메뉴 건너뛰기




Volumn 43, Issue 1, 2015, Pages 126-130

Patient specific implants (PSI) in reconstruction of orbital floor and wall fractures

Author keywords

Computer Assisted surgery; Orbital fractures; Patient specific implants (PSI); Reconstruction

Indexed keywords

ADULT; AGED; ARTICLE; BENT TITANIUM MESH IMPLANT; CLINICAL ARTICLE; COMPUTED TOMOGRAPHY SCANNER; COMPUTER ASSISTED TOMOGRAPHY; FEMALE; HUMAN; IMAGE RECONSTRUCTION; IMPLANT; INTRAOPERATIVE PERIOD; MALE; ORBIT FRACTURE; ORBITAL FLOOR FRACTURE; ORBITAL FLOOR IMPLANT; ORBITAL WALL FRACTURE; PATIENT SPECIFIC TITANIUM IMPLANT; POSTOPERATIVE CARE; POSTOPERATIVE PERIOD; PREOPERATIVE PERIOD; REOPERATION; TREATMENT PLANNING; WORKFLOW; ANATOMIC LANDMARK; BIOLOGICAL MODEL; CHEMISTRY; COMPARATIVE STUDY; COMPUTER ASSISTED SURGERY; DEVICES; IMAGE PROCESSING; MIDDLE AGED; ORBITAL FRACTURES; PATIENT CARE PLANNING; PROCEDURES; PROSTHESES AND ORTHOSES; PROSTHESIS DESIGN; RADIOGRAPHY; RECONSTRUCTIVE SURGERY; SURGICAL MESH; THREE DIMENSIONAL IMAGING;

EID: 84919698473     PISSN: 10105182     EISSN: 18784119     Source Type: Journal    
DOI: 10.1016/j.jcms.2014.10.024     Document Type: Article
Times cited : (136)

References (15)
  • 2
    • 80051544007 scopus 로고    scopus 로고
    • Analysis of complications after surgical repair of orbital fractures
    • M. Brucoli, F. Arcuri, R. Cavenaghi, and A. Benech Analysis of complications after surgical repair of orbital fractures J Craniofac Surg 22 2011 1387 1390
    • (2011) J Craniofac Surg , vol.22 , pp. 1387-1390
    • Brucoli, M.1    Arcuri, F.2    Cavenaghi, R.3    Benech, A.4
  • 4
    • 0026428411 scopus 로고
    • A 7-year review of maxillofacial trauma in a central London hospital
    • G. Dimitroulis, and J. Eyre A 7-year review of maxillofacial trauma in a central London hospital Br Dent J 20 1991 300 302
    • (1991) Br Dent J , vol.20 , pp. 300-302
    • Dimitroulis, G.1    Eyre, J.2
  • 5
    • 84879829930 scopus 로고    scopus 로고
    • Precision of posttraumatic primary orbital reconstruction using individually bent titanium mesh with and without navigation: A retrospective study
    • H. Essig, L. Dressel, M. Rana, H. Kokemueller, M. Ruecker, and N.C. Gellrich Precision of posttraumatic primary orbital reconstruction using individually bent titanium mesh with and without navigation: a retrospective study Head Face Med 9 2013 18
    • (2013) Head Face Med , vol.9 , pp. 18
    • Essig, H.1    Dressel, L.2    Rana, M.3    Kokemueller, H.4    Ruecker, M.5    Gellrich, N.C.6
  • 6
    • 11844267224 scopus 로고    scopus 로고
    • Basic research and 12 years of clinical experience in computer-Assisted navigation technology: A review
    • R. Ewers, K. Schicho, G. Undt, F. Wanschitz, M. Truppe, and R. Seemann Basic research and 12 years of clinical experience in computer-Assisted navigation technology: a review Int J Oral Maxillofac Surg 34 2005 1 8
    • (2005) Int J Oral Maxillofac Surg , vol.34 , pp. 1-8
    • Ewers, R.1    Schicho, K.2    Undt, G.3    Wanschitz, F.4    Truppe, M.5    Seemann, R.6
  • 7
    • 84866350615 scopus 로고    scopus 로고
    • Radiologic and facial morphologic long-term results in treatment of orbital floor fracture with flexible absorbable alloplastic material
    • M. Gerressen, S. Gillessen, D. Riediger, F. Hölzle, A. Modabber, and A. Ghassemi Radiologic and facial morphologic long-term results in treatment of orbital floor fracture with flexible absorbable alloplastic material J Oral Maxillofac Surg 70 2012 2375 2385
    • (2012) J Oral Maxillofac Surg , vol.70 , pp. 2375-2385
    • Gerressen, M.1    Gillessen, S.2    Riediger, D.3    Hölzle, F.4    Modabber, A.5    Ghassemi, A.6
  • 9
    • 61549113133 scopus 로고    scopus 로고
    • Dimensional error of selective laser sintering, three-dimensional printing and PolyJet models in the reproduction of mandibular anatomy
    • D. Ibrahim, T.L. Broilo, C. Heitz, M.G. de Oliveira, H.W. de Oliveira, and S.M. Nobre Dimensional error of selective laser sintering, three-dimensional printing and PolyJet models in the reproduction of mandibular anatomy J Craniomaxillofac Surg 37 2009 167 173
    • (2009) J Craniomaxillofac Surg , vol.37 , pp. 167-173
    • Ibrahim, D.1    Broilo, T.L.2    Heitz, C.3    De Oliveira, M.G.4    De Oliveira, H.W.5    Nobre, S.M.6
  • 10
    • 84886389467 scopus 로고    scopus 로고
    • Comparison of pre-bent titanium mesh versus polyethylene implants in patient specific orbital reconstructions
    • M. Kozakiewicz, and P. Szymor Comparison of pre-bent titanium mesh versus polyethylene implants in patient specific orbital reconstructions Head Face Med 29 2013 32
    • (2013) Head Face Med , vol.29 , pp. 32
    • Kozakiewicz, M.1    Szymor, P.2
  • 14
    • 84880117949 scopus 로고    scopus 로고
    • An analysis of pure blowout fractures and associated ocular symptoms
    • J.W. Shin, J.S. Lim, G. Yoo, and J.H. Byeon An analysis of pure blowout fractures and associated ocular symptoms J Craniofac Surg 24 2013 703 707
    • (2013) J Craniofac Surg , vol.24 , pp. 703-707
    • Shin, J.W.1    Lim, J.S.2    Yoo, G.3    Byeon, J.H.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.