메뉴 건너뛰기




Volumn 48, Issue 3, 2015, Pages 280-286

The C-MAC® video laryngoscope is superior to the direct laryngoscope for the rescue of failed first-attempt intubations in the emergency department

Author keywords

Emergency Intubation; Failed Intubation; Rescue Intubation; Video Laryngoscopy

Indexed keywords

ADULT; ARTICLE; CONTINUOUS QUALITY IMPROVEMENT; DIRECT LARYNGOSCOPE; EMERGENCY PHYSICIAN; EMERGENCY WARD; ENDOTRACHEAL INTUBATION; FEMALE; HUMAN; INTERMETHOD COMPARISON; LARYNGOSCOPE; MAJOR CLINICAL STUDY; MALE; PRIORITY JOURNAL; TOTAL QUALITY MANAGEMENT; VIDEOLARYNGOSCOPE; ADOLESCENT; AGED; COMPARATIVE STUDY; DEVICES; EMERGENCY HEALTH SERVICE; LARYNGOSCOPY; MIDDLE AGED; PROCEDURES; PROSPECTIVE STUDY; TREATMENT FAILURE; VERY ELDERLY; YOUNG ADULT;

EID: 84924618503     PISSN: 07364679     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jemermed.2014.10.007     Document Type: Article
Times cited : (42)

