메뉴 건너뛰기




Volumn 207, Issue PB, 2015, Pages 1010-1018

Effect of surface conductivity on the sensitivity of interdigitated impedimetric sensors and their design considerations

Author keywords

Electrical double layer; FEM modeling; Impedimetric biosensor; Interdigitated electrodes; Surface conductivity

Indexed keywords

DESIGN; DIELECTRIC MATERIALS; ELECTRIC CONDUCTIVITY; ELECTRODES; GEOMETRY; SENSITIVITY ANALYSIS; SURFACE REACTIONS;

EID: 84919362583     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2014.10.134     Document Type: Article
Times cited : (27)

References (31)
  • 1
    • 34547578768 scopus 로고    scopus 로고
    • Label-free impedance biosensors: Opportunities and challenges
    • J.S. Daniels, N. Pourmand, Label-free impedance biosensors: opportunities and challenges, Electroanalysis 19 (123) (2007) 9-1257, http://dx.doi.org/10.1002/elan.200603855.
    • (2007) Electroanalysis , vol.19 , Issue.123 , pp. 9-1257
    • Daniels, J.S.1    Pourmand, N.2
  • 2
    • 0035975024 scopus 로고    scopus 로고
    • Electrochemical impedance spectroscopy as a platform for reagentless bioaffinity sensing
    • G. Lillie, P. Payne, P. Vadgama, Electrochemical impedance spectroscopy as a platform for reagentless bioaffinity sensing, Sens. Actuators B Chem. 78 (2001) 249-256, http://dx.doi.org/10.1016/S0925-4005(01)00821-8.
    • (2001) Sens. Actuators B Chem. , vol.78 , pp. 249-256
    • Lillie, G.1    Payne, P.2    Vadgama, P.3
  • 5
    • 0035087692 scopus 로고    scopus 로고
    • Capacitive biosensors
    • C. Berggren, B. Bjarnason, G. Johansson, Capacitive biosensors, Electroanalysis 13 (2001) 173-180, http://dx.doi.org/10.1002/1521-4109(200103)13:3〈173::AID-ELAN173〉3.0.CO;2-B.
    • (2001) Electroanalysis , vol.13 , pp. 173-180
    • Berggren, C.1    Bjarnason, B.2    Johansson, G.3
  • 7
    • 25844457062 scopus 로고    scopus 로고
    • Labelfree impedance detection of oligonucleotide hybridisation on interdigitated ultramicroelectrodes using electrochemical redox probes
    • V. Dharuman, T. Grunwald, E. Nebling, J. Albers, L. Blohm, R. Hintsche, Labelfree impedance detection of oligonucleotide hybridisation on interdigitated ultramicroelectrodes using electrochemical redox probes, Biosens. Bioelectron. 21 (2005) 645-654, http://dx.doi.org/10.1016/j.bios.2004.12.020.
    • (2005) Biosens. Bioelectron. , vol.21 , pp. 645-654
    • Dharuman, V.1    Grunwald, T.2    Nebling, E.3    Albers, J.4    Blohm, L.5    Hintsche, R.6
  • 8
    • 45849116521 scopus 로고    scopus 로고
    • The use of electrochemical impedance spectroscopy for biosensing
    • F. Lisdat, D. Schäfer, The use of electrochemical impedance spectroscopy for biosensing, Anal. Bioanal. Chem. 391 (2008) 1555-1567, http://dx.doi.org/10.1007/s00216-008-1970-7.
    • (2008) Anal. Bioanal. Chem. , vol.391 , pp. 1555-1567
    • Lisdat, F.1    Schäfer, D.2
  • 9
    • 38849149068 scopus 로고    scopus 로고
    • Label-free detection of DNA with interdigitated micro-electrodes in a fluidic cell
    • D. Berdat, A.C.M. Rodríguez, F. Herrera, M.A.M. Gijs, Label-free detection of DNA with interdigitated micro-electrodes in a fluidic cell, Lab. Chip. 8 (2008) 302-308, http://dx.doi.org/10.1039/B712609C.
    • (2008) Lab. Chip. , vol.8 , pp. 302-308
    • Berdat, D.1    Rodríguez, A.C.M.2    Herrera, F.3    Gijs, M.A.M.4
  • 10
    • 0036839346 scopus 로고    scopus 로고
    • Parameter estimation in dielectrometry measurements
