Volumn 8, Issue 1, 2015, Pages 1-9

Annular rupture during transcatheter aortic valve replacement: Classification, pathophysiology, diagnostics, treatment approaches, and prevention

Author keywords

Annular rupture; Annulus rupture; Aortic root rupture; Complications; Device landing zone; TAVR

Indexed keywords

ANNULAR RUPTURE; AORTA ROOT; AORTA RUPTURE; CONSERVATIVE TREATMENT; DIAGNOSTIC PROCEDURE; DISEASE CLASSIFICATION; EARLY DIAGNOSIS; FATALITY; HEART LEFT VENTRICLE OUTFLOW TRACT; HUMAN; ISOLATED PERICARDIAL DRAINAGE; PATHOPHYSIOLOGY; PRIORITY JOURNAL; RARE DISEASE; REVIEW; SURGICAL DRAINAGE; TRANSCATHETER AORTIC VALVE IMPLANTATION; TREATMENT INDICATION; TREATMENT OUTCOME; ADVERSE EFFECTS; AORTA VALVE; CLASSIFICATION; DIAGNOSTIC IMAGING; HEART CATHETERIZATION; HEART INJURIES; HEART VALVE REPLACEMENT; INCIDENCE; INJURIES; MORTALITY; PREDICTIVE VALUE; PROCEDURES;

EID: 84921327041     PISSN: 19368798     EISSN: 18767605     Source Type: Journal    
DOI: 10.1016/j.jcin.2014.07.020     Document Type: Review
Times cited : (155)

