-
1
-
-
77649235080
-
Structural and microfluidic analysis of hollow side-open polymeric microneedles for transdermal drug delivery applications
-
D.W. Bodhale, A. Nisar, and N. Afzulpurkar Structural and microfluidic analysis of hollow side-open polymeric microneedles for transdermal drug delivery applications Microfluid Nanofluid 8 2010 373 392
-
(2010)
Microfluid Nanofluid
, vol.8
, pp. 373-392
-
-
Bodhale, D.W.1
Nisar, A.2
Afzulpurkar, N.3
-
2
-
-
2942716734
-
Insertion of microneedles into skin: Measurement and prediction of insertion force and needle fracture force
-
S.P. Davis, B.J. Landis, Z.H. Adams, M.G. Allen, and M.R. Prausnitz Insertion of microneedles into skin: measurement and prediction of insertion force and needle fracture force J. Biomech. 37 2004 August 1155 1163 http://linkinghub.elsevier.com/retrieve/pii/S0021929003004731
-
(2004)
J. Biomech.
, vol.37
, pp. 1155-1163
-
-
Davis, S.P.1
Landis, B.J.2
Adams, Z.H.3
Allen, M.G.4
Prausnitz, M.R.5
-
3
-
-
78651261187
-
Design, optimization and characteisation of polymeric microneedle arrays prepared by a novel laser-based micromoulding technique
-
R.F. Donnelly, R. Maijithia, T.R.R. Singh, D.I.J. Morrow, M.J. Garland, Y.K. Demir, K. Migalska, E. Ryan, D. Gillen, C.J. Scott, and A.D. Woolfson Design, optimization and characteisation of polymeric microneedle arrays prepared by a novel laser-based micromoulding technique Pharm. Res. 28 2011 41 57
-
(2011)
Pharm. Res.
, vol.28
, pp. 41-57
-
-
Donnelly, R.F.1
Maijithia, R.2
Singh, T.R.R.3
Morrow, D.I.J.4
Garland, M.J.5
Demir, Y.K.6
Migalska, K.7
Ryan, E.8
Gillen, D.9
Scott, C.J.10
Woolfson, A.D.11
-
4
-
-
0031852494
-
Microfabricated microneedles: A new approach to transdermal drug delivery
-
S. Henry, D.V. McAllister, M.G. Allen, and M.R. Prausnitz Microfabricated microneedles: a new approach to transdermal drug delivery J. Pharm. Sci. 87 1998 922 925
-
(1998)
J. Pharm. Sci.
, vol.87
, pp. 922-925
-
-
Henry, S.1
McAllister, D.V.2
Allen, M.G.3
Prausnitz, M.R.4
-
5
-
-
33845773955
-
High aspect ratio tapered hollow metallic microneedle arrays with microfluidic interconnector
-
K. Kim, and J.-B. Lee High aspect ratio tapered hollow metallic microneedle arrays with microfluidic interconnector Microsyst. Technol. 13 2006 July 231 235 10.1007/s00542-006-0221-0
-
(2006)
Microsyst. Technol.
, vol.13
, pp. 231-235
-
-
Kim, K.1
Lee, J.-B.2
-
6
-
-
67649519373
-
Measurement and prediction of insertion force for the mosquito fascicle penetrating into human skin
-
X. Kong, and C. Wu Measurement and prediction of insertion force for the mosquito fascicle penetrating into human skin J. Bionic Eng. 6 2009 June 143 152 http://linkinghub.elsevier.com/retrieve/pii/S1672652908601110
-
(2009)
J. Bionic Eng.
, vol.6
, pp. 143-152
-
-
Kong, X.1
Wu, C.2
-
7
-
-
84902817380
-
A proposed model membrane and test method for microneedle insertion studies
-
E. Larrañeta, J. Moore, E.M. Vicente-Pérez, P. González-Vázquez, R. Lutton, A.D. Woolfson, and R.F. Donnelly A proposed model membrane and test method for microneedle insertion studies Int. J. Pharm. 472 2014 Sep. 65 73
-
(2014)
Int. J. Pharm.
, vol.472
, pp. 65-73
-
-
Larrañeta, E.1
Moore, J.2
Vicente-Pérez, E.M.3
González-Vázquez, P.4
Lutton, R.5
Woolfson, A.D.6
Donnelly, R.F.7
-
8
-
-
84872359250
-
Optimizing hollow microneedles arrays aimed at transdermal drug delivery
-
M.S. Lhernould Optimizing hollow microneedles arrays aimed at transdermal drug delivery Microsyst. Technol. 19 2013 January 1 8 10.1007/s00542-012-1663-1
-
(2013)
Microsyst. Technol.
, vol.19
, pp. 1-8
-
-
Lhernould, M.S.1
-
9
-
-
33646709695
-
Mechanism of fluid infusion during microneedle insertion and retraction
-
W. Martanto, J.S. Moore, T. Couse, and M.R. Prausnitz Mechanism of fluid infusion during microneedle insertion and retraction J. Control. Release 112 2006 May 357 361 http://linkinghub.elsevier.com/retrieve/pii/S0168365906001076
-
(2006)
J. Control. Release
, vol.112
, pp. 357-361
-
-
Martanto, W.1
Moore, J.S.2
Couse, T.3
Prausnitz, M.R.4
-
10
-
-
33646882359
-
Polymer microneedles for controlled-release drug delivery
-
J.-H. Park, M.G. Allen, and M.R. Prausnitz Polymer microneedles for controlled-release drug delivery Pharm. Res. 23 2006 May 1008 1019 10.1007/s11095-006-0028-9
-
(2006)
Pharm. Res.
