메뉴 건너뛰기




Volumn 23, Issue 1, 2015, Pages 117-125

Coronary MR Angiography Revealed. How to Optimize Image Quality.

Author keywords

Cardiac gating; Coronary artery disease; Coronary magnetic resonance angiography; Gadolinium contrast medium; Magnetic resonance imaging; Respiratory gating

Indexed keywords

CONTRAST MEDIUM;

EID: 84919491401     PISSN: 10649689     EISSN: 15579786     Source Type: Journal    
DOI: 10.1016/j.mric.2014.09.008     Document Type: Review
Times cited : (16)

References (34)
  • 1
    • 84893113465 scopus 로고    scopus 로고
    • Executive summary: heart disease and stroke statistics-2014 update: a report from the American Heart Association
    • Go A.S., Mozaffarian D., Roger V.L., et al. Executive summary: heart disease and stroke statistics-2014 update: a report from the American Heart Association. Circulation 2014, 129:399-410.
    • (2014) Circulation , vol.129 , pp. 399-410
    • Go, A.S.1    Mozaffarian, D.2    Roger, V.L.3
  • 2
    • 79952398815 scopus 로고    scopus 로고
    • Coronary CT versus MR angiography: pro CT-the role of CT angiography
    • Dewey M. Coronary CT versus MR angiography: pro CT-the role of CT angiography. Radiology 2011, 258:329-339.
    • (2011) Radiology , vol.258 , pp. 329-339
    • Dewey, M.1
  • 3
    • 77956525573 scopus 로고    scopus 로고
    • Assessment of coronary artery disease using magnetic resonance coronary angiography: a national multicenter trial
    • Kato S., Kitagawa K., Ishida N., et al. Assessment of coronary artery disease using magnetic resonance coronary angiography: a national multicenter trial. JAm Coll Cardiol 2010, 56:983-991.
    • (2010) JAm Coll Cardiol , vol.56 , pp. 983-991
    • Kato, S.1    Kitagawa, K.2    Ishida, N.3
  • 4
    • 25144439472 scopus 로고    scopus 로고
    • Assessment of coronary arteries with total study time of less than 30 minutes by using whole-heart coronary MR angiography
    • Sakuma H., Ichikawa Y., Suzawa N., et al. Assessment of coronary arteries with total study time of less than 30 minutes by using whole-heart coronary MR angiography. Radiology 2005, 237:316-321.
    • (2005) Radiology , vol.237 , pp. 316-321
    • Sakuma, H.1    Ichikawa, Y.2    Suzawa, N.3
  • 5
    • 27544463754 scopus 로고    scopus 로고
    • Rapid and complete coronary arterial tree visualization with magnetic resonance imaging: feasibility and diagnostic performance
    • Jahnke C., Paetsch I., Nehrke K., et al. Rapid and complete coronary arterial tree visualization with magnetic resonance imaging: feasibility and diagnostic performance. Eur Heart J 2005, 26:2313-2319.
    • (2005) Eur Heart J , vol.26 , pp. 2313-2319
    • Jahnke, C.1    Paetsch, I.2    Nehrke, K.3
  • 6
    • 33750948187 scopus 로고    scopus 로고
    • Detection of coronary artery stenosis with whole-heart coronary magnetic resonance angiography
    • Sakuma H., Ichikawa Y., Chino S., et al. Detection of coronary artery stenosis with whole-heart coronary magnetic resonance angiography. JAm Coll Cardiol 2006, 48:1946-1950.
    • (2006) JAm Coll Cardiol , vol.48 , pp. 1946-1950
    • Sakuma, H.1    Ichikawa, Y.2    Chino, S.3
  • 7
    • 79955023057 scopus 로고    scopus 로고
    • Diagnostic accuracy of 1.5-T unenhanced whole-heart coronary MR angiography performed with 32-channel cardiac coils: initial single-center experience
    • Nagata M., Kato S., Kitagawa K., et al. Diagnostic accuracy of 1.5-T unenhanced whole-heart coronary MR angiography performed with 32-channel cardiac coils: initial single-center experience. Radiology 2011, 259:384-392.
    • (2011) Radiology , vol.259 , pp. 384-392
    • Nagata, M.1    Kato, S.2    Kitagawa, K.3
  • 8
    • 58749085886 scopus 로고    scopus 로고
    • Combined magnetic resonance coronary artery imaging, myocardial perfusion and late gadolinium enhancement in patients with suspected coronary artery disease
    • Klein C., Gebker R., Kokocinski T., et al. Combined magnetic resonance coronary artery imaging, myocardial perfusion and late gadolinium enhancement in patients with suspected coronary artery disease. JCardiovasc Magn Reson 2008, 10:45.
    • (2008) JCardiovasc Magn Reson , vol.10 , pp. 45
    • Klein, C.1    Gebker, R.2    Kokocinski, T.3
