메뉴 건너뛰기




Volumn 31, Issue 3, 2015, Pages 270-277

A Systematic Review and Meta-analysis of the Association Between Implantable Cardioverter-Defibrillator Shocks and Long-term Mortality

(11)  Proietti, Riccardo a,b   Labos, Christopher a   Davis, Mark a   Thanassoulis, George a   Santangeli, Pasquale c   Russo, Vincenzo d   Di Biase, Luigi e,f   Roux, Jean Francois a,g   Verma, Atul a,h   Natale, Andrea e,i,j,k   Essebag, Vidal a,l  


Author keywords

[No Author keywords available]

Indexed keywords

EFFECT SIZE; HEART DEATH; HEART VENTRICLE ARRHYTHMIA; HUMAN; IMPLANTABLE CARDIOVERTER DEFIBRILLATOR; INFORMATION RETRIEVAL; META ANALYSIS; MORTALITY; QUALITY CONTROL; RANDOMIZED CONTROLLED TRIAL (TOPIC); REVIEW; RISK ASSESSMENT; SHOCK; SYSTEMATIC REVIEW; ADVERSE EFFECTS; ARRHYTHMIAS, CARDIAC; HEART FAILURE; RISK FACTOR; SURVIVAL;

EID: 84923927051     PISSN: 0828282X     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.cjca.2014.11.023     Document Type: Review
Times cited : (73)

References (53)
  • 1
    • 9844224486 scopus 로고    scopus 로고
    • Acomparison of antiarrhythmic-drug therapy with implantable defibrillators in patients resuscitated from near-fatal ventricular arrhythmias. The Antiarrhythmics versus Implantable Defibrillators (AVID) Investigators
    • Acomparison of antiarrhythmic-drug therapy with implantable defibrillators in patients resuscitated from near-fatal ventricular arrhythmias. The Antiarrhythmics versus Implantable Defibrillators (AVID) Investigators. NEngl J Med 1997, 337:1576-1583.
    • (1997) NEngl J Med , vol.337 , pp. 1576-1583
  • 2
    • 0033576804 scopus 로고    scopus 로고
    • Arandomized study of the prevention of sudden death in patients with coronary artery disease. Multicenter Unsustained Tachycardia Trial Investigators
    • Buxton A.E., Lee K.L., Fisher J.D., et al. Arandomized study of the prevention of sudden death in patients with coronary artery disease. Multicenter Unsustained Tachycardia Trial Investigators. NEngl J Med 1999, 341:1882-1890.
    • (1999) NEngl J Med , vol.341 , pp. 1882-1890
    • Buxton, A.E.1    Lee, K.L.2    Fisher, J.D.3
  • 3
    • 0034696531 scopus 로고    scopus 로고
    • Canadian implantable defibrillator study (CIDS): a randomized trial of the implantable cardioverter-defibrillator against amiodarone
    • Connolly S.J., Gent M., Roberts R.S., et al. Canadian implantable defibrillator study (CIDS): a randomized trial of the implantable cardioverter-defibrillator against amiodarone. Circulation 2000, 101:1297-1302.
    • (2000) Circulation , vol.101 , pp. 1297-1302
    • Connolly, S.J.1    Gent, M.2    Roberts, R.S.3
  • 4
    • 0006918490 scopus 로고    scopus 로고
    • Improved survival with an implanted defibrillator in patients with coronary disease at high risk for ventricular arrhythmia. Multicenter Automatic Defibrillator Implantation Trial Investigators
    • Moss A.J., Hall W.J., Cannom D.S., et al. Improved survival with an implanted defibrillator in patients with coronary disease at high risk for ventricular arrhythmia. Multicenter Automatic Defibrillator Implantation Trial Investigators. NEngl J Med 1996, 335:1933-1940.
    • (1996) NEngl J Med , vol.335 , pp. 1933-1940
    • Moss, A.J.1    Hall, W.J.2    Cannom, D.S.3
  • 5
    • 0037149716 scopus 로고    scopus 로고
    • Prophylactic implantation of a defibrillator in patients with myocardial infarction and reduced ejection fraction
    • Multicenter Automatic Defibrillator Implantation Trial II Investigators
    • Moss A.J., Zareba W., Hall W.J., et al. Prophylactic implantation of a defibrillator in patients with myocardial infarction and reduced ejection fraction. NEngl J Med 2002, 346:877-883. Multicenter Automatic Defibrillator Implantation Trial II Investigators.