    • A.V. Mamishev, A.R. Takahashi, Y. Du, B.C. Lesieutre, M. Zahn, Parameter estimation in dielectrometry measurements, J. Electrostat. 56 (2002) 465-492, http://dx.doi.org/10.1016/S0304-3886(02)00068-2.
    • (2002) J. Electrostat. , vol.56 , pp. 465-492
    • Mamishev, A.V.1    Takahashi, A.R.2    Du, Y.3    Lesieutre, B.C.4    Zahn, M.5
  • 11
    • 84868688722 scopus 로고    scopus 로고
    • Lateral flow impedance transducer for salmonella detection
    • M. Navaei, J. Xu, P. Hesketh, W. Daley, S. Grullon, Lateral flow impedance transducer for salmonella detection, ECS Trans. 35 (2) (2011) 7-34, http://dx.doi.org/10.1149/1.3653211.
    • (2011) ECS Trans. , vol.35 , Issue.2 , pp. 7-34
    • Navaei, M.1    Xu, J.2    Hesketh, P.3    Daley, W.4    Grullon, S.5
  • 12
    • 52149107352 scopus 로고    scopus 로고
    • Characterisation of the interdigitated electrode array with tantalum silicide electrodes separated by insulating barriers
    • A. Bratov, N. Abramova, J. Ramón-Azcón, A. Merlos, F. Sánchez-Baeza, M.-P. Marco, et al., Characterisation of the interdigitated electrode array with tantalum silicide electrodes separated by insulating barriers, Electrochem. Commun. 10 (2008) 1621-1624, http://dx.doi.org/10.1016/j.elecom.2008.07.037.
    • (2008) Electrochem. Commun. , vol.10 , pp. 1621-1624
    • Bratov, A.1    Abramova, N.2    Ramón-Azcón, J.3    Merlos, A.4    Sánchez-Baeza, F.5    Marco, M.-P.6
  • 13
    • 53249095481 scopus 로고    scopus 로고
    • Three-dimensional interdigitated electrode array as a transducer for label-free biosensors
    • A. Bratov, J. Ramón-Azcón, N. Abramova, A. Merlos, J. Adrian, F. Sánchez-Baeza, et al., Three-dimensional interdigitated electrode array as a transducer for label-free biosensors, Biosens. Bioelectron. 24 (2008) 729-735, http://dx.doi.org/10.1016/j.bios.2008.06.057.
    • (2008) Biosens. Bioelectron. , vol.24 , pp. 729-735
    • Bratov, A.1    Ramón-Azcón, J.2    Abramova, N.3    Merlos, A.4    Adrian, J.5    Sánchez-Baeza, F.6
  • 14
    • 84855372594 scopus 로고    scopus 로고
    • Three-dimensional interdigitated electrode array as a tool for surface reactions registration
    • A. Bratov, N. Abramova, M.P. Marco, F. Sanchez-Baeza, Three-dimensional interdigitated electrode array as a tool for surface reactions registration, Electroanalysis 24 (6) (2012) 9-75, http://dx.doi.org/10.1002/elan.201100392.
    • (2012) Electroanalysis , vol.24 , Issue.6 , pp. 9-75
    • Bratov, A.1    Abramova, N.2    Marco, M.P.3    Sanchez-Baeza, F.4
  • 15
    • 80053919047 scopus 로고    scopus 로고
    • Comparison of planar and 3-D interdigitated electrodes as electrochemical impedance biosensors
    • S. Rana, R.H. Page, C.J. McNeil, Comparison of planar and 3-D interdigitated electrodes as electrochemical impedance biosensors, Electroanalysis 23 (248) (2011) 5-2490, http://dx.doi.org/10.1002/elan.201100353.
    • (2011) Electroanalysis , vol.23 , Issue.248 , pp. 5-2490
    • Rana, S.1    Page, R.H.2    McNeil, C.J.3
  • 16
    • 84868270281 scopus 로고    scopus 로고
    • A new microcapillary device for controlling surface conductivity changes at solid-liquid interface
    • A. Bratov, N. Abramova, A new microcapillary device for controlling surface conductivity changes at solid-liquid interface, Chem. Lett. 41 (2012) 1244-1246, http://dx.doi.org/10.1246/cl.2012.1244.
    • (2012) Chem. Lett. , vol.41 , pp. 1244-1246
    • Bratov, A.1    Abramova, N.2
  • 17
    • 84878543773 scopus 로고    scopus 로고
    • Response of a microcapillary impedimetric transducer to changes in surface conductance at liquid/solid interface
