메뉴 건너뛰기




Volumn 100, Issue 24, 2014, Pages 1903-1904

Evaluating paravalvular leak after TAVR

Author keywords

[No Author keywords available]

Indexed keywords

AORTA VALVE PROSTHESIS; AORTA VALVE REGURGITATION; CARDIOVASCULAR MAGNETIC RESONANCE; CARDIOVASCULAR PARAMETERS; COLOR ULTRASOUND FLOWMETRY; CORONARY ARTERY BLOOD FLOW; DIAGNOSTIC ACCURACY; DIAGNOSTIC ERROR; DIAGNOSTIC TEST ACCURACY STUDY; DISEASE SEVERITY; EDITORIAL; HEART OUTPUT; HUMAN; INTERMETHOD COMPARISON; MEDICAL DEVICE COMPLICATION; PARAVALVULAR LEAK; PRIORITY JOURNAL; REGURGITANT FRACTION; REGURGITANT VOLUME; REPRODUCIBILITY; SENSITIVITY AND SPECIFICITY; TRANSCATHETER AORTIC VALVE IMPLANTATION; TRANSTHORACIC ECHOCARDIOGRAPHY; AORTIC VALVE INSUFFICIENCY; FEMALE; MALE; POSTOPERATIVE COMPLICATIONS; PROCEDURES;

EID: 84922480921     PISSN: 13556037     EISSN: 1468201X     Source Type: Journal    
DOI: 10.1136/heartjnl-2014-306390     Document Type: Editorial
Times cited : (11)

References (9)
  • 1
    • 79251565276 scopus 로고    scopus 로고
    • Incidence and predictors of early and late mortality after transcatheter aortic valve implantation in 663 patients with severe aortic stenosis
    • Tamburino C, Capodanno D, Ramondo A, et al. Incidence and predictors of early and late mortality after transcatheter aortic valve implantation in 663 patients with severe aortic stenosis. Circulation 2011;123:299-308.
    • (2011) Circulation , vol.123 , pp. 299-308
    • Tamburino, C.1    Capodanno, D.2    Ramondo, A.3
  • 2
    • 79955891681 scopus 로고    scopus 로고
    • Aortic regurgitation after transcatheter aortic valve implantation: Incidence and early outcome. Results from the German transcatheter aortic valve interventions registry
    • Abdel-Wahab M, Zahn R, Horack M, et al. Aortic regurgitation after transcatheter aortic valve implantation: incidence and early outcome. Results from the German transcatheter aortic valve interventions registry. Heart 2011;97:899-906.
    • (2011) Heart , vol.97 , pp. 899-906
    • Abdel-Wahab, M.1    Zahn, R.2    Horack, M.3
  • 3
    • 84871290564 scopus 로고    scopus 로고
    • Impact of post-procedural aortic regurgitation on mortality after transcatheter aortic valve implantation
    • Hayashida K, Lefevre T, Chevalier B, et al. Impact of post-procedural aortic regurgitation on mortality after transcatheter aortic valve implantation. JACC Cardiovasc Interv 2012;5:1247-56.
    • (2012) JACC Cardiovasc Interv , vol.5 , pp. 1247-1256
    • Hayashida, K.1    Lefevre, T.2    Chevalier, B.3
  • 4
    • 84860466759 scopus 로고    scopus 로고
    • Two-year outcomes after transcatheter or surgical aortic-valve replacement
    • Kodali SK, Williams MR, Smith CR, et al. Two-year outcomes after transcatheter or surgical aortic-valve replacement. N Engl J Med 2012;366:1686-95.
    • (2012) N Engl J Med , vol.366 , pp. 1686-1695
    • Kodali, S.K.1    Williams, M.R.2    Smith, C.R.3
  • 5
    • 84867310219 scopus 로고    scopus 로고
    • Updated standardized endpoint definitions for transcatheter aortic valve implantation: The Valve Academic Research Consortium-2 consensus document
    • Kappetein AP, Head SJ, Généreux P, et al. Updated standardized endpoint definitions for transcatheter aortic valve implantation: the Valve Academic Research Consortium-2 consensus document. Eur Heart J 2012;22:2403-18.
    • (2012) Eur Heart J , vol.22 , pp. 2403-2418
    • Kappetein, A.P.1    Head, S.J.2    Généreux, P.3
  • 6
    • 84922480302 scopus 로고    scopus 로고
    • Aortic regurgitation severity after transcatheter aortic valve implantation is underestimated by echocardiography compared to magnetic resonance imaging
    • Orwat S, Diller G, Kaleschke G, et al. Aortic regurgitation severity after transcatheter aortic valve implantation is underestimated by echocardiography compared to magnetic resonance imaging. Heart 2014;100:1933-8.
    • (2014) Heart , vol.100 , pp. 1933-1938
    • Orwat, S.1    Diller, G.2    Kaleschke, G.3
  • 7
    • 84922482081 scopus 로고    scopus 로고
    • Cardiac magnetic resonance versus transthoracic echocardiography for the assessment and quantification of aortic regurgitation in patients undergoing transcatheter aortic valve implantation
    • Ribeiro H, Le Ven F, Dahou A, et al. Cardiac magnetic resonance versus transthoracic echocardiography for the assessment and quantification of aortic regurgitation in patients undergoing transcatheter aortic valve implantation. Heart 2014;100:1924-32.
    • (2014) Heart , vol.100 , pp. 1924-1932
    • Ribeiro, H.1    Le Ven, F.2    Dahou, A.3
  • 8
    • 84886425343 scopus 로고    scopus 로고
    • Anatomic versus physiologic assessment of coronary artery disease. Role of coronary flow reserve, fractional flow reserve, and positron emission tomography imaging in revascularization decision-making
    • Gould KL, Johnson NP, Bateman TM, et al. Anatomic versus physiologic assessment of coronary artery disease. Role of coronary flow reserve, fractional flow reserve, and positron emission tomography imaging in revascularization decision-making. J Am Coll Cardiol 2013;62:1639-53.
    • (2013) J Am Coll Cardiol , vol.62 , pp. 1639-1653
    • Gould, K.L.1    Johnson, N.P.2    Bateman, T.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.