-
1
-
-
78651489838
-
Changes in trabecular and cortical bone microarchitecture at peripheral sites associated with 18 months of teriparatide therapy in postmenopausal women with osteoporosis
-
Macdonald H.M., Nishiyama K.K., Hanley D.A., Boyd S.K. Changes in trabecular and cortical bone microarchitecture at peripheral sites associated with 18 months of teriparatide therapy in postmenopausal women with osteoporosis. Osteoporos Int 2011, 22:357-362.
-
(2011)
Osteoporos Int
, vol.22
, pp. 357-362
-
-
Macdonald, H.M.1
Nishiyama, K.K.2
Hanley, D.A.3
Boyd, S.K.4
-
2
-
-
0037369113
-
Effects of teriparatide [recombinant human parathyroid hormone (1-34)] on cortical bone in postmenopausal women with osteoporosis
-
Zanchetta J.R., Bogado C.E., Ferretti J.L., et al. Effects of teriparatide [recombinant human parathyroid hormone (1-34)] on cortical bone in postmenopausal women with osteoporosis. J Bone Miner Res 2003, 18(3):539-543.
-
(2003)
J Bone Miner Res
, vol.18
, Issue.3
, pp. 539-543
-
-
Zanchetta, J.R.1
Bogado, C.E.2
Ferretti, J.L.3
-
3
-
-
0028790522
-
Multicenter German reference data base for peripheral quantitative computer tomography
-
Schneider P., Butz S., Allolio B., et al. Multicenter German reference data base for peripheral quantitative computer tomography. Technol Health Care 1995, 3(2):69-73.
-
(1995)
Technol Health Care
, vol.3
, Issue.2
, pp. 69-73
-
-
Schneider, P.1
Butz, S.2
Allolio, B.3
-
4
-
-
27944449749
-
Invivo assessment of trabecular bone microarchitecture by high-resolution peripheral quantitative computed tomography
-
Boutroy S., Bouxsein M.L., Munoz F., Delmas P.D. Invivo assessment of trabecular bone microarchitecture by high-resolution peripheral quantitative computed tomography. J Clin Endocrinol Metab 2005, 90(12):6508-6515.
-
(2005)
J Clin Endocrinol Metab
, vol.90
, Issue.12
, pp. 6508-6515
-
-
Boutroy, S.1
Bouxsein, M.L.2
Munoz, F.3
Delmas, P.D.4
-
5
-
-
33751383444
-
Quantitative MRI for the assessment of bone structure and function
-
Wehrli F.W., Song H.K., Saha P.K., Wright A.C. Quantitative MRI for the assessment of bone structure and function. NMR Biomed 2006, 19(7):731-764.
-
(2006)
NMR Biomed
, vol.19
, Issue.7
, pp. 731-764
-
-
Wehrli, F.W.1
Song, H.K.2
Saha, P.K.3
Wright, A.C.4
-
6
-
-
0031032218
-
High resolution magnetic resonance imaging of the calcaneus: age-related changes in trabecular structure and comparison with dual X-ray absorptiometry measurements
-
Ouyang X., Selby K., Lang P., et al. High resolution magnetic resonance imaging of the calcaneus: age-related changes in trabecular structure and comparison with dual X-ray absorptiometry measurements. Calcif Tissue Int 1997, 60(2):139-147.
-
(1997)
Calcif Tissue Int
, vol.60
, Issue.2
, pp. 139-147
-
-
Ouyang, X.1
Selby, K.2
Lang, P.3
-
7
-
-
0034080996
-
Age-related changes assessed by peripheral QCT in healthy Italian women
-
Guglielmi G., De Serio A., Fusilli S., et al. Age-related changes assessed by peripheral QCT in healthy Italian women. Eur Radiol 2000, 10(4):609-614.
-
(2000)
Eur Radiol
, vol.10
, Issue.4
, pp. 609-614
-
-
Guglielmi, G.1
De Serio, A.2
Fusilli, S.3
-
8
-
-
78650928558
-
Bone strength measured by peripheral quantitative computed tomography and the risk of nonvertebral fractures: the osteoporotic fractures in men (MrOS) study
-
Sheu Y., Zmuda J.M., Boudreau R.M., et al. Bone strength measured by peripheral quantitative computed tomography and the risk of nonvertebral fractures: the osteoporotic fractures in men (MrOS) study. J Bone Miner Res 2011, 26(1):63-71.
-
(2011)
J Bone Miner Res
, vol.26
, Issue.1
, pp. 63-71
-
-
Sheu, Y.1
Zmuda, J.M.2
Boudreau, R.M.3
-
9
-
-
84895008254
-
Measuring apparent trabecular structure with pQCT: a comparison with HR-pQCT
-
Lala D., Cheung A.M., Lynch C.L., et al. Measuring apparent trabecular structure with pQCT: a comparison with HR-pQCT. J Clin Densitom 2014, 17(1):47-53.
