메뉴 건너뛰기




Volumn 62, Issue 2, 2015, Pages 159-163

A capacitance-to-frequency converter with on-chip passivated microelectrodes for bacteria detection in saline buffers up to 575 MHz

Author keywords

broadband GHz readout; CMOS capacitive biosensor; impedance spectroscopy; interdigitated electrodes

Indexed keywords

BACTERIA; CMOS INTEGRATED CIRCUITS; OXIDE SEMICONDUCTORS;

EID: 84923100722     PISSN: 15497747     EISSN: 15583791     Source Type: Journal    
DOI: 10.1109/TCSII.2014.2369111     Document Type: Article
Times cited : (37)

References (19)
  • 1
    • 67349115176 scopus 로고    scopus 로고
    • Interdigitated array microelectrodes based impedance biosensors for detection of bacterial cells
    • Jun.
    • M. Varshney and Y. Li, quot;Interdigitated array microelectrodes based impedance biosensors for detection of bacterial cells,quot; Biosensors Bioelectron., vol. 24, no. 10, pp. 2951-2960, Jun. 2009.
    • (2009) Biosensors Bioelectron. , vol.24 , Issue.10 , pp. 2951-2960
    • Varshney, M.1    Li, Y.2
  • 2
    • 33947713763 scopus 로고    scopus 로고
    • Interdigitated array microelectrode based impedance biosensor coupled with magnetic nanoparticle-antibody conjugates for detection of Escherichia coli O157:H7 in food samples
    • May
    • M. Varshney, quot;Interdigitated array microelectrode based impedance biosensor coupled with magnetic nanoparticle-antibody conjugates for detection of Escherichia coli O157:H7 in food samples,quot; Biosensors Bioelectron., vol. 22, no. 11, pp. 2408-2414, May 2007.
    • (2007) Biosensors Bioelectron. , vol.22 , Issue.11 , pp. 2408-2414
    • Varshney, M.1
  • 3
    • 38149044839 scopus 로고    scopus 로고
    • Electrical impedance spectroscopy for detection of bacterial cells in suspensions using interdigitated microelectrodes
    • Feb.
    • L. Yang, quot;Electrical impedance spectroscopy for detection of bacterial cells in suspensions using interdigitated microelectrodes,quot; Talanta, vol. 74, no. 5, pp. 1621-1629, Feb. 2008.
    • (2008) Talanta , vol.74 , Issue.5 , pp. 1621-1629
    • Yang, L.1
  • 4
    • 84922271489 scopus 로고    scopus 로고
    • Lytic enzymes as selectivity means for labelfree, microfluidic and impedimetric detection of whole-cell bacteria using ALD-Al2O3 passivated microelectrodes
    • to be published
    • N. Couniot et al., quot;Lytic enzymes as selectivity means for labelfree, microfluidic and impedimetric detection of whole-cell bacteria using ALD-Al2O3 passivated microelectrodes,quot; Biosensors Bioelectron., DOI:10.1016/j.bios.2014.07.084, to be published.
    • Biosensors Bioelectron.
    • Couniot, N.1
  • 6
    • 0035087692 scopus 로고    scopus 로고
    • Capacitive biosensors
    • C. Berggren and B. Bjarnason, quot;Capacitive biosensors,quot; Electroanalysis, vol. 13, no. 3, pp. 173-180, 2001.
    • (2001) Electroanalysis , vol.13 , Issue.3 , pp. 173-180
    • Berggren, C.1    Bjarnason, B.2
  • 7
    • 84896260072 scopus 로고    scopus 로고
    • A self-oscillating system to measure the conductivity and the permittivity of liquids within a single triangular signal
    • S. Druart, D. Flandre, and L. A. Francis, quot;A self-oscillating system to measure the conductivity and the permittivity of liquids within a single triangular signal,quot; J. Sensors, vol. 2014, no. 1-3, pp. 1-11, 2014.
    • (2014) J. Sensors , vol.2014 , Issue.1-3 , pp. 1-11
    • Druart, S.1    Flandre, D.2    Francis, L.A.3
  • 8
    • 33847264105 scopus 로고    scopus 로고
    • A CMOS capacitance sensor that monitors cell viability
    • S. B. Prakash and P. Abshire, quot;A CMOS capacitance sensor that monitors cell viability,quot; in Proc. IEEE Sensors Conf., 2005, pp. 1177-1180.
    • (2005) Proc. IEEE Sensors Conf. , pp. 1177-1180
    • Prakash, S.B.1    Abshire, P.2
  • 9
    • 84864580707 scopus 로고    scopus 로고
    • Integration of impedance spectroscopy sensors in a digital microfluidic platform
    • Aug.
    • T. Lederer, S. Clara, B. Jakoby, and W. Hilber, quot;Integration of impedance spectroscopy sensors in a digital microfluidic platform,quot; Microsyst. Technol., vol. 18, no. 7/8, pp. 1163-1180, Aug. 2012.
    • (2012) Microsyst. Technol. , vol.18 , Issue.7-8 , pp. 1163-1180
    • Lederer, T.1    Clara, S.2    Jakoby, B.3    Hilber, W.4
  • 10
    • 84892635854 scopus 로고    scopus 로고
    • A broadband biosensor interface IC for miniaturized dielectric spectroscopy from MHz to GHz
    • M. Bakhshiani, M. A. Suster, and P. Mohseni, quot;A broadband biosensor interface IC for miniaturized dielectric spectroscopy from MHz to GHz,quot; in Proc. IEEE CICC, 2013, pp. 1-4.
