메뉴 건너뛰기




Volumn 9, Issue 1, 2006, Pages 34-41

Design of an intravenous oxygenator

Author keywords

Dimensionless function; Gas transfer; Hollow fiber membrane; Intravenous oxygenator

Indexed keywords

WATER;

EID: 33645859021     PISSN: 14347229     EISSN: None     Source Type: Journal    
DOI: 10.1007/s10047-005-0312-1     Document Type: Article
Times cited : (12)

References (37)
  • 2
    • 0023100061 scopus 로고
    • An economic analysis of extracorporeal membrane oxygenation
    • GD Pearson BL Short 1986 An economic analysis of extracorporeal membrane oxygenation J Intensive Care Med 2 116 120
    • (1986) J Intensive Care Med , vol.2 , pp. 116-120
    • Pearson, G.D.1    Short, B.L.2
  • 4
    • 0028419986 scopus 로고
    • Changing criteria for the artificial lung: Historic controls on the technology of ECMO
    • TG Campell 1994 Changing criteria for the artificial lung: historic controls on the technology of ECMO ASAIO J 40 109 120
    • (1994) ASAIO J , vol.40 , pp. 109-120
    • Campell, T.G.1
  • 6
    • 0031975898 scopus 로고    scopus 로고
    • A mathematical model of gas exchange in an intravenous membrane oxygenator
    • TJ Hewitt BG Hattler WJ Federspiel 1998 A mathematical model of gas exchange in an intravenous membrane oxygenator Ann Biomed Eng 26 166 178
    • (1998) Ann Biomed Eng , vol.26 , pp. 166-178
    • Hewitt, T.J.1    Hattler, B.G.2    Federspiel, W.J.3
  • 8
    • 0030250228 scopus 로고    scopus 로고
    • Recent progress in engineering the Pittsburgh intravenous membrane oxygenator
    • WJ Federspiel TJ Hewitt MS Hout FR Walters 1996 Recent progress in engineering the Pittsburgh intravenous membrane oxygenator ASAIO J 42 M435 M442
    • (1996) ASAIO J , vol.42
    • Federspiel, W.J.1    Hewitt, T.J.2    Hout, M.S.3    Walters, F.R.4
  • 9
    • 0030199818 scopus 로고    scopus 로고
    • Gas flow dynamics in hollow-fiber membranes
    • 7
    • WJ Federspiel JL William BG Hattler 1996 Gas flow dynamics in hollow-fiber membranes AIChE J 42 7 2094 2099
    • (1996) AIChE J , vol.42 , pp. 2094-2099
    • Federspiel, W.J.1    William, J.L.2    Hattler, B.G.3
  • 11
  • 13
    • 33645845971 scopus 로고    scopus 로고
    • The evaluation of artificial lung using blood substitutes, J Biomed Eng
    • 3
    • KB Kim SC Lee SC Hong MH Kim GR Jheong 2000 The evaluation of artificial lung using blood substitutes, J Biomed Eng Res 21 3 311 320
    • (2000) Res , vol.21 , pp. 311-320
    • Kim, K.B.1    Lee, S.C.2    Hong, S.C.3    Kim, M.H.4    Jheong, G.R.5
  • 14
    • 0023369068 scopus 로고
    • An intravenacaval blood gas exchange (IVCBGE) device: A preliminary report
    • JD Mortensen 1987 An intravenacaval blood gas exchange (IVCBGE) device: a preliminary report Trans Am Soc Artif Intern Organs 33 570 573
    • (1987) Trans Am Soc Artif Intern Organs , vol.33 , pp. 570-573
    • Mortensen, J.D.1
  • 15
    • 0026566374 scopus 로고
    • Intravascular oxygenator: A new alternative method for augmenting blood gas transfer in patients with acute respiratory failure
    • JD Mortensen 1992 Intravascular oxygenator: a new alternative method for augmenting blood gas transfer in patients with acute respiratory failure Artif Organs 16 75 82
    • (1992) Artif Organs , vol.16 , pp. 75-82
    • Mortensen, J.D.1
  • 18