-
(2014)
J Clin Densitom
, vol.17
, Issue.1
, pp. 47-53
-
-
Lala, D.1
Cheung, A.M.2
Lynch, C.L.3
-
10
-
-
34250018006
-
Accuracy of high-resolution peripheral quantitative computed tomography for measurement of bone quality
-
MacNeil J.A., Boyd S.K. Accuracy of high-resolution peripheral quantitative computed tomography for measurement of bone quality. Med Eng Phys 2007, 29(10):1096-1105.
-
(2007)
Med Eng Phys
, vol.29
, Issue.10
, pp. 1096-1105
-
-
MacNeil, J.A.1
Boyd, S.K.2
-
11
-
-
0032779148
-
Research notes: the Canadian Multicentre Osteoporosis Study (CaMos)-background, rationale, methods
-
Kreiger N., Tenenhouse A., Joseph L., et al. Research notes: the Canadian Multicentre Osteoporosis Study (CaMos)-background, rationale, methods. Can J Aging 1999, 18(3):12.
-
(1999)
Can J Aging
, vol.18
, Issue.3
, pp. 12
-
-
Kreiger, N.1
Tenenhouse, A.2
Joseph, L.3
-
12
-
-
84860834479
-
Quality control for bone quality parameters affected by subject motion in high-resolution peripheral quantitative computed tomography
-
Pauchard Y., Liphardt A.M., Macdonald H.M., et al. Quality control for bone quality parameters affected by subject motion in high-resolution peripheral quantitative computed tomography. Bone 2012, 50(6):1304-1310.
-
(2012)
Bone
, vol.50
, Issue.6
, pp. 1304-1310
-
-
Pauchard, Y.1
Liphardt, A.M.2
Macdonald, H.M.3
-
13
-
-
0037365508
-
Invivo measurement of apparent trabecular bone structure of the radius in women with low bone density discriminates patients with recent wrist fracture from those without fracture
-
MacIntyre N.J., Adachi J.D., Webber C.E. Invivo measurement of apparent trabecular bone structure of the radius in women with low bone density discriminates patients with recent wrist fracture from those without fracture. J Clin Densitom 2003, 6(1):35-43.
-
(2003)
J Clin Densitom
, vol.6
, Issue.1
, pp. 35-43
-
-
MacIntyre, N.J.1
Adachi, J.D.2
Webber, C.E.3
-
14
-
-
4444285279
-
Interactive volume segmentation with differential image foresting transforms
-
Falcao A.X., Bergo F.P. Interactive volume segmentation with differential image foresting transforms. IEEE Trans Med Imaging 2004, 23(9):1100-1108.
-
(2004)
IEEE Trans Med Imaging
, vol.23
, Issue.9
, pp. 1100-1108
-
-
Falcao, A.X.1
Bergo, F.P.2
-
15
-
-
0742303474
-
The image foresting transform: theory, algorithms, and applications
-
Falcao A.X., Stolfi J., de Alencar Lotufo R. The image foresting transform: theory, algorithms, and applications. IEEE Trans Pattern Anal Mach Intell 2004, 26(1):19-29.
-
(2004)
IEEE Trans Pattern Anal Mach Intell
, vol.26
, Issue.1
, pp. 19-29
-
-
Falcao, A.X.1
Stolfi, J.2
de Alencar Lotufo, R.3
-
16
-
-
0344301894
-
Calibration of trabecular bone structure measurements of invivo three-dimensional peripheral quantitative computed tomography with 28-microm-resolution microcomputed tomography
-
Laib A., Ruegsegger P. Calibration of trabecular bone structure measurements of invivo three-dimensional peripheral quantitative computed tomography with 28-microm-resolution microcomputed tomography. Bone 1999, 24(1):35-39.
-
(1999)
Bone
, vol.24
, Issue.1
, pp. 35-39
-
-
Laib, A.1
Ruegsegger, P.2
-
17
-
-
0020509916
-
Relationships between surface, volume, and thickness of iliac trabecular bone in aging and in osteoporosis. Implications for the microanatomic and cellular mechanisms of bone loss
-
Parfitt A.M., Mathews C.H., Villanueva A.R., et al. Relationships between surface, volume, and thickness of iliac trabecular bone in aging and in osteoporosis. Implications for the microanatomic and cellular mechanisms of bone loss. J Clin Invest 1983, 72(4):1396-1409.
-
(1983)
J Clin Invest
, vol.72
, Issue.4
, pp. 1396-1409
-
-
Parfitt, A.M.1
Mathews, C.H.2
Villanueva, A.R.3
-
18
-
-
84867140087
-
3D Slicer as an image computing platform for the Quantitative Imaging Network
-
Fedorov A., Beichel R., Kalpathy-Cramer J., et al. 3D Slicer as an image computing platform for the Quantitative Imaging Network. Magn Reson Imaging 2012, 30(9):1323-1341.
