메뉴 건너뛰기




Volumn 63, Issue 9, 2015, Pages 514-517

Successful repair of aortic annulus rupture during transcatheter aortic valve replacement using extracorporeal membrane oxygenation support

Author keywords

Aortic annular rupture; Coronary bypass grafting; Extracorporeal membrane oxygenation; Transcatheter aortic valve

Indexed keywords

AGED; AORTA RUPTURE; AORTA STENOSIS; AORTIC ANNULUS RUPTURE; AORTIC VALVE REPAIR; ARTICLE; ASCENDING AORTA; BALLOON VALVULOPLASTY CATHETER; CASE REPORT; EMERGENCY SURGERY; EXTRACORPOREAL MEMBRANE OXYGENATION DEVICE; EXTRACORPOREAL OXYGENATION; FEMALE; HEART ARREST; HEART LEFT VENTRICLE EJECTION FRACTION; HEART LEFT VENTRICLE HYPERTROPHY; HEART REHABILITATION; HEART TAMPONADE; HOSPITAL DISCHARGE; HUMAN; LEFT CORONARY ARTERY; PARAVALVULAR LEAK; PERCUTANEOUS AORTIC VALVE; PERICARDIOTOMY; POSTOPERATIVE COMPLICATION; PRESSURE GRADIENT; PULSE PRESSURE; RESUSCITATION; RIGHT CORONARY ARTERY; STERNOTOMY; TRANSCATHETER AORTIC VALVE IMPLANTATION; TRANSESOPHAGEAL ECHOCARDIOGRAPHY; TRANSTHORACIC ECHOCARDIOGRAPHY; VERY ELDERLY; ADVERSE EFFECTS; AORTA VALVE; AORTIC VALVE STENOSIS; CARDIAC TAMPONADE; COMPUTER ASSISTED TOMOGRAPHY; HEART RUPTURE; INJURIES; PROCEDURES;

EID: 84940789269     PISSN: 18636705     EISSN: 18636713     Source Type: Journal    
DOI: 10.1007/s11748-013-0312-7     Document Type: Article
Times cited : (8)