References (29)
  • 1
    • 70349196461 scopus 로고    scopus 로고
    • Transcatheter aortic valve implantation: Review of the nature, management, and avoidance of procedural complications
    • Masson JB, Kovac J, Schuler G, et al. Transcatheter aortic valve implantation: review of the nature, management, and avoidance of procedural complications. J Am Coll Cardiol Intv 2009;2:811-20.
    • (2009) J Am Coll Cardiol Intv , vol.2 , pp. 811-820
    • Masson, J.B.1    Kovac, J.2    Schuler, G.3
  • 2
    • 80053949735 scopus 로고    scopus 로고
    • Incidence and treatment of procedural cardiovascular complications associated with trans-arterial and transapical interventional aortic valve implantation in 412 consecutive patients
    • Lange R, Bleiziffer S, Piazza N, et al. Incidence and treatment of procedural cardiovascular complications associated with trans-arterial and transapical interventional aortic valve implantation in 412 consecutive patients. Eur J Cardiothorac Surg 2011;40:1105-13.
    • (2011) Eur J Cardiothorac Surg , vol.40 , pp. 1105-1113
    • Lange, R.1    Bleiziffer, S.2    Piazza, N.3
  • 3
    • 84862181480 scopus 로고    scopus 로고
    • Clinical outcomes after transcatheter aortic valve replacement using valve academic research consortium definitions: A weighted meta-analysis of 3,519 patients from 16 studies
    • Généreux P, Head SJ, Van Mieghem NM, et al. Clinical outcomes after transcatheter aortic valve replacement using valve academic research consortium definitions: a weighted meta-analysis of 3,519 patients from 16 studies. J Am Coll Cardiol 2012;59:2317-26.
    • (2012) J Am Coll Cardiol , vol.59 , pp. 2317-2326
    • Généreux, P.1    Head, S.J.2    Van Mieghem, N.M.3
  • 4
    • 84871259431 scopus 로고    scopus 로고
    • Incidence, management, and outcomes of cardiac tamponade during transcatheter aortic valve implantation: A single-center study
    • Rezq A, Basavarajaiah S, Latib A, et al. Incidence, management, and outcomes of cardiac tamponade during transcatheter aortic valve implantation: a single-center study. J Am Coll Cardiol Intv 2012;5:1264-72.
    • (2012) J Am Coll Cardiol Intv , vol.5 , pp. 1264-1272
    • Rezq, A.1    Basavarajaiah, S.2    Latib, A.3
  • 5
    • 84886950729 scopus 로고    scopus 로고
    • Emergency cardiac surgery during transfemoral and transapical transcatheter aortic valve implantation: Incidence, reasons, management, and outcome of 411 patients from a single center
    • Griese DP, Reents W, Kerber S, Diegeler A, Babin-Ebell J. Emergency cardiac surgery during transfemoral and transapical transcatheter aortic valve implantation: incidence, reasons, management, and outcome of 411 patients from a single center. Catheter Cardiovasc Interv 2013;82:E726-33.
    • (2013) Catheter Cardiovasc Interv , vol.82 , pp. E726-E733
    • Griese, D.P.1    Reents, W.2    Kerber, S.3    Diegeler, A.4    Babin-Ebell, J.5
  • 6
    • 84864612719 scopus 로고    scopus 로고
    • Rupture of the device landing zone during transcatheter aortic valve implantation: A life-threatening but treatable complication
    • Pasic M, Unbehaun A, Dreysse S, et al. Rupture of the device landing zone during transcatheter aortic valve implantation: a life-threatening but treatable complication. Circ Cardiovasc Interv 2012;5:424-32.
    • (2012) Circ Cardiovasc Interv , vol.5 , pp. 424-432
    • Pasic, M.1    Unbehaun, A.2    Dreysse, S.3
  • 7
    • 84880355851 scopus 로고    scopus 로고
    • Anatomical and procedural features associated with aortic root rupture during balloon-expandable transcatheter aortic valve replacement
    • Barbanti M, Yang T-H, Rodès Cabau J, et al. Anatomical and procedural features associated with aortic root rupture during balloon-expandable transcatheter aortic valve replacement. Circulation 2013;128:244-53.
    • (2013) Circulation , vol.128 , pp. 244-253
    • Barbanti, M.1    Yang, T.-H.2    Rodès Cabau, J.3
  • 8
    • 84873197426 scopus 로고    scopus 로고
    • Emergent cardiac surgery during transcatheter aortic valve implantation (TAVI): A weighted meta-analysis of 9,251 patients from 46 studies
    • Eggebrecht H, Schmermund A, Kahlert P, Erbel R, Voigtländer T, Mehta RH. Emergent cardiac surgery during transcatheter aortic valve implantation (TAVI): a weighted meta-analysis of 9,251 patients from 46 studies. EuroIntervention 2013;8:1072-80.
    • (2013) EuroIntervention , vol.8 , pp. 1072-1080
    • Eggebrecht, H.1    Schmermund, A.2    Kahlert, P.3    Erbel, R.4    Voigtländer, T.5    Mehta, R.H.6
  • 9
    • 76649123667 scopus 로고    scopus 로고
    • Correlation of device landing zone calcification and acute procedural success in patients undergoing transcatheter aortic valve implantations with the self-expanding CoreValve prosthesis