, vol.23
, pp. 1008-1019
-
-
Park, J.-H.1
Allen, M.G.2
Prausnitz, M.R.3
-
11
-
-
1542358759
-
Microneedles for transdermal drug delivery
-
M.R. Prausnitz Microneedles for transdermal drug delivery Adv. Drug Deliv. Rev. 56 2004 587
-
(2004)
Adv. Drug Deliv. Rev.
, vol.56
, pp. 587
-
-
Prausnitz, M.R.1
-
12
-
-
36949000879
-
Penetration-enhanced ultrasharp microneedles and prediction on skin interaction for efficient transdermal drug delivery
-
N. Roxhed, T.C. Gasser, P. Griss, G.A. Holzapfel, and G. Stemme Penetration-enhanced ultrasharp microneedles and prediction on skin interaction for efficient transdermal drug delivery J. Microelectromech. Syst. 16 2007 1429 1440
-
(2007)
J. Microelectromech. Syst.
, vol.16
, pp. 1429-1440
-
-
Roxhed, N.1
Gasser, T.C.2
Griss, P.3
Holzapfel, G.A.4
Stemme, G.5
-
13
-
-
39749199632
-
Painless drug delivery through microneedle-based transdermal patches featuring active infusion
-
N. Roxhed, B. Samel, L. Nordquist, P. Griss, and G. Stemme Painless drug delivery through microneedle-based transdermal patches featuring active infusion IEEE Trans. Biomed. Eng. 55 2008 1063 1071
-
(2008)
IEEE Trans. Biomed. Eng.
, vol.55
, pp. 1063-1071
-
-
Roxhed, N.1
Samel, B.2
Nordquist, L.3
Griss, P.4
Stemme, G.5
-
14
-
-
80755153550
-
Innovative design of hollow polymeric microneedles for transdermal drug delivery
-
M. Sausse Lhernould, and A. Delchambre Innovative design of hollow polymeric microneedles for transdermal drug delivery Microsyst. Technol. 17 2011 October 1675 1682 10.1007/s00542-011-1355-2
-
(2011)
Microsyst. Technol.
, vol.17
, pp. 1675-1682
-
-
Sausse Lhernould, M.1
Delchambre, A.2
-
15
-
-
84875906872
-
Microneedle array penetration tests: Understanding the bed of nails effect
-
M. Sausse Lhernould, C. Gobillon, and P. Lambert Microneedle array penetration tests: understanding the bed of nails effect OnDrugDelivery 40 2013 March 29 32
-
(2013)
OnDrugDelivery
, Issue.40
, pp. 29-32
-
-
Sausse Lhernould, M.1
Gobillon, C.2
Lambert, P.3
-
17
-
-
22444434334
-
Arrays of hollow out-of-plane microneedles for drug delivery
-
B. Stoeber, and D. Liepmann Arrays of hollow out-of-plane microneedles for drug delivery J. Microelectromech. Syst. 14 2005 472 479
-
(2005)
J. Microelectromech. Syst.
, vol.14
, pp. 472-479
-
-
Stoeber, B.1
Liepmann, D.2
-
18
-
-
33746582332
-
Transdermal microneedles for drug delivery applications
-
A.L. Teo, C. Shearwood, K.C. Ng, J. Lu, and S. Moochhala Transdermal microneedles for drug delivery applications Mater. Sci. Eng. B 132 2006 July 151 154 http://linkinghub.elsevier.com/retrieve/pii/S0921510706000912
-
(2006)
Mater. Sci. Eng. B
, vol.132
, pp. 151-154
-
-
Teo, A.L.1
Shearwood, C.2
Ng, K.C.3
Lu, J.4
Moochhala, S.5
-
19
-
-
84903559677
-
Impact-insertion applicator improves reliability of skin penetration by solid microneedle arrays
-
K. van der Maaden, E. Sekerdag, W. Jiskoot, and J. Bouwstra Impact-insertion applicator improves reliability of skin penetration by solid microneedle arrays AAPS J. 16 2014 July 681 684
-
(2014)
AAPS J.
, vol.16
, pp. 681-684
-
-
Van Der Maaden, K.1
Sekerdag, E.2
Jiskoot, W.3
Bouwstra, J.4
-
21
-
-
84862946885
-
Sharp tipped plastic hollow microneedle array by microinjection moulding
-
K. Yung, Y. Xu, C. Kang, H. Liu, K. Tam, S. Ko, F. Kwan, and T. Lee Sharp tipped plastic hollow microneedle array by microinjection moulding J. Micromech. Microeng. 22 2012 015016
-
(2012)
J. Micromech. Microeng.
, vol.22
, pp. 015016
-
-
Yung, K.1
Xu, Y.2
Kang, C.3
Liu, H.4
Tam, K.5
Ko, S.6
Kwan, F.7
Lee, T.8
|