References (15)
  • 1
    • 84870253268 scopus 로고    scopus 로고
    • A comparison of the C-MAC video laryngoscope to the Macintosh direct laryngoscope for intubation in the emergency department
    • J.C. Sakles, J. Mosier, and S. Chiu A comparison of the C-MAC video laryngoscope to the Macintosh direct laryngoscope for intubation in the emergency department Ann Emerg Med 60 2012 739 748
    • (2012) Ann Emerg Med , vol.60 , pp. 739-748
    • Sakles, J.C.1    Mosier, J.2    Chiu, S.3
  • 2
    • 84876683538 scopus 로고    scopus 로고
    • A comparison of the GlideScope video laryngoscope to the C-MAC video laryngoscope for intubation in the emergency department
    • J. Mosier, S. Chiu, and A.E. Patanwala A comparison of the GlideScope video laryngoscope to the C-MAC video laryngoscope for intubation in the emergency department Ann Emerg Med 61 2013 414 420
    • (2013) Ann Emerg Med , vol.61 , pp. 414-420
    • Mosier, J.1    Chiu, S.2    Patanwala, A.E.3
  • 3
    • 84895064603 scopus 로고    scopus 로고
    • Comparison of video laryngoscopy to direct laryngoscopy for intubation of patients with difficult airway characteristics in the emergency department
    • J.C. Sakles, A.E. Patanwala, and J.M. Mosier Comparison of video laryngoscopy to direct laryngoscopy for intubation of patients with difficult airway characteristics in the emergency department Intern Emerg Med 9 2014 93 98
    • (2014) Intern Emerg Med , vol.9 , pp. 93-98
    • Sakles, J.C.1    Patanwala, A.E.2    Mosier, J.M.3
  • 4
    • 84891489968 scopus 로고    scopus 로고
    • Assessing the efficacy of video versus direct laryngoscopy through retrospective comparison of 436 emergency intubation cases
    • B.M. Jones, A. Agrawal, and T.E. Schulte Assessing the efficacy of video versus direct laryngoscopy through retrospective comparison of 436 emergency intubation cases J Anesth 27 2013 927 930
    • (2013) J Anesth , vol.27 , pp. 927-930
    • Jones, B.M.1    Agrawal, A.2    Schulte, T.E.3
  • 5
    • 84857052292 scopus 로고    scopus 로고
    • Adoption of video laryngoscopy in Massachusetts emergency departments
    • A.S. Raja, A.F. Sullivan, and D.J. Pallin Adoption of video laryngoscopy in Massachusetts emergency departments J Emerg Med 42 2012 233 237
    • (2012) J Emerg Med , vol.42 , pp. 233-237
    • Raja, A.S.1    Sullivan, A.F.2    Pallin, D.J.3
  • 6
    • 79960839973 scopus 로고    scopus 로고
    • The CMAC video laryngoscope for prehospital emergency intubation: A prospective, multicenter, observational study
    • E. Cavus, A. Callies, and V. Doerges The CMAC video laryngoscope for prehospital emergency intubation: a prospective, multicenter, observational study Emerg Med J 28 2011 650 653
    • (2011) Emerg Med J , vol.28 , pp. 650-653
    • Cavus, E.1    Callies, A.2    Doerges, V.3
  • 7
    • 3242753402 scopus 로고    scopus 로고
    • Emergency tracheal intubation: Complications associated with repeated laryngoscopic attempts
    • T.C. Mort Emergency tracheal intubation: complications associated with repeated laryngoscopic attempts Anesth Analg 99 2004 607 613
    • (2004) Anesth Analg , vol.99 , pp. 607-613
    • Mort, T.C.1
  • 8
    • 84870238163 scopus 로고    scopus 로고
    • Association between repeated intubation attempts and adverse events in emergency departments: An analysis of a multicenter prospective observational study
    • K. Hasegawa, K. Shigemitsu, and Y. Hagiwara Association between repeated intubation attempts and adverse events in emergency departments: an analysis of a multicenter prospective observational study Ann Emerg Med 60 2012 749 754
    • (2012) Ann Emerg Med , vol.60 , pp. 749-754
    • Hasegawa, K.1    Shigemitsu, K.2    Hagiwara, Y.3
  • 9
    • 84872329924 scopus 로고    scopus 로고
    • The importance of first pass success when performing orotracheal intubation in the emergency department
    • J.C. Sakles, S. Chiu, and J. Mosier The importance of first pass success when performing orotracheal intubation in the emergency department Acad Emerg Med 20 2013 71 78
    • (2013) Acad Emerg Med , vol.20 , pp. 71-78
    • Sakles, J.C.1    Chiu, S.2    Mosier, J.3
  • 10
    • 84898890987 scopus 로고    scopus 로고
    • Comparison of the reusable standard GlideScope® video laryngoscope and the disposable cobalt GlideScope® video laryngoscope for tracheal intubation in an academic emergency department: A retrospective review
    • J.C. Sakles, A.E. Patanwala, and J. Mosier Comparison of the reusable standard GlideScope® video laryngoscope and the disposable cobalt GlideScope® video laryngoscope for tracheal intubation in an academic emergency department: a retrospective review Acad Emerg Med 21 2014 408 415
    • (2014) Acad Emerg Med , vol.21 , pp. 408-415
    • Sakles, J.C.1    Patanwala, A.E.2    Mosier, J.3
  • 11
    • 84883780511 scopus 로고    scopus 로고
    • Korean Emergency Airway Management Registry (KEAMR) Investigators. Factors associated with successful second and third intubation attempts in the ED
    • J.H. Kim, Y.M. Kim, and H.J. Choi Korean Emergency Airway Management Registry (KEAMR) Investigators. Factors associated with successful second and third intubation attempts in the ED Am J Emerg Med 31 2013 1376 1381
    • (2013) Am J Emerg Med , vol.31 , pp. 1376-1381
    • Kim, J.H.1    Kim, Y.M.2    Choi, H.J.3
  • 12
    • 0036625097 scopus 로고    scopus 로고
    • The failed intubation attempt in the emergency department: Analysis of prevalence, rescue techniques, and personnel
    • A.E. Bair, M.R. Filbin, and R.G. Kulkarni The failed intubation attempt in the emergency department: analysis of prevalence, rescue techniques, and personnel J Emerg Med 23 2002 131 140
    • (2002) J Emerg Med , vol.23 , pp. 131-140
    • Bair, A.E.1    Filbin, M.R.2    Kulkarni, R.G.3
  • 13
    • 84892612333 scopus 로고    scopus 로고
    • Effectiveness of the C-MAC video laryngoscope in the management of unexpected failed intubations
    • A. Kilicaslan, A. Topal, and A. Tavlan Effectiveness of the C-MAC video laryngoscope in the management of unexpected failed intubations Braz J Anesthesiol 64 2014 62 65
    • (2014) Braz J Anesthesiol , vol.64 , pp. 62-65
    • Kilicaslan, A.1    Topal, A.2    Tavlan, A.3
  • 14
    • 77953565267 scopus 로고    scopus 로고
    • Evaluation of the McGrath Series 5 video laryngoscope after failed direct laryngoscopy
    • R.R. Noppens, S. Möbus, and F. Heid Evaluation of the McGrath Series 5 video laryngoscope after failed direct laryngoscopy Anaesthesia 65 2010 716 720
    • (2010) Anaesthesia , vol.65 , pp. 716-720
    • Noppens, R.R.1    Möbus, S.2    Heid, F.3
  • 15
    • 34249052791 scopus 로고    scopus 로고
    • The Airtraq as a rescue airway device following failed direct laryngoscopy: A case series
    • C.H. Maharaj, J.F. Costello, and J.G. McDonnell The Airtraq as a rescue airway device following failed direct laryngoscopy: a case series Anaesthesia 62 2007 598 601
    • (2007) Anaesthesia , vol.62 , pp. 598-601
    • Maharaj, C.H.1    Costello, J.F.2    McDonnell, J.G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.