    • A. Bratov, N. Abramova, Response of a microcapillary impedimetric transducer to changes in surface conductance at liquid/solid interface, J. Colloid Interface Sci. 403 (2013) 151-156, http://dx.doi.org/10.1016/j.jcis.2013.04.030.
    • (2013) J. Colloid Interface Sci. , vol.403 , pp. 151-156
    • Bratov, A.1    Abramova, N.2
  • 18
    • 78649572095 scopus 로고    scopus 로고
    • Antibody functionalized interdigitated μ-electrode (IDμE) based impedimetric cortisol biosensor
    • S.K. Arya, G. Chornokur, M. Venugopal, S. Bhansali, Antibody functionalized interdigitated μ-electrode (IDμE) based impedimetric cortisol biosensor, Analyst 135 (2010) 1941, http://dx.doi.org/10.1039/c0an00242a.
    • (2010) Analyst , vol.135 , pp. 1941
    • Arya, S.K.1    Chornokur, G.2    Venugopal, M.3    Bhansali, S.4
  • 19
    • 80755176790 scopus 로고    scopus 로고
    • Nanoparticle-enhanced sensitivity of a nanogap-interdigitated electrode array impedimetric biosensor
    • K.V. Singh, D.K. Bhura, G. Nandamuri, A.M. Whited, D. Evans, J. King, et al., Nanoparticle-enhanced sensitivity of a nanogap-interdigitated electrode array impedimetric biosensor, Langmuir 27 (1393) (2011) 1-13939, http://dx.doi.org/10.1021/la202546a.
    • (2011) Langmuir , vol.27 , Issue.1393 , pp. 1-13939
    • Singh, K.V.1    Bhura, D.K.2    Nandamuri, G.3    Whited, A.M.4    Evans, D.5    King, J.6
  • 20
    • 34247637151 scopus 로고    scopus 로고
    • Functionalized nano interdigitated electrodes arrays on polymer with integrated microfluidics for direct bio-affinity sensing using impedimetric measurement
    • Z. Zou, J. Kai, M.J. Rust, J. Han, C.H. Ahn, Functionalized nano interdigitated electrodes arrays on polymer with integrated microfluidics for direct bio-affinity sensing using impedimetric measurement, Sens. Actuators Phys. 136 (2007) 518-526, http://dx.doi.org/10.1016/j.sna.2006.12.006.
    • (2007) Sens. Actuators Phys. , vol.136 , pp. 518-526
    • Zou, Z.1    Kai, J.2    Rust, M.J.3    Han, J.4    Ahn, C.H.5
  • 21
    • 84862816145 scopus 로고    scopus 로고
    • Fabrication of submicron-gap electrodes by silicon volume expansion for DNA-detection
    • X. Chen, J. Zhang, Z. Wang, Q. Yan, Fabrication of submicron-gap electrodes by silicon volume expansion for DNA-detection, Sens. Actuators Phys. 175 (2012) 73-77, http://dx.doi.org/10.1016/j.sna.2011.12.046.
    • (2012) Sens. Actuators Phys. , vol.175 , pp. 73-77
    • Chen, X.1    Zhang, J.2    Wang, Z.3    Yan, Q.4
  • 22
    • 40849142071 scopus 로고    scopus 로고
    • An impedimetric immunosensor based on interdigitated microelectrodes (IDμE) for the determination of atrazine residues in food samples
    • J. Ramón-Azcón, E. Valera, Á. Rodríguez, A. Barranco, B. Alfaro, F. Sanchez-Baeza, et al., An impedimetric immunosensor based on interdigitated microelectrodes (IDμE) for the determination of atrazine residues in food samples, Biosens. Bioelectron. 23 (2008) 1367-1373, http://dx.doi.org/10.1016/j.bios.2007.12.010.
    • (2008) Biosens. Bioelectron. , vol.23 , pp. 1367-1373
    • Ramón-Azcón, J.1    Valera, E.2    Rodríguez, Á.3    Barranco, A.4    Alfaro, B.5    Sanchez-Baeza, F.6
  • 23
    • 84892099726 scopus 로고    scopus 로고
    • Chemical sensors and biosensors based on impedimetric interdigitated electrode array transducers
    • D.E. Suarez (Ed.), Nova Science Publishers Inc., New York
    • A. Bratov, N. Abramova, Chemical sensors and biosensors based on impedimetric interdigitated electrode array transducers, in: D.E. Suarez (Ed.), Smart Sens. Sens. Technol., Nova Science Publishers Inc., New York, 2013, pp. 129-153.
