-
1
-
-
73349129701
-
Advanced heart failure treated with continuous-flow left ventricular assist device
-
M.S. Slaughter, J.G. Rogers, and C.A. Milano Advanced heart failure treated with continuous-flow left ventricular assist device N Engl J Med 361 2009 22421 22451
-
(2009)
N Engl J Med
, vol.361
, pp. 22421-22451
-
-
Slaughter, M.S.1
Rogers, J.G.2
Milano, C.A.3
-
2
-
-
34548311569
-
Use of a continuous-flow device in patients awaiting heart transplantation
-
L.W. Miller, F.D. Pagani, and S.T. Russell Use of a continuous-flow device in patients awaiting heart transplantation N Engl J Med 357 2007 885 896
-
(2007)
N Engl J Med
, vol.357
, pp. 885-896
-
-
Miller, L.W.1
Pagani, F.D.2
Russell, S.T.3
-
3
-
-
28744446343
-
ACC/AHA 2005 guideline update for The diagnosis and management of chronic heart failure in The adult
-
A report of The American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Writing Committee to Update The 2001 Guidelines for The Evaluation and Management of Heart Failure): Developed in collaboration with The American College of Chest Physicians and The International Society for Heart and Lung Transplantation: Endorsed by The Heart Rhythm Society
-
S.A. Hunt, W.T. Abraham, and M.H. Chin ACC/AHA 2005 guideline update for The diagnosis and management of chronic heart failure in The adult: a report of The American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Writing Committee to Update The 2001 Guidelines for The Evaluation and Management of Heart Failure): developed in collaboration with The American College of Chest Physicians and The International Society for Heart and Lung Transplantation: endorsed by The Heart Rhythm Society Circulation 112 2005 e154 e235
-
(2005)
Circulation
, vol.112
, pp. e154-e235
-
-
Hunt, S.A.1
Abraham, W.T.2
Chin, M.H.3
-
4
-
-
0035892018
-
Long-term use of a left ventricular assist device for end-stage heart failure
-
E. Rose, A.C. Gelijns, and A.J. Moskowitz Long-term use of a left ventricular assist device for end-stage heart failure N Engl J Med 345 2001 1435 1443
-
(2001)
N Engl J Med
, vol.345
, pp. 1435-1443
-
-
Rose, E.1
Gelijns, A.C.2
Moskowitz, A.J.3
-
5
-
-
0035783884
-
HeartMate LILVAS. Multicenter clinical evaluation of The HeartMate vented electric left ventricular assist system in patients awaiting heart transplantation
-
O.H. Frazier, E.A. Rose, and M.C. Oz HeartMate LILVAS. Multicenter clinical evaluation of The HeartMate vented electric left ventricular assist system in patients awaiting heart transplantation J Thorac Cardiovasc Surg 122 2001 1186 1195
-
(2001)
J Thorac Cardiovasc Surg
, vol.122
, pp. 1186-1195
-
-
Frazier, O.H.1
Rose, E.A.2
Oz, M.C.3
-
6
-
-
79959452035
-
Current trends in implantable left ventricular assist devices
-
Garbade J, Bittner HB, Barten MJ, et al. Current trends in implantable left ventricular assist devices. Cardiol Res Pract 2011;2011:290561
-
(2011)
Cardiol Res Pract
, vol.2011
, pp. 290561
-
-
Garbade, J.1
Bittner, H.B.2
Barten, M.J.3
-
7
-
-
84871392445
-
Axial and centrifugal continuous-flow rotary pumps: A translation from pump mechanics to clinical practice
-