    • (2002) NEngl J Med , vol.346 , pp. 877-883
    • Moss, A.J.1    Zareba, W.2    Hall, W.J.3
  • 6
    • 0038208385 scopus 로고    scopus 로고
    • Expanding indications for defibrillators after myocardial infarction: risk stratification and cost effectiveness
    • Essebag V., Eisenberg M.J. Expanding indications for defibrillators after myocardial infarction: risk stratification and cost effectiveness. Card Electrophysiol Rev 2003, 7:43-48.
    • (2003) Card Electrophysiol Rev , vol.7 , pp. 43-48
    • Essebag, V.1    Eisenberg, M.J.2
  • 7
    • 19944413618 scopus 로고    scopus 로고
    • Long-term clinical course of patients after termination of ventricular tachyarrhythmia by an implanted defibrillator
    • Multicenter Automatic Defibrillator Implantation Trial-II Research Group
    • Moss A.J., Greenberg H., Case R.B., et al. Long-term clinical course of patients after termination of ventricular tachyarrhythmia by an implanted defibrillator. Circulation 2004, 110:3760-3765. Multicenter Automatic Defibrillator Implantation Trial-II Research Group.
    • (2004) Circulation , vol.110 , pp. 3760-3765
    • Moss, A.J.1    Greenberg, H.2    Case, R.B.3
  • 8
    • 50949090502 scopus 로고    scopus 로고
    • Prognostic importance of defibrillator shocks in patients with heart failure
    • Poole J.E., Johnson G.W., Hellkamp A.S., et al. Prognostic importance of defibrillator shocks in patients with heart failure. NEngl J Med 2008, 359:1009-1017.
    • (2008) NEngl J Med , vol.359 , pp. 1009-1017
    • Poole, J.E.1    Johnson, G.W.2    Hellkamp, A.S.3
  • 9
    • 41149165849 scopus 로고    scopus 로고
    • Inappropriate implantable cardioverter-defibrillator shocks in MADIT II: frequency, mechanisms, predictors, and survival impact
    • MADIT II Investigators
    • Daubert J.P., Zareba W., Cannom D.S., et al. Inappropriate implantable cardioverter-defibrillator shocks in MADIT II: frequency, mechanisms, predictors, and survival impact. JAm Coll Cardiol 2008, 51:1357-1365. MADIT II Investigators.
    • (2008) JAm Coll Cardiol , vol.51 , pp. 1357-1365
    • Daubert, J.P.1    Zareba, W.2    Cannom, D.S.3
  • 10
    • 77952529329 scopus 로고    scopus 로고
    • The prognostic impact of shocks for clinical and induced arrhythmias on morbidity and mortality among patients with implantable cardioverter-defibrillators
    • Bhavnani S.P., Kluger J., Coleman C.I., et al. The prognostic impact of shocks for clinical and induced arrhythmias on morbidity and mortality among patients with implantable cardioverter-defibrillators. Heart Rhythm 2010, 7:755-760.
    • (2010) Heart Rhythm , vol.7 , pp. 755-760
    • Bhavnani, S.P.1    Kluger, J.2    Coleman, C.I.3
  • 11
    • 82455194861 scopus 로고    scopus 로고
    • Shocks burden and increased mortality in implantable cardioverter-defibrillator patients
    • Larsen G.K., Evans J., Lambert W.E., Chen Y., Raitt M.H. Shocks burden and increased mortality in implantable cardioverter-defibrillator patients. Heart Rhythm 2011, 8:1881-1886.
