S.5
Massing, S.6
Bosk, S.7
Ladd, M.E.8
-
36
-
-
16544384452
-
Catheter visualization with resonant markers at MR imaging-guided deployment of endovascular stents in swine
-
Kuehne T, Weiss S, Brinkert F, Weil J, Yilmaz S, Schmitt B, Ewert P, Lange P, Gutberlet M. Catheter visualization with resonant markers at MR imaging-guided deployment of endovascular stents in swine. Radiology 2004;233:774-780.
-
(2004)
Radiology
, vol.233
, pp. 774-780
-
-
Kuehne, T.1
Weiss, S.2
Brinkert, F.3
Weil, J.4
Yilmaz, S.5
Schmitt, B.6
Ewert, P.7
Lange, P.8
Gutberlet, M.9
-
37
-
-
0037763989
-
Image-based tracking of optically detunable parallel resonant circuits
-
Eggers H, Weiss S, Boernert P, Boesiger P. Image-based tracking of optically detunable parallel resonant circuits. Magn Reson Med 2003; 49:1163-1174.
-
(2003)
Magn Reson Med
, vol.49
, pp. 1163-1174
-
-
Eggers, H.1
Weiss, S.2
Boernert, P.3
Boesiger, P.4
-
38
-
-
0026137964
-
Least squares estimation of transformation parameters between two point patterns
-
Umeyema S. Least squares estimation of transformation parameters between two point patterns. IEEE Trans Pat Anal Mach Intel 1991;13: 376-380.
-
(1991)
IEEE Trans Pat Anal Mach Intel
, vol.13
, pp. 376-380
-
-
Umeyema, S.1
-
39
-
-
0033953459
-
Image metric-based correction (autocorrection) of motion effects: Analysis of image metrics
-
McGee KP, Manduca A, Felmlee JP, Riederer SJ, Ehman RL. Image metric-based correction (autocorrection) of motion effects: analysis of image metrics. J Magn Reson Imaging 2000;11:174-181.
-
(2000)
J Magn Reson Imaging
, vol.11
, pp. 174-181
-
-
McGee, K.P.1
Manduca, A.2
Felmlee, J.P.3
Riederer, S.J.4
Ehman, R.L.5
-
40
-
-
84883237259
-
Prospective rigid-body motion correction using miniature wireless RF-coils as position tracking probe
-
Salt Lake City, Utah, USA
-
Ooi MB, Aksoy M, Maclaren JR, Watkins RD, Bammer R.Prospective rigid-body motion correction using miniature wireless RF-coils as position tracking probe. In Proceedings of the 21st Annual Meeting of ISMRM, Salt Lake City, Utah, USA, 2013. p. 305.
-
(2013)
Proceedings of the 21st Annual Meeting of ISMRM
, pp. 305
-
-
Ooi, M.B.1
Aksoy, M.2
Maclaren, J.R.3
Watkins, R.D.4
Bammer, R.5
|