Volumn 40, Issue 4, 2014, Pages 532-538

Evaluation of the Microsoft Kinect as a clinical assessment tool of body sway

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; ARTICLE; ARTIFACT; BODY EQUILIBRIUM; BODY MASS; CLINICAL ASSESSMENT TOOL; COST; DEVICE COMPARISON; DIAGNOSTIC TEST ACCURACY STUDY; DIAGNOSTIC VALUE; EVALUATION STUDY; GENERAL MEDICAL DEVICE; HUMAN; HUMAN EXPERIMENT; KINEMATICS; MALE; MEASUREMENT ACCURACY; MOTION ANALYSIS SYSTEM; MOTION CAPTURE DEVICE; ORTHOPEDIC SOFTWARE; PHYSICAL PARAMETERS; PRIORITY JOURNAL; PROPRIOCEPTIVE FEEDBACK; SENSITIVITY AND SPECIFICITY; TOTAL BODY CENTER OF MASS; BIOMECHANICS; COMPUTER PROGRAM; DEVICES; MOVEMENT (PHYSIOLOGY); PHYSIOLOGY; REPRODUCIBILITY; SIGNAL PROCESSING; STATISTICAL MODEL;

EID: 84921980441     PISSN: 09666362     EISSN: 18792219     Source Type: Journal    
DOI: 10.1016/j.gaitpost.2014.06.012     Document Type: Article
Times cited : (122)

References (30)
  • 1
    • 0035984824 scopus 로고    scopus 로고
    • The epidemiology of falls and syncope
    • Rubenstein L., Josephson K. The epidemiology of falls and syncope. Clin Geriatr Med 2002, 18:141-158.
    • (2002) Clin Geriatr Med , vol.18 , pp. 141-158
    • Rubenstein, L.1    Josephson, K.2
  • 2
    • 33750623429 scopus 로고    scopus 로고
    • Postural orientation and equilibrium: what do we need to know about neural control of balance to prevent falls?
    • Horak F.B. Postural orientation and equilibrium: what do we need to know about neural control of balance to prevent falls?. Age Ageing 2006, 35(Suppl 2):ii7-ii11.
    • (2006) Age Ageing , vol.35 , pp. ii7-ii11
    • Horak, F.B.1
  • 4
    • 0030960047 scopus 로고    scopus 로고
    • Postural perturbation: new insights for treatment of balance disorders
    • Horak F.B., Henry S.M., Shumway-Cook A. Postural perturbation: new insights for treatment of balance disorders. Phys Ther 1997, 77:517-533.
    • (1997) Phys Ther , vol.77 , pp. 517-533
    • Horak, F.B.1    Henry, S.M.2    Shumway-Cook, A.3
  • 6
    • 77956379273 scopus 로고    scopus 로고
    • The role of instrumental assessment of balance in clinical decision making
    • Nardone A., Schieppati M. The role of instrumental assessment of balance in clinical decision making. Eur J Phys Rehabil Med 2010, 46:221-237.
    • (2010) Eur J Phys Rehabil Med , vol.46 , pp. 221-237
    • Nardone, A.1    Schieppati, M.2
  • 7
    • 16644379892 scopus 로고    scopus 로고
    • The assessment of body sway and the choice of the stability parameters
    • Raymakers J., Samson M., Verhaar H. The assessment of body sway and the choice of the stability parameters. Gait Posture 2005, 21:48-58.
    • (2005) Gait Posture , vol.21 , pp. 48-58
    • Raymakers, J.1    Samson, M.2    Verhaar, H.3
  • 8
    • 0028387493 scopus 로고
    • Biomechanical relationship between center of gravity and center of pressure during standing
    • Benda B.J., Riley P.O., Krebs D.E. Biomechanical relationship between center of gravity and center of pressure during standing. IEEE Trans Rehabil Eng 1994, 2(1):3-10.