  • 9
    • 84888646577 scopus 로고    scopus 로고
    • Diagnostic performance of non-contrast-enhanced whole-heart magnetic resonance coronary angiography in combination with adenosine stress perfusion cardiac magnetic resonance imaging
    • Heer T., Reiter S., Höfling B., et al. Diagnostic performance of non-contrast-enhanced whole-heart magnetic resonance coronary angiography in combination with adenosine stress perfusion cardiac magnetic resonance imaging. Am Heart J 2013, 166:999-1009.
    • (2013) Am Heart J , vol.166 , pp. 999-1009
    • Heer, T.1    Reiter, S.2    Höfling, B.3
  • 10
    • 0030966347 scopus 로고    scopus 로고
    • Comparison of respiratory suppression methods and navigator locations for MR coronary angiography
    • McConnell M.V., Khasgiwala V.C., Savord B.J., et al. Comparison of respiratory suppression methods and navigator locations for MR coronary angiography. Am J Roentgenol 1997, 168:1369-1375.
    • (1997) Am J Roentgenol , vol.168 , pp. 1369-1375
    • McConnell, M.V.1    Khasgiwala, V.C.2    Savord, B.J.3
  • 11
    • 0029851614 scopus 로고    scopus 로고
    • Coronary arteries: three-dimensional MR imaging with retrospective respiratory gating
    • Li D., Kaushikkar S., Haacke E.M., et al. Coronary arteries: three-dimensional MR imaging with retrospective respiratory gating. Radiology 1996, 201:857-863.
    • (1996) Radiology , vol.201 , pp. 857-863
    • Li, D.1    Kaushikkar, S.2    Haacke, E.M.3
  • 12
    • 0029952524 scopus 로고    scopus 로고
    • Three-dimensional respiratory-gated MR angiography of coronary arteries: comparison with conventional coronary angiography
    • Post J.C., van Rossum A.C., Hofman M.B., et al. Three-dimensional respiratory-gated MR angiography of coronary arteries: comparison with conventional coronary angiography. Am J Roentgenol 1996, 166:1399-1404.
    • (1996) Am J Roentgenol , vol.166 , pp. 1399-1404
    • Post, J.C.1    van Rossum, A.C.2    Hofman, M.B.3
  • 13
    • 0031940113 scopus 로고    scopus 로고
    • Detection of coronary stenoses on source and projection images using three-dimensional MR angiography with retrospective respiratory gating: preliminary experience
    • Woodard P.K., Li D., Haacke E.M., et al. Detection of coronary stenoses on source and projection images using three-dimensional MR angiography with retrospective respiratory gating: preliminary experience. Am J Roentgenol 1998, 170:883-888.
    • (1998) Am J Roentgenol , vol.170 , pp. 883-888
    • Woodard, P.K.1    Li, D.2    Haacke, E.M.3
  • 14
    • 84855566567 scopus 로고    scopus 로고
    • Impact of an abdominal belt on breathing patterns and scan efficiency in whole-heart coronary magnetic resonance angiography: comparison between the UK and Japan
    • Ishida M., Schuster A., Takase S., et al. Impact of an abdominal belt on breathing patterns and scan efficiency in whole-heart coronary magnetic resonance angiography: comparison between the UK and Japan. JCardiovasc Magn Reson 2011, 13:71.
    • (2011) JCardiovasc Magn Reson , vol.13 , pp. 71
    • Ishida, M.1    Schuster, A.2    Takase, S.3
  • 15
    • 0034801295 scopus 로고    scopus 로고
    • Impact of bulk cardiac motion on right coronary MR angiography and vessel wall imaging
    • Kim W.Y., Stuber M., Kissinger K.V., et al. Impact of bulk cardiac motion on right coronary MR angiography and vessel wall imaging. JMagn Reson Imaging 2001, 14:383-390.
    • (2001) JMagn Reson Imaging , vol.14 , pp. 383-390
    • Kim, W.Y.1    Stuber, M.2    Kissinger, K.V.3
  • 16
    • 0037306949 scopus 로고    scopus 로고
    • Three-dimensional coronary MR angiography performed with subject-specific cardiac acquisition windows and motion-adapted respiratory gating
    • Plein S., Jones T.R., Ridgway J.P., et al. Three-dimensional coronary MR angiography performed with subject-specific cardiac acquisition windows and motion-adapted respiratory gating. Am J Roentgenol 2003, 180:505-512.
    • (2003) Am J Roentgenol , vol.180 , pp. 505-512
    • Plein, S.1    Jones, T.R.2    Ridgway, J.P.3
  • 17
    • 0035023617 scopus 로고    scopus 로고
    • Cine MR angiography of the heart with segmented true fast imaging with steady-state precession
