Indexed keywords
ADOLESCENT;
ADULT;
ADULT DISEASE;
ARTICLE;
ARTIFICIAL HEART PACEMAKER;
BIPOLAR LUMENLESS PACEMAKER ELECTRODE;
CHILD;
CHILDHOOD DISEASE;
CLINICAL ARTICLE;
EQUIPMENT DESIGN;
FEMALE;
FLUOROSCOPY;
GREAT VESSELS TRANSPOSITION;
HEART ATRIUM PACING;
HEART CATHETER;
HEART VENTRICLE PACING;
HEART VENTRICLE SEPTUM DEFECT;
HUMAN;
MALE;
OUTCOME ASSESSMENT;
PACEMAKER ELECTRODE;
PERFORMANCE;
PRESCHOOL CHILD;
PRIORITY JOURNAL;
RETROSPECTIVE STUDY;
SCHOOL CHILD;
THORAX RADIOGRAPHY;
TREATMENT INDICATION;
UNITED STATES;
ADULT;
ARRHYTHMIAS, CARDIAC;
CHILD;
CHILD, PRESCHOOL;
DEATH, SUDDEN, CARDIAC;
ELECTRODES, IMPLANTED;
FEMALE;
HEART CATHETERIZATION;
HEART DEFECTS, CONGENITAL;
HUMANS;
INFANT;
MALE;
PACEMAKER, ARTIFICIAL;
POSTOPERATIVE COMPLICATIONS;
YOUNG ADULT;
1
33750970326
Pacemakers and implantable cardioverter-defibrillators in pediatric patients
Silka MJ, Bar-Cohen Y. Pacemakers and implantable cardioverter-defibrillators in pediatric patients. Heart Rhythm 2006, 3:1360-1366.
(2006)
Heart Rhythm
, vol.3
, pp. 1360-1366
Silka, M.J.1
Bar-Cohen, Y.2
2
77954367815
Pediatric pacing and defibrillation usage
Ellengoben KA, Wilkoff B, Kay GN, Pak Lau C. eds., 3rd, edn., Philadelphia, Pa, Saunders Elsevier Publishing Co., Inc
Serwer GA, Leory SS. Pediatric pacing and defibrillation usage. Clinical Cardiac Pacing, Defibrillation and Resynchronization Therapy 2007, 1177-1216. Ellengoben KA, Wilkoff BKay GNPak Lau C. eds., 3rd, edn., Philadelphia, Pa, Saunders Elsevier Publishing Co., Inc
(2007)
Clinical Cardiac Pacing, Defibrillation and Resynchronization Therapy
, pp. 1177-1216
Serwer, G.A.1
Leory, S.S.2
3
0035122781
Grown-up congenital heart disease-medical demands look back, look forward 2000
Somerville J. Grown-up congenital heart disease-medical demands look back, look forward 2000. Thorac Cardiovasc Surg 2001, 49:21-26.
(2001)
Thorac Cardiovasc Surg
, vol.49
, pp. 21-26
Somerville, J.1
5
0033545631
Pacemaker leads: performance and progress
de Voogt WG. Pacemaker leads: performance and progress. Am J Cardiol 1999, 83:187D-191D.
(1999)
Am J Cardiol
, vol.83
de Voogt, W.G.1
6
34250726688
Implantation of SelectSecure leads in children
Tuzcu V. Implantation of SelectSecure leads in children. Pacing Clin Electrophysiol 2007, 30:831-833.
(2007)
Pacing Clin Electrophysiol
, vol.30
, pp. 831-833
Tuzcu, V.1
7
77954353931
Bipolar lumenless lead performance characteristics in children and adults with congenital heart disease
Daccarett M, Segerson NM, Abedin M. Bipolar lumenless lead performance characteristics in children and adults with congenital heart disease. Heart Rhythm 2007, 4:AB20-AB21.
(2007)
Heart Rhythm
, vol.4
Daccarett, M.1
Segerson, N.M.2
Abedin, M.3
8
33747116031
Multi-center clinical experience with a lumenless, catheter-delivered, bipolar, permanent pacemaker lead: implant safety and electrical performance
Gammage MD, Lieberman RA, Yee R. Multi-center clinical experience with a lumenless, catheter-delivered, bipolar, permanent pacemaker lead: implant safety and electrical performance. Pacing Clin Electrophysiol 2006, 29:858-865.
(2006)
Pacing Clin Electrophysiol
, vol.29
, pp. 858-865
Gammage, M.D.1
Lieberman, R.A.2
Yee, R.3
10
0034176211
Twenty years experience with pediatric pacing: epicardial and transvenous stimulation
Sachweh JS, Vazquez-Jimenez JF, Schondube FA. Twenty years experience with pediatric pacing: epicardial and transvenous stimulation. Eur J Cardiothorac Surg 2000, 17:455-461.
(2000)
Eur J Cardiothorac Surg
, vol.17
, pp. 455-461
Sachweh, J.S.1
Vazquez-Jimenez, J.F.2
Schondube, F.A.3
11
36649018950
Current of injury predicts acute performance of catheter-delivered active fixation pacing leads
Redfearn DP, Gula LJ, Krahn AD. Current of injury predicts acute performance of catheter-delivered active fixation pacing leads. Pacing Clin Electrophysiol 2007, 30:1438-1444.
(2007)
Pacing Clin Electrophysiol
, vol.30
, pp. 1438-1444
Redfearn, D.P.1
Gula, L.J.2
Krahn, A.D.3
12
34249796636
Alternate site atrial pacing in the young: conventional echocardiography and tissue Doppler analysis of the effects on atrial function and ventricular filling
Zilberman MV, Karpawich PP. Alternate site atrial pacing in the young: conventional echocardiography and tissue Doppler analysis of the effects on atrial function and ventricular filling. Pacing Clin Electrophysiol 2007, 30:755-760.
(2007)
Pacing Clin Electrophysiol
, vol.30
, pp. 755-760
Zilberman, M.V.1
Karpawich, P.P.2
13
34250701748
Noncatheter-based delivery of a single-chamber lumenless pacing lead in small children
Kenny D, Walsh KP. Noncatheter-based delivery of a single-chamber lumenless pacing lead in small children. Pacing Clin Electrophysiol 2007, 30:834-838.
(2007)
Pacing Clin Electrophysiol
, vol.30
, pp. 834-838
Kenny, D.1
Walsh, K.P.2