메뉴 건너뛰기




Volumn 25, Issue 6, 2011, Pages 405-410

Using the inflating syringe as a safety valve to limit laryngeal mask airway cuff pressure

Author keywords

airway management; cuff pressure; laryngeal mask airway; laryngeal masks; postoperative complications

Indexed keywords

AIRWAY MANAGEMENT; CUFF PRESSURE; DIRECT MEASUREMENT; INFLATION PRESSURES; LARYNGEAL MASK AIRWAY; MAXIMUM VALUES; POSTOPERATIVE COMPLICATIONS; STARTING PRESSURE;

EID: 84655167838     PISSN: 13871307     EISSN: 15732614     Source Type: Journal    
DOI: 10.1007/s10877-011-9319-8     Document Type: Article
Times cited : (8)

References (16)
  • 1
    • 0028355548 scopus 로고
    • A comparative study of the incidence of sore throat with the laryngeal mask airway
    • J Dingley MJ Whitehead K Wareham 1994 A comparative study of the incidence of sore throat with the laryngeal mask airway Anaesthesia 49 251 254 8147523 10.1111/j.1365-2044.1994.tb03434.x 1:STN:280:DyaK2c7pslegtQ%3D%3D (Pubitemid 24089632)
    • (1994) Anaesthesia , vol.49 , Issue.3 , pp. 251-254
    • Dingley, J.1    Whitehead, M.J.2    Wareham, K.3
  • 2
    • 0030759970 scopus 로고    scopus 로고
    • The laryngeal mask airway: A comparison between two insertion techniques
    • DOI 10.1097/00000539-199709000-00037
    • HG Wakeling PJ Butler PJ Baxter 1997 The laryngeal mask airway: a comparison between two insertion techniques Anesth Analg 85 687 690 9296432 1:STN:280:DyaK2svktV2ksQ%3D%3D (Pubitemid 27381330)
    • (1997) Anesthesia and Analgesia , vol.85 , Issue.3 , pp. 687-690
    • Wakeling, H.G.1    Butler, P.J.2    Baxter, P.J.C.3
  • 3
    • 77649165501 scopus 로고    scopus 로고
    • Use of manometry for laryngeal mask airway reduces postoperative pharyngolaryngeal adverse events
    • 20179502 10.1097/ALN.0b013e3181cf4346
    • E Seet F Yousaf S Gupta R Subramanyam DT Wong F Chung 2010 Use of manometry for laryngeal mask airway reduces postoperative pharyngolaryngeal adverse events Anesthesiology 112 652 657 20179502 10.1097/ALN.0b013e3181cf4346
    • (2010) Anesthesiology , vol.112 , pp. 652-657
    • Seet, E.1    Yousaf, F.2    Gupta, S.3    Subramanyam, R.4    Wong, D.T.5    Chung, F.6
  • 4
    • 0029907755 scopus 로고    scopus 로고
    • Arytenoid cartilage dislocation caused by a laryngeal mask airway treated with chemical splinting
    • MK Rosenberg E Rontal M Rontal M Lebenbom-Mansour 1996 Arytenoid cartilage dislocation caused by a laryngeal mask airway treated with chemical splinting Anesth Analg 83 1335 1336 8942611 1:STN:280:DyaK2s%2FpvVSksg%3D%3D (Pubitemid 26418829)
    • (1996) Anesthesia and Analgesia , vol.83 , Issue.6 , pp. 1335-1336
    • Rosenberg, M.K.1    Rontal, E.2    Rontal, M.3    Lebenbom-Mansour, M.4
  • 5
    • 0029838894 scopus 로고    scopus 로고
    • Lingual nerve paralysis following the use of the laryngeal mask airway
    • CH Laxton R Kipling 1996 Lingual nerve paralysis following the use of the laryngeal mask airway Anaesthesia 51 869 870 8882254 10.1111/j.1365-2044.1996. tb12621.x 1:STN:280:DyaK2s%2Fjs1KjtA%3D%3D (Pubitemid 26305871)
    • (1996) Anaesthesia , vol.51 , Issue.9 , pp. 869-870
    • Laxton, C.H.1    Kipling, R.2
  • 6
    • 0025831826 scopus 로고
    • Trauma to the posterior pharyngeal wall caused by a laryngeal mask airway
    • 10.1111/j.1365-2044.1991.tb09668.x
    • R Marjot 1991 Trauma to the posterior pharyngeal wall caused by a laryngeal mask airway Anaesthesia 41 589 590 10.1111/j.1365-2044.1991.tb09668.x
    • (1991) Anaesthesia , vol.41 , pp. 589-590
    • Marjot, R.1
  • 7
    • 0028930622 scopus 로고
    • Transient bilateral vocal cord paralysis after insertion of a laryngeal mask airway
    • 7879948 10.1097/00000542-199503000-00023 1:STN:280:DyaK2M7osFKlsQ%3D%3D
