메뉴 건너뛰기




Volumn 12, Issue 3, 2015, Pages 631-638

Preclinical evaluation of implantable cardioverter-defibrillator developed for magnetic resonance imaging use

Author keywords

Defibrillator; Hazards; Implantablecardioverter defibrillator; Leadelectrodeheating; Magneticresonanceimaging; Ventricular fibrillationdetection

Indexed keywords

ANIMAL EXPERIMENT; ANIMAL MODEL; ARTICLE; DOG; HEART STIMULATION; HEART VENTRICLE FIBRILLATION; IMPLANTABLE CARDIOVERTER DEFIBRILLATOR; INCIDENCE; NONHUMAN; NUCLEAR MAGNETIC RESONANCE IMAGING; NUCLEAR MAGNETIC RESONANCE SCANNER; PATIENT SAFETY; PRIORITY JOURNAL; RADIATION EXPOSURE; SWINE; WHOLE BODY MRI; ADVERSE EFFECTS; ANIMAL; ARTIFICIAL HEART PACEMAKER; CARDIOVASCULAR DISEASES; DEVICE SAFETY; DEVICES; EVALUATION STUDY; HUMAN; PROCEDURES; REPRODUCIBILITY; STATISTICS AND NUMERICAL DATA; VENTRICULAR FIBRILLATION;

EID: 84924193028     PISSN: 15475271     EISSN: 15563871     Source Type: Journal    
DOI: 10.1016/j.hrthm.2014.12.012     Document Type: Article
Times cited : (16)

References (22)
  • 1
    • 84924183457 scopus 로고    scopus 로고
    • IMV Medical Information Division, Inc
    • 2012 MR Benchmark Report. IMV Medical Information Division, Inc.
    • (2012) MR Benchmark Report
  • 2
    • 84924088097 scopus 로고    scopus 로고
    • Diagnostic Imaging Online January 4, 2002. Available at:. Accessed March 20
    • Kaiser CP. Soaring MRI use draws scrutiny. Diagnostic Imaging Online January 4, 2002. Available at: http://www.diagnosticimaging.com/dimag/legacy/db-area/onlinenews/2002/2002010401.shtml. Accessed March 20, 2014.
    • (2014) Soaring MRI Use Draws Scrutiny
    • Kaiser, C.P.1
  • 3
    • 18044393463 scopus 로고    scopus 로고
    • Current clinical issues for MRI scanning of pacemaker and defibrillator patients
    • R. Kalin, and M.S. Stanton Current clinical issues for MRI scanning of pacemaker and defibrillator patients Pacing Clin Electrophysiol 28 2005 326 328
    • (2005) Pacing Clin Electrophysiol , vol.28 , pp. 326-328
    • Kalin, R.1    Stanton, M.S.2
  • 5
    • 78650670809 scopus 로고    scopus 로고
    • Magnetic resonance imaging in patients with a pacemaker system designed for the magnetic resonance environment
    • B.L. Wilkoff, D. Bello, and M. Taborsky Magnetic resonance imaging in patients with a pacemaker system designed for the magnetic resonance environment Heart Rhythm 8 2011 65 73
    • (2011) Heart Rhythm , vol.8 , pp. 65-73
    • Wilkoff, B.L.1    Bello, D.2    Taborsky, M.3
  • 7
    • 0036800991 scopus 로고    scopus 로고
    • Pacemaker reed switch behavior in 0.5, 1.5, and 3.0 Tesla magnetic resonance imaging units: Are reed switches always closed in strong magnetic fields?
    • R. Luechinger, F. Duru, V. Zeijlemaker, M.B. Scheidegger, P. Boesiger, and R. Candinas Pacemaker reed switch behavior in 0.5, 1.5, and 3.0 Tesla magnetic resonance imaging units: are reed switches always closed in strong magnetic fields? Pacing Clin Electrophysioj 25 2002 1419 1423
    • (2002) Pacing Clin Electrophysioj , vol.25 , pp. 1419-1423
    • Luechinger, R.1    Duru, F.2    Zeijlemaker, V.3    Scheidegger, M.B.4    Boesiger, P.5    Candinas, R.6
  • 9
    • 84924177291 scopus 로고    scopus 로고
    • Assessment of the safety of magnetic resonance imaging for patients with an active implantable medical device
    • Geneva, Switzerland. ISO/TS10974:2012
    • Assessment of the safety of magnetic resonance imaging for patients with an active implantable medical device. International Organization for Standardization, Geneva, Switzerland. ISO/TS10974:2012.
    • International Organization for Standardization
  • 16
    • 3242768382 scopus 로고    scopus 로고
    • Complete loss of ICD programmability after magnetic resonance imaging
    • M. Fiek, T. Remp, C. Reithmann, and G. Steinbeck Complete loss of ICD programmability after magnetic resonance imaging Pacing Clin Electrophysiol 27 2004 1002 1004
    • (2004) Pacing Clin Electrophysiol , vol.27 , pp. 1002-1004
    • Fiek, M.1    Remp, T.2    Reithmann, C.3    Steinbeck, G.4
  • 20
    • 80053531595 scopus 로고    scopus 로고
    • A prospective evaluation of a protocol for magnetic resonance imaging of patients with implanted cardiac devices
    • S. Nazarian, R. Hanzford, and A. Roguin A prospective evaluation of a protocol for magnetic resonance imaging of patients with implanted cardiac devices Ann Intern Med 155 2011 415 424
    • (2011) Ann Intern Med , vol.155 , pp. 415-424
    • Nazarian, S.1    Hanzford, R.2    Roguin, A.3
  • 21
    • 84869089727 scopus 로고    scopus 로고
    • 1.5 Tesla for patients with pacemakers and implantable cardiac defibrillators
    • J.D. Cohen, H.S. Costa, and R.J. Russo 1.5 Tesla for patients with pacemakers and implantable cardiac defibrillators Am J Cardiol 10 2012 1631 1636
    • (2012) Am J Cardiol , vol.10 , pp. 1631-1636
    • Cohen, J.D.1    Costa, H.S.2    Russo, R.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.