    • (1994) IEEE Trans Rehabil Eng , vol.2 , Issue.1 , pp. 3-10
    • Benda, B.J.1    Riley, P.O.2    Krebs, D.E.3
  • 9
    • 3242703251 scopus 로고    scopus 로고
    • Comparison of three methods to estimate the center of mass during balance assessment
    • Lafond D., Duarte M., Prince F. Comparison of three methods to estimate the center of mass during balance assessment. J Biomech 2004, 37:1421-1426.
    • (2004) J Biomech , vol.37 , pp. 1421-1426
    • Lafond, D.1    Duarte, M.2    Prince, F.3
  • 10
    • 84857612141 scopus 로고    scopus 로고
    • Accuracy and resolution of Kinect depth data for indoor mapping applications
    • Khoshelham K., Elberink S.O. Accuracy and resolution of Kinect depth data for indoor mapping applications. Sensors 2012, 12:1437-1454.
    • (2012) Sensors , vol.12 , pp. 1437-1454
    • Khoshelham, K.1    Elberink, S.O.2
  • 12
    • 84858074442 scopus 로고    scopus 로고
    • Evaluation of the Microsoft Kinect™ sensor for 3-D kinematic measurement in the workplace
    • Dutta T. Evaluation of the Microsoft Kinect™ sensor for 3-D kinematic measurement in the workplace. Appl Ergon 2012, 43:645-649.
    • (2012) Appl Ergon , vol.43 , pp. 645-649
    • Dutta, T.1
  • 13
  • 14
    • 84888302836 scopus 로고    scopus 로고
    • Validity and reliability of the Kinect within functional assessment activities: comparison with standard stereophotogrammetry
    • Bonnechère B., Jansen B., Salvia P., Bouzahouene H., Omelina L., Moiseev F., et al. Validity and reliability of the Kinect within functional assessment activities: comparison with standard stereophotogrammetry. Gait Posture 2014, 39(1):593-598.
    • (2014) Gait Posture , vol.39 , Issue.1 , pp. 593-598
    • Bonnechère, B.1    Jansen, B.2    Salvia, P.3    Bouzahouene, H.4    Omelina, L.5    Moiseev, F.6
  • 15
    • 84884984741 scopus 로고    scopus 로고
    • Concurrent validity of the Microsoft Kinect for assessment of spatiotemporal gait variables
    • Clark R.A., Bower K.J., Mentiplay B.F., Paterson K., Pua Y.H. Concurrent validity of the Microsoft Kinect for assessment of spatiotemporal gait variables. J Biomech 2013, 46(15):2722-2725.
    • (2013) J Biomech , vol.46 , Issue.15 , pp. 2722-2725
    • Clark, R.A.1    Bower, K.J.2    Mentiplay, B.F.3    Paterson, K.4    Pua, Y.H.5
  • 16
    • 84862259898 scopus 로고    scopus 로고
    • Development and evaluation of low cost game-based balance rehabilitation tool using the Kinect Sensor
    • Lange B., Chang C.Y., Suma E., Newman B., Rizzo A., Bolas M. Development and evaluation of low cost game-based balance rehabilitation tool using the Kinect Sensor. Conf Proc IEEE Eng Med Biol Soc 2011, 2011:1831-1834.
    • (2011) Conf Proc IEEE Eng Med Biol Soc , vol.2011 , pp. 1831-1834
    • Lange, B.1    Chang, C.Y.2    Suma, E.3    Newman, B.4    Rizzo, A.5    Bolas, M.6
  • 18
    • 0344906131 scopus 로고    scopus 로고
    • An algorithm for determining gravity line location from posturographic recordings
    • Zatsiorsky V., King D. An algorithm for determining gravity line location from posturographic recordings. J Biomech 1998, 31:161-164.
    • (1998) J Biomech , vol.31 , pp. 161-164
    • Zatsiorsky, V.1    King, D.2
  • 20
    • 0033936333 scopus 로고    scopus 로고
    • Measures of reliability in sports medicine and science
    • Hopkins W.G. Measures of reliability in sports medicine and science. Sports Med 2000, 30(1):1-15.
