메뉴 건너뛰기




Volumn 43, Issue 5, 2015, Pages 578-587

Extraction of frequency domain dielectric characteristic parameter of oil-paper insulation for transformer condition assessment

Author keywords

characteristic parameters; condition assessment; dielectric dissipation factor; frequency domain spectroscopy; imaginary part of relative permittivity; oil paper insulation; power transformer

Indexed keywords

FREQUENCY DOMAIN ANALYSIS; INSULATION; MOISTURE; MOISTURE DETERMINATION; OIL FILLED TRANSFORMERS; PERMITTIVITY; POWER TRANSFORMERS;

EID: 84923816678     PISSN: 15325008     EISSN: 15325016     Source Type: Journal    
DOI: 10.1080/15325008.2014.989377     Document Type: Article
Times cited : (13)

References (32)
  • 1
    • 35348892705 scopus 로고    scopus 로고
    • Impact of temperature on the frequency domain dielectric spectroscopy for the diagnosis of power transformer insulation
    • Montreal, Canada, 18-22 June
    • Yew, J. H., Saha, T. K., and Thomas, A., "Impact of temperature on the frequency domain dielectric spectroscopy for the diagnosis of power transformer insulation," Proceedings of the IEEE Power Engineering Society General Meeting, pp. 1-7, Montreal, Canada, 18-22 June 2006
    • (2006) Proceedings of the IEEE Power Engineering Society General Meeting , pp. 1-7
    • Yew, J.H.1    Saha, T.K.2    Thomas, A.3
  • 2
    • 84856920587 scopus 로고    scopus 로고
    • Influence of artificial thermal aging on transformer oil properties
    • Abdi, S., Boubakeur, A., Haddad, A., and Harid, N., "Influence of artificial thermal aging on transformer oil properties," Electr. Power Compon. Syst., Vol. 39, No. 15, pp. 1701-1711, 2011
    • (2011) Electr. Power Compon. Syst. , vol.39 , Issue.15 , pp. 1701-1711
    • Abdi, S.1    Boubakeur, A.2    Haddad, A.3    Harid, N.4
  • 4
    • 43249127875 scopus 로고    scopus 로고
    • Study on generation rate of characteristic products of oil-paper insulation aging
    • in Chinese
    • Liao, R. J., Feng, Y., Yang, L. J., Xiang, B., and Liu, G., "Study on generation rate of characteristic products of oil-paper insulation aging," Proc. CSEE, Vol. 28, No. 10, pp. 142-147, 2008 (in Chinese)
    • (2008) Proc. CSEE , vol.28 , Issue.10 , pp. 142-147
    • Liao, R.J.1    Feng, Y.2    Yang, L.J.3    Xiang, B.4    Liu, G.5
  • 6
    • 84863178401 scopus 로고    scopus 로고
    • Quantitative analysis ageing status of natural ester-paper insulation and mineral oil-paper insulation by polarization/depolarization current
    • Hao, J., Liao, R. J., Chen, G., Ma, Z. Q., and Yang, L. J., "Quantitative analysis ageing status of natural ester-paper insulation and mineral oil-paper insulation by polarization/depolarization current," IEEE Trans. Dielectr. Electr. Insulat., Vol. 19, No. 1, pp. 188-199, 2012
    • (2012) IEEE Trans. Dielectr. Electr. Insulat. , vol.19 , Issue.1 , pp. 188-199
    • Hao, J.1    Liao, R.J.2    Chen, G.3    Ma, Z.Q.4    Yang, L.J.5
  • 7
    • 79961156537 scopus 로고    scopus 로고
    • Experimental investigation using accelerated aging factors on dielectric properties of transformer insulating oil
    • Singh, J., Sood, Y. R., and Verma, P., "Experimental investigation using accelerated aging factors on dielectric properties of transformer insulating oil," Electr. Power Compon. Syst., Vol. 39, No. 11, pp. 1045-1059, 2011
    • (2011) Electr. Power Compon. Syst. , vol.39 , Issue.11 , pp. 1045-1059
    • Singh, J.1    Sood, Y.R.2    Verma, P.3
  • 8
    • 0028496219 scopus 로고
    • Review of chemical indicators of degradation of cellulosic electrical paper insulation in oil-filled transformers
