메뉴 건너뛰기




Volumn 120, Issue 1, 2015, Pages 66-75

Metrology in medicine: From measurements to decision, with specific reference to anesthesia and intensive care

Author keywords

[No Author keywords available]

Indexed keywords

ANESTHESIA; CALIBRATION; CLINICAL DECISION MAKING; DIAGNOSIS; HUMAN; INTENSIVE CARE; MATHEMATICAL VARIABLE; MEASUREMENT; MEASUREMENT ACCURACY; MEASUREMENT ERROR; MEASUREMENT PRECISION; MEASUREMENT REPEATABILITY; MEASUREMENT TRUENESS; MEASUREMENT UNCERTAINTY; MEDICAL PRACTICE; NOMENCLATURE; PARAMETERS; PRACTICE GUIDELINE; PRIORITY JOURNAL; RANDOM ERROR; REFERENCE VALUE; REPRODUCIBILITY; REVIEW; STANDARD; STATISTICAL ANALYSIS; TITRIMETRY; TRANSDUCER; UNCERTAINTY; MEDICINE; PROCEDURES; STANDARDS;

EID: 84923882211     PISSN: 00032999     EISSN: 15267598     Source Type: Journal    
DOI: 10.1213/ANE.0000000000000477     Document Type: Review
Times cited : (31)

References (20)
  • 2
    • 84888997368 scopus 로고    scopus 로고
    • Difficulties and challenges associated with literature searches in operating room management, complete with recommendations
    • Wachtel RE, Dexter F. Difficulties and challenges associated with literature searches in operating room management, complete with recommendations. Anesth Analg 2013;117:1460-79
    • (2013) Anesth Analg , vol.117 , pp. 1460-1479
    • Wachtel, R.E.1    Dexter, F.2
  • 4
    • 72449201516 scopus 로고    scopus 로고
    • Tracking changes in cardiac output: Methodological considerations for the validation of monitoring devices
    • Squara P, Cecconi M, Rhodes A, Singer M, Chiche JD. Tracking changes in cardiac output: methodological considerations for the validation of monitoring devices. Intensive Care Med 2009;35:1801-8
    • (2009) Intensive Care Med , vol.35 , pp. 1801-1808
    • Squara, P.1    Cecconi, M.2    Rhodes, A.3    Singer, M.4    Chiche, J.D.5
  • 6
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986;1:307-10
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 11
    • 68849121782 scopus 로고    scopus 로고
    • Bench-To-bedside review: The importance of the precision of the reference technique in method comparison studies-with specific reference to the measurement of cardiac output
    • Cecconi M, Rhodes A, Poloniecki J, Della Rocca G, Grounds RM. Bench-To-bedside review: the importance of the precision of the reference technique in method comparison studies-with specific reference to the measurement of cardiac output. Crit Care 2009;13:201
    • (2009) Crit Care , vol.13 , pp. 201
    • Cecconi, M.1    Rhodes, A.2    Poloniecki, J.3    Della Rocca, G.4    Grounds, R.M.5
  • 12
    • 79957736830 scopus 로고    scopus 로고
    • Assessment of trending ability of cardiac output monitors by polar plot methodology
    • Critchley LA, Yang XX, Lee A. Assessment of trending ability of cardiac output monitors by polar plot methodology. J Cardiothorac Vasc Anesth 2011;25:536-46
    • (2011) J Cardiothorac Vasc Anesth , vol.25 , pp. 536-546
    • Critchley, L.A.1    Yang, X.X.2    Lee, A.3
  • 14
    • 0038293048 scopus 로고    scopus 로고
    • A computer program for interpreting pulmonary artery catheterization data: Results of the European HEMODYN Resident Study
    • Squara P, Fourquet E, Jacquet L, Broccard A, Uhlig T, Rhodes A, Bakker J, Perret C. A computer program for interpreting pulmonary artery catheterization data: results of the European HEMODYN Resident Study. Intensive Care Med 2003;29:735-41
    • (2003) Intensive Care Med , vol.29 , pp. 735-741
    • Squara, P.1    Fourquet, E.2    Jacquet, L.3    Broccard, A.4    Uhlig, T.5    Rhodes, A.6    Bakker, J.7    Perret, C.8
  • 15
    • 52949104040 scopus 로고    scopus 로고
    • A randomised, controlled trial of conventional versus automated weaning from mechanical ventilation using SmartCare/PS
    • Rose L, Presneill JJ, Johnston L, Cade JF. A randomised, controlled trial of conventional versus automated weaning from mechanical ventilation using SmartCare/PS. Intensive Care Med 2008;34:1788-95
    • (2008) Intensive Care Med , vol.34 , pp. 1788-1795
    • Rose, L.1    Presneill, J.J.2    Johnston, L.3    Cade, J.F.4
  • 16
    • 84862519832 scopus 로고    scopus 로고
    • Safety and efficacy of a fully closed-loop control ventilation (IntelliVent-ASV®) in sedated ICU patients with acute respiratory failure: A prospective randomized crossover study
    • Arnal JM, Wysocki M, Novotni D, Demory D, Lopez R, Donati S, Granier I, Corno G, Durand-Gasselin J. Safety and efficacy of a fully closed-loop control ventilation (IntelliVent-ASV®) in sedated ICU patients with acute respiratory failure: a prospective randomized crossover study. Intensive Care Med 2012;38:781-7
    • (2012) Intensive Care Med , vol.38 , pp. 781-787
    • Arnal, J.M.1    Wysocki, M.2    Novotni, D.3    Demory, D.4    Lopez, R.5    Donati, S.6    Granier, I.7    Corno, G.8    Durand-Gasselin, J.9
  • 18
    • 84894086721 scopus 로고    scopus 로고
    • Are closed-loop systems for intensive insulin therapy ready for prime time in the ICU?
    • Okabayashi T, Shima Y. Are closed-loop systems for intensive insulin therapy ready for prime time in the ICU? Curr Opin Clin Nutr Metab Care 2014;17:190-9
    • (2014) Curr Opin Clin Nutr Metab Care , vol.17 , pp. 190-199
    • Okabayashi, T.1    Shima, Y.2
  • 19
    • 0032884749 scopus 로고    scopus 로고
    • Measuring agreement in method comparison studies
    • Bland JM, Altman DG. Measuring agreement in method comparison studies. Stat Methods Med Res 1999;8:135-60
    • (1999) Stat Methods Med Res , vol.8 , pp. 135-160
    • Bland, J.M.1    Altman, D.G.2
  • 20
    • 34447259097 scopus 로고    scopus 로고
    • Glucose monitoring technologies for the intensive care unit
    • Imhoff M. Glucose monitoring technologies for the intensive care unit. Care Critically Ill 2007;23:65-76
    • (2007) Care Critically Ill , vol.23 , pp. 65-76
    • Imhoff, M.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.