Volumn 40, Issue , 2015, Pages 147-159

Real-time computer-generated integral imaging and 3D image calibration for augmented reality surgical navigation

Author keywords

3D image calibration; Augmented reality; Integral imaging; Stereo tracking; Surgical navigation

Indexed keywords

AUGMENTED REALITY; CALIBRATION; COMPUTER GRAPHICS EQUIPMENT; GEOMETRY; GRAPHICS PROCESSING UNIT; IMAGE REGISTRATION; IMAGE RESOLUTION; MEDICAL IMAGING; NAVIGATION; OPTICAL VARIABLES MEASUREMENT; PIPELINE PROCESSING SYSTEMS; PROGRAM PROCESSORS; RENDERING (COMPUTER GRAPHICS); STEREO IMAGE PROCESSING; SURGERY; THREE DIMENSIONAL COMPUTER GRAPHICS;

EID: 84922990022     PISSN: 08956111     EISSN: 18790771     Source Type: Journal    
DOI: 10.1016/j.compmedimag.2014.11.003     Document Type: Article
Times cited : (94)

References (29)
  • 1
    • 80051872997 scopus 로고    scopus 로고
    • Augmented reality in laparoscopic surgical oncology
    • Nicolau S., Soler L., Mutter D., Marescaux J. Augmented reality in laparoscopic surgical oncology. Surg Oncol 2011, 20(3):189-201. 10.1016/j.suronc.2011.07.002.
    • (2011) Surg Oncol , vol.20 , Issue.3 , pp. 189-201
    • Nicolau, S.1    Soler, L.2    Mutter, D.3    Marescaux, J.4
  • 2
    • 77955509384 scopus 로고    scopus 로고
    • Live augmented reality: a new visualization method for laparoscopic surgery using continuous volumetric computed tomography
    • Shekhar R., Dandekar O., Bhat V., Philip M., Lei P., Godinez C., et al. Live augmented reality: a new visualization method for laparoscopic surgery using continuous volumetric computed tomography. Surg Endosc 2010, 24(8):1976-1985. 10.1007/s00464-010-0890-8.
    • (2010) Surg Endosc , vol.24 , Issue.8 , pp. 1976-1985
    • Shekhar, R.1    Dandekar, O.2    Bhat, V.3    Philip, M.4    Lei, P.5    Godinez, C.6
  • 3
    • 63149171096 scopus 로고    scopus 로고
    • Augmented reality during robot-assisted laparoscopic partial nephrectomy: Toward real-time 3D-CT to stereoscopic video registration
    • Su L.-M., Vagvolgyi B.P., Agarwal R., Reiley C.E., Taylor R.H., Hager G.D. Augmented reality during robot-assisted laparoscopic partial nephrectomy: Toward real-time 3D-CT to stereoscopic video registration. Urology 2009, 73(4):896-900. 10.1016/j.urology.2008.11.040.
    • (2009) Urology , vol.73 , Issue.4 , pp. 896-900
    • Su, L.-M.1    Vagvolgyi, B.P.2    Agarwal, R.3    Reiley, C.E.4    Taylor, R.H.5    Hager, G.D.6
  • 4
    • 70449378573 scopus 로고    scopus 로고
    • A 3-d mixed-reality system for stereoscopic visualization of medical dataset
    • Ferrari V., Megali G., Troia E., Pietrabissa A., Mosca F. A 3-d mixed-reality system for stereoscopic visualization of medical dataset. IEEE Trans Biomed Eng 2009, 56(11):2627-2633. 10.1109/TBME.2009.2028013.
    • (2009) IEEE Trans Biomed Eng , vol.56 , Issue.11 , pp. 2627-2633
    • Ferrari, V.1    Megali, G.2    Troia, E.3    Pietrabissa, A.4    Mosca, F.5
  • 5
    • 27744432118 scopus 로고    scopus 로고
    • A fully automated calibration method for an optical see-through head-mounted operating microscope with variable zoom and focus
    • Figl M., Ede C., Hummel J., Wanschitz F., Ewers R., Bergmann H., et al. A fully automated calibration method for an optical see-through head-mounted operating microscope with variable zoom and focus. IEEE Trans Med Imaging 2005, 24(11):1492-1499. 10.1109/TMI.2005.856746.