    • Emsley, A. M., and Stevens, G. C., "Review of chemical indicators of degradation of cellulosic electrical paper insulation in oil-filled transformers," IEE Proc. Sci. Meas. Technol., Vol. 141, No. 5, p. 324, 1994
    • (1994) IEE Proc. Sci. Meas. Technol. , vol.141 , Issue.5 , pp. 324
    • Emsley, A.M.1    Stevens, G.C.2
  • 9
    • 0344465271 scopus 로고    scopus 로고
    • Review of modern diagnostic techniques for assessing insulation condition in aged transformers
    • Saha, T. K., "Review of modern diagnostic techniques for assessing insulation condition in aged transformers," IEEE Trans. Dielectr. Electr. Insul., Vol. 10, No. 5, pp. 903-917, 2003
    • (2003) IEEE Trans. Dielectr. Electr. Insul. , vol.10 , Issue.5 , pp. 903-917
    • Saha, T.K.1
  • 10
    • 79960605561 scopus 로고    scopus 로고
    • Microstructure and electrical performance of oil-immersed insulation paper under partial discharge
    • in Chinese
    • Yan, J. M., Liao, R. J., and Yang, L. J., "Microstructure and electrical performance of oil-immersed insulation paper under partial discharge," Proc. CSEE., Vol. 31, No. 19, pp. 114-121, 2011 (in Chinese)
    • (2011) Proc. CSEE. , vol.31 , Issue.19 , pp. 114-121
    • Yan, J.M.1    Liao, R.J.2    Yang, L.J.3
  • 12
    • 0020942147 scopus 로고
    • Moisture equilibrium in paper-oil systems
    • Chicago, IL, 3-6 October
    • Oommen, T. V., "Moisture equilibrium in paper-oil systems," Electrical/Electronics Insulation Conference, pp. 162-166, Chicago, IL, 3-6 October 1983
    • (1983) Electrical/Electronics Insulation Conference , pp. 162-166
    • Oommen, T.V.1
  • 14
    • 17744364901 scopus 로고    scopus 로고
    • A moisturein-oil model for power transformer monitoring-Part I: Theoretical foundation
    • Garcia, B., Burgos, J. C., Alonso, A., and Sanz, J., "A moisturein-oil model for power transformer monitoring-Part I: Theoretical foundation," IEEE Trans. Power Deliv., Vol. 20, No. 2, pp. 1417-1422, 2005
    • (2005) IEEE Trans. Power Deliv. , vol.20 , Issue.2 , pp. 1417-1422
    • Garcia, B.1    Burgos, J.C.2    Alonso, A.3    Sanz, J.4
  • 15
    • 17744368516 scopus 로고    scopus 로고
    • A moisturein-oil model for power transformer monitoring-Part II: Experimental verification
    • Garcia, B., Burgos, J. C., Alonso, A., and Sanz, J., "A moisturein-oil model for power transformer monitoring-Part II: Experimental verification," IEEE Trans. Power Deliv., Vol. 20, No. 2, pp. 1423-1429, 2005
    • (2005) IEEE Trans. Power Deliv. , vol.20 , Issue.2 , pp. 1423-1429
    • Garcia, B.1    Burgos, J.C.2    Alonso, A.3    Sanz, J.4
  • 16
    • 0032314710 scopus 로고    scopus 로고
    • Measurement of moisture diffusion as a function of temperature and moisture concentration in transformer pressboard
    • Atlanta, GA, 25-28 October
    • Du, Y., Mamishev, A. V., Lesieutre, B. C., and Zahn, M., "Measurement of moisture diffusion as a function of temperature and moisture concentration in transformer pressboard," Conference on Electrical Insulation and Dielectric Phenomena (CEIDP), pp. 341-344, Atlanta, GA, 25-28 October 1998
    • (1998) Conference on Electrical Insulation and Dielectric Phenomena (CEIDP) , pp. 341-344
    • Du, Y.1    Mamishev, A.V.2    Lesieutre, B.C.3    Zahn, M.4
  • 17
    • 33745634614 scopus 로고    scopus 로고
    • Frequency response of oil impregnated pressboard and paper samples for estimating moisture in transformer insulation
    • Ekanayake, C.,Gubanski, S. M., Graczkowski, A., andWalczak, K., "Frequency response of oil impregnated pressboard and paper samples for estimating moisture in transformer insulation," IEEE Trans. Power Deliv., Vol. 21, No. 3, pp. 1309-1317, 2006
