메뉴 건너뛰기




Volumn 26, Issue 3, 2015, Pages 287-292

Impact of abutment microstructure and insertion depth on crestal bone changes at nonsubmerged titanium implants with platform switch

Author keywords

Animal study; Histomorphometry; Insertion depth; Titanium implant

Indexed keywords

TITANIUM; TOOTH IMPLANT;

EID: 84922737129     PISSN: 09057161     EISSN: 16000501     Source Type: Journal    
DOI: 10.1111/clr.12478     Document Type: Article
Times cited : (22)

References (18)
  • 1
    • 68549099723 scopus 로고    scopus 로고
    • Effects of different implant surfaces and designs on marginal bone-level alterations: a review
    • Abrahamsson, I. & Berglundh, T. (2009) Effects of different implant surfaces and designs on marginal bone-level alterations: a review. Clinical Oral Implants Research 20(Suppl 4): 207-215.
    • (2009) Clinical Oral Implants Research , vol.20 , pp. 207-215
    • Abrahamsson, I.1    Berglundh, T.2
  • 3
    • 78249253317 scopus 로고    scopus 로고
    • Platform switching for marginal bone preservation around dental implants: a systematic review and meta-analysis
    • Atieh, M.A., Ibrahim, H.M. & Atieh, A.H. (2010) Platform switching for marginal bone preservation around dental implants: a systematic review and meta-analysis. Journal of Periodontology 81: 1350-1366.
    • (2010) Journal of Periodontology , vol.81 , pp. 1350-1366
    • Atieh, M.A.1    Ibrahim, H.M.2    Atieh, A.H.3
  • 4
    • 77951605276 scopus 로고    scopus 로고
    • Influence of interimplant distances and placement depth on peri-implant bone remodeling of adjacent and immediately loaded Morse cone connection implants: a histomorphometric study in dogs
    • Barros, R.R., Novaes, A.B. Jr, Muglia, V.A., Iezzi, G. & Piattelli, A. (2010) Influence of interimplant distances and placement depth on peri-implant bone remodeling of adjacent and immediately loaded Morse cone connection implants: a histomorphometric study in dogs. Clinical Oral Implants Research 21: 371-378.
    • (2010) Clinical Oral Implants Research , vol.21 , pp. 371-378
    • Barros, R.R.1    Novaes Jr, A.B.2    Muglia, V.A.3    Iezzi, G.4    Piattelli, A.5
  • 5
    • 36249002863 scopus 로고    scopus 로고
    • Influence of platform switching on crestal bone changes at non-submerged titanium implants: a histomorphometrical study in dogs
    • Becker, J., Ferrari, D., Herten, M., Kirsch, A., Schaer, A. & Schwarz, F. (2007) Influence of platform switching on crestal bone changes at non-submerged titanium implants: a histomorphometrical study in dogs. Journal of Clinical Periodontology 34: 1089-1096.
    • (2007) Journal of Clinical Periodontology , vol.34 , pp. 1089-1096
    • Becker, J.1    Ferrari, D.2    Herten, M.3    Kirsch, A.4    Schaer, A.5    Schwarz, F.6
  • 6
    • 67649544878 scopus 로고    scopus 로고
    • Stability of crestal bone level at platform-switched non-submerged titanium implants: a histomorphometrical study in dogs
    • Becker, J., Ferrari, D., Mihatovic, I., Sahm, N., Schaer, A. & Schwarz, F. (2009) Stability of crestal bone level at platform-switched non-submerged titanium implants: a histomorphometrical study in dogs. Journal of Clinical Periodontology 36: 532-539.
    • (2009) Journal of Clinical Periodontology , vol.36 , pp. 532-539
    • Becker, J.1    Ferrari, D.2    Mihatovic, I.3    Sahm, N.4    Schaer, A.5    Schwarz, F.6
  • 8
    • 84865973435 scopus 로고    scopus 로고
    • Influence of placement depth on bone remodeling around tapered internal connection implant: a clinical and radiographic study in dogs
    • Huang, B., Meng, H., Piao, M., Xu, L., Zhang, L. & Zhu, W. (2012) Influence of placement depth on bone remodeling around tapered internal connection implant: a clinical and radiographic study in dogs. Journal of Periodontology 83: 1164-1171.
    • (2012) Journal of Periodontology , vol.83 , pp. 1164-1171
    • Huang, B.1    Meng, H.2    Piao, M.3    Xu, L.4    Zhang, L.5    Zhu, W.6
  • 9
    • 84874785324 scopus 로고    scopus 로고
    • The impact of dis-/reconnection of laser microgrooved and machined implant abutments on soft- and hard-tissue healing
    • Iglhaut, G., Becker, K., Golubovic, V., Schliephake, H. & Mihatovic, I. (2013) The impact of dis-/reconnection of laser microgrooved and machined implant abutments on soft- and hard-tissue healing. Clinical Oral Implants Reserach 24: 391-397.