N. Moazami, K. Fukamachi, and M. Kobayashi Axial and centrifugal continuous-flow rotary pumps: a translation from pump mechanics to clinical practice J Heart Lung Transplant 32 2013 1 11
-
(2013)
J Heart Lung Transplant
, vol.32
, pp. 1-11
-
-
Moazami, N.1
Fukamachi, K.2
Kobayashi, M.3
-
8
-
-
0020072117
-
Comparative clinical study of pulsatile and nonpulsatile perfusion in 350 consecutive patients
-
K.M. Taylor, W.H. Bain, and K.G. Davidson Comparative clinical study of pulsatile and nonpulsatile perfusion in 350 consecutive patients Thorax 37 1982 324 330
-
(1982)
Thorax
, vol.37
, pp. 324-330
-
-
Taylor, K.M.1
Bain, W.H.2
Davidson, K.G.3
-
9
-
-
77958022676
-
Improved left ventricular unloading and circulatory support with synchronized pulsatile left ventricular assistance compared with continuous-flow left ventricular assistance in an acute porcine left ventricular failure model
-
G.V. Letsou, T.D. Pate, and J.R. Gohean Improved left ventricular unloading and circulatory support with synchronized pulsatile left ventricular assistance compared with continuous-flow left ventricular assistance in an acute porcine left ventricular failure model J Thorac Cardiovasc Surg 140 2010 1181 1188
-
(2010)
J Thorac Cardiovasc Surg
, vol.140
, pp. 1181-1188
-
-
Letsou, G.V.1
Pate, T.D.2
Gohean, J.R.3
-
10
-
-
0023324984
-
Pro: Pulsatile flow is preferable to nonpulsatile flow during cardiopulmonary bypass
-
K. Shevde, and W.K. DeBois Pro: Pulsatile flow is preferable to nonpulsatile flow during cardiopulmonary bypass J Cardiothorac Anesth 1 1987 165 168
-
(1987)
J Cardiothorac Anesth
, vol.1
, pp. 165-168
-
-
Shevde, K.1
Debois, W.K.2
-
11
-
-
0023324981
-
Con: Nonpulsatile flow is preferable to pulsatile flow during cardiopulmonary surgery
-
D.C. Findlayson Con: Nonpulsatile flow is preferable to pulsatile flow during cardiopulmonary surgery J Cardiothorac Anesth 1 1987 169 170
-
(1987)
J Cardiothorac Anesth
, vol.1
, pp. 169-170
-
-
Findlayson, D.C.1
-
12
-
-
0024534383
-
Cerebral autoregulation dynamics in humans
-
R. Aaslid, K.F. Lindegaard, and W. Sorteberg Cerebral autoregulation dynamics in humans Stroke 20 1989 45 52
-
(1989)
Stroke
, vol.20
, pp. 45-52
-
-
Aaslid, R.1
Lindegaard, K.F.2
Sorteberg, W.3
-
13
-
-
70349242127
-
Monitoring of cerebrovascular autoregulation: Facts, myths, and missing links
-
M. Czosnyka, K. Brady, and M. Reinhard Monitoring of cerebrovascular autoregulation: facts, myths, and missing links Neurocrit Care 10 2009 373 386
-
(2009)
Neurocrit Care
, vol.10
, pp. 373-386
-
-
Czosnyka, M.1
Brady, K.2
Reinhard, M.3
-
14
-
-
84865261933
-
Risks for impaired cerebral autoregulation during cardiopulmonary bypass and postoperative stroke
-
M. Ono, B. Joshi, and K. Brady Risks for impaired cerebral autoregulation during cardiopulmonary bypass and postoperative stroke Br J Anaesth 109 2012 391 398
-
(2012)
Br J Anaesth
, vol.109
, pp. 391-398
-
-
Ono, M.1
Joshi, B.2
Brady, K.3
-
15
-
-
0141469033
-
Adverse cerebral outcomes after coronary bypass surgery
-
G.W. Roach, M. Kanchuger, and C.M. Mangano Adverse cerebral outcomes after coronary bypass surgery N Engl J Med 335 1996 1857 1863
-
(1996)
N Engl J Med
, vol.335
, pp. 1857-1863
-
-
Roach, G.W.1
Kanchuger, M.2