    • (2005) IEEE Trans Med Imaging , vol.24 , Issue.11 , pp. 1492-1499
    • Figl, M.1    Ede, C.2    Hummel, J.3    Wanschitz, F.4    Ewers, R.5    Bergmann, H.6
  • 6
    • 67649450461 scopus 로고    scopus 로고
    • Augmented reality: a new tool to improve surgical accuracy during laparoscopic partial nephrectomy? preliminary in vitro and in vivo results
    • Teber D., Guven S., Simpfendrfer T., Baumhauer M., Gven E.O., Yencilek F., et al. Augmented reality: a new tool to improve surgical accuracy during laparoscopic partial nephrectomy? preliminary in vitro and in vivo results. Eur Urol 2009, 56(2):332-338. 10.1016/j.eururo.2009.05.017.
    • (2009) Eur Urol , vol.56 , Issue.2 , pp. 332-338
    • Teber, D.1    Guven, S.2    Simpfendrfer, T.3    Baumhauer, M.4    Gven, E.O.5    Yencilek, F.6
  • 7
    • 50249182370 scopus 로고    scopus 로고
    • Non-metal slice image overlay display system used inside the open type MRI
    • Springer, Berlin/Heidelberg, T. Dohi, I. Sakuma, H. Liao (Eds.) Medical imaging and augmented reality
    • Masamune K., Sato I., Liao H., Dohi T. Non-metal slice image overlay display system used inside the open type MRI. Lecture notes in computer science 2008, vol. 5128:385-392. Springer, Berlin/Heidelberg. 10.1007/978-3-540-79982-5_42. T. Dohi, I. Sakuma, H. Liao (Eds.).
    • (2008) Lecture notes in computer science , vol.5128 , pp. 385-392
    • Masamune, K.1    Sato, I.2    Liao, H.3    Dohi, T.4
  • 9
    • 84888288065 scopus 로고    scopus 로고
    • Projection-based visual guidance for robot-aided RF needle insertion
    • Wen R., Chui C.-K., Ong S.-H., Lim K.-B., Chang S.-Y. Projection-based visual guidance for robot-aided RF needle insertion. Int J Comput Assist Radiol Surg 2013, 8(6):1015-1025. 10.1007/s11548-013-0897-4.
    • (2013) Int J Comput Assist Radiol Surg , vol.8 , Issue.6 , pp. 1015-1025
    • Wen, R.1    Chui, C.-K.2    Ong, S.-H.3    Lim, K.-B.4    Chang, S.-Y.5
  • 10
    • 84982249606 scopus 로고    scopus 로고
    • Real time planning, guidance and validation of surgical acts using 3D segmentations, augmented reality projections and surgical tools video tracking
    • Osorio A., Galan J.-A., Nauroy J., Donars P. Real time planning, guidance and validation of surgical acts using 3D segmentations, augmented reality projections and surgical tools video tracking. Proc SPIE 2010, 7625. 10.1117/12.844039.
    • (2010) Proc SPIE , vol.7625
    • Osorio, A.1    Galan, J.-A.2    Nauroy, J.3    Donars, P.4
  • 11
    • 39049093120 scopus 로고    scopus 로고
    • Projector-based augmented reality for intuitive intraoperative guidance in image-guided 3D interstitial brachytherapy
    • Krempien R., Hoppe H., Kahrs L., Daeuber S., Schorr O., Eggers G., et al. Projector-based augmented reality for intuitive intraoperative guidance in image-guided 3D interstitial brachytherapy. Int J Radiat Oncol Biol Phys 2008, 70(3):944-952. 10.1016/j.ijrobp.2007.10.048.
    • (2008) Int J Radiat Oncol Biol Phys , vol.70 , Issue.3 , pp. 944-952
    • Krempien, R.1    Hoppe, H.2    Kahrs, L.3    Daeuber, S.4    Schorr, O.5    Eggers, G.6
  • 12
    • 24344437755 scopus 로고    scopus 로고
    • Autostereoscopic 3D displays
