메뉴 건너뛰기




Volumn 73, Issue 1, 2015, Pages 292-298

High-resolution respiratory self-gated golden angle cardiac MRI: Comparison of self-gating Methods in combination with k-T SPARSE SENSE

Author keywords

Cardiac MRI; Golden angle radial acquisition; Respiratory motion; Self gating

Indexed keywords

HEART; IMAGE ENHANCEMENT;

EID: 84919840187     PISSN: 07403194     EISSN: 15222594     Source Type: Journal    
DOI: 10.1002/mrm.25102     Document Type: Article
Times cited : (47)

References (30)
  • 1
    • 0035156783 scopus 로고    scopus 로고
    • Navigator echoes in cardiac magnetic resonance
    • Firmin D, Keegan J. Navigator echoes in cardiac magnetic resonance. J Cardiovasc Magn Reson 2001;3:183-193.
    • (2001) J Cardiovasc Magn Reson , vol.3 , pp. 183-193
    • Firmin, D.1    Keegan, J.2
  • 2
    • 33645771143 scopus 로고    scopus 로고
    • Navigator gated high temporal resolution tissue phase mapping of myocardial motion
    • Jung B, Zaitsev M, Hennig J, Markl M. Navigator gated high temporal resolution tissue phase mapping of myocardial motion. Magn Reson Med 2006;55:937-942.
    • (2006) Magn Reson Med , vol.55 , pp. 937-942
    • Jung, B.1    Zaitsev, M.2    Hennig, J.3    Markl, M.4
  • 3
    • 51449086858 scopus 로고    scopus 로고
    • 2D free-breathing dual navigator-gated cardiac function validated against the 2D breath-hold acquisition
    • Peters DC, Nezafat R, Eggers H, Stehning C, Manning WJ. 2D free-breathing dual navigator-gated cardiac function validated against the 2D breath-hold acquisition. J Magn Reson Imaging 2008;28:773-777.
    • (2008) J Magn Reson Imaging , vol.28 , pp. 773-777
    • Peters, D.C.1    Nezafat, R.2    Eggers, H.3    Stehning, C.4    Manning, W.J.5
  • 6
    • 84867708182 scopus 로고    scopus 로고
    • K-t radial SPARSE-SENSE: Combination of compressed sensing and parallel imaging with golden angle radial sampling for highly accelerated volumetric dynamic MRI
    • Melbourne, Australia
    • Feng L, Chandarana H, Xu J, Block KT, Sodickson D, Otazo R. K-t radial SPARSE-SENSE: combination of compressed sensing and parallel imaging with golden angle radial sampling for highly accelerated volumetric dynamic MRI. In Proceedings of the 20th Annual Meeting of ISMRM, Melbourne, Australia, 2012. p. 81.
    • (2012) Proceedings of the 20th Annual Meeting of ISMRM , pp. 81
    • Feng, L.1    Chandarana, H.2    Xu, J.3    Block, K.T.4    Sodickson, D.5    Otazo, R.6
  • 10
    • 32544435924 scopus 로고    scopus 로고
    • Generalized self-navigated motion detection technique: Preliminary investigation in abdominal imaging
    • Brau ACS, Brittain JH. Generalized self-navigated motion detection technique: Preliminary investigation in abdominal imaging. Magn Reson Med 2006;55:263-270.
    • (2006) Magn Reson Med , vol.55 , pp. 263-270
    • Brau, A.C.S.1    Brittain, J.H.2
  • 11
    • 51449123206 scopus 로고    scopus 로고
    • Prospective self-gating for simultaneous compensation of cardiac and respiratory motion
    • Buehrer M, Curcic J, Boesiger P, Kozerke S. Prospective self-gating for simultaneous compensation of cardiac and respiratory motion. Magn Reson Med 2008;60:683-690.
    • (2008) Magn Reson Med , vol.60 , pp. 683-690
    • Buehrer, M.1    Curcic, J.2    Boesiger, P.3    Kozerke, S.4
  • 13
    • 77952852611 scopus 로고    scopus 로고
    • Performance of simultaneous cardiac-respiratory self-gated three-dimensional MR imaging of the heart: Initial experience
    • Manka R, Buehrer M, Boesiger P, Fleck E, Kozerke S. Performance of simultaneous cardiac-respiratory self-gated three-dimensional MR imaging of the heart: initial experience. Radiology 2010;255:909-916.
    • (2010) Radiology , vol.255 , pp. 909-916
    • Manka, R.1    Buehrer, M.2    Boesiger, P.3    Fleck, E.4    Kozerke, S.5
  • 14
    • 0025228409 scopus 로고
    • Extraction of cardiac and respiratory motion cycles by use of projection data and its applications to NMR imaging
    • Kim WS, Mun CW, Kim DJ, Cho ZH. Extraction of cardiac and respiratory motion cycles by use of projection data and its applications to NMR imaging. Magn Reson Med 1990;13:25-37.
    • (1990) Magn Reson Med , vol.13 , pp. 25-37
    • Kim, W.S.1    Mun, C.W.2    Kim, D.J.3    Cho, Z.H.4
  • 15
    • 0025696493 scopus 로고
    • Wireless retrospective gating: Application to cine cardiac imaging
    • Spraggins TA. Wireless retrospective gating: application to cine cardiac imaging. Magn Reson Imaging 1990;8:675-681.
    • (1990) Magn Reson Imaging , vol.8 , pp. 675-681
    • Spraggins, T.A.1
  • 17
    • 51449110126 scopus 로고    scopus 로고