    • (2011) Heart Rhythm , vol.8 , pp. 1881-1886
    • Larsen, G.K.1    Evans, J.2    Lambert, W.E.3    Chen, Y.4    Raitt, M.H.5
  • 12
    • 84886409725 scopus 로고    scopus 로고
    • Survival after shock therapy in implantable cardioverter-defibrillator and cardiac resynchronization therapy-defibrillator recipients according to rhythm shocked. The ALTITUDE survival by rhythm study
    • Powell B.D., Saxon L.A., Boehmer J.P., et al. Survival after shock therapy in implantable cardioverter-defibrillator and cardiac resynchronization therapy-defibrillator recipients according to rhythm shocked. The ALTITUDE survival by rhythm study. JAm Coll Cardiol 2013, 62:1674-1679.
    • (2013) JAm Coll Cardiol , vol.62 , pp. 1674-1679
    • Powell, B.D.1    Saxon, L.A.2    Boehmer, J.P.3
  • 13
    • 78650692944 scopus 로고    scopus 로고
    • Long-term outcome after ICD and CRT implantation and influence of remote device follow-up: the ALTITUDE survival study
    • Saxon L.A., Hayes D.L., Gilliam F.R., et al. Long-term outcome after ICD and CRT implantation and influence of remote device follow-up: the ALTITUDE survival study. Circulation 2010, 122:2359-2367.
    • (2010) Circulation , vol.122 , pp. 2359-2367
    • Saxon, L.A.1    Hayes, D.L.2    Gilliam, F.R.3
  • 14
    • 84877608466 scopus 로고    scopus 로고
    • Impact of shocks on mortality in patients with ischemic or dilated cardiomyopathy and defibrillators implanted for primary prevention
    • Streitner F., Herrmann T., Kuschyk J., et al. Impact of shocks on mortality in patients with ischemic or dilated cardiomyopathy and defibrillators implanted for primary prevention. PLoS One 2013, 8:e63911.
    • (2013) PLoS One , vol.8 , pp. e63911
    • Streitner, F.1    Herrmann, T.2    Kuschyk, J.3
  • 15
    • 79251577161 scopus 로고    scopus 로고
    • Inappropriate implantable cardioverter-defibrillator shocks: incidence, predictors, and impact on mortality
    • van Rees J.B., Borleffs C.J., de Bie M.K., et al. Inappropriate implantable cardioverter-defibrillator shocks: incidence, predictors, and impact on mortality. JAm Coll Cardiol 2011, 57:556-562.
    • (2011) JAm Coll Cardiol , vol.57 , pp. 556-562
    • van Rees, J.B.1    Borleffs, C.J.2    de Bie, M.K.3
  • 16
    • 78650710668 scopus 로고    scopus 로고
    • Mechanisms underlying the lack of effect of implantable cardioverter-defibrillator therapy on mortality in high-risk patients with recent myocardial infarction: insights from the Defibrillation in Acute Myocardial Infarction Trial (DINAMIT)
    • Dorian P., Hohnloser S.H., Thorpe K.E., et al. Mechanisms underlying the lack of effect of implantable cardioverter-defibrillator therapy on mortality in high-risk patients with recent myocardial infarction: insights from the Defibrillation in Acute Myocardial Infarction Trial (DINAMIT). Circulation 2010, 122:2645-2652.
    • (2010) Circulation , vol.122 , pp. 2645-2652
    • Dorian, P.1    Hohnloser, S.H.2    Thorpe, K.E.3
  • 17
    • 0032698279 scopus 로고    scopus 로고
    • Detection of myocardial injury during transvenous implantation of automatic cardioverter-defibrillators
    • Hurst T.M., Hinrichs M., Breidenbach C., Katz N., Waldecker B. Detection of myocardial injury during transvenous implantation of automatic cardioverter-defibrillators. JAm Coll Cardiol 1999, 34:402-408.
    • (1999) JAm Coll Cardiol , vol.34 , pp. 402-408
    • Hurst, T.M.1    Hinrichs, M.2    Breidenbach, C.3    Katz, N.4    Waldecker, B.5
  • 18
    • 0032514609 scopus 로고    scopus 로고
    • Gross and microscopic pathological changes associated with nonthoracotomy implantable defibrillator leads
    • Epstein A.E., Kay G.N., Plumb V.J., Dailey S.M., Anderson P.G. Gross and microscopic pathological changes associated with nonthoracotomy implantable defibrillator leads. Circulation 1998, 98:1517-1524.