    • Dodgson N.A. Autostereoscopic 3D displays. Computer 2005, 8:31-36.
    • (2005) Computer , vol.8 , pp. 31-36
    • Dodgson, N.A.1
  • 13
    • 67651027634 scopus 로고    scopus 로고
    • Visual discomfort and visual fatigue of stereoscopic displays: a review
    • Lambooij M., Fortuin M., Heynderickx I., IJsselsteijn W. Visual discomfort and visual fatigue of stereoscopic displays: a review. J Imaging Sci 2009, 53(3). 10.2352/J.ImagingSci.Technol.2009.53.3.030201.
    • (2009) J Imaging Sci , vol.53 , Issue.3
    • Lambooij, M.1    Fortuin, M.2    Heynderickx, I.3    IJselsteijn, W.4
  • 14
    • 67349200934 scopus 로고    scopus 로고
    • Progress in 3-D multiperspective display by integral imaging
    • Martinez-Cuenca R., Saavedra G., Martinez-Corral M., Javidi B. Progress in 3-D multiperspective display by integral imaging. Proc IEEE 2009, 97(6):1067-1077. 10.1109/JPROC.2009.2016816.
    • (2009) Proc IEEE , vol.97 , Issue.6 , pp. 1067-1077
    • Martinez-Cuenca, R.1    Saavedra, G.2    Martinez-Corral, M.3    Javidi, B.4
  • 16
    • 0000068237 scopus 로고
    • Epreuves reversibles donnant la sensation du relief
    • Lippmann G. Epreuves reversibles donnant la sensation du relief. J Phys Theor Appl 1908, 7(1):821-825.
    • (1908) J Phys Theor Appl , vol.7 , Issue.1 , pp. 821-825
    • Lippmann, G.1
  • 17
    • 73649120630 scopus 로고    scopus 로고
    • Recent progress in three-dimensional information processing based on integral imaging
    • Park J.-H., Hong K., Lee B. Recent progress in three-dimensional information processing based on integral imaging. Appl Opt 2009, 48(34):H77-H94. 10.1364/AO.48.000H77.
    • (2009) Appl Opt , vol.48 , Issue.34 , pp. H77-H94
    • Park, J.-H.1    Hong, K.2    Lee, B.3
  • 18
    • 33644901600 scopus 로고    scopus 로고
    • Three-dimensional image sensing, visualization, and processing using integral imaging
    • Stern A., Javidi B. Three-dimensional image sensing, visualization, and processing using integral imaging. Proc IEEE 2006, 94(3):591-607. 10.1109/JPROC.2006.870696.
    • (2006) Proc IEEE , vol.94 , Issue.3 , pp. 591-607
    • Stern, A.1    Javidi, B.2
  • 19
    • 0001502339 scopus 로고    scopus 로고
    • Real-time pickup method for a three-dimensional image based on integral photography
    • Okano F., Hoshino H., Arai J., Yuyama I. Real-time pickup method for a three-dimensional image based on integral photography. Appl Opt 1997, 36(7):1598-1603. 10.1364/AO.36.001598.
    • (1997) Appl Opt , vol.36 , Issue.7 , pp. 1598-1603
    • Okano, F.1    Hoshino, H.2    Arai, J.3    Yuyama, I.4
  • 20
    • 0000753580 scopus 로고    scopus 로고
    • Integral three-dimensional imaging with digital reconstruction
    • Arimoto H., Javidi B. Integral three-dimensional imaging with digital reconstruction. Opt Lett 2001, 26(3):157-159. 10.1364/OL.26.000157.
    • (2001) Opt Lett , vol.26 , Issue.3 , pp. 157-159
    • Arimoto, H.1    Javidi, B.2
  • 21
    • 2942744718 scopus 로고    scopus 로고
    • Three-dimensional volumetric object reconstruction using computational integral imaging
    • Hong S.-H., Jang J.-S., Javidi B. Three-dimensional volumetric object reconstruction using computational integral imaging. Opt Exp 2004, 12(3):483-491. 10.1364/OPEX.12.000483.