    • A dual-projection respiratory self-gating technique for whole-heart coronary MRA
    • Lai P, Larson AC, Bi X, Jerecic R, Li D. A dual-projection respiratory self-gating technique for whole-heart coronary MRA. J Magn Reson Imaging 2008;28:612-620.
    • (2008) J Magn Reson Imaging , vol.28 , pp. 612-620
    • Lai, P.1    Larson, A.C.2    Bi, X.3    Jerecic, R.4    Li, D.5
  • 18
    • 22744432670 scopus 로고    scopus 로고
    • Free-breathing whole-heart coronary MRA with 3D radial SSFP and self-navigated image reconstruction
    • Stehning C, Börnert P, Nehrke K, Eggers H, Stuber M. Free-breathing whole-heart coronary MRA with 3D radial SSFP and self-navigated image reconstruction. Magn Reson Med 2005;54:476-480.
    • (2005) Magn Reson Med , vol.54 , pp. 476-480
    • Stehning, C.1    Börnert, P.2    Nehrke, K.3    Eggers, H.4    Stuber, M.5
  • 19
    • 77955293409 scopus 로고    scopus 로고
    • Respiratory and cardiac self-gated free-breathing cardiac CINE imaging with multiecho 3D hybrid radial SSFP acquisition
    • Liu J, Spincemaille P, Codella NCF, Nguyen TD, Prince MR, Wang Y. Respiratory and cardiac self-gated free-breathing cardiac CINE imaging with multiecho 3D hybrid radial SSFP acquisition. Magn Reson Med 2010;63:1230-1237.
    • (2010) Magn Reson Med , vol.63 , pp. 1230-1237
    • Liu, J.1    Spincemaille, P.2    Codella, N.C.F.3    Nguyen, T.D.4    Prince, M.R.5    Wang, Y.6
  • 20
    • 70349625820 scopus 로고    scopus 로고
    • Four-dimensional (4D) flow of the whole heart and great vessels using real-time respiratory self-gating
    • Uribe S, Beerbaum P, Sérensen TS, Rasmusson A, Razavi R, Schaeffter T. Four-dimensional (4D) flow of the whole heart and great vessels using real-time respiratory self-gating. Magn Reson Med 2009;62:984-992.
    • (2009) Magn Reson Med , vol.62 , pp. 984-992
    • Uribe, S.1    Beerbaum, P.2    Sérensen, T.S.3    Rasmusson, A.4    Razavi, R.5    Schaeffter, T.6
  • 21
    • 79959621699 scopus 로고    scopus 로고
    • New respiratory gating technique for whole heart cine imaging: Integration of a navigator slice in steady state free precession sequences
    • Uribe S, Tejos C, Razavi R, Schaeffter T. New respiratory gating technique for whole heart cine imaging: integration of a navigator slice in steady state free precession sequences. J Magn Reson Imaging 2011;34:211-219.
    • (2011) J Magn Reson Imaging , vol.34 , pp. 211-219
    • Uribe, S.1    Tejos, C.2    Razavi, R.3    Schaeffter, T.4
  • 23
    • 79959191462 scopus 로고    scopus 로고
    • Z intensityweighted position self-respiratory gating method for free-breathing 3D cardiac CINE imaging
    • Spincemaille P, Liu J, Nguyen T, Prince MR, Wang Y. Z intensityweighted position self-respiratory gating method for free-breathing 3D cardiac CINE imaging. Magn Reson Imaging 2011;29:861-868.
    • (2011) Magn Reson Imaging , vol.29 , pp. 861-868
    • Spincemaille, P.1    Liu, J.2    Nguyen, T.3    Prince, M.R.4    Wang, Y.5
  • 25
    • 84865478167 scopus 로고    scopus 로고
    • Retrospective reconstruction of high temporal resolution cine images from real-time MRI using iterative motion correction
    • Hansen MS, Sérensen TS, Arai AE, Kellman P. Retrospective reconstruction of high temporal resolution cine images from real-time MRI using iterative motion correction. Magn Reson Med 2012;68:741-750.
    • (2012) Magn Reson Med , vol.68 , pp. 741-750
    • Hansen, M.S.1    Sérensen, T.S.2    Arai, A.E.3    Kellman, P.4
  • 26
    • 0032866250 scopus 로고    scopus 로고
    • MR Fluoroscopy using projection reconstruction multi-gradient-echo (prMGE) MRI
    • Rasche V, Holz D, Proska R. MR Fluoroscopy using projection reconstruction multi-gradient-echo (prMGE) MRI. Magn Reson Med 1999;42:324-334.
    • (1999) Magn Reson Med , vol.42 , pp. 324-334
    • Rasche, V.1    Holz, D.2    Proska, R.3
  • 27
    • 0018306059 scopus 로고
    • A threshold selection method from gray-level histograms
    • Otsu N. A threshold selection method from gray-level histograms. IEEE Trans Sys, Man, Cyber 1979;9:62-66.
    • (1979) IEEE Trans Sys, Man, Cyber , vol.9 , pp. 62-66
    • Otsu, N.1
  • 30
    • 0033953459 scopus 로고    scopus 로고
    • Image metric-based correction (Autocorrection) of motion effects: Analysis of image metrics
    • McGee KP, Manduca A, Felmlee JP, Riederer SJ, Ehman RL. Image metric-based correction (Autocorrection) of motion effects: analysis of image metrics. J Magn Reson Imaging 2000;11:174-181.
    • (2000) J Magn Reson Imaging , vol.11 , pp. 174-181
    • McGee, K.P.1    Manduca, A.2    Felmlee, J.P.3    Riederer, S.J.4    Ehman, R.L.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.