    • (1998) Circulation , vol.98 , pp. 1517-1524
    • Epstein, A.E.1    Kay, G.N.2    Plumb, V.J.3    Dailey, S.M.4    Anderson, P.G.5
  • 19
    • 68649128497 scopus 로고    scopus 로고
    • Transient local injury current in right ventricular electrogram after implantable cardioverter-defibrillator shock predicts heart failure progression
    • Tereshchenko L.G., Faddis M.N., Fetics B.J., et al. Transient local injury current in right ventricular electrogram after implantable cardioverter-defibrillator shock predicts heart failure progression. JAm Coll Cardiol 2009, 54:822-828.
    • (2009) JAm Coll Cardiol , vol.54 , pp. 822-828
    • Tereshchenko, L.G.1    Faddis, M.N.2    Fetics, B.J.3
  • 20
    • 0030838120 scopus 로고    scopus 로고
    • High-energy defibrillation increases the severity of postresuscitation myocardial dysfunction
    • Xie J., Weil M.H., Sun S., et al. High-energy defibrillation increases the severity of postresuscitation myocardial dysfunction. Circulation 1997, 96:683-688.
    • (1997) Circulation , vol.96 , pp. 683-688
    • Xie, J.1    Weil, M.H.2    Sun, S.3
  • 21
    • 84882241755 scopus 로고    scopus 로고
    • Influence of diabetes mellitus on inappropriate and appropriate implantable cardioverter-defibrillator therapy and mortality in the Multicenter Automatic Defibrillator Implantation Trial-Reduce Inappropriate Therapy (MADIT-RIT) Trial
    • Ruwald M.H., Zareba W., Jons C., et al. Influence of diabetes mellitus on inappropriate and appropriate implantable cardioverter-defibrillator therapy and mortality in the Multicenter Automatic Defibrillator Implantation Trial-Reduce Inappropriate Therapy (MADIT-RIT) Trial. Circulation 2013, 128:694-701.
    • (2013) Circulation , vol.128 , pp. 694-701
    • Ruwald, M.H.1    Zareba, W.2    Jons, C.3
  • 22
    • 33745504896 scopus 로고    scopus 로고
    • Clinical course and long-term follow-up of patients receiving implantable cardioverter-defibrillators
    • Tandri H., Griffith L.S., Tang T., et al. Clinical course and long-term follow-up of patients receiving implantable cardioverter-defibrillators. Heart Rhythm 2006, 3:762-768.
    • (2006) Heart Rhythm , vol.3 , pp. 762-768
    • Tandri, H.1    Griffith, L.S.2    Tang, T.3
  • 23
    • 71949096960 scopus 로고    scopus 로고
    • Appropriate evaluation and treatment of heart failure patients after implantable cardioverter-defibrillator discharge: time to go beyond the initial shock
    • Mishkin J.D., Saxonhouse S.J., Woo G.W., et al. Appropriate evaluation and treatment of heart failure patients after implantable cardioverter-defibrillator discharge: time to go beyond the initial shock. JAm Coll Cardiol 2009, 54:1993-2000.
    • (2009) JAm Coll Cardiol , vol.54 , pp. 1993-2000
    • Mishkin, J.D.1    Saxonhouse, S.J.2    Woo, G.W.3
  • 24
    • 33645642434 scopus 로고    scopus 로고
    • Evaluation of the quality of prognosis studies in systematic reviews
    • Hayden J.A., Cote P., Bombardier C. Evaluation of the quality of prognosis studies in systematic reviews. Ann Intern Med 2006, 144:427-437.
    • (2006) Ann Intern Med , vol.144 , pp. 427-437
    • Hayden, J.A.1    Cote, P.2    Bombardier, C.3
  • 26
    • 79961238388 scopus 로고    scopus 로고
    • Recommendations for examining and interpreting funnel plot asymmetry in meta-analyses of randomised controlled trials
    • Sterne J.A., Sutton A.J., Ioannidis J.P., et al. Recommendations for examining and interpreting funnel plot asymmetry in meta-analyses of randomised controlled trials. BMJ 2011, 343:d4002.