    • (2013) Clinical Oral Implants Reserach , vol.24 , pp. 391-397
    • Iglhaut, G.1    Becker, K.2    Golubovic, V.3    Schliephake, H.4    Mihatovic, I.5
  • 10
    • 68549097985 scopus 로고    scopus 로고
    • Implant surfaces and design (Working Group 4)
    • Lang, N.P. & Jepsen, S. (2009) Implant surfaces and design (Working Group 4). Clinical Oral Implants Reserach 20(Suppl 4): 228-231.
    • (2009) Clinical Oral Implants Reserach , vol.20 , pp. 228-231
    • Lang, N.P.1    Jepsen, S.2
  • 11
    • 73349106551 scopus 로고    scopus 로고
    • The influence of soft tissue thickness on crestal bone changes around implants: a 1-year prospective controlled clinical trial
    • Linkevicius, T., Apse, P., Grybauskas, S. & Puisys, A. (2009) The influence of soft tissue thickness on crestal bone changes around implants: a 1-year prospective controlled clinical trial. International Journal of Oral and Maxillofacial Implants 24: 712-719.
    • (2009) International Journal of Oral and Maxillofacial Implants , vol.24 , pp. 712-719
    • Linkevicius, T.1    Apse, P.2    Grybauskas, S.3    Puisys, A.4
  • 12
    • 42149170576 scopus 로고    scopus 로고
    • Biologic width changes around loaded implants inserted in different levels in relation to crestal bone: histometric evaluation in canine mandible
    • Pontes, A.E., Ribeiro, F.S., Iezzi, G., Piattelli, A., Cirelli, J.A. & Marcantonio, E. Jr. (2008) Biologic width changes around loaded implants inserted in different levels in relation to crestal bone: histometric evaluation in canine mandible. Clinical Oral Implants Research 19: 483-490.
    • (2008) Clinical Oral Implants Research , vol.19 , pp. 483-490
    • Pontes, A.E.1    Ribeiro, F.S.2    Iezzi, G.3    Piattelli, A.4    Cirelli, J.A.5    Marcantonio Jr, E.6
  • 13
    • 84931572468 scopus 로고    scopus 로고
    • Impact of implant-abutment connection, positioning of the machined collar/microgap, and platform switching on crestal bone level changes. Camlog Foundation Consensus Report
    • [Epub ahead of print]
    • Schwarz, F., Alcoforado, G., Nelson, K., Schaer, A., Taylor, T., Beuer, F. & Strietzel, F.P. (2013b) Impact of implant-abutment connection, positioning of the machined collar/microgap, and platform switching on crestal bone level changes. Camlog Foundation Consensus Report. Clinical Oral Implants Reserach doi: 10.1111/clr.12269. [Epub ahead of print]
    • (2013) Clinical Oral Implants Reserach
    • Schwarz, F.1    Alcoforado, G.2    Nelson, K.3    Schaer, A.4    Taylor, T.5    Beuer, F.6    Strietzel, F.P.7
  • 14
    • 84897607023 scopus 로고    scopus 로고
    • Impact of implant-abutment connection and positioning of the machined collar/microgap on crestal bone level changes: a systematic review
    • Schwarz, F., Hegewald, A. & Becker, J. (2013a) Impact of implant-abutment connection and positioning of the machined collar/microgap on crestal bone level changes: a systematic review. Clinical Oral Implants Research 25: 417-425.
    • (2013) Clinical Oral Implants Research , vol.25 , pp. 417-425
    • Schwarz, F.1    Hegewald, A.2    Becker, J.3
  • 15
    • 80052764706 scopus 로고    scopus 로고
    • Surgical therapy of advanced ligature-induced peri-implantitis defects: cone-beam computed tomographic and histological analysis
    • Schwarz, F., Sahm, N., Mihatovic, I., Golubovic, V. & Becker, J. (2011) Surgical therapy of advanced ligature-induced peri-implantitis defects: cone-beam computed tomographic and histological analysis. Journal of Clinical Periodontology 38: 939-949.
    • (2011) Journal of Clinical Periodontology , vol.38 , pp. 939-949
    • Schwarz, F.1    Sahm, N.2    Mihatovic, I.3    Golubovic, V.4    Becker, J.5
  • 18
    • 77955866805 scopus 로고    scopus 로고
    • Influence of microgap location and configuration on peri-implant bone morphology in nonsubmerged implants: an experimental study in dogs
    • Weng, D., Nagata, M.J., Bell, M., de Melo, L.G. & Bosco, A.F. (2010) Influence of microgap location and configuration on peri-implant bone morphology in nonsubmerged implants: an experimental study in dogs. International Journal of Oral and Maxillofacial Implants 25: 540-547.
    • (2010) International Journal of Oral and Maxillofacial Implants , vol.25 , pp. 540-547
    • Weng, D.1    Nagata, M.J.2    Bell, M.3    de Melo, L.G.4    Bosco, A.F.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.