-
1
-
-
84868647372
-
Archie Brain: Celebrating 30 years of development in laryngeal mask airways
-
Van Zundert T, Brimacombe J, Ferson D, Bacon D, Wilkinson D. Archie Brain: celebrating 30 years of development in laryngeal mask airways. Anaesthesia 2012; 67: 1375-85.
-
(2012)
Anaesthesia
, vol.67
, pp. 1375-1385
-
-
Van Zundert, T.1
Brimacombe, J.2
Ferson, D.3
Bacon, D.4
Wilkinson, D.5
-
2
-
-
0020595084
-
The laryngeal mask - A new concept in airway management
-
Brain AIJ. The laryngeal mask - a new concept in airway management. British Journal of Anaesthesia 1983; 55: 801-5.
-
(1983)
British Journal of Anaesthesia
, vol.55
, pp. 801-805
-
-
Brain, A.I.J.1
-
3
-
-
84890527231
-
New supraglottic airway with built-in pressure indicator decreases postoperative pharyngolaryngeal symptoms: A randomized controlled trial
-
Wong D, Tam A, Mehta V, Raveendran R, Riad W, Chung F. New supraglottic airway with built-in pressure indicator decreases postoperative pharyngolaryngeal symptoms: a randomized controlled trial. Canadian Journal of Anesthesia 2013; 60: 1197-203.
-
(2013)
Canadian Journal of Anesthesia
, vol.60
, pp. 1197-1203
-
-
Wong, D.1
Tam, A.2
Mehta, V.3
Raveendran, R.4
Riad, W.5
Chung, F.6
-
4
-
-
84921948272
-
-
LMA Company, accessed 17/05/2014
-
LMA Instruction Manual. LMA Company, 2010. http://www.lmaco.com/viewifu.php?ifu=16 (accessed 17/05/2014).
-
(2010)
LMA Instruction Manual
-
-
-
5
-
-
84921969437
-
-
LMA Company, accessed 17/05/2014
-
LMA Supreme Instruction Manual. LMA Company, 2010. http://www.lmaco.com/viewifu.php?ifu=18 (accessed 17/05/2014).
-
(2010)
LMA Supreme Instruction Manual
-
-
-
6
-
-
84921990962
-
-
LMA Company, accessed 17/05/2014
-
Proseal LMA Instruction Manual. LMA Company, 2013. http://www.lmaco.com/viewifu.php?ifu=19 (accessed 17/05/2014).
-
(2013)
Proseal LMA Instruction Manual
-
-
-
8
-
-
84921993080
-
Prospective audit to determine endotracheal tube and laryngeal mask airway cuff pressures during general anaesthesia
-
Sandhu G, Thanawala V, Flack J. Prospective audit to determine endotracheal tube and laryngeal mask airway cuff pressures during general anaesthesia. Anaesthesia 2012; 67(Suppl 2): 67.
-
(2012)
Anaesthesia
, vol.67
, pp. 67
-
-
Sandhu, G.1
Thanawala, V.2
Flack, J.3
-
9
-
-
65349195540
-
Impact of laryngeal mask airway cuff pressures on the incidence of sore throat in children
-
Wong J, Heaney M, Chambers N, Erb T, Von Ungern-Sternberg B. Impact of laryngeal mask airway cuff pressures on the incidence of sore throat in children. Pediatric Anesthesia 2009; 19: 464-9.
-
(2009)
Pediatric Anesthesia
, vol.19
, pp. 464-469
-
-
Wong, J.1
Heaney, M.2
Chambers, N.3
Erb, T.4
Von Ungern-Sternberg, B.5
-
11
-
-
0342902625
-
The effect of laryngeal mask cuff pressure on postoperative sore throat incidence
-
Burgard G, Möllhoff T, Prien T. The effect of laryngeal mask cuff pressure on postoperative sore throat incidence. Journal of Clinical Anesthesia 1996; 8: 198-201.
-
(1996)
Journal of Clinical Anesthesia
, vol.8
, pp. 198-201
-
-
Burgard, G.1
Möllhoff, T.2
Prien, T.3
-
12
-
-
0032776144
-
Comparison of the flexible and standard laryngeal mask airways
-
Brimacombe J, Keller C. Comparison of the flexible and standard laryngeal mask airways. Canadian Journal of Anesthesia 1999; 46: 558-63.
-
(1999)
Canadian Journal of Anesthesia
, vol.46
, pp. 558-563
-
-
Brimacombe, J.1
Keller, C.2
-
13
-
-
0033029578
-
Calculated vs measured pharyngeal mucosal pressures with the laryngeal mask airway during cuff inflation: Assessment of four locations
-
Keller C, Brimacombe J, Benzer A. Calculated vs measured pharyngeal mucosal pressures with the laryngeal mask airway during cuff inflation: assessment of four locations. British Journal of Anaesthesia 1999; 82: 399-401.