    • (2011) BMJ , vol.343 , pp. d4002
    • Sterne, J.A.1    Sutton, A.J.2    Ioannidis, J.P.3
  • 27
    • 0030922816 scopus 로고    scopus 로고
    • Bias in meta-analysis detected by a simple, graphical test
    • Egger M., Davey Smith G., Schneider M., Minder C. Bias in meta-analysis detected by a simple, graphical test. BMJ 1997, 315:629-634.
    • (1997) BMJ , vol.315 , pp. 629-634
    • Egger, M.1    Davey Smith, G.2    Schneider, M.3    Minder, C.4
  • 28
    • 79960387726 scopus 로고    scopus 로고
    • Appropriate therapy but not inappropriate shocks predict survival in implantable cardioverter-defibrillator patients
    • Dichtl W., Wolber T., Paoli U., et al. Appropriate therapy but not inappropriate shocks predict survival in implantable cardioverter-defibrillator patients. Clin Cardiol 2011, 34:433-436.
    • (2011) Clin Cardiol , vol.34 , pp. 433-436
    • Dichtl, W.1    Wolber, T.2    Paoli, U.3
  • 29
    • 33644870367 scopus 로고    scopus 로고
    • Are implantable cardioverter-defibrillator shocks a surrogate for sudden cardiac death in patients with nonischemic cardiomyopathy?
    • Defibrillators in Non-Ischemic Cardiomyopathy Treatment Evaluation (DEFINITE) Investigators
    • Ellenbogen K.A., Levine J.H., Berger R.D., et al. Are implantable cardioverter-defibrillator shocks a surrogate for sudden cardiac death in patients with nonischemic cardiomyopathy?. Circulation 2006, 113:776-782. Defibrillators in Non-Ischemic Cardiomyopathy Treatment Evaluation (DEFINITE) Investigators.
    • (2006) Circulation , vol.113 , pp. 776-782
    • Ellenbogen, K.A.1    Levine, J.H.2    Berger, R.D.3
  • 30
    • 78650209858 scopus 로고    scopus 로고
    • Incidence of appropriate cardioverter-defibrillator shocks and mortality in patients with implantable cardioverter-defibrillators with ischemic cardiomyopathy versus nonischemic cardiomyopathy at 33-month follow-up
    • Gandhi K., Aronow W.S., Desai H., et al. Incidence of appropriate cardioverter-defibrillator shocks and mortality in patients with implantable cardioverter-defibrillators with ischemic cardiomyopathy versus nonischemic cardiomyopathy at 33-month follow-up. Arch Med Sci 2010, 6:900-903.
    • (2010) Arch Med Sci , vol.6 , pp. 900-903
    • Gandhi, K.1    Aronow, W.S.2    Desai, H.3
  • 31
    • 84871065661 scopus 로고    scopus 로고
    • Reduction in inappropriate therapy and mortality through ICD programming
    • MADIT-RIT Trial Investigators
    • Moss A.J., Schuger C., Beck C.A., et al. Reduction in inappropriate therapy and mortality through ICD programming. NEngl J Med 2012, 367:2275-2283. MADIT-RIT Trial Investigators.
    • (2012) NEngl J Med , vol.367 , pp. 2275-2283
    • Moss, A.J.1    Schuger, C.2    Beck, C.A.3
  • 32
    • 76849091527 scopus 로고    scopus 로고
    • Differences in effects of electrical therapy type for ventricular arrhythmias on mortality in implantable cardioverter-defibrillator patients
    • Sweeney M.O., Sherfesee L., DeGroot P.J., Wathen M.S., Wilkoff B.L. Differences in effects of electrical therapy type for ventricular arrhythmias on mortality in implantable cardioverter-defibrillator patients. Heart Rhythm 2010, 7:353-360.
    • (2010) Heart Rhythm , vol.7 , pp. 353-360
    • Sweeney, M.O.1    Sherfesee, L.2    DeGroot, P.J.3    Wathen, M.S.4    Wilkoff, B.L.5
  • 33
    • 20444492445 scopus 로고    scopus 로고
    • Appropriate and inappropriate ventricular therapies, quality of life, and mortality among primary and secondary prevention implantable cardioverter-defibrillator patients: results from the Pacing Fast VT REduces Shock ThErapies (PainFREE Rx II) trial
    • Sweeney M.O., Wathen M.S., Volosin K., et al. Appropriate and inappropriate ventricular therapies, quality of life, and mortality among primary and secondary prevention implantable cardioverter-defibrillator patients: results from the Pacing Fast VT REduces Shock ThErapies (PainFREE Rx II) trial. Circulation 2005, 111:2898-2905.