-
(2012)
Magn Reson Imaging
, vol.30
, Issue.9
, pp. 1323-1341
-
-
Fedorov, A.1
Beichel, R.2
Kalpathy-Cramer, J.3
-
19
-
-
0029112340
-
Accurate assessment of precision errors: how to measure the reproducibility of bone densitometry techniques
-
Gluer C.C., Blake G., Lu Y., et al. Accurate assessment of precision errors: how to measure the reproducibility of bone densitometry techniques. Osteoporos Int 1995, 5(4):262-270.
-
(1995)
Osteoporos Int
, vol.5
, Issue.4
, pp. 262-270
-
-
Gluer, C.C.1
Blake, G.2
Lu, Y.3
-
20
-
-
41849133970
-
Invivo determination of bone structure in postmenopausal women: a comparison of HR-pQCT and high-field MR imaging
-
Kazakia G.J., Hyun B., Burghardt A.J., et al. Invivo determination of bone structure in postmenopausal women: a comparison of HR-pQCT and high-field MR imaging. J Bone Miner Res 2008, 23(4):463-474.
-
(2008)
J Bone Miner Res
, vol.23
, Issue.4
, pp. 463-474
-
-
Kazakia, G.J.1
Hyun, B.2
Burghardt, A.J.3
-
21
-
-
73649119539
-
Local bone enhancement fuzzy clustering for segmentation of MR trabecular bone images
-
Folkesson J., Carballido-Gamio J., Eckstein F., et al. Local bone enhancement fuzzy clustering for segmentation of MR trabecular bone images. Med Phys 2010, 37(1):295-302.
-
(2010)
Med Phys
, vol.37
, Issue.1
, pp. 295-302
-
-
Folkesson, J.1
Carballido-Gamio, J.2
Eckstein, F.3
-
22
-
-
79751527444
-
Longitudinal evaluation of the effects of alendronate on MRI bone microarchitecture in postmenopausal osteopenic women
-
Folkesson J., Goldenstein J., Carballido-Gamio J., et al. Longitudinal evaluation of the effects of alendronate on MRI bone microarchitecture in postmenopausal osteopenic women. Bone 2011, 48(3):611-621.
-
(2011)
Bone
, vol.48
, Issue.3
, pp. 611-621
-
-
Folkesson, J.1
Goldenstein, J.2
Carballido-Gamio, J.3
-
23
-
-
43149111593
-
Assessment of trabecular bone structure comparing magnetic resonance imaging at 3 Tesla with high-resolution peripheral quantitative computed tomography exvivo and invivo
-
Krug R., Carballido-Gamio J., Burghardt A.J., et al. Assessment of trabecular bone structure comparing magnetic resonance imaging at 3 Tesla with high-resolution peripheral quantitative computed tomography exvivo and invivo. Osteoporos Int 2008, 19(5):653-661.
-
(2008)
Osteoporos Int
, vol.19
, Issue.5
, pp. 653-661
-
-
Krug, R.1
Carballido-Gamio, J.2
Burghardt, A.J.3
-
24
-
-
77958463610
-
Comparison of pQCT-based measures of radial bone geometry and apparent trabecular bone structure using manufacturer and in-house developed algorithms
-
Calder K., Inglis D., MacIntyre N.J. Comparison of pQCT-based measures of radial bone geometry and apparent trabecular bone structure using manufacturer and in-house developed algorithms. J Clin Densitom 2010, 13:433-440.
-
(2010)
J Clin Densitom
, vol.13
, pp. 433-440
-
-
Calder, K.1
Inglis, D.2
MacIntyre, N.J.3
-
25
-
-
77955845468
-
Reproducibility of direct quantitative measures of cortical bone microarchitecture of the distal radius and tibia by HR-pQCT
-
Burghardt A.J., Buie H.R., Laib A., et al. Reproducibility of direct quantitative measures of cortical bone microarchitecture of the distal radius and tibia by HR-pQCT. Bone 2010, 47(3):519-528.
-
(2010)
Bone
, vol.47
, Issue.3
, pp. 519-528
-
-
Burghardt, A.J.1
Buie, H.R.2
Laib, A.3
-
26
-
-
35448947914
-
Automatic prospective registration of high-resolution trabecular bone images of the tibia
-
Blumenfeld J., Carballido-Gamio J., Krug R., et al. Automatic prospective registration of high-resolution trabecular bone images of the tibia. Ann Biomed Eng 2007, 35(11):1924-1931.
-
(2007)
Ann Biomed Eng
, vol.35
, Issue.11
, pp. 1924-1931
-
-
Blumenfeld, J.1
Carballido-Gamio, J.2
Krug, R.3
-
27
-
-
85010946177
-
Intra-operator precision for invivo high resolution pQCT scans
-
In: ISCD, ed., San Francisco, CA.
-
Cheung AM, Chan C, Ahmed F, etal 2008 Intra-operator precision for invivo high resolution pQCT scans. In: ISCD, ed. International Society for Clinical Densitometry 14th Annual Meeting, San Francisco, CA 12-15.
-
(2008)
International Society for Clinical Densitometry 14th Annual Meeting
, pp. 12-15
-
-
Cheung, A.M.1
Chan, C.2
Ahmed, F.3
|