    • S Inomata T Nishikawa A Suga S Yamashita 1995 Transient bilateral vocal cord paralysis after insertion of a laryngeal mask airway Anesthesiology 82 787 788 7879948 10.1097/00000542-199503000-00023 1:STN:280:DyaK2M7osFKlsQ%3D%3D
    • (1995) Anesthesiology , vol.82 , pp. 787-788
    • Inomata, S.1    Nishikawa, T.2    Suga, A.3    Yamashita, S.4
  • 8
    • 51349105384 scopus 로고    scopus 로고
    • Lower cuff pressures improve the seal of pediatric laryngeal mask airways
    • 18647269 10.1111/j.1460-9592.2008.02706.x
    • A Licina NA Chambers B Hullett TO Erb BS von Ungern-Sternberg 2008 Lower cuff pressures improve the seal of pediatric laryngeal mask airways Paediatr Anaesth 18 952 956 18647269 10.1111/j.1460-9592.2008.02706.x
    • (2008) Paediatr Anaesth , vol.18 , pp. 952-956
    • Licina, A.1    Chambers, N.A.2    Hullett, B.3    Erb, T.O.4    Von Ungern-Sternberg, B.S.5
  • 9
    • 0030160460 scopus 로고    scopus 로고
    • Pressure in laryngeal mask airway cuffs
    • 8694225 10.1111/j.1365-2044.1996.tb12581.x 1:STN:280:DyaK283ps1ykuw%3D%3D
    • AI Brain 1996 Pressure in laryngeal mask airway cuffs Anaesthesia 51 603 8694225 10.1111/j.1365-2044.1996.tb12581.x 1:STN:280:DyaK283ps1ykuw%3D%3D
    • (1996) Anaesthesia , vol.51 , pp. 603
    • Brain, A.I.1
  • 10
    • 44949248131 scopus 로고    scopus 로고
    • Laryngeal mask airway and tracheal tube cuff pressures in children: Are clinical endpoints valuable for guiding inflation?
    • DOI 10.1111/j.1365-2044.2008.05486.x
    • M Ong NA Chambers B Hullett TO Erb BS von Ungern-Sternberg 2008 Laryngeal mask airway and tracheal tube cuff pressures in children: are clinical endpoints valuable for guiding inflation? Anaesthesia 63 738 744 18582260 10.1111/j.1365-2044.2008.05486.x 1:STN:280:DC%2BD1cvhtlamtw%3D%3D (Pubitemid 351814236)
    • (2008) Anaesthesia , vol.63 , Issue.7 , pp. 738-744
    • Ong, M.1    Chambers, N.A.2    Hullet, B.3    Erb, T.O.4    Von Ungern-Sternberg, B.S.5
  • 11
    • 33645234921 scopus 로고    scopus 로고
    • Cuff filling volumes and pressures in pediatric laryngeal mask airways
    • 16409525 10.1111/j.1460-9592.2005.01672.x
    • P Maino A Dullenkopf C Keller V Bernet-Buettiker M Weiss 2006 Cuff filling volumes and pressures in pediatric laryngeal mask airways Paediatr Anaesth 16 25 30 16409525 10.1111/j.1460-9592.2005.01672.x
    • (2006) Paediatr Anaesth , vol.16 , pp. 25-30
    • Maino, P.1    Dullenkopf, A.2    Keller, C.3    Bernet-Buettiker, V.4    Weiss, M.5
  • 12
    • 84655172144 scopus 로고    scopus 로고
    • LMA cuff pressure: An audit (abstract)
    • M Haldar P Immanuel 2008 LMA cuff pressure: an audit (abstract) Anesthesiology 109 A1720
    • (2008) Anesthesiology , vol.109 , pp. 1720
    • Haldar, M.1    Immanuel, P.2
  • 13
    • 4444378186 scopus 로고    scopus 로고
    • Venous congestion of the neck; its relation to laryngeal mask cuff pressures [12]
    • DOI 10.1093/bja/aeh603
    • RJ Lenoir 2004 Venous congestion of the neck; its relation to laryngeal mask cuff pressure Br J Anesth 93 476 477 10.1093/bja/aeh603 1:STN:280:DC%2BD2cvgtVygtw%3D%3D (Pubitemid 39206926)
    • (2004) British Journal of Anaesthesia , vol.93 , Issue.3 , pp. 476-477
    • Lenoir, R.J.1
  • 16
    • 14644432390 scopus 로고    scopus 로고
    • Nitrous oxide diffusion into the cuffs of disposable laryngeal mask airways
    • DOI 10.1111/j.1365-2044.2004.04072.x
    • P Maino A Dullenkopf V Bernet M Weiss 2005 Nitrous oxide diffusion into the cuffs of disposable laryngeal mask airways Anaesthesia 60 278 282 15710013 10.1111/j.1365-2044.2004.04072.x 1:STN:280:DC%2BD2M%2FotVOgtg%3D%3D (Pubitemid 40310209)
    • (2005) Anaesthesia , vol.60 , Issue.3 , pp. 278-282
    • Maino, P.1    Dullenkopf, A.2    Bernet, V.3    Weiss, M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.