    • (2004) Opt Exp , vol.12 , Issue.3 , pp. 483-491
    • Hong, S.-H.1    Jang, J.-S.2    Javidi, B.3
  • 22
    • 15544381010 scopus 로고    scopus 로고
    • Three-dimensional display with a long viewing distance by use of integral photography
    • Liao H., Iwahara M., Katayama Y., Hata N., Dohi T. Three-dimensional display with a long viewing distance by use of integral photography. Opt Lett 2005, 30(6):613-615. 10.1364/OL.30.000613.
    • (2005) Opt Lett , vol.30 , Issue.6 , pp. 613-615
    • Liao, H.1    Iwahara, M.2    Katayama, Y.3    Hata, N.4    Dohi, T.5
  • 23
    • 34447650252 scopus 로고    scopus 로고
    • Depth-enhanced integral imaging display system with electrically variable image planes using polymer-dispersed liquid-crystal layers
    • Kim Y., Choi H., Kim J., Cho S.-W., Kim Y., Park G., et al. Depth-enhanced integral imaging display system with electrically variable image planes using polymer-dispersed liquid-crystal layers. Appl Opt 2007, 46(18):3766-3773. 10.1364/AO.46.003766.
    • (2007) Appl Opt , vol.46 , Issue.18 , pp. 3766-3773
    • Kim, Y.1    Choi, H.2    Kim, J.3    Cho, S.-W.4    Kim, Y.5    Park, G.6
  • 24
  • 25
    • 77952554970 scopus 로고    scopus 로고
    • 3-d augmented reality for mri-guided surgery using integral videography autostereoscopic image overlay
    • Liao H., Inomata T., Sakuma I., Dohi T. 3-d augmented reality for mri-guided surgery using integral videography autostereoscopic image overlay. IEEE Trans Biomed Eng 2010, 57(6):1476-1486. 10.1109/TBME.2010.2040278.
    • (2010) IEEE Trans Biomed Eng , vol.57 , Issue.6 , pp. 1476-1486
    • Liao, H.1    Inomata, T.2    Sakuma, I.3    Dohi, T.4
  • 26
    • 72049110240 scopus 로고    scopus 로고
    • Precision-guided surgical navigation system using laser guidance and 3d autostereoscopic image overlay
    • Liao H., Ishihara H., Tran H.H., Masamune K., Sakuma I., Dohi T. Precision-guided surgical navigation system using laser guidance and 3d autostereoscopic image overlay. Comput Med Imaging Gr 2010, 34(1):46-54. 10.1016/j.compmedimag.2009.07.003.
    • (2010) Comput Med Imaging Gr , vol.34 , Issue.1 , pp. 46-54
    • Liao, H.1    Ishihara, H.2    Tran, H.H.3    Masamune, K.4    Sakuma, I.5    Dohi, T.6
  • 27
    • 84897129185 scopus 로고    scopus 로고
    • Augmented reality navigation with automatic marker-free image registration using 3D image overlay for dental surgery
    • Wang J., Suenaga H., Hoshi K., Yang L., Kobayashi E., Sakuma I., et al. Augmented reality navigation with automatic marker-free image registration using 3D image overlay for dental surgery. IEEE Trans Biomed Eng 2014, 61(4):1295-1304. 10.1109/TBME.2014.2301191.
    • (2014) IEEE Trans Biomed Eng , vol.61 , Issue.4 , pp. 1295-1304
    • Wang, J.1    Suenaga, H.2    Hoshi, K.3    Yang, L.4    Kobayashi, E.5    Sakuma, I.6
  • 29
    • 0035437717 scopus 로고    scopus 로고
    • The distribution of target registration error in rigid-body point-based registration
    • Fitzpatrick J., West J. The distribution of target registration error in rigid-body point-based registration. IEEE Trans Med Imaging 2001, 20(9):917-927. 10.1109/42.952729.
    • (2001) IEEE Trans Med Imaging , vol.20 , Issue.9 , pp. 917-927
    • Fitzpatrick, J.1    West, J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.