-
(1999)
British Journal of Anaesthesia
, vol.82
, pp. 399-401
-
-
Keller, C.1
Brimacombe, J.2
Benzer, A.3
-
14
-
-
0033858697
-
Mucosal pressure and oropharyngeal leak pressure with the ProSeal Vs laryngeal mask airway in anaesthetized paralysed patients
-
Keller C, Brimacombe J. Mucosal pressure and oropharyngeal leak pressure with the ProSeal Vs laryngeal mask airway in anaesthetized paralysed patients. British Journal of Anaesthesia 2000; 85: 262-6.
-
(2000)
British Journal of Anaesthesia
, vol.85
, pp. 262-266
-
-
Keller, C.1
Brimacombe, J.2
-
16
-
-
84878480172
-
Comparison of cuff-pressure changes in silicone and PVC laryngeal masks during nitrous oxide anaesthesia in spontaneously breathing children
-
Van Zundert T, Brimacombe J. Comparison of cuff-pressure changes in silicone and PVC laryngeal masks during nitrous oxide anaesthesia in spontaneously breathing children. Anaesthesiology Intensive Therapy 2012; 44: 63-70.
-
(2012)
Anaesthesiology Intensive Therapy
, vol.44
, pp. 63-70
-
-
Van Zundert, T.1
Brimacombe, J.2
-
17
-
-
14644432390
-
Nitrous oxide diffusion into the cuffs of disposable laryngeal mask airways
-
Maino P, Dullenkopf A, Bernet V, Weiss M. Nitrous oxide diffusion into the cuffs of disposable laryngeal mask airways. Anaesthesia 2005; 60: 278-82.
-
(2005)
Anaesthesia
, vol.60
, pp. 278-282
-
-
Maino, P.1
Dullenkopf, A.2
Bernet, V.3
Weiss, M.4
-
18
-
-
77649165501
-
Use of manometry for laryngeal mask airway reduces postoperative pharyngolaryngeal adverse events
-
Seet E, Yousaf F, Gupta S, Subramanyam R, Wong D, Chung F. Use of manometry for laryngeal mask airway reduces postoperative pharyngolaryngeal adverse events. Anesthesiology 2010; 112: 652-7.
-
(2010)
Anesthesiology
, vol.112
, pp. 652-657
-
-
Seet, E.1
Yousaf, F.2
Gupta, S.3
Subramanyam, R.4
Wong, D.5
Chung, F.6
-
19
-
-
0034037734
-
Emergence characteristics and post-operative laryngopharyngeal morbidity with the laryngeal mask airway: A comparison of high versus low initial cuff volume
-
Brimacombe J, Holyoake L, Keller C, et al. Emergence characteristics and post-operative laryngopharyngeal morbidity with the laryngeal mask airway: a comparison of high versus low initial cuff volume. Anaesthesia 2000; 55: 338-43.
-
(2000)
Anaesthesia
, vol.55
, pp. 338-343
-
-
Brimacombe, J.1
Holyoake, L.2
Keller, C.3
-
20
-
-
0034120342
-
Effect of high laryngeal mask airway intra cuff pressure on the laryngopharyngeal mucosa of dogs
-
Martins R, Braz J, Defaveri J, Gregório E, Abud T. Effect of high laryngeal mask airway intra cuff pressure on the laryngopharyngeal mucosa of dogs. Laryngoscope 2000; 110: 645-50.
-
(2000)
Laryngoscope
, vol.110
, pp. 645-650
-
-
Martins, R.1
Braz, J.2
Defaveri, J.3
Gregório, E.4
Abud, T.5
-
21
-
-
35349005897
-
Laryngopharyngeal mucosal injury after prolonged use of the ProSeal LMA in a porcine model: A pilot study
-
Goldmann K, Dieterich J, Roessler M. Laryngopharyngeal mucosal injury after prolonged use of the ProSeal LMA in a porcine model: a pilot study. Canadian Journal of Anesthesia 2007; 54: 822-8.
-
(2007)
Canadian Journal of Anesthesia
, vol.54
, pp. 822-828
-
-
Goldmann, K.1
Dieterich, J.2
Roessler, M.3
-
22
-
-
0027530403
-
Pressure exerted by the laryngeal mask airway cuff upon the pharyngeal mucosa
-
Marjot R. Pressure exerted by the laryngeal mask airway cuff upon the pharyngeal mucosa. British Journal of Anaesthesia 1993; 70: 25-9.
-
(1993)
British Journal of Anaesthesia
, vol.70
, pp. 25-29
-
-
Marjot, R.1
-
24
-
-
0033918203
-
Pharyngolaryngeal, neck, and jaw discomfort after anesthesia with the face mask and laryngeal mask airway at high and low cuff volumes in males and females
-
Brimacombe J, Holyoake L, Keller C, et al. Pharyngolaryngeal, neck, and jaw discomfort after anesthesia with the face mask and laryngeal mask airway at high and low cuff volumes in males and females. Anesthesiology 2000; 93: 26-31.
