Calibration of blood pressure data after replacement of the standard mercury sphygmomanometer by an oscillometric device and concurrent change of cuffs

Author keywords

Arm circumference; blood pressure; cuff size; measurement; oscillometric

Indexed keywords

ADULT; AGE; ARM CIRCUMFERENCE; ARTICLE; BLOOD PRESSURE CUFF; BLOOD PRESSURE MEASUREMENT; CALIBRATION; CARDIOVASCULAR DIAGNOSTIC DEVICE; CARDIOVASCULAR PARAMETERS; COMPARATIVE STUDY; DIASTOLIC BLOOD PRESSURE; FEMALE; HUMAN; MAJOR CLINICAL STUDY; MALE; MEAN ARTERIAL PRESSURE; MERCURY SPHYGMOMANOMETER; OSCILLOMETRIC BLOOD PRESSURE MEASUREMENT DEVICE; PRIORITY JOURNAL; PULSE PRESSURE; SEX; SYSTOLIC BLOOD PRESSURE; VALIDATION STUDY; BLOOD PRESSURE; BLOOD PRESSURE MONITOR; DEVICES; HEALTH SURVEY; MIDDLE AGED; OSCILLOMETRY; PHYSIOLOGY; PROCEDURES; SPHYGMOMANOMETER; STANDARDS; STATISTICAL MODEL; YOUNG ADULT;

EID: 84920775630     PISSN: 13595237     EISSN: 14735725     Source Type: Journal    
DOI: 10.1097/MBP.0000000000000081     Document Type: Article
Times cited : (13)