    • (2005) Circulation , vol.111 , pp. 2898-2905
    • Sweeney, M.O.1    Wathen, M.S.2    Volosin, K.3
  • 34
    • 84879318184 scopus 로고    scopus 로고
    • Survival after implantable cardioverter-defibrillator implantation in the elderly
    • Yung D., Birnie D., Dorian P., et al. Survival after implantable cardioverter-defibrillator implantation in the elderly. Circulation 2013, 127:2383-2392.
    • (2013) Circulation , vol.127 , pp. 2383-2392
    • Yung, D.1    Birnie, D.2    Dorian, P.3
  • 35
    • 84892667919 scopus 로고    scopus 로고
    • Association between myocardial substrate, implantable cardioverter-defibrillator shocks and mortality in MADIT-CRT
    • Sood N., Ruwald A.C., Solomon S., et al. Association between myocardial substrate, implantable cardioverter-defibrillator shocks and mortality in MADIT-CRT. Eur Heart J 2014, 35:106-115.
    • (2014) Eur Heart J , vol.35 , pp. 106-115
    • Sood, N.1    Ruwald, A.C.2    Solomon, S.3
  • 36
    • 85027918824 scopus 로고    scopus 로고
    • The association between ICD interventions and mortality is independent of their modality: clinical implications
    • Bencardino G., DI Monaco A., Rio T., et al. The association between ICD interventions and mortality is independent of their modality: clinical implications. JCardiovasc Electrophysiol 2014, 25:1363-1367.
    • (2014) JCardiovasc Electrophysiol , vol.25 , pp. 1363-1367
    • Bencardino, G.1    DI Monaco, A.2    Rio, T.3
  • 37
    • 84923923117 scopus 로고    scopus 로고
    • Mortality reduction in relation to implantable cardioverter-defibrillator programming in the Multicenter Automatic Defibrillator Implantation Trial-Reduce Inappropriate Therapy (MADIT-RIT)
    • Ruwald A.C., Schuger C., Moss A.J., et al. Mortality reduction in relation to implantable cardioverter-defibrillator programming in the Multicenter Automatic Defibrillator Implantation Trial-Reduce Inappropriate Therapy (MADIT-RIT). Circ Arrhythm Electrophysiol 2014, 7:785-792.
    • (2014) Circ Arrhythm Electrophysiol , vol.7 , pp. 785-792
    • Ruwald, A.C.1    Schuger, C.2    Moss, A.J.3
  • 38
    • 33645739897 scopus 로고    scopus 로고
    • Frequency and causes of implantable cardioverter-defibrillator therapies: is device therapy proarrhythmic?
    • Germano J.J., Reynolds M., Essebag V., Josephson M.E. Frequency and causes of implantable cardioverter-defibrillator therapies: is device therapy proarrhythmic?. Am J Cardiol 2006, 97:1255-1261.
    • (2006) Am J Cardiol , vol.97 , pp. 1255-1261
    • Germano, J.J.1    Reynolds, M.2    Essebag, V.3    Josephson, M.E.4
  • 39
    • 20844455272 scopus 로고    scopus 로고
    • Placebo-controlled, randomized clinical trial of azimilide for prevention of ventricular tachyarrhythmias in patients with an implantable cardioverter-defibrillator
    • SHock Inhibition Evaluation with azimiLiDe (SHIELD) Investigators
    • Dorian P., Borggrefe M., Al-Khalidi H.R., et al. Placebo-controlled, randomized clinical trial of azimilide for prevention of ventricular tachyarrhythmias in patients with an implantable cardioverter-defibrillator. Circulation 2004, 110:3646-3654. SHock Inhibition Evaluation with azimiLiDe (SHIELD) Investigators.