    • Carr J.C., Simonetti O., Bundy J., et al. Cine MR angiography of the heart with segmented true fast imaging with steady-state precession. Radiology 2001, 219:828-834.
    • (2001) Radiology , vol.219 , pp. 828-834
    • Carr, J.C.1    Simonetti, O.2    Bundy, J.3
  • 18
    • 0037381416 scopus 로고    scopus 로고
    • Coronary MR angiography: true FISP imaging improved by prolonging breath holds with preoxygenation in healthy volunteers
    • McCarthy R.M., Shea S.M., Deshpande V.S., et al. Coronary MR angiography: true FISP imaging improved by prolonging breath holds with preoxygenation in healthy volunteers. Radiology 2003, 227:283-288.
    • (2003) Radiology , vol.227 , pp. 283-288
    • McCarthy, R.M.1    Shea, S.M.2    Deshpande, V.S.3
  • 19
    • 0036708122 scopus 로고    scopus 로고
    • Preliminary report on invivo coronary MRA at 3 Tesla in humans
    • Stuber M., Botnar R.M., Fischer S.E., et al. Preliminary report on invivo coronary MRA at 3 Tesla in humans. Magn Reson Med 2002, 48:425-429.
    • (2002) Magn Reson Med , vol.48 , pp. 425-429
    • Stuber, M.1    Botnar, R.M.2    Fischer, S.E.3
  • 20
    • 13844296980 scopus 로고    scopus 로고
    • Coronary MR angiography at 3.0 T versus that at 1.5 T: initial results in patients suspected of having coronary artery disease
    • Sommer T., Hackenbroch M., Hofer U., et al. Coronary MR angiography at 3.0 T versus that at 1.5 T: initial results in patients suspected of having coronary artery disease. Radiology 2005, 234:718-725.
    • (2005) Radiology , vol.234 , pp. 718-725
    • Sommer, T.1    Hackenbroch, M.2    Hofer, U.3
  • 21
    • 8444225836 scopus 로고    scopus 로고
    • Evaluation of balanced steady-state free precession (TrueFISP) and K-space segmented gradient echo sequences for 3D coronary MR angiography with navigator gating at 3 Tesla
    • Kaul M.G., Stork A., Bansmann P.M., et al. Evaluation of balanced steady-state free precession (TrueFISP) and K-space segmented gradient echo sequences for 3D coronary MR angiography with navigator gating at 3 Tesla. Rofo 2004, 176:1560-1565.
    • (2004) Rofo , vol.176 , pp. 1560-1565
    • Kaul, M.G.1    Stork, A.2    Bansmann, P.M.3
  • 22
    • 0027403101 scopus 로고
    • Apreliminary report comparing magnetic resonance coronary angiography with conventional angiography
    • Manning W.J., Li W., Edelman R.R. Apreliminary report comparing magnetic resonance coronary angiography with conventional angiography. NEngl J Med 1993, 328:828-832.
    • (1993) NEngl J Med , vol.328 , pp. 828-832
    • Manning, W.J.1    Li, W.2    Edelman, R.R.3
  • 23
    • 0027280275 scopus 로고
    • Coronary arteries: three-dimensional MR imaging with fat saturation and magnetization transfer contrast
    • Li D., Paschal C.B., Haacke E.M., et al. Coronary arteries: three-dimensional MR imaging with fat saturation and magnetization transfer contrast. Radiology 1993, 187:401-406.
    • (1993) Radiology , vol.187 , pp. 401-406
    • Li, D.1    Paschal, C.B.2    Haacke, E.M.3
  • 24
    • 0033594967 scopus 로고    scopus 로고
    • Improved coronary artery definition with T2-weighted, free-breathing, three-dimensional coronary MRA
    • Botnar R.M., Stuber M., Danias P.G., et al. Improved coronary artery definition with T2-weighted, free-breathing, three-dimensional coronary MRA. Circulation 1999, 99:3139-3148.
    • (1999) Circulation , vol.99 , pp. 3139-3148
    • Botnar, R.M.1    Stuber, M.2    Danias, P.G.3
  • 25
    • 0033910516 scopus 로고    scopus 로고
    • Noninvasive detection of coronary artery stenosis using contrast-enhanced three-dimensional breath-hold magnetic resonance coronary angiography
    • Regenfus M., Ropers D., Achenbach S., et al. Noninvasive detection of coronary artery stenosis using contrast-enhanced three-dimensional breath-hold magnetic resonance coronary angiography. JAm Coll Cardiol 2000, 36:44-50.
    • (2000) JAm Coll Cardiol , vol.36 , pp. 44-50
    • Regenfus, M.1    Ropers, D.2    Achenbach, S.3
  • 26
    • 70350458179 scopus 로고    scopus 로고
    • Volume-targeted and whole-heart coronary magnetic resonance angiography using an intravascular contrast agent