    • John D, Buellesfeld L, Yuecel S, et al. Correlation of device landing zone calcification and acute procedural success in patients undergoing transcatheter aortic valve implantations with the self-expanding CoreValve prosthesis. J Am Coll Cardiol Intv 2010;3:233-43.
    • (2010) J Am Coll Cardiol Intv , vol.3 , pp. 233-243
    • John, D.1    Buellesfeld, L.2    Yuecel, S.3
  • 10
    • 84921393129 scopus 로고    scopus 로고
    • Available at Accessed May 16, 2014
    • Merriam-Webster Dictionary. Anulus fibrosus. Available at: http://www.merriam-webster.com/medical/anulus. Accessed May 16, 2014.
    • Anulus Fibrosus
  • 11
    • 0025781469 scopus 로고
    • The myth of the aortic annulus: The anatomy of the subaortic outflow tract
    • Anderson RH, Devine WA, Ho SY, Smith A, McKay R. The myth of the aortic annulus: the anatomy of the subaortic outflow tract. Ann Thorac Surg 1991;52:640-6.
    • (1991) Ann Thorac Surg , vol.52 , pp. 640-646
    • Anderson, R.H.1    Devine, W.A.2    Ho, S.Y.3    Smith, A.4    McKay, R.5
  • 12
    • 0023628883 scopus 로고
    • Fatal aortic rupture during percutaneous balloon valvuloplasty for valvular aortic stenosis
    • Lembo NJ, King SB 3rd, Roubin GS, Hammami A, Niederman AL. Fatal aortic rupture during percutaneous balloon valvuloplasty for valvular aortic stenosis. Am J Cardiol 1987;60:733-6.
    • (1987) Am J Cardiol , vol.60 , pp. 733-736
    • Lembo, N.J.1    King, S.B.2    Roubin, G.S.3    Hammami, A.4    Niederman, A.L.5
  • 13
    • 84886948052 scopus 로고    scopus 로고
    • Potential mechanism of annulus rupture during transcatheter aortic valve implantation
    • Hayashida K, Bouvier E, Lefèvre T, et al. Potential mechanism of annulus rupture during transcatheter aortic valve implantation. Catheter Cardiovasc Interv 2013;82:E742-6.
    • (2013) Catheter Cardiovasc Interv , vol.82 , pp. E742-E746
    • Hayashida, K.1    Bouvier, E.2    Lefèvre, T.3
  • 14
    • 84856167088 scopus 로고    scopus 로고
    • Interventricular septum rupture after transcatheter aortic valve implantation
    • Martínez MI, García HG, Calvar JA. Interventricular septum rupture after transcatheter aortic valve implantation. Eur Heart J 2012;33:190.
    • (2012) Eur Heart J , vol.33 , pp. 190
    • Martínez, M.I.1    García, H.G.2    Calvar, J.A.3
  • 15
    • 84868618362 scopus 로고    scopus 로고
    • Prosthesis oversizing in balloon-expandable transcatheter aortic valve implantation is associated with contained rupture of the aortic root
    • Blanke P, Reinöhl J, Schlensak C, et al. Prosthesis oversizing in balloon-expandable transcatheter aortic valve implantation is associated with contained rupture of the aortic root. Circ Cardiovasc Interv 2012;5:540-8.
    • (2012) Circ Cardiovasc Interv , vol.5 , pp. 540-548
    • Blanke, P.1    Reinöhl, J.2    Schlensak, C.3
  • 16
    • 84912575565 scopus 로고    scopus 로고
    • Single center TAVR experience with a focus on the prevention and management of catastrophic complications
    • Kapadia SR, Svensson LG, Roselli E, et al. Single center TAVR experience with a focus on the prevention and management of catastrophic complications. Catheter Cardiovasc Interv 2014;84:834-42.
    • (2014) Catheter Cardiovasc Interv , vol.84 , pp. 834-842
    • Kapadia, S.R.1    Svensson, L.G.2    Roselli, E.3
  • 17
    • 0025354576 scopus 로고
    • Tolerance of normal aorta to oversized dual balloon valvuloplasty. Observations in a swine model: Technical note
    • Moore JW, Laird JR, White CJ, et al. Tolerance of normal aorta to oversized dual balloon valvuloplasty. Observations in a swine model: technical note. Cardiovasc Intervent Radiol 1990;13:107-10.
    • (1990) Cardiovasc Intervent Radiol , vol.13 , pp. 107-110
    • Moore, J.W.1    Laird, J.R.2    White, C.J.3
  • 18
    • 67649756770 scopus 로고    scopus 로고
    • Unexpected complications of transapical aortic valve implantation
    • Al-Attar N, Ghodbane W, Himbert D, et al. Unexpected complications of transapical aortic valve implantation. Ann Thorac Surg 2009;88:983-8.
    • (2009) Ann Thorac Surg , vol.88 , pp. 983-988
    • Al-Attar, N.1    Ghodbane, W.2    Himbert, D.3
  • 19
    • 72749119708 scopus 로고    scopus 로고
    • Unexpected left ventricular free-wall rupture following an aortic catheter-valve implantation
    • Ferrari E, Rizzo E, Sulzer C, von Segesser LK. Unexpected left ventricular free-wall rupture following an aortic catheter-valve implantation. Eur J Cardiothorac Surg 2010;37:242-4.
    • (2010) Eur J Cardiothorac Surg , vol.37 , pp. 242-244
    • Ferrari, E.1    Rizzo, E.2    Sulzer, C.3    Von Segesser, L.K.4
  • 20
    • 84855723717 scopus 로고    scopus 로고
    • Contained aortic root rupture after transcatheter aortic valve implantation
    • Himbert D, Brochet E, Serfaty JM, Vahanian A. Contained aortic root rupture after transcatheter aortic valve implantation. Eur Heart J 2010;31:2995.