    • (2004) Circulation , vol.110 , pp. 3646-3654
    • Dorian, P.1    Borggrefe, M.2    Al-Khalidi, H.R.3
  • 40
    • 30444439243 scopus 로고    scopus 로고
    • Comparison of beta-blockers, amiodarone plus beta-blockers, or sotalol for prevention of shocks from implantable cardioverter-defibrillators: the OPTIC Study: a randomized trial
    • Optimal Pharmacological Therapy in Cardioverter-defibrillator Patients (OPTIC) Investigators
    • Connolly S.J., Dorian P., Roberts R.S., et al. Comparison of beta-blockers, amiodarone plus beta-blockers, or sotalol for prevention of shocks from implantable cardioverter-defibrillators: the OPTIC Study: a randomized trial. JAMA 2006, 295:165-171. Optimal Pharmacological Therapy in Cardioverter-defibrillator Patients (OPTIC) Investigators.
    • (2006) JAMA , vol.295 , pp. 165-171
    • Connolly, S.J.1    Dorian, P.2    Roberts, R.S.3
  • 41
    • 84877289895 scopus 로고    scopus 로고
    • Effect of long-detection interval vs standard-detection interval for implantable cardioverter-defibrillators on antitachycardia pacing and shock delivery: the ADVANCE III randomized clinical trial
    • Gasparini M., Proclemer A., Klersy C., et al. Effect of long-detection interval vs standard-detection interval for implantable cardioverter-defibrillators on antitachycardia pacing and shock delivery: the ADVANCE III randomized clinical trial. JAMA 2013, 309:1903-1911.
    • (2013) JAMA , vol.309 , pp. 1903-1911
    • Gasparini, M.1    Proclemer, A.2    Klersy, C.3
  • 42
    • 48449088263 scopus 로고    scopus 로고
    • Strategic programming of detection and therapy parameters in implantable cardioverter-defibrillators reduces shocks in primary prevention patients: results from the PREPARE (Primary Prevention Parameters Evaluation) study
    • PREPARE Study Investigators
    • Wilkoff B.L., Williamson B.D., Stern R.S., et al. Strategic programming of detection and therapy parameters in implantable cardioverter-defibrillators reduces shocks in primary prevention patients: results from the PREPARE (Primary Prevention Parameters Evaluation) study. JAm Coll Cardiol 2008, 52:541-550. PREPARE Study Investigators.
    • (2008) JAm Coll Cardiol , vol.52 , pp. 541-550
    • Wilkoff, B.L.1    Williamson, B.D.2    Stern, R.S.3
  • 43
    • 72949089021 scopus 로고    scopus 로고
    • Catheter ablation of stable ventricular tachycardia before defibrillator implantation in patients with coronary heart disease (VTACH): a multicentre randomised controlled trial
    • VTACH study group
    • Kuck K.H., Schaumann A., Eckardt L., et al. Catheter ablation of stable ventricular tachycardia before defibrillator implantation in patients with coronary heart disease (VTACH): a multicentre randomised controlled trial. Lancet 2010, 375:31-40. VTACH study group.
    • (2010) Lancet , vol.375 , pp. 31-40
    • Kuck, K.H.1    Schaumann, A.2    Eckardt, L.3
  • 44
    • 62149106694 scopus 로고    scopus 로고
    • Guidance for catheter ablation of ventricular arrhythmia
    • Potse M., Essebag V. Guidance for catheter ablation of ventricular arrhythmia. Med Biol Eng Comput 2009, 47:241-243.
    • (2009) Med Biol Eng Comput , vol.47 , pp. 241-243
    • Potse, M.1    Essebag, V.2
  • 45
    • 84870404695 scopus 로고    scopus 로고
    • Implantable cardioverter-defibrillator shock prevention does not reduce mortality: a systemic review
    • Ha A.H., Ham I., Nair G.M., et al. Implantable cardioverter-defibrillator shock prevention does not reduce mortality: a systemic review. Heart Rhythm 2012, 9:2068-2074.
    • (2012) Heart Rhythm , vol.9 , pp. 2068-2074
    • Ha, A.H.1    Ham, I.2    Nair, G.M.3
  • 46
    • 84898872436 scopus 로고    scopus 로고
    • Impact of programming strategies aimed at reducing nonessential implantable cardioverter-defibrillator therapies on mortality: a systematic review and meta-analysis
    • Tan V.H., Wilton S.B., Kuriachan V., Sumner G.L., Exner D.V. Impact of programming strategies aimed at reducing nonessential implantable cardioverter-defibrillator therapies on mortality: a systematic review and meta-analysis. Circ Arrhyth Electrophysiol 2014, 7:164-170.