    • (2006) IEEE Trans. Power Deliv. , vol.21 , Issue.3 , pp. 1309-1317
    • Ekanayake, C.1    Gubanski, S.M.2    Graczkowski, A.3    Andwalczak, K.4
  • 18
    • 0037250619 scopus 로고    scopus 로고
    • Experience with return voltage measurements for assessing insulation conditions in serviceaged transformers
    • Saha, T. K., and Zheng, T. Y., "Experience with return voltage measurements for assessing insulation conditions in serviceaged transformers," IEEE Trans. Power Deliv., Vol. 18, No. 1, pp. 128-135, 2003
    • (2003) IEEE Trans. Power Deliv. , vol.18 , Issue.1 , pp. 128-135
    • Saha, T.K.1    Zheng, T.Y.2
  • 19
    • 0032306820 scopus 로고    scopus 로고
    • Practical foundations of the RVM (recovery voltage method for oil/paper insulation diagnosis)
    • Atlanta, GA
    • Csepes, G., Hamos, I., Brooks, R., and Karius, V., "Practical foundations of the RVM (recovery voltage method for oil/paper insulation diagnosis)," IEEE Conf. Elect. Insul. Dielectr. Phenomena, Vol. 1, pp. 345-355, Atlanta, GA, 1998
    • (1998) IEEE Conf. Elect. Insul. Dielectr. Phenomena , vol.1 , pp. 345-355
    • Csepes, G.1    Hamos, I.2    Brooks, R.3    Karius, V.4
  • 20
    • 0036076082 scopus 로고    scopus 로고
    • Insulation diagnostics on power transformers using the polarization and depolarization current (PDC) analysis
    • Boston, MA, 7-10 April
    • Leibfried, T., and Kachler, A. J., "Insulation diagnostics on power transformers using the polarization and depolarization current (PDC) analysis," 2002 IEEE International Symposium on Electrical Insulation, pp. 170-173, Boston, MA, 7-10 April 2002
    • (2002) 2002 IEEE International Symposium on Electrical Insulation , pp. 170-173
    • Leibfried, T.1    Kachler, A.J.2
  • 21
    • 1842529229 scopus 로고    scopus 로고
    • Investigation of polarization and depolarization current measurements for the assessment of oilpaper insulation of aged transformers
    • Saha, T. K., and Purkait, P., "Investigation of polarization and depolarization current measurements for the assessment of oilpaper insulation of aged transformers," IEEE Trans. Dielectr. Electr. Insulat., Vol. 11, No. 1, pp. 144-154, 2004
    • (2004) IEEE Trans. Dielectr. Electr. Insulat. , vol.11 , Issue.1 , pp. 144-154
    • Saha, T.K.1    Purkait, P.2
  • 22
    • 33646398368 scopus 로고    scopus 로고
    • Dielectric response studies on insulating system of high voltage rotating machines
    • Farahani, M., Borsi, H., and Gockenbach, E., "Dielectric response studies on insulating system of high voltage rotating machines," IEEE Trans. Dielectr. Electr. Insulat., Vol. 13, No. 2, pp. 383-393, 2006
    • (2006) IEEE Trans. Dielectr. Electr. Insulat. , vol.13 , Issue.2 , pp. 383-393
    • Farahani, M.1    Borsi, H.2    Gockenbach, E.3
  • 23
    • 1242330865 scopus 로고    scopus 로고
    • Applications of dielectric spectroscopy in time and frequency domain for HV power equipment
    • Zaengl, W. S., "Applications of dielectric spectroscopy in time and frequency domain for HV power equipment," IEEE Electr. Insulat. Mag., Vol. 19, No. 6, pp. 9-22, 2003
    • (2003) IEEE Electr. Insulat. Mag. , vol.19 , Issue.6 , pp. 9-22
    • Zaengl, W.S.1
  • 24
    • 33847704075 scopus 로고    scopus 로고
    • Dielectric response of mineral oil impregnated cellulose and the impact of aging
    • Linhjell, D., Lundgaard, L. E., and Gafvert, U., "Dielectric response of mineral oil impregnated cellulose and the impact of aging," IEEE Trans. Dielectr. Electr. Insulat., Vol. 14, No. 1, pp. 156-169, 2007
    • (2007) IEEE Trans. Dielectr. Electr. Insulat. , vol.14 , Issue.1 , pp. 156-169
    • Linhjell, D.1    Lundgaard, L.E.2    Gafvert, U.3