References (9)
  • 1
    • 80053949735 scopus 로고    scopus 로고
    • Incidence and treatment of procedural cardiovascular complications associated with trans-arterial and trans-apical interventional aortic valve implantation in 412 consecutive patients
    • PID: 21515069
    • Lange R, Bleiziffer S, Piazza N, Mazzitelli D, Hutter A, Tassani-Prell P, et al. Incidence and treatment of procedural cardiovascular complications associated with trans-arterial and trans-apical interventional aortic valve implantation in 412 consecutive patients. Eur J Cardiothorac Surg. 2011;40(5):1105–13.
    • (2011) Eur J Cardiothorac Surg , vol.40 , Issue.5 , pp. 1105-1113
    • Lange, R.1    Bleiziffer, S.2    Piazza, N.3    Mazzitelli, D.4    Hutter, A.5    Tassani-Prell, P.6
  • 2
    • 84857552892 scopus 로고    scopus 로고
    • True percutaneous approach for transfemoral aortic valve implantation using the Prostar XL device: impact of learning curve on vascular complications
    • PID: 22361606
    • Hayashida K, Lefèvre T, Chevalier B, Hovasse T, Romano M, Garot P, et al. True percutaneous approach for transfemoral aortic valve implantation using the Prostar XL device: impact of learning curve on vascular complications. JACC Cardiovasc Interv. 2012;5(2):207–14.
    • (2012) JACC Cardiovasc Interv , vol.5 , Issue.2 , pp. 207-214
    • Hayashida, K.1    Lefèvre, T.2    Chevalier, B.3    Hovasse, T.4    Romano, M.5    Garot, P.6
  • 3
    • 70349196461 scopus 로고    scopus 로고
    • Transcatheter aortic valve implantation: review of the nature, management, and avoidance of procedural complications
    • PID: 19778768
    • Masson JB, Kovac J, Schuler G, Yen J, Cheung A, Kapadia S, et al. Transcatheter aortic valve implantation: review of the nature, management, and avoidance of procedural complications. JACC Cardiovasc Interv. 2009;2(9):811–20.
    • (2009) JACC Cardiovasc Interv , vol.2 , Issue.9 , pp. 811-820
    • Masson, J.B.1    Kovac, J.2    Schuler, G.3    Yen, J.4    Cheung, A.5    Kapadia, S.6
  • 4
    • 78651337155 scopus 로고    scopus 로고
    • Standardized endpoint definitions for transcatheter aortic valve implantation clinical trials: a consensus report from the valve academic research consortium
    • PID: 21216553
    • Leon MB, Piazza N, Nikolsky E, Blackstone EH, Cutlip DE, Kappetein AP, et al. Standardized endpoint definitions for transcatheter aortic valve implantation clinical trials: a consensus report from the valve academic research consortium. J Am Coll Cardiol. 2011;57:253–69.
    • (2011) J Am Coll Cardiol , vol.57 , pp. 253-269
    • Leon, M.B.1    Piazza, N.2    Nikolsky, E.3    Blackstone, E.H.4    Cutlip, D.E.5    Kappetein, A.P.6
  • 5
    • 78651489907 scopus 로고    scopus 로고
    • Standardized endpoint definitions for transcatheter aortic valve implantation clinical trials: a consensus report from the valve academic research consortium
    • PID: 21216739
    • Leon MB, Piazza N, Nikolsky E, Blackstone EH, Cutlip DE, Kappetein AP, et al. Standardized endpoint definitions for transcatheter aortic valve implantation clinical trials: a consensus report from the valve academic research consortium. Eur Heart J. 2011;32:205–17.
    • (2011) Eur Heart J , vol.32 , pp. 205-217
    • Leon, M.B.1    Piazza, N.2    Nikolsky, E.3    Blackstone, E.H.4    Cutlip, D.E.5    Kappetein, A.P.6
  • 6
    • 84855403379 scopus 로고    scopus 로고
    • Percutaneous aortic valve replacement. Vascular outcomes with a fully percutaneous procedure
    • PID: 22222073
    • Toggweiler S, Gurvitch R, Leipsic J, Wood D, Willson AB, Binder R, et al. Percutaneous aortic valve replacement. Vascular outcomes with a fully percutaneous procedure. J Am Coll Cardiol. 2012;59:113–8.
    • (2012) J Am Coll Cardiol , vol.59 , pp. 113-118
    • Toggweiler, S.1    Gurvitch, R.2    Leipsic, J.3    Wood, D.4    Willson, A.B.5    Binder, R.6
  • 7
    • 73649096192 scopus 로고    scopus 로고
    • Multimodal assessment of the aortic annulus diameter: implications for transcatheter aortic valve implantation
    • PID: 20117398
    • Messika-Zeitoun D, Serfaty JM, Brochet E, Ducrocq G, Lepage L, Detaint D, et al. Multimodal assessment of the aortic annulus diameter: implications for transcatheter aortic valve implantation. J Am Coll Cardiol. 2010;55:186–94.
    • (2010) J Am Coll Cardiol , vol.55 , pp. 186-194
    • Messika-Zeitoun, D.1    Serfaty, J.M.2    Brochet, E.3    Ducrocq, G.4    Lepage, L.5    Detaint, D.6
  • 8
    • 0024440014 scopus 로고
    • Palliative percutaneous aortic balloon valvuloplasty before noncardiac operations and invasive diagnostic procedures
    • PID: 2475727, COI: 1:STN:280:DyaL1MzmtlGktg%3D%3D
    • Hayes SN, Holmes DR Jr, Nishimura RA, Reeder GS. Palliative percutaneous aortic balloon valvuloplasty before noncardiac operations and invasive diagnostic procedures. Mayo Clin Proc. 1989;64:753–7.
    • (1989) Mayo Clin Proc , vol.64 , pp. 753-757
    • Hayes, S.N.1    Holmes, D.R.2    Nishimura, R.A.3    Reeder, G.S.4
  • 9
    • 84886948052 scopus 로고    scopus 로고
    • Potential mechanism for annulus rupture in transcatheter aortic valve implantation
    • Hayashida K, Bouvier E, Lefevre T, et al
    • Hayashida K, Bouvier E, Lefevre T, et al. Potential mechanism for annulus rupture in transcatheter aortic valve implantation. Catheter Cardiovasc Interv 2012 (E-pub ahead of print).
    • Catheter Cardiovasc Interv 2012 (E-pub ahead of print)


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.