-
(2000)
Anesthesiology
, vol.93
, pp. 26-31
-
-
Brimacombe, J.1
Holyoake, L.2
Keller, C.3
-
25
-
-
0031842373
-
Reducing the incidence of sore throat with the laryngeal mask airway
-
Nott M, Noble P, Parmar M. Reducing the incidence of sore throat with the laryngeal mask airway. European Journal of Anaesthesiology 1998; 15: 153-7.
-
(1998)
European Journal of Anaesthesiology
, vol.15
, pp. 153-157
-
-
Nott, M.1
Noble, P.2
Parmar, M.3
-
26
-
-
80155212606
-
Effect of continuous cuff pressure regulator in general anaesthesia with laryngeal mask airway
-
Jeon Y-S, Choi J-W, Jung H-S, et al. Effect of continuous cuff pressure regulator in general anaesthesia with laryngeal mask airway. Journal of International Medical Research 2011; 39: 1900-7.
-
(2011)
Journal of International Medical Research
, vol.39
, pp. 1900-1907
-
-
Jeon, Y.-S.1
Choi, J.-W.2
Jung, H.-S.3
-
27
-
-
0030824693
-
Intra-cuff pressures do not predict laryngopharyngeal discomfort after use of the laryngeal mask airway
-
Rieger A, Brunne B, Striebel H. Intra-cuff pressures do not predict laryngopharyngeal discomfort after use of the laryngeal mask airway. Anesthesiology 1997; 87: 63-7.
-
(1997)
Anesthesiology
, vol.87
, pp. 63-67
-
-
Rieger, A.1
Brunne, B.2
Striebel, H.3
-
28
-
-
0035143385
-
Post-operative recovery: Day surgery patients' preferences
-
Jenkins K, Grady D, Wong J, Correa R, Armanious S, Chung F. Post-operative recovery: day surgery patients' preferences. British Journal of Anaesthesia 2001; 86: 272-4.
-
(2001)
British Journal of Anaesthesia
, vol.86
, pp. 272-274
-
-
Jenkins, K.1
Grady, D.2
Wong, J.3
Correa, R.4
Armanious, S.5
Chung, F.6
-
29
-
-
0032948115
-
Which clinical anesthesia outcomes are both common and important to avoid? The persepective of a panel of expert anesthesiologists
-
Macario A, Weinger M, Truong P, Lee M. Which clinical anesthesia outcomes are both common and important to avoid? The persepective of a panel of expert anesthesiologists. Anesthesia and Analgesia 1999; 88: 1085-91.
-
(1999)
Anesthesia and Analgesia
, vol.88
, pp. 1085-1091
-
-
Macario, A.1
Weinger, M.2
Truong, P.3
Lee, M.4
-
30
-
-
0031818717
-
Influence of cuff volume on oropharyngeal leak pressure and fibreoptic position with the laryngeal mask airway
-
Keller C, Pühringer F, Brimacombe J. Influence of cuff volume on oropharyngeal leak pressure and fibreoptic position with the laryngeal mask airway. British Journal of Anaesthesia 1998; 81: 186-7.
-
(1998)
British Journal of Anaesthesia
, vol.81
, pp. 186-187
-
-
Keller, C.1
Pühringer, F.2
Brimacombe, J.3
-
31
-
-
0347589451
-
A comparison of endotracheal tube cuff pressures using estimation techniques and direct intra-cuff measurement
-
Stewart S, Secrest J, Norwood B, Zachary R. A comparison of endotracheal tube cuff pressures using estimation techniques and direct intra-cuff measurement. AANA Journal 2003; 71: 443-7.
-
(2003)
AANA Journal
, vol.71
, pp. 443-447
-
-
Stewart, S.1
Secrest, J.2
Norwood, B.3
Zachary, R.4
-
32
-
-
84868383451
-
Excessive endotracheal tube cuff pressure: Is there any difference between emergency physicians and anesthesiologists?
-
Ghafouri H-B, Saeeidi H, Yasinzadeh M, Famouri S, Modirian E. Excessive endotracheal tube cuff pressure: Is there any difference between emergency physicians and anesthesiologists? Signa Vitae 2012; 7: 17-20.
-
(2012)
Signa Vitae
, vol.7
, pp. 17-20
-
-
Ghafouri, H.-B.1
Saeeidi, H.2
Yasinzadeh, M.3
Famouri, S.4
Modirian, E.5
-
34
-
-
0032910398
-
Laryngeal mask airway intra-cuff pressure estimation by digital palpation of the pilot balloon: A comparison of reusable and disposable masks
-
Keller C, Brimacombe J. Laryngeal mask airway intra-cuff pressure estimation by digital palpation of the pilot balloon: a comparison of reusable and disposable masks. Anaesthesia 1999; 54: 183-6.
