메뉴 건너뛰기




Volumn 38, Issue 12, 2014, Pages 1007-1017

Effect of impeller design and spacing on gas exchange in a percutaneous respiratory assist catheter

Author keywords

Acute respiratory distress syndrome; Artificial lungs; Blood oxygenator; Chronic obstructive pulmonary disease; CO2 removal; Gas exchange; Impeller design

Indexed keywords

ARTIFICIAL ORGANS; BIOLOGICAL ORGANS; CARBON DIOXIDE; CATHETERS; COMPUTATIONAL FLUID DYNAMICS; DEIONIZED WATER; DESIGN; GASES; OXYGENATORS; PULMONARY DISEASES;

EID: 84923079970     PISSN: 0160564X     EISSN: 15251594     Source Type: Journal    
DOI: 10.1111/aor.12308     Document Type: Article
Times cited : (11)

References (35)
  • 1
    • 84867949485 scopus 로고    scopus 로고
    • Extracorporeal carbon dioxide removal: the future of lung support lies in the history
    • Kaushik M, Wojewodzka-Zelezniakowicz M, Cruz DN, etal. Extracorporeal carbon dioxide removal: the future of lung support lies in the history. Blood Purif 2012;34:94-106.
    • (2012) Blood Purif , vol.34 , pp. 94-106
    • Kaushik, M.1    Wojewodzka-Zelezniakowicz, M.2    Cruz, D.N.3
  • 3
    • 39049149884 scopus 로고    scopus 로고
    • Outcome of patients undergoing prolonged mechanical ventilation after critical illness
    • Bigatello LM, Stelfox HT, Berra L, Schmidt U, Gettings EM. Outcome of patients undergoing prolonged mechanical ventilation after critical illness. Crit Care Med 2007;35:2491-2497.
    • (2007) Crit Care Med , vol.35 , pp. 2491-2497
    • Bigatello, L.M.1    Stelfox, H.T.2    Berra, L.3    Schmidt, U.4    Gettings, E.M.5
  • 4
    • 78650327545 scopus 로고    scopus 로고
    • Carbon dioxide dialysis will save the lung
    • Pesenti A, Patroniti N, Fumagalli R. Carbon dioxide dialysis will save the lung. Crit Care Med 2010;38(Suppl. 10):S549-554.
    • (2010) Crit Care Med , vol.38 , pp. S549-S554
    • Pesenti, A.1    Patroniti, N.2    Fumagalli, R.3
  • 5
    • 33746926811 scopus 로고    scopus 로고
    • Venoarterial extracorporeal membrane oxygenation (VA-ECMO) in pediatric cardiac support
    • Thourani VH, Kisrhbom PM, Kanter KR, etal. Venoarterial extracorporeal membrane oxygenation (VA-ECMO) in pediatric cardiac support. Ann Thorac Surg 2006;82:138-145.
    • (2006) Ann Thorac Surg , vol.82 , pp. 138-145
    • Thourani, V.H.1    Kisrhbom, P.M.2    Kanter, K.R.3
  • 6
    • 84866881470 scopus 로고    scopus 로고
    • Bench-to-bedside review: extracorporeal carbon dioxide removal, past present and future
    • Cove M, MacLaren G, Federspiel W, Kellum J. Bench-to-bedside review: extracorporeal carbon dioxide removal, past present and future. Crit Care 2012;16:232.
    • (2012) Crit Care , vol.16 , pp. 232
    • Cove, M.1    MacLaren, G.2    Federspiel, W.3    Kellum, J.4
  • 7
    • 0343893748 scopus 로고    scopus 로고
    • Ventilation with lower tidal volumes as compared with traditional tidal volumes for acute lung injury and the acute respiratory distress syndrome
    • Brower RG, Matthay MA, Morris A, Schoenfeld D, Thompson BT, Wheeler A. Ventilation with lower tidal volumes as compared with traditional tidal volumes for acute lung injury and the acute respiratory distress syndrome. N Engl J Med 2000;342:1301-1308.
    • (2000) N Engl J Med , vol.342 , pp. 1301-1308
    • Brower, R.G.1    Matthay, M.A.2    Morris, A.3    Schoenfeld, D.4    Thompson, B.T.5    Wheeler, A.6
  • 9
    • 79957631314 scopus 로고    scopus 로고
    • Respiratory dialysis: reduction in dependence on mechanical ventilation by venovenous extracorporeal CO2 removal
    • Batchinsky AI, Jordan BS, Regn D, etal. Respiratory dialysis: reduction in dependence on mechanical ventilation by venovenous extracorporeal CO2 removal. Crit Care Med 2011;1:1382-1387.
    • (2011) Crit Care Med , vol.1 , pp. 1382-1387
    • Batchinsky, A.I.1    Jordan, B.S.2    Regn, D.3
  • 10
    • 34247112987 scopus 로고    scopus 로고
    • Lung, artificial: current research and future directions