    • (2010) Eur Heart J , vol.31 , pp. 2995
    • Himbert, D.1    Brochet, E.2    Serfaty, J.M.3    Vahanian, A.4
  • 21
    • 84940789269 scopus 로고    scopus 로고
    • Successful repair of aortic annulus rupture during transcatheter aortic valve replacement using extracorporeal membrane oxygenation support
    • Aug 30 [E-pub ahead of print]
    • Negi SI, Patel J, Patel M, Loyalka P, Kar B, Gregoric I. Successful repair of aortic annulus rupture during transcatheter aortic valve replacement using extracorporeal membrane oxygenation support. Gen Thorac Cardiovasc Surg 2013 Aug 30 [E-pub ahead of print].
    • (2013) Gen Thorac Cardiovasc Surg
    • Negi, S.I.1    Patel, J.2    Patel, M.3    Loyalka, P.4    Kar, B.5    Gregoric, I.6
  • 22
    • 85027954400 scopus 로고    scopus 로고
    • Late contained aortic root rupture and ventricular septal defect after transcatheter aortic valve implantation
    • Aminian A, Lalmand J, Dolatabadi D. Late contained aortic root rupture and ventricular septal defect after transcatheter aortic valve implantation. Catheter Cardiovasc Interv 2013;81:E72-5.
    • (2013) Catheter Cardiovasc Interv , vol.81 , pp. E72-E75
    • Aminian, A.1    Lalmand, J.2    Dolatabadi, D.3
  • 23
    • 79958019713 scopus 로고    scopus 로고
    • A second prosthesis as a procedural rescue option in trans-apical aortic valve implantation
    • Kempfert J, Rastan AJ, Schuler G, et al. A second prosthesis as a procedural rescue option in trans-apical aortic valve implantation. Eur J Cardiothorac Surg 2011;40:56-60.
    • (2011) Eur J Cardiothorac Surg , vol.40 , pp. 56-60
    • Kempfert, J.1    Rastan, A.J.2    Schuler, G.3
  • 24
    • 84904466828 scopus 로고    scopus 로고
    • Successful treatment of aortic root rupture following transcatheter aortic valve implantation in a heavily calcified aorta: A novel approach to a serious complication
    • Lee L, Henderson R, Baig K. Successful treatment of aortic root rupture following transcatheter aortic valve implantation in a heavily calcified aorta: a novel approach to a serious complication. Catheter Cardiovasc Interv 2014;84:303-5.
    • (2014) Catheter Cardiovasc Interv , vol.84 , pp. 303-305
    • Lee, L.1    Henderson, R.2    Baig, K.3
  • 25
    • 84890565951 scopus 로고    scopus 로고
    • Left main occlusion secondary to aortic valve rupture following transcatheter aortic valve replacement managed by left main stenting
    • Kim RJ, McGehee E, Mack MJ. Left main occlusion secondary to aortic valve rupture following transcatheter aortic valve replacement managed by left main stenting. Catheter Cardiovasc Interv 2014;83:E146-9.
    • (2014) Catheter Cardiovasc Interv , vol.83 , pp. E146-E149
    • Kim, R.J.1    McGehee, E.2    Mack, M.J.3
  • 26
    • 84859443388 scopus 로고    scopus 로고
    • Periaortic hematoma after transcatheter aortic valve replacement. Description of a new complication
    • Généreux P, Reiss GR, Kodali SK, et al. Periaortic hematoma after transcatheter aortic valve replacement. Description of a new complication. Catheter Cardiovasc Interv 2012;79:766-76.
    • (2012) Catheter Cardiovasc Interv , vol.79 , pp. 766-776
    • Généreux, P.1    Reiss, G.R.2    Kodali, S.K.3
  • 27
    • 84863839560 scopus 로고    scopus 로고
    • Aortic annular rupture during transcatheter aortic valve implantation: Safe aortic root replacement
    • Eker A, Sozzi FB, Civala F, Bourlon F. Aortic annular rupture during transcatheter aortic valve implantation: safe aortic root replacement. Eur J Cardiothorac Surg 2012;41:1205.
    • (2012) Eur J Cardiothorac Surg , vol.41 , pp. 1205
    • Eker, A.1    Sozzi, F.B.2    Civala, F.3    Bourlon, F.4
  • 28
    • 84880614039 scopus 로고    scopus 로고
    • The impact of integration of a multidetector computed tomography annulus area sizing algorithm of transcatheter aortic valve replacement: A prospective, multicenter, controlled trial
    • Binder RK, Webb JG, Wilson AB, et al. The impact of integration of a multidetector computed tomography annulus area sizing algorithm of transcatheter aortic valve replacement: a prospective, multicenter, controlled trial. J Am Coll Cardiol 2013;62:431-8.
    • (2013) J Am Coll Cardiol , vol.62 , pp. 431-438
    • Binder, R.K.1    Webb, J.G.2    Wilson, A.B.3
  • 29
    • 84882434702 scopus 로고    scopus 로고
    • Valve-in-valve implantation for aortic annular rupture complicating transcatheter aortic valve replacement
    • Yu Y, Vallely M, Ng MKC. Valve-in-valve implantation for aortic annular rupture complicating transcatheter aortic valve replacement. J Invasive Cardiol 2013;25:409-10.
    • (2013) J Invasive Cardiol , vol.25 , pp. 409-410
    • Yu, Y.1    Vallely, M.2    Ng, M.K.C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.