    • (2014) Circ Arrhyth Electrophysiol , vol.7 , pp. 164-170
    • Tan, V.H.1    Wilton, S.B.2    Kuriachan, V.3    Sumner, G.L.4    Exner, D.V.5
  • 47
    • 18844479760 scopus 로고    scopus 로고
    • Basic mechanisms of cardiac impulse propagation and associated arrhythmias
    • Kleber A.G., Rudy Y. Basic mechanisms of cardiac impulse propagation and associated arrhythmias. Physiol Rev 2004, 84:431-488.
    • (2004) Physiol Rev , vol.84 , pp. 431-488
    • Kleber, A.G.1    Rudy, Y.2
  • 48
    • 67649321439 scopus 로고    scopus 로고
    • Fundamental differences in electrophysiologic and electroanatomic substrate between ischemic cardiomyopathy patients with and without clinical ventricular tachycardia
    • Haqqani H.M., Kalman J.M., Roberts-Thomson K.C., et al. Fundamental differences in electrophysiologic and electroanatomic substrate between ischemic cardiomyopathy patients with and without clinical ventricular tachycardia. JAm Coll Cardiol 2009, 54:166-173.
    • (2009) JAm Coll Cardiol , vol.54 , pp. 166-173
    • Haqqani, H.M.1    Kalman, J.M.2    Roberts-Thomson, K.C.3
  • 49
    • 84892992167 scopus 로고    scopus 로고
    • Catheter ablation for ventricular tachycardia in structural heart disease
    • Macintyre C.J., Sapp J.L. Catheter ablation for ventricular tachycardia in structural heart disease. Can J Cardiol 2014, 30:244-246.
    • (2014) Can J Cardiol , vol.30 , pp. 244-246
    • Macintyre, C.J.1    Sapp, J.L.2
  • 50
    • 84888210460 scopus 로고    scopus 로고
    • Predictors of mortality in patients with an implantable cardiac defibrillator: a systematic review and meta-analysis
    • Alba A.C., Braga J., Gewarges M., et al. Predictors of mortality in patients with an implantable cardiac defibrillator: a systematic review and meta-analysis. Can J Cardiol 2013, 29:1729-1740.
    • (2013) Can J Cardiol , vol.29 , pp. 1729-1740
    • Alba, A.C.1    Braga, J.2    Gewarges, M.3
  • 51
    • 34548010736 scopus 로고    scopus 로고
    • Membrane permeabilization and cell damage by ultrashort electric field shocks
    • Pakhomov A.G., Shevin R., White J.A., et al. Membrane permeabilization and cell damage by ultrashort electric field shocks. Arch Biochem Biophys 2007, 465:109-118.
    • (2007) Arch Biochem Biophys , vol.465 , pp. 109-118
    • Pakhomov, A.G.1    Shevin, R.2    White, J.A.3
  • 52
    • 0034575127 scopus 로고    scopus 로고
    • Biophysical injury mechanisms in electrical shock trauma
    • Lee R.C., Zhang D., Hannig J. Biophysical injury mechanisms in electrical shock trauma. Ann Rev Biomed Eng 2000, 2:477-509.
    • (2000) Ann Rev Biomed Eng , vol.2 , pp. 477-509
    • Lee, R.C.1    Zhang, D.2    Hannig, J.3
  • 53
    • 79958084460 scopus 로고    scopus 로고
    • Ca(2+)-related signaling and protein phosphorylation abnormalities play central roles in a new experimental model of electrical storm
    • Tsuji Y., Hojo M., Voigt N., et al. Ca(2+)-related signaling and protein phosphorylation abnormalities play central roles in a new experimental model of electrical storm. Circulation 2011, 123:2192-2203.
    • (2011) Circulation , vol.123 , pp. 2192-2203
    • Tsuji, Y.1    Hojo, M.2    Voigt, N.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.