    • In: Wnek GE, Bowlin GL, eds. . New York: Marcel Dekker
    • Federspiel WJ, Svitek RG. Lung, artificial: current research and future directions. In: Wnek GE, Bowlin GL, eds. Encyclopedia of Biomaterials and Biomedical Engineering. New York: Marcel Dekker, 2004;922-931.
    • (2004) Encyclopedia of Biomaterials and Biomedical Engineering , pp. 922-931
    • Federspiel, W.J.1    Svitek, R.G.2
  • 11
    • 0024321839 scopus 로고
    • Conceptual and design features of a practical, clinically effective intravenous mechanical blood oxygen/carbon dioxide exchange device (IVOX)
    • Mortensen JD, Berry G. Conceptual and design features of a practical, clinically effective intravenous mechanical blood oxygen/carbon dioxide exchange device (IVOX). Int J Artif Organs 1989;12:384-389.
    • (1989) Int J Artif Organs , vol.12 , pp. 384-389
    • Mortensen, J.D.1    Berry, G.2
  • 12
    • 0030250223 scopus 로고    scopus 로고
    • Acute in vivo studies of the Pittsburgh intravenous membrane oxygenator
    • Macha M, Federspiel WJ, Lund LW, etal. Acute in vivo studies of the Pittsburgh intravenous membrane oxygenator. ASAIO J 1996;42:M609-615.
    • (1996) ASAIO J , vol.42 , pp. M609-M615
    • Macha, M.1    Federspiel, W.J.2    Lund, L.W.3
  • 13
    • 0027426355 scopus 로고
    • A pumping intravascular artificial lung with active mixing
    • Makarewicz AJ, Mockros LF, Anderson RW. A pumping intravascular artificial lung with active mixing. ASAIO J 1993;39:M466-469.
    • (1993) ASAIO J , vol.39 , pp. M466-M469
    • Makarewicz, A.J.1    Mockros, L.F.2    Anderson, R.W.3
  • 14
    • 0028466205 scopus 로고
    • Small intrapulmonary artery lung prototypes: design, construction, and in vitro water testing
    • Snider MT, High KM, Richard RB, etal. Small intrapulmonary artery lung prototypes: design, construction, and in vitro water testing. ASAIO J 1994;40:M533-539.
    • (1994) ASAIO J , vol.40 , pp. M533-M539
    • Snider, M.T.1    High, K.M.2    Richard, R.B.3
  • 15
    • 4444226266 scopus 로고    scopus 로고
    • Compact intra- and extracorporeal oxygenator developments
    • Cattaneo G, Strauß A, Reul H. Compact intra- and extracorporeal oxygenator developments. Perfusion 2004;19:251-255.
    • (2004) Perfusion , vol.19 , pp. 251-255
    • Cattaneo, G.1    Strauß, A.2    Reul, H.3
  • 17
    • 0032601386 scopus 로고    scopus 로고
    • Intravascular membrane oxygenator and carbon dioxide removal devices: a review of performance and improvements
    • Zwischenberger JB, Tao W, Bidani A. Intravascular membrane oxygenator and carbon dioxide removal devices: a review of performance and improvements. ASAIO J 1999;45:41-46.
    • (1999) ASAIO J , vol.45 , pp. 41-46
    • Zwischenberger, J.B.1    Tao, W.2    Bidani, A.3
  • 18
    • 20544434358 scopus 로고    scopus 로고
    • Evaluation of local gas exchange in a pulsating respiratory support catheter
    • Eash HJ, Frankowski BJ, Hattler BG, Federspiel WJ. Evaluation of local gas exchange in a pulsating respiratory support catheter. ASAIO J 2005;51:152-157.
    • (2005) ASAIO J , vol.51 , pp. 152-157
    • Eash, H.J.1    Frankowski, B.J.2    Hattler, B.G.3    Federspiel, W.J.4
  • 19
    • 0028130334 scopus 로고
    • Major findings from the clinical trials of the intravascular oxygenator
    • Conrad SA, Bagley A, Bagley B, etal. Major findings from the clinical trials of the intravascular oxygenator. Artif Organs 1994;18:846-863.
    • (1994) Artif Organs , vol.18 , pp. 846-863
    • Conrad, S.A.1    Bagley, A.2    Bagley, B.3
  • 20
    • 0027434669 scopus 로고
    • Prolonged intracorporeal support of gas exchange with an intravenacaval oxygenator
    • Conrad SA, Eggerstedt JM, Morris VF, Romero MD. Prolonged intracorporeal support of gas exchange with an intravenacaval oxygenator. Chest 1993;103:158-161.
    • (1993) Chest , vol.103 , pp. 158-161
    • Conrad, S.A.1    Eggerstedt, J.M.2    Morris, V.F.3    Romero, M.D.4
  • 21
    • 34249037352 scopus 로고    scopus 로고