Mangano, C.M.3
-
16
-
-
84877249172
-
Sympathetic neural and hemodynamic responses to upright tilt in patients with pulsatile and nonpulsatile left ventricular assist devices
-
D.W. Markham, Q. Fu, and M.D. Palmer Sympathetic neural and hemodynamic responses to upright tilt in patients with pulsatile and nonpulsatile left ventricular assist devices Circ Heart Fail 6 2013 293 299
-
(2013)
Circ Heart Fail
, vol.6
, pp. 293-299
-
-
Markham, D.W.1
Fu, Q.2
Palmer, M.D.3
-
17
-
-
67349185641
-
Assessment of arterial blood pressure during support with an axial flow left ventricular assist device
-
T.J. Myers, M. Bolmers, and I.D. Gregoric Assessment of arterial blood pressure during support with an axial flow left ventricular assist device J Heart Lung Transplant 28 2009 423 427
-
(2009)
J Heart Lung Transplant
, vol.28
, pp. 423-427
-
-
Myers, T.J.1
Bolmers, M.2
Gregoric, I.D.3
-
18
-
-
0037129864
-
Initial clinical experience with The Jarvik 2000 implantable axial-flow left ventricular assist system
-
O.H. Frazier, T.J. Myers, and I.D. Gregoric Initial clinical experience with The Jarvik 2000 implantable axial-flow left ventricular assist system Circulation 105 2002 2855 2860
-
(2002)
Circulation
, vol.105
, pp. 2855-2860
-
-
Frazier, O.H.1
Myers, T.J.2
Gregoric, I.D.3
-
19
-
-
70450285112
-
Preservation of endothelium nitric oxide release by pulsatile flow cardiopulmonary bypass when compared with continuous flow
-
E. Lanzarone, F. Gelmini, and M. Tessari Preservation of endothelium nitric oxide release by pulsatile flow cardiopulmonary bypass when compared with continuous flow Artif Organs 33 2009 926 934
-
(2009)
Artif Organs
, vol.33
, pp. 926-934
-
-
Lanzarone, E.1
Gelmini, F.2
Tessari, M.3
-
20
-
-
0025743845
-
Release of endothelium-derived relaxing factor is modulated by both frequency and amplitude of pulsatile flow
-
I.R. Hutcheson, and T.M. Griffith Release of endothelium-derived relaxing factor is modulated by both frequency and amplitude of pulsatile flow Am J Physiol 261 1991 H257 H262
-
(1991)
Am J Physiol
, vol.261
, pp. H257-H262
-
-
Hutcheson, I.R.1
Griffith, T.M.2
-
21
-
-
0034538382
-
Effect of inhibition of nitric oxide synthase on dynamic cerebral autoregulation in humans
-
R.P. White, P. Vallance, and H.S. Markus Effect of inhibition of nitric oxide synthase on dynamic cerebral autoregulation in humans Clin Sci 99 2000 555 560
-
(2000)
Clin Sci
, vol.99
, pp. 555-560
-
-
White, R.P.1
Vallance, P.2
Markus, H.S.3
-
22
-
-
84856379721
-
Central and peripheral blood flow during exercise with a continuous-flow left ventricular assist device: Constant versus increasing pump speed: A pilot study
-
P. Brassard, A.S. Jensen, and N. Nordsborg Central and peripheral blood flow during exercise with a continuous-flow left ventricular assist device: constant versus increasing pump speed: a pilot study Circ Heart Fail 4 2011 554 560
-
(2011)
Circ Heart Fail
, vol.4
, pp. 554-560
-
-
Brassard, P.1
Jensen, A.S.2
Nordsborg, N.3
-
23
-
-
84868285050
-
Cerebral blood flow autoregulation is preserved after continuous-flow left ventricular assist device implantation
-