    • (2000) Sports Med , vol.30 , Issue.1 , pp. 1-15
    • Hopkins, W.G.1
  • 22
    • 27244434802 scopus 로고    scopus 로고
    • Postural control of patients with hemiparesis: force plates measurements based on the clinical sensory organization test
    • Laufer Y., Schwarzmann R., Sivan D., Sprecher E. Postural control of patients with hemiparesis: force plates measurements based on the clinical sensory organization test. Physiother Theory Pract 2005, 21(3):163-171.
    • (2005) Physiother Theory Pract , vol.21 , Issue.3 , pp. 163-171
    • Laufer, Y.1    Schwarzmann, R.2    Sivan, D.3    Sprecher, E.4
  • 23
    • 0028885338 scopus 로고
    • Biomechanical assessment of quiet standing and changes associated with aging
    • Panzer V.P., Bandinelli S., Hallett M. Biomechanical assessment of quiet standing and changes associated with aging. Arch Phys Med Rehabil 1995, 76(2):151-157.
    • (1995) Arch Phys Med Rehabil , vol.76 , Issue.2 , pp. 151-157
    • Panzer, V.P.1    Bandinelli, S.2    Hallett, M.3
  • 24
    • 0036146958 scopus 로고    scopus 로고
    • Reliability and validity of standing balance measurements with a motion analysis system
    • Kejonen P., Kauranen K. Reliability and validity of standing balance measurements with a motion analysis system. Physiother 2002, 88(1):25-32.
    • (2002) Physiother , vol.88 , Issue.1 , pp. 25-32
    • Kejonen, P.1    Kauranen, K.2
  • 26
    • 0029973159 scopus 로고    scopus 로고
    • Intra-subject inconsistencies in quantitative assessment of body sway
    • Samson M., Crowe A. Intra-subject inconsistencies in quantitative assessment of body sway. Gait Posture 1996, 4:252-257.
    • (1996) Gait Posture , vol.4 , pp. 252-257
    • Samson, M.1    Crowe, A.2
  • 27
    • 17444365483 scopus 로고    scopus 로고
    • Human postural sway results from frequent, ballistic bias impulses by soleus and gastrocnemius
    • Loram I.D., Maganaris C.N., Lakie M. Human postural sway results from frequent, ballistic bias impulses by soleus and gastrocnemius. J Physiol 2005, 564(1):295-311.
    • (2005) J Physiol , vol.564 , Issue.1 , pp. 295-311
    • Loram, I.D.1    Maganaris, C.N.2    Lakie, M.3
  • 28
    • 84890399408 scopus 로고    scopus 로고
    • Enhanced computer vision with Microsoft Kinect sensor: a review
    • Han J., Shao L., Xu D., Shotton J. Enhanced computer vision with Microsoft Kinect sensor: a review. IEEE Trans Cybernetics 2013, 43(5):1318-1334.
    • (2013) IEEE Trans Cybernetics , vol.43 , Issue.5 , pp. 1318-1334
    • Han, J.1    Shao, L.2    Xu, D.3    Shotton, J.4
  • 29
    • 84857612141 scopus 로고    scopus 로고
    • Accuracy and resolution of Kinect depth data for indoor mapping applications
    • Khoshelham K., Elberink S.O. Accuracy and resolution of Kinect depth data for indoor mapping applications. Sensors 2012, 12:1437-1454.
    • (2012) Sensors , vol.12 , pp. 1437-1454
    • Khoshelham, K.1    Elberink, S.O.2
  • 30
    • 76749151849 scopus 로고    scopus 로고
    • Validity and reliability of the Nintendo Wii Balance Board for assessment of standing balance
    • Clark R.A., Bryant A.L., Pua Y., McCrory P., Bennell K., Hunt M. Validity and reliability of the Nintendo Wii Balance Board for assessment of standing balance. Gait Posture 2010, 31:307-310.
    • (2010) Gait Posture , vol.31 , pp. 307-310
    • Clark, R.A.1    Bryant, A.L.2    Pua, Y.3    McCrory, P.4    Bennell, K.5    Hunt, M.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.