  • 25
    • 84872123341 scopus 로고    scopus 로고
    • Analysis of dielectric responsemeasurements for condition assessment of oil-paper transformer insulation
    • Koch,M., and Prevost, T., "Analysis of dielectric responsemeasurements for condition assessment of oil-paper transformer insulation," IEEE Trans. Dielectr. Electr. Insulat., Vol. 19, No. 6, pp. 1908-1915, 2012
    • (2012) IEEE Trans. Dielectr. Electr. Insulat. , vol.19 , Issue.6 , pp. 1908-1915
    • Koch, M.1    Prevost, T.2
  • 26
    • 42149108015 scopus 로고    scopus 로고
    • Understanding the impacts of moisture and thermal aging on transformer's insulation by dielectric response and molecular weight measurements
    • Saha, T. K., and Purkait, P., "Understanding the impacts of moisture and thermal aging on transformer's insulation by dielectric response and molecular weight measurements," IEEE Trans. Dielectr. Electr. Insulat., Vol. 15, No. 2, pp. 568-582, 2008
    • (2008) IEEE Trans. Dielectr. Electr. Insulat. , vol.15 , Issue.2 , pp. 568-582
    • Saha, T.K.1    Purkait, P.2
  • 27
    • 84864105817 scopus 로고    scopus 로고
    • Relationship between frequency domain dielectric characteristic quantity and aging status of transformer oil-paper insulation
    • in Chinese
    • Liao, R. J., Hao, J., Yang, L. J., Yuan, Q., and Tang, C., "Relationship between frequency domain dielectric characteristic quantity and aging status of transformer oil-paper insulation," Trans. China Electrotech. Soc. ., Vol. 27, No. 5, pp. 43-49, 2012 (in Chinese)
    • (2012) Trans. China Electrotech. Soc. . , vol.27 , Issue.5 , pp. 43-49
    • Liao, R.J.1    Hao, J.2    Yang, L.J.3    Yuan, Q.4    Tang, C.5
  • 28
    • 27744592802 scopus 로고    scopus 로고
    • The influence of levelling-off degree of polymerisation on the kinetics of cellulose degradation
    • Calvini, P., "The influence of levelling-off degree of polymerisation on the kinetics of cellulose degradation," Cellulose, Vol. 12, No. 4, pp. 445-447, 2005
    • (2005) Cellulose , vol.12 , Issue.4 , pp. 445-447
    • Calvini, P.1
  • 29
    • 0002777838 scopus 로고
    • Kinetics and mechanisms of the low-temperature degradation of cellulose
    • Emsley,A. M., and Stevens,G. C., "Kinetics and mechanisms of the low-temperature degradation of cellulose," Cellulose, Vol. 1, No. 1, pp. 26-56, 1994
    • (1994) Cellulose , vol.1 , Issue.1 , pp. 26-56
    • Emsley, A.M.1    Stevens, G.C.2
  • 30
    • 84864081861 scopus 로고    scopus 로고
    • Investigation of dielectric response characteristics of transformer oil-paper insulation-dielectric spectroscopy of acceleratedly thermal aging
    • in Chinese
    • Wei, J. L., Wang, S. Q., Peng, H. D., Dong, M., Zhang, G. J., Feng, Y. C., and Zheng, Y., "Investigation of dielectric response characteristics of transformer oil-paper insulation-dielectric spectroscopy of acceleratedly thermal aging," Trans. China Electrotechn. Soc., Vol. 27, No. 5, pp. 56-62, 2012 (in Chinese)
    • (2012) Trans. China Electrotechn. Soc. , vol.27 , Issue.5 , pp. 56-62
    • Wei, J.L.1    Wang, S.Q.2    Peng, H.D.3    Dong, M.4    Zhang, G.J.5    Feng, Y.C.6    Zheng, Y.7
  • 32
    • 0242720703 scopus 로고    scopus 로고
    • Dielectric spectroscopy in time and frequency domain for HV power equipment, part I: Theoretical considerations
    • Zaengl, W. S., "Dielectric spectroscopy in time and frequency domain for HV power equipment, part I: Theoretical considerations," IEEE Electr. Insulat. Mag., Vol. 19, No. 5, pp. 5-19, 2003.
    • (2003) IEEE Electr. Insulat. Mag. , vol.19 , Issue.5 , pp. 5-19
    • Zaengl, W.S.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.