M. Ono, B. Joshi, and K. Brady Cerebral blood flow autoregulation is preserved after continuous-flow left ventricular assist device implantation J Cardiothorac Vasc Anesth 26 2012 1022 1028
-
(2012)
J Cardiothorac Vasc Anesth
, vol.26
, pp. 1022-1028
-
-
Ono, M.1
Joshi, B.2
Brady, K.3
-
24
-
-
79951802304
-
The effect of ventricular assist devices on cerebral autoregulation: A preliminary study
-
J. Bellapart, G.S. Chan, and Y.C. Tzeng The effect of ventricular assist devices on cerebral autoregulation: a preliminary study BMC Anesthesiol 11 2011 4
-
(2011)
BMC Anesthesiol
, vol.11
, pp. 4
-
-
Bellapart, J.1
Chan, G.S.2
Tzeng, Y.C.3
-
25
-
-
0942276818
-
Respiratory measurements of cardiac output: From elegant idea to useful test
-
Lazlo G. Respiratory measurements of cardiac output: from elegant idea to useful test. J Appl Physiol (1985) 2004;96:428-37
-
(1985)
J Appl Physiol
, vol.96
, pp. 428-437
-
-
Lazlo, G.1
-
26
-
-
0023181880
-
Cardiac output by rebreathing in patients with cardiopulmonary diseases
-
Kallay MC, Hyde RW, Smith RJ, et al. Cardiac output by rebreathing in patients with cardiopulmonary diseases. J Appl Physiol (1985) 1987;63:201-10
-
(1985)
J Appl Physiol
, vol.63
, pp. 201-210
-
-
Kallay, M.C.1
Hyde, R.W.2
Smith, R.J.3
-
27
-
-
58649094210
-
Dynamic cerebral autoregulation during repeated squat-stand maneuvers
-
Claassen J, Levine BD, Zhang R. Dynamic cerebral autoregulation during repeated squat-stand maneuvers. J Appl Physiol (1985) 2009;106:153-60
-
(1985)
J Appl Physiol
, vol.106
, pp. 153-160
-
-
Claassen, J.1
Levine, B.D.2
Zhang, R.3
-
28
-
-
0022449467
-
Transcranial Doppler measurement of middle cerebral artery blood flow velocity: A validation study
-
C.C. Bishop, S. Powell, and D. Rutt Transcranial Doppler measurement of middle cerebral artery blood flow velocity: a validation study Stroke 17 1986 913 915
-
(1986)
Stroke
, vol.17
, pp. 913-915
-
-
Bishop, C.C.1
Powell, S.2
Rutt, D.3
-
29
-
-
74849115522
-
Dynamic cerebral autoregulation in The old using a repeated sit-stand maneuver
-
A.H. van Beek, M.G. Olde Rikkert, and J.W. Pasman Dynamic cerebral autoregulation in The old using a repeated sit-stand maneuver Ultrasound Med Biol 36 2010 192 201
-
(2010)
Ultrasound Med Biol
, vol.36
, pp. 192-201
-
-
Van Beek, A.H.1
Olde Rikkert, M.G.2
Pasman, J.W.3
-
30
-
-
84872316196
-
Cardiac baroreflex function and dynamic cerebral autoregulation in elderly masters athletes
-
Aengevaeren VL, Claassen AHR, Levine BD, et al. Cardiac baroreflex function and dynamic cerebral autoregulation in elderly masters athletes. J Appl Physiol (1985) 2013;195:195-202
-
(1985)
J Appl Physiol
, vol.195
, pp. 195-202
-
-
Aengevaeren, V.L.1
Claassen, A.H.R.2
Levine, B.D.3
-
31
-
-
0036238074
-
Continuous monitoring of cerebrovascular autoregulation: A validation study
-
E.W. Lang, H.M. Mehdorn, and N.W.C. Dorsch Continuous monitoring of cerebrovascular autoregulation: a validation study J Neurosurg Psychiatry 72 2002 583 586
-
(2002)
J Neurosurg Psychiatry
, vol.72
, pp. 583-586
-
-
Lang, E.W.1
Mehdorn, H.M.2
Dorsch, N.W.C.3
-
32
-
-
0029742428
-
Monitoring of cerebral autoregulation in head-injured patients
-