    • Evaluation of fiber bundle rotation for enhancing gas exchange in a respiratory assist catheter
    • Eash HJ, Mihelc KM, Frankowski BJ, Hattler BG, Federspiel WJ. Evaluation of fiber bundle rotation for enhancing gas exchange in a respiratory assist catheter. ASAIO J 2007;53:368-373.
    • (2007) ASAIO J , vol.53 , pp. 368-373
    • Eash, H.J.1    Mihelc, K.M.2    Frankowski, B.J.3    Hattler, B.G.4    Federspiel, W.J.5
  • 22
    • 73949136951 scopus 로고    scopus 로고
    • Evaluation of a respiratory assist catheter that uses an impeller within a hollow fiber membrane bundle
    • Mihelc KM, Frankowski BJ, Lieber SC, Moore ND, Hattler BG, Federspiel WJ. Evaluation of a respiratory assist catheter that uses an impeller within a hollow fiber membrane bundle. ASAIO J 2009;55:569-574.
    • (2009) ASAIO J , vol.55 , pp. 569-574
    • Mihelc, K.M.1    Frankowski, B.J.2    Lieber, S.C.3    Moore, N.D.4    Hattler, B.G.5    Federspiel, W.J.6
  • 23
    • 43449115078 scopus 로고    scopus 로고
    • 2 removal in hollow fiber membrane oxygenators
    • 2 removal in hollow fiber membrane oxygenators. Ann Biomed Eng 2008;36:992-1003.
    • (2008) Ann Biomed Eng , vol.36 , pp. 992-1003
    • Svitek, R.G.1    Federspiel, W.J.2
  • 24
    • 0002127397 scopus 로고
    • Fluid flow through packed columns
    • Ergun S. Fluid flow through packed columns. Chem Eng Prog 1952;49:89-94.
    • (1952) Chem Eng Prog , vol.49 , pp. 89-94
    • Ergun, S.1
  • 25
    • 80052694022 scopus 로고    scopus 로고
    • Darcy permeability of hollow fiber bundles used in blood oxygenation devices
    • Pacella HE, Eash HJ, Frankowski BJ, Federspiel WJ. Darcy permeability of hollow fiber bundles used in blood oxygenation devices. J Memb Sci 2011;382:238-242.
    • (2011) J Memb Sci , vol.382 , pp. 238-242
    • Pacella, H.E.1    Eash, H.J.2    Frankowski, B.J.3    Federspiel, W.J.4
  • 26
    • 0035985026 scopus 로고    scopus 로고
    • Predicting membrane oxygenator pressure drop using computational fluid dynamics
    • Gage KL, Gartner MJ, Burgreen GW, Wagner WR. Predicting membrane oxygenator pressure drop using computational fluid dynamics. Artif Organs 2002;26:600-607.
    • (2002) Artif Organs , vol.26 , pp. 600-607
    • Gage, K.L.1    Gartner, M.J.2    Burgreen, G.W.3    Wagner, W.R.4
  • 28
    • 33846636879 scopus 로고    scopus 로고
    • Characterization of membrane blood oxygenation devices using computational fluid dynamics
    • Zhang J, Nolan TDC, Zhang T, Griffith BP, Wu ZJ. Characterization of membrane blood oxygenation devices using computational fluid dynamics. J Memb Sci 2007;288:268-279.
    • (2007) J Memb Sci , vol.288 , pp. 268-279
    • Zhang, J.1    Nolan, T.D.C.2    Zhang, T.3    Griffith, B.P.4    Wu, Z.J.5
  • 31
    • 0028519103 scopus 로고
    • Use of a mathematical model to predict oxygen transfer rates in hollow fiber membrane oxygenators
    • Vaslef SN, Mockros LF, Anderson RW, Leonard RJ. Use of a mathematical model to predict oxygen transfer rates in hollow fiber membrane oxygenators. ASAIO J 1994;40:990-996.
    • (1994) ASAIO J , vol.40 , pp. 990-996
    • Vaslef, S.N.1    Mockros, L.F.2    Anderson, R.W.3    Leonard, R.J.4
  • 33
    • 79958827729 scopus 로고    scopus 로고
    • Computer-assisted numerical analysis for oxygen and carbon dioxide mass transfer in blood oxygenators
    • Turri F, Yanagihara JI. Computer-assisted numerical analysis for oxygen and carbon dioxide mass transfer in blood oxygenators. Artif Organs 2011;35:579-592.
    • (2011) Artif Organs , vol.35 , pp. 579-592
    • Turri, F.1    Yanagihara, J.I.2
  • 34
    • 0034824722 scopus 로고    scopus 로고
    • Blood trauma induced by clinically accepted oxygenators
    • Kawahito S, Maeda T, Yoshikawa M, etal. Blood trauma induced by clinically accepted oxygenators. ASAIO J 2001;47:492-495.
    • (2001) ASAIO J , vol.47 , pp. 492-495
    • Kawahito, S.1    Maeda, T.2    Yoshikawa, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.