    • (2013) Smart Sens. Sens. Technol. , pp. 129-153
    • Bratov, A.1    Abramova, N.2
  • 24
    • 33747847767 scopus 로고    scopus 로고
    • Electrokinetic microslit experiments to analyse the charge formation at solid/liquid interfaces
    • R. Zimmermann, T. Osaki, R. Schweiß, C. Werner, Electrokinetic microslit experiments to analyse the charge formation at solid/liquid interfaces, Microfluid. Nanofluidics. 2 (2006) 367-379, http://dx.doi.org/10.1007/s10404-006-0087-6.
    • (2006) Microfluid. Nanofluidics. , vol.2 , pp. 367-379
    • Zimmermann, R.1    Osaki, T.2    Schweiß, R.3    Werner, C.4
  • 25
    • 0014986362 scopus 로고
    • An application of electrocardiographic lead theory to impedance plethysmography
    • D.B. Geselowitz, An application of electrocardiographic lead theory to impedance plethysmography, IEEE Trans. Biomed. Eng. 18 (1971) 38-41, http://dx.doi.org/10.1109/TBME.1971.4502787.
    • (1971) IEEE Trans. Biomed. Eng. , vol.18 , pp. 38-41
    • Geselowitz, D.B.1
  • 26
    • 33947685450 scopus 로고    scopus 로고
    • Sources of error in tetrapolar impedance measurements on biomaterials and other ionic conductors
    • S. Grimnes, O.G. Martinsen, Sources of error in tetrapolar impedance measurements on biomaterials and other ionic conductors, J. Phys. Appl. Phys. 40 (2007) 9-14.
    • (2007) J. Phys. Appl. Phys. , vol.40 , pp. 9-14
    • Grimnes, S.1    Martinsen, O.G.2
  • 27
    • 78449269059 scopus 로고    scopus 로고
    • Non-invasive assessment of corneal endothelial permeability by means of electrical impedance measurements
    • A. Guimera, A. Ivorra, G. Gabriel, R. Villa, Non-invasive assessment of corneal endothelial permeability by means of electrical impedance measurements, Med. Eng. Phys. 32 (2010) 1107-1115, http://dx.doi.org/10.1016/j.medengphy.2010.07.016.
    • (2010) Med. Eng. Phys. , vol.32 , pp. 1107-1115
    • Guimera, A.1    Ivorra, A.2    Gabriel, G.3    Villa, R.4
  • 28
    • 43249095153 scopus 로고    scopus 로고
    • A simulation study on the effect of thoracic conductivity inhomogeneities on sensitivity distributions
    • F. Yang, R.P. Patterson, A simulation study on the effect of thoracic conductivity inhomogeneities on sensitivity distributions, Ann. Biomed. Eng. 36 (2008) 762-768, http://dx.doi.org/10.1007/s10439-008-9469-0.
    • (2008) Ann. Biomed. Eng. , vol.36 , pp. 762-768
    • Yang, F.1    Patterson, R.P.2
  • 29
    • 0034659711 scopus 로고    scopus 로고
    • The ς-potential of glass surface in contact with aqueous solutions
    • Y. Gu, D. Li, The ς-potential of glass surface in contact with aqueous solutions, J. Colloid Interface Sci. 226 (2000) 328-339, http://dx.doi.org/10.1006/jcis.2000.6827.
    • (2000) J. Colloid Interface Sci. , vol.226 , pp. 328-339
    • Gu, Y.1    Li, D.2
  • 31
    • 84902553413 scopus 로고    scopus 로고
    • Planar and 3D interdigitated electrodes for biosensing applications: The impact of a dielectric barrier on the sensor properties
    • M. Bäcker, F. Kramer, C. Huck, A. Poghossian, A. Bratov, N. Abramova, et al., Planar and 3D interdigitated electrodes for biosensing applications: the impact of a dielectric barrier on the sensor properties, Phys. Status Solidi A 211 (2014) 1357-1363, http://dx.doi.org/10.1002/pssa.201330416.
    • (2014) Phys. Status Solidi A , vol.211 , pp. 1357-1363
    • Bäcker, M.1    Kramer, F.2    Huck, C.3    Poghossian, A.4    Bratov, A.5    Abramova, N.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.