M. Czosnyka, P. Smielewski, and P. Kirkpatrick Monitoring of cerebral autoregulation in head-injured patients Stroke 27 1996 1829 1834
-
(1996)
Stroke
, vol.27
, pp. 1829-1834
-
-
Czosnyka, M.1
Smielewski, P.2
Kirkpatrick, P.3
-
33
-
-
33750854607
-
Transfer function analysis of dynamic cerebral autoregulation in humans
-
R. Zhang, J.H. Zuckerman, and C.A. Giller Transfer function analysis of dynamic cerebral autoregulation in humans Am J Physiol Heart Circ Physiol 274 1998 H233 H241
-
(1998)
Am J Physiol Heart Circ Physiol
, vol.274
, pp. H233-H241
-
-
Zhang, R.1
Zuckerman, J.H.2
Giller, C.A.3
-
35
-
-
1642547216
-
Description of The myogenic hypothesis
-
B. Folklow Description of The myogenic hypothesis Circ Res 15 1964 279 287
-
(1964)
Circ Res
, vol.15
, pp. 279-287
-
-
Folklow, B.1
-
36
-
-
0018830079
-
Effects of sympathetic nerves on cerebral vessels during acute, moderate increases in arterial pressure in dogs and cats
-
D.W. Busija, D.D. Heistad, and M.L. Marcus Effects of sympathetic nerves on cerebral vessels during acute, moderate increases in arterial pressure in dogs and cats Circ Res 46 1980 696 702
-
(1980)
Circ Res
, vol.46
, pp. 696-702
-
-
Busija, D.W.1
Heistad, D.D.2
Marcus, M.L.3
-
37
-
-
0018719994
-
Effect of sympathetic stimulation on permeability of The blood-brain barrier to albumin during acute hypertension in cats
-
D.D. Heistad, and M.L. Marcus Effect of sympathetic stimulation on permeability of The blood-brain barrier to albumin during acute hypertension in cats Circ Res 45 1979 331 338
-
(1979)
Circ Res
, vol.45
, pp. 331-338
-
-
Heistad, D.D.1
Marcus, M.L.2
-
38
-
-
84867572755
-
Arterial wall histology in chronic pulsatile-flow and continuous-flow device circulatory support
-
E.V. Potapov, N. Dranishnikov, and L. Morawietz Arterial wall histology in chronic pulsatile-flow and continuous-flow device circulatory support J Heart Lung Transplant 31 2012 1171 1176
-
(2012)
J Heart Lung Transplant
, vol.31
, pp. 1171-1176
-
-
Potapov, E.V.1
Dranishnikov, N.2
Morawietz, L.3
-
39
-
-
0015877469
-
A study of regional autoregulation in The cerebra circulation to increased perfusion pressure in normocapnia and hypercapnia
-
L. Symon, K. Held, and N.W.C. Dorsch A study of regional autoregulation in The cerebra circulation to increased perfusion pressure in normocapnia and hypercapnia Stroke 4 1973 139 147
-
(1973)
Stroke
, vol.4
, pp. 139-147
-
-
Symon, L.1
Held, K.2
Dorsch, N.W.C.3
-
40
-
-
0036788476
-
Autonomic neural control of dynamic cerebral autoregulation in humans
-
R. Zhang, J.H. Zuckerman, and C.A. Giller Autonomic neural control of dynamic cerebral autoregulation in humans Circulation 106 2002 1814 1820
-
(2002)
Circulation
, vol.106
, pp. 1814-1820
-
-
Zhang, R.1
Zuckerman, J.H.2
Giller, C.A.3
-
41
-
-
84934177971
-
Power spectral analysis of heart rate and arterial pressure variabilities as a marker of sympatho-vagal interaction in man and conscious dog
-
M. Pagani, F. Lombardi, and S. Guzzetti Power spectral analysis of heart rate and arterial pressure variabilities as a marker of sympatho-vagal interaction in man and conscious dog Circ Res 59 1986 178 193
-
(1986)
Circ Res
, vol.59
, pp. 178-193
-
-
Pagani, M.1
Lombardi, F.2
Guzzetti, S.3
|