References (11)
  • 1
    • 0037079309 scopus 로고    scopus 로고
    • Age-specific relevance of usual blood pressure to vascular mortality: A meta-analysis of individual data for one million adults in 61 prospective studies
    • Lewington S, Clarke R, Qizilbash N, Peto R, Collins R. Prospective Studies Collaboration. Age-specific relevance of usual blood pressure to vascular mortality: a meta-analysis of individual data for one million adults in 61 prospective studies. Lancet 2002; 360:1903-1913.
    • (2002) Lancet , vol.360 , pp. 1903-1913
    • Lewington, S.1    Clarke, R.2    Qizilbash, N.3    Peto, R.4    Collins, R.5
  • 2
    • 84878577170 scopus 로고    scopus 로고
    • Blood pressure in Germany 2008-2011: Results of the German Health Interview and Examination Survey for Adults (DEGS1)
    • Neuhauser H, Thamm M, Ellert U. Blood pressure in Germany 2008-2011: results of the German Health Interview and Examination Survey for Adults (DEGS1). Bundesgesundheitsblatt Gesundheitsforschung Gesundheitsschutz 2013; 56:795-801.
    • (2013) Bundesgesundheitsblatt Gesundheitsforschung Gesundheitsschutz , vol.56 , pp. 795-801
    • Neuhauser, H.1    Thamm, M.2    Ellert, U.3
  • 3
    • 76449087188 scopus 로고    scopus 로고
    • European Society of Hypertension International Protocol revision 2010 for the validation of blood pressure measuring devices in adults
    • O'Brien E, Atkins N, Stergiou G, Karpettas N, Parati G, Asmar R, et al. Working Group on Blood Pressure Monitoring of the European Society of Hypertension. European Society of Hypertension International Protocol revision 2010 for the validation of blood pressure measuring devices in adults. Blood Press Monit 2010; 15:23-38.
    • (2010) Blood Press Monit , vol.15 , pp. 23-38
    • O'Brien, E.1    Atkins, N.2    Stergiou, G.3    Karpettas, N.4    Parati, G.5    Asmar, R.6
  • 4
    • 0030850885 scopus 로고    scopus 로고
    • Evaluation of the Datascope Accutorr Plus according to the recommendations of the Association for the Advancement of Medical Instrumentation
    • Anwar YA, Tendler BE, McCabe EJ, Mansoor GA, White WB. Evaluation of the Datascope Accutorr Plus according to the recommendations of the Association for the Advancement of Medical Instrumentation. Blood Press Monit 1997; 2:105-110.
    • (1997) Blood Press Monit , vol.2 , pp. 105-110
    • Anwar, Y.A.1    Tendler, B.E.2    McCabe, E.J.3    Mansoor, G.A.4    White, W.B.5
  • 5
    • 0041381270 scopus 로고    scopus 로고
    • Clinical evaluation of the trimline blood pressure cuffs with the Accutorr Plus Monitor
    • White WB, Herbst T, Thavarajah S, Giacco S. Clinical evaluation of the trimline blood pressure cuffs with the Accutorr Plus Monitor. Blood Press Monit 2003; 8:137-140.
    • (2003) Blood Press Monit , vol.8 , pp. 137-140
    • White, W.B.1    Herbst, T.2    Thavarajah, S.3    Giacco, S.4
  • 6
    • 0035799041 scopus 로고    scopus 로고
    • Blood pressure measuring devices: Recommendations of the European Society of Hypertension
    • O'Brien E, Waeber B, Parati G, Staessen J, Myers MG. Blood pressure measuring devices: recommendations of the European Society of Hypertension. BMJ 2001; 322:531-536.
    • (2001) BMJ , vol.322 , pp. 531-536
    • O'Brien, E.1    Waeber, B.2    Parati, G.3    Staessen, J.4    Myers, M.G.5
  • 7
    • 77949391742 scopus 로고    scopus 로고
    • Assessing the validity of the Omron HEM-907XL oscillometric blood pressure measurement device in a National Survey environment
    • Ostchega Y, Nwankwo T, Sorlie PD, Wolz M, Zipf G. Assessing the validity of the Omron HEM-907XL oscillometric blood pressure measurement device in a National Survey environment. J Clin Hypertens (Greenwich) 2010; 12:22-28.
    • (2010) J Clin Hypertens (Greenwich) , vol.12 , pp. 22-28
    • Ostchega, Y.1    Nwankwo, T.2    Sorlie, P.D.3    Wolz, M.4    Zipf, G.5
  • 8
    • 0033770477 scopus 로고    scopus 로고
    • Arterial stiffness as underlying mechanism of disagreement between an oscillometric blood pressure monitor and a sphygmomanometer
    • Van Popele NM, Bos WJ, de Beer NA, van Der Kuip DA, Hofman A, Grobbee DE, Witteman JC. Arterial stiffness as underlying mechanism of disagreement between an oscillometric blood pressure monitor and a sphygmomanometer. Hypertension 2000; 36:484-488.
    • (2000) Hypertension , vol.36 , pp. 484-488
    • Van Popele, N.M.1    Bos, W.J.2    De Beer, N.A.3    Van Der Kuip, D.A.4    Hofman, A.5    Grobbee, D.E.6    Witteman, J.C.7
  • 9
    • 33745347953 scopus 로고    scopus 로고
    • Heinz Nixdorf Recall Study Investigative Group. Algorithms for converting random-zero to automated oscillometric blood pressure values, and vice versa
    • Stang A, Moebus S, Mohlenkamp S, Dragano N, Schmermund A, Beck EM, et al. Heinz Nixdorf Recall Study Investigative Group. Algorithms for converting random-zero to automated oscillometric blood pressure values, and vice versa. Am J Epidemiol 2006; 164:85-94.
    • (2006) Am J Epidemiol , vol.164 , pp. 85-94
    • Stang, A.1    Moebus, S.2    Mohlenkamp, S.3    Dragano, N.4    Schmermund, A.5    Beck, E.M.6
  • 10
    • 84863818749 scopus 로고    scopus 로고
    • Comparison of blood pressure measurements between an automated oscillometric device and a Hawksley random-zero sphygmomanometer in the northern Sweden MONICA study
    • Eriksson M, Carlberg B, Jansson JH. Comparison of blood pressure measurements between an automated oscillometric device and a Hawksley random-zero sphygmomanometer in the northern Sweden MONICA study. Blood Press Monit 2012; 17:164-170.
    • (2012) Blood Press Monit , vol.17 , pp. 164-170
    • Eriksson, M.1    Carlberg, B.2    Jansson, J.H.3
  • 11
    • 40049101680 scopus 로고    scopus 로고
    • Comparison between an automated and manual sphygmomanometer in a population survey
    • Myers MG, McInnis NH, Fodor GJ, Leenen FH. Comparison between an automated and manual sphygmomanometer in a population survey. Am J Hypertens 2008; 21:280-283.
    • (2008) Am J Hypertens , vol.21 , pp. 280-283
    • Myers, M.G.1    McInnis, N.H.2    Fodor, G.J.3    Leenen, F.H.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.