-
(1999)
Anaesthesia
, vol.54
, pp. 183-186
-
-
Keller, C.1
Brimacombe, J.2
-
35
-
-
0030077068
-
Recurrent laryngeal nerve palsy after laryngeal mask airway insertion
-
Lloyd Jones F, Hegab A. Recurrent laryngeal nerve palsy after laryngeal mask airway insertion. Anaesthesia 1996; 51: 171-2.
-
(1996)
Anaesthesia
, vol.51
, pp. 171-172
-
-
Lloyd Jones, F.1
Hegab, A.2
-
36
-
-
4444378186
-
Venous congestion of the neck; its relation to laryngeal mask cuff pressures letter
-
Lenoir R. Venous congestion of the neck; its relation to laryngeal mask cuff pressures letter. British Journal of Anaesthesia 2004; 93: 476-7.
-
(2004)
British Journal of Anaesthesia
, vol.93
, pp. 476-477
-
-
Lenoir, R.1
-
37
-
-
57349166088
-
Oesophageal seal of the novel supralaryngeal airway device I-Gel™ in comparison with the laryngeal mask airways Classic™ and ProSeal™ using a cadaver model
-
Schmidbauer W, Bercker S, Volk T, Bogusch G, Mager G, Kerner T. Oesophageal seal of the novel supralaryngeal airway device I-Gel™ in comparison with the laryngeal mask airways Classic™ and ProSeal™ using a cadaver model. British Journal of Anaesthesia 2009; 102: 135-9.
-
(2009)
British Journal of Anaesthesia
, vol.102
, pp. 135-139
-
-
Schmidbauer, W.1
Bercker, S.2
Volk, T.3
Bogusch, G.4
Mager, G.5
Kerner, T.6
-
38
-
-
51349105384
-
Lower cuff pressures improve the seal of pediatric laryngeal mask airways
-
Licina A, Chambers N, Hullett B, Erb T, Von Ungern-Sternberg B. Lower cuff pressures improve the seal of pediatric laryngeal mask airways. Pediatric Anesthesia 2008; 18: 952-6.
-
(2008)
Pediatric Anesthesia
, vol.18
, pp. 952-956
-
-
Licina, A.1
Chambers, N.2
Hullett, B.3
Erb, T.4
Von Ungern-Sternberg, B.5
-
39
-
-
84921947990
-
Cuff pressure monitoring in paediatric laryngeal mask airways: Is it worth the pain?
-
Invited Papers and Selected Continuing Education Lectures. Riley E, ed. Melbourne: Australian and New Zealand College of Anaesthetists, 2009 accessed 13/09/2014
-
Von Ungern-Sternberg B. Cuff pressure monitoring in paediatric laryngeal mask airways: is it worth the pain? Australasian Anaesthesia 2009. Invited Papers and Selected Continuing Education Lectures. Riley E, ed. Melbourne: Australian and New Zealand College of Anaesthetists, 2009: 55-7. http://www.anzca.edu.au/resources/college-publications/pdfs/Australasian%20Anaesthesia%202009.pdf (accessed 13/09/2014).
-
(2009)
Australasian Anaesthesia
, pp. 55-57
-
-
Von Ungern-Sternberg, B.1
-
40
-
-
43449084626
-
Problems with laryngeal mask airway cuff pressure
-
Mandal N. Problems with laryngeal mask airway cuff pressure. Canadian Journal of Anesthesia 2008; 55: 312-3.
-
(2008)
Canadian Journal of Anesthesia
, vol.55
, pp. 312-313
-
-
Mandal, N.1
-
42
-
-
0033636120
-
Review article: Cuff volume and size selection with the laryngeal mask
-
Asai T, Brimacombe J. Review article: cuff volume and size selection with the laryngeal mask. Anaesthesia 2000; 55: 1179-84.
-
(2000)
Anaesthesia
, vol.55
, pp. 1179-1184
-
-
Asai, T.1
Brimacombe, J.2
-
43
-
-
84655167838
-
Using the inflating syringe as a safety valve to limit laryngeal mask airway cuff pressure
-
Rice M, Gravenstein NL, Brull S, Morey T, Gravenstein N. Using the inflating syringe as a safety valve to limit laryngeal mask airway cuff pressure. Journal of Clinical Monitoring and Computing 2011; 25: 405-10.
-
(2011)
Journal of Clinical Monitoring and Computing
, vol.25
, pp. 405-410
-
-
Rice, M.1
Gravenstein, N.L.2
Brull, S.3
Morey, T.4
Gravenstein, N.5
|