    • Tang L., Merkle N., Schär M., et al. Volume-targeted and whole-heart coronary magnetic resonance angiography using an intravascular contrast agent. JMagn Reson Imaging 2009, 30:1191-1196.
    • (2009) JMagn Reson Imaging , vol.30 , pp. 1191-1196
    • Tang, L.1    Merkle, N.2    Schär, M.3
  • 27
    • 67449104912 scopus 로고    scopus 로고
    • Contrast-enhanced whole-heart coronary magnetic resonance angiography at 3.0-T: a comparative study with X-ray angiography in a single center
    • Yang Q., Li K., Liu X., et al. Contrast-enhanced whole-heart coronary magnetic resonance angiography at 3.0-T: a comparative study with X-ray angiography in a single center. JAm Coll Cardiol 2009, 54:69-76.
    • (2009) JAm Coll Cardiol , vol.54 , pp. 69-76
    • Yang, Q.1    Li, K.2    Liu, X.3
  • 28
    • 34247590053 scopus 로고    scopus 로고
    • Comparative study of the physicochemical properties of six clinical low molecular weight gadolinium contrast agents
    • Laurent S., Elst L.V., Muller R.N. Comparative study of the physicochemical properties of six clinical low molecular weight gadolinium contrast agents. Contrast Media Mol Imaging 2006, 1:128-137.
    • (2006) Contrast Media Mol Imaging , vol.1 , pp. 128-137
    • Laurent, S.1    Elst, L.V.2    Muller, R.N.3
  • 29
    • 68449091892 scopus 로고    scopus 로고
    • Gd-BOPTA for assessment of myocardial viability on MRI: changes of T1 value and their impact on delayed enhancement
    • Krombach G.A., Hahnen C., Lodemann K.P., et al. Gd-BOPTA for assessment of myocardial viability on MRI: changes of T1 value and their impact on delayed enhancement. Eur Radiol 2009, 19:2136-2146.
    • (2009) Eur Radiol , vol.19 , pp. 2136-2146
    • Krombach, G.A.1    Hahnen, C.2    Lodemann, K.P.3
  • 30
    • 0032810872 scopus 로고    scopus 로고
    • Submillimeter three-dimensional coronary MR angiography with real-time navigator correction: comparison of navigator locations
    • Stuber M., Botnar R.M., Danias P.G., et al. Submillimeter three-dimensional coronary MR angiography with real-time navigator correction: comparison of navigator locations. Radiology 1999, 212:579-587.
    • (1999) Radiology , vol.212 , pp. 579-587
    • Stuber, M.1    Botnar, R.M.2    Danias, P.G.3
  • 31
    • 84863843182 scopus 로고    scopus 로고
    • Respiratory self-navigation for whole-heart bright-blood coronary MRI: methods for robust isolation and automatic segmentation of the blood pool
    • Piccini D., Littmann A., Nielles-Vallespin S., et al. Respiratory self-navigation for whole-heart bright-blood coronary MRI: methods for robust isolation and automatic segmentation of the blood pool. Magn Reson Med 2012, 68:571-579.
    • (2012) Magn Reson Med , vol.68 , pp. 571-579
    • Piccini, D.1    Littmann, A.2    Nielles-Vallespin, S.3
  • 32
    • 84856211673 scopus 로고    scopus 로고
    • Whole-heart coronary MR angiography with 2D self-navigated image reconstruction
    • Henningsson M., Koken P., Stehning C., et al. Whole-heart coronary MR angiography with 2D self-navigated image reconstruction. Magn Reson Med 2012, 67:437-445.
    • (2012) Magn Reson Med , vol.67 , pp. 437-445
    • Henningsson, M.1    Koken, P.2    Stehning, C.3
  • 33
    • 84865420892 scopus 로고    scopus 로고
    • Accelerated late gadolinium enhancement cardiac MR imaging with isotropic spatial resolution using compressed sensing: initial experience
    • Akçakaya M., Rayatzadeh H., Basha T.A., et al. Accelerated late gadolinium enhancement cardiac MR imaging with isotropic spatial resolution using compressed sensing: initial experience. Radiology 2012, 264:691-699.
    • (2012) Radiology , vol.264 , pp. 691-699
    • Akçakaya, M.1    Rayatzadeh, H.2    Basha, T.A.3
  • 34
    • 84892432868 scopus 로고    scopus 로고
    • Accelerated isotropic sub-millimeter whole-heart coronary MRI: compressed sensing versus parallel imaging
    • Akçakaya M., Basha T.A., Chan R.H., et al. Accelerated isotropic sub-millimeter whole-heart coronary MRI: compressed sensing versus parallel imaging. Magn Reson Med 2014, 71:815-822.
    • (2014) Magn Reson Med , vol.71 , pp. 815-822
    • Akçakaya, M.1    Basha, T.A.2    Chan, R.H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.