    • 27144549221 scopus 로고    scopus 로고
    • Enhancement of oxygen transfer in hollow fiber membrane by the vibration method
    • 4
    • GB Kim SJ Kim CU Hong TK Kwon NG Kim 2005 Enhancement of oxygen transfer in hollow fiber membrane by the vibration method Korean J Chem Eng 22 4 521 527
    • (2005) Korean J Chem Eng , vol.22 , pp. 521-527
    • Kim, G.B.1    Kim, S.J.2    Hong, C.U.3    Kwon, T.K.4    Kim, N.G.5
  • 19
    • 0015652160 scopus 로고
    • Rate of blood oxygenation in flat plate membrane oxygenator
    • S Katoh F Yoshida 1972 Rate of blood oxygenation in flat plate membrane oxygenator Chem Eng J 3 51 58
    • (1972) Chem Eng J , vol.3 , pp. 51-58
    • Katoh, S.1    Yoshida, F.2
  • 25
    • 0036022007 scopus 로고    scopus 로고
    • Mass transfer in blood oxygenators using blood analogue fluids
    • SR Wickramasinghe CM Kahr B Han 2002 Mass transfer in blood oxygenators using blood analogue fluids Biotechnol Prog 18 867
    • (2002) Biotechnol Prog , vol.18 , pp. 867
    • Wickramasinghe, S.R.1    Kahr, C.M.2    Han, B.3
  • 26
    • 33645857626 scopus 로고    scopus 로고
    • Characteristics of pressure drop and oxygen transfer in actuate hollow fiber membrane modules
    • 2
    • GB Kim JK Park TK Kwon SC Hong GR Jheong SC Lee 2002 Characteristics of pressure drop and oxygen transfer in actuate hollow fiber membrane modules Theories Appl Chem Eng 2 2 5070 5073
    • (2002) Theories Appl Chem Eng , vol.2 , pp. 5070-5073
    • Kim, G.B.1    Park, J.K.2    Kwon, T.K.3    Hong, S.C.4    Jheong, G.R.5    Lee, S.C.6
  • 27
    • 27144445717 scopus 로고    scopus 로고
    • Gas transfer and hemolysis characteristics of a new type intravenous lung assist device
    • 2
    • GB Kim TK Kwon GR Jheong SC Lee 2003 Gas transfer and hemolysis characteristics of a new type intravenous lung assist device J Biomed Eng Res 24 2 121 126
    • (2003) J Biomed Eng Res , vol.24 , pp. 121-126
    • Kim, G.B.1    Kwon, T.K.2    Jheong, G.R.3    Lee, S.C.4
  • 28
    • 33645861331 scopus 로고    scopus 로고
    • Evaluation on the characteristics of pressure drop for the design of intravascular articial lung assist device
    • 1
    • GB Kim TK Kwon JK Park GR Jheong SC Lee 2003 Evaluation on the characteristics of pressure drop for the design of intravascular articial lung assist device Membr J 13 1 20 28
    • (2003) Membr J , vol.13 , pp. 20-28
    • Kim, G.B.1    Kwon, T.K.2    Park, J.K.3    Jheong, G.R.4    Lee, S.C.5
  • 29
    • 33645856124 scopus 로고    scopus 로고
    • Study on the modeling technique for prediction about pressure drop of an intravenous lung assist device
    • 4
    • GB Kim TK Kwon GR Jheong 2003 Study on the modeling technique for prediction about pressure drop of an intravenous lung assist device J Biomed Eng Res 24 4 293 299
    • (2003) J Biomed Eng Res , vol.24 , pp. 293-299
    • Kim, G.B.1    Kwon, T.K.2    Jheong, G.R.3
  • 33
    • 27144445507 scopus 로고    scopus 로고
    • Liquid flow and pressure drop of an outside-flow membrane oxygenator with hollow fibers
    • 1
    • SC Lee KB Kim 2002 Liquid flow and pressure drop of an outside-flow membrane oxygenator with hollow fibers J Biomed Eng Res 23 1 27 31
    • (2002) J Biomed Eng Res , vol.23 , pp. 27-31
    • Lee, S.C.1    Kim, K.B.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.