    • (2013) Proc. IEEE CICC , pp. 1-4
    • Bakhshiani, M.1    Suster, M.A.2    Mohseni, P.3
  • 11
    • 84893319409 scopus 로고    scopus 로고
    • A 1-50 GHz dielectric spectroscopy biosensor with integrated receiver front-end in 65 nm CMOS
    • J.-C. Chien, M. Anwar, E.-C. Yeh, L. P. Lee, and A. M. Niknejad, quot;A 1-50 GHz dielectric spectroscopy biosensor with integrated receiver front-end in 65 nm CMOS,quot; in Proc. IEEE MTT-S IMS, 2013, pp. 1-4.
    • (2013) Proc. IEEE MTT-S IMS , pp. 1-4
    • Chien, J.-C.1    Anwar, M.2    Yeh, E.-C.3    Lee, L.P.4    Niknejad, A.M.5
  • 12
    • 84883739873 scopus 로고    scopus 로고
    • A CMOS fractional-PLL-based microwave chemical sensor with 1.5 accuracy
    • Sep.
    • O. Elhadidy, M. Elkholy, A. A. Helmy, S. Palermo, and K. Entesari, quot;A CMOS fractional-PLL-based microwave chemical sensor with 1.5 accuracy,quot; IEEE Trans. Microw. Theory Techn., vol. 61, no. 9, pp. 3402-3416, Sep. 2013.
    • (2013) IEEE Trans. Microw. Theory Techn. , vol.61 , Issue.9 , pp. 3402-3416
    • Elhadidy, O.1    Elkholy, M.2    Helmy, A.A.3    Palermo, S.4    Entesari, K.5
  • 13
    • 84867399877 scopus 로고    scopus 로고
    • A self-sustained CMOS microwave chemical sensor using a frequency synthesizer
    • Oct.
    • A. A. Helmy et al., quot;A self-sustained CMOS microwave chemical sensor using a frequency synthesizer,quot; IEEE J. Solid-State Circuits, vol. 47, no. 10, pp. 2467-2483, Oct. 2012.
    • (2012) IEEE J. Solid-State Circuits , vol.47 , Issue.10 , pp. 2467-2483
    • Helmy, A.A.1
  • 14
    • 84923089862 scopus 로고    scopus 로고
    • A very high frequency capacitance-controlled oscillator for improved biosensing in high-salt solutions
    • Melbourne, Vic., Australia
    • N. Couniot, D. Bol, O. Poncelet, L. A. Francis, and D. Flandre, quot;A very high frequency capacitance-controlled oscillator for improved biosensing in high-salt solutions,quot; in Proc. Biosensors Conf., Melbourne, Vic., Australia, 2014.
    • (2014) Proc. Biosensors Conf.
    • Couniot, N.1    Bol, D.2    Poncelet, O.3    Francis, L.A.4    Flandre, D.5
  • 15
    • 34250737854 scopus 로고    scopus 로고
    • Dielectric characterization of bacterial cells using dielectrophoresis
    • A. Sanchis et al., quot;Dielectric characterization of bacterial cells using dielectrophoresis,quot; Bioelectromagnetics, vol. 28, no. 5, pp. 393-401, 2007.
    • (2007) Bioelectromagnetics , vol.28 , Issue.5 , pp. 393-401
    • Sanchis, A.1
  • 16
    • 84862777585 scopus 로고    scopus 로고
    • Al2O3 and TiO2 atomic layer deposition on copper for water corrosion resistance
    • A. I. Abdulagatov et al., quot;Al2O3 and TiO2 atomic layer deposition on copper for water corrosion resistance,quot; ACS Appl. Mater. Interfaces, vol. 3, no. 12, pp. 4593-4601, 2011.
    • (2011) ACS Appl. Mater. Interfaces , vol.3 , Issue.12 , pp. 4593-4601
    • Abdulagatov, A.I.1
  • 17
    • 84887031239 scopus 로고    scopus 로고
    • Signal-to-noise ratio optimization for detecting bacteria with interdigitated microelectrodes
    • Dec.
    • N. Couniot, D. Flandre, L. A. Francis, and A. Afzalian, quot;Signal-to-noise ratio optimization for detecting bacteria with interdigitated microelectrodes,quot; Sensors Actuators B, Chem., vol. 189, pp. 43-51, Dec. 2013.
    • (2013) Sensors Actuators B, Chem. , vol.189 , pp. 43-51
    • Couniot, N.1    Flandre, D.2    Francis, L.A.3    Afzalian, A.4
  • 18
    • 54749134679 scopus 로고    scopus 로고
    • Detection of Escherichia coli and Salmonella typhimurium using interdigitated microelectrode capacitive immunosensors: The importance of transducer geometry
    • O. Laczka, E. Baldrich, F. X. Muñoz, and F. J. del Campo, quot;Detection of Escherichia coli and Salmonella typhimurium using interdigitated microelectrode capacitive immunosensors: The importance of transducer geometry,quot; Anal. Chem., vol. 80, no. 19, pp. 7239-7247, 2008.
    • (2008) Anal. Chem. , vol.80 , Issue.19 , pp. 7239-7247
    • Laczka, O.1    Baldrich, E.2    Muñoz, F.X.3    Del Campo, F.J.4
  • 19
    • 84908668738 scopus 로고    scopus 로고
    • Assessment of different functionalization methods for grafting a protein to an alumina-covered biosensor
    • N. Van Overstraeten-Schlögel, O. Lefèvre, N. Couniot, and D. Flandre, quot;Assessment of different functionalization methods for grafting a protein to an alumina-covered biosensor,quot; Biofabrication, vol. 6, no. 3, 2014, Art. ID. 035007.
    • (2014) Biofabrication , vol.6 , Issue.3
    • Van Overstraeten-Schlögel, N.1    Lefèvre, O.2    Couniot, N.3    Flandre, D.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.