메뉴 건너뛰기




Volumn 23, Issue 10, 2014, Pages 2196-2202

Influence of the screw augmentation technique and a diameter increase on pedicle screw fixation in the osteoporotic spine: pullout versus fatigue testing

Author keywords

Cement augmentation; Fatigue; Pedicle screw; Pullout; Spine; Toggle

Indexed keywords

ACRYLIC ACID RESIN; CEMENT; POLYURETHAN; BONE CEMENT;

EID: 84919330569     PISSN: 09406719     EISSN: 14320932     Source Type: Journal    
DOI: 10.1007/s00586-014-3476-7     Document Type: Article
Times cited : (107)

References (25)
  • 1
    • 0033794424 scopus 로고    scopus 로고
    • The use of pedicle-screw internal fixation for the operative treatment of spinal disorders
    • PID: 11057475
    • Gaines RW (2000) The use of pedicle-screw internal fixation for the operative treatment of spinal disorders. J Bone Joint Surg Am 82-A:1458–1476
    • (2000) J Bone Joint Surg Am , vol.82-A , pp. 1458-1476
    • Gaines, R.W.1
  • 2
    • 77955385364 scopus 로고    scopus 로고
    • The biomechanics of pedicle screw-based instrumentation
    • PID: 20675747, COI: 1:STN:280:DC%2BC3cjhslaqtQ%3D%3D
    • Cho W, Cho SK, Wu C (2010) The biomechanics of pedicle screw-based instrumentation. J Bone Joint Surg Br 92:1061–1065. doi:10.1302/0301-620X.92B8.24237
    • (2010) J Bone Joint Surg Br , vol.92 , pp. 1061-1065
    • Cho, W.1    Cho, S.K.2    Wu, C.3
  • 4
    • 0028046151 scopus 로고
    • Comprehensive literature review. Pedicle screw fixation devices
    • PID: 7817242, COI: 1:STN:280:DyaK2M7hs12ksQ%3D%3D
    • Yahiro MA (1994) Comprehensive literature review. Pedicle screw fixation devices. Spine 19:2274S–2278S
    • (1994) Spine , vol.19 , pp. 2274S-2278S
    • Yahiro, M.A.1
  • 5
    • 0028036716 scopus 로고
    • A historical cohort study of pedicle screw fixation in thoracic, lumbar, and sacral spinal fusion
    • PID: 7817243, COI: 1:STN:280:DyaK2M7hs12ktg%3D%3D
    • Yuan HA, Garfin SR, Dickman CA, Mardjetko SM (1994) A historical cohort study of pedicle screw fixation in thoracic, lumbar, and sacral spinal fusion. Spine 19:2279S–2296S
    • (1994) Spine , vol.19 , pp. 2279S-2296S
    • Yuan, H.A.1    Garfin, S.R.2    Dickman, C.A.3    Mardjetko, S.M.4
  • 6
    • 0028034777 scopus 로고
    • Effects of bone mineral density on pedicle screw fixation
    • PID: 7846594, COI: 1:STN:280:DyaK2M7kvFWqtQ%3D%3D
    • Halvorson TL, Kelley LA, Thomas KA, Whitecloud TS III, Cook SD (1994) Effects of bone mineral density on pedicle screw fixation. Spine 19:2415–2420
    • (1994) Spine , vol.19 , pp. 2415-2420
    • Halvorson, T.L.1    Kelley, L.A.2    Thomas, K.A.3    Whitecloud, T.S.4    Cook, S.D.5
  • 7
    • 0025988460 scopus 로고
    • An experimental study on transpedicular screw fixation in relation to osteoporosis of the lumbar spine
    • PID: 1750009, COI: 1:STN:280:DyaK38%2Fos12nsg%3D%3D
    • Soshi S, Shiba R, Kondo H, Murota K (1991) An experimental study on transpedicular screw fixation in relation to osteoporosis of the lumbar spine. Spine 16:1335–1341
    • (1991) Spine , vol.16 , pp. 1335-1341
    • Soshi, S.1    Shiba, R.2    Kondo, H.3    Murota, K.4
  • 9
    • 84872385504 scopus 로고    scopus 로고
    • Pedicle screw design and cement augmentation in osteoporotic vertebrae: effects of fenestrations and cement viscosity on fixation and extraction
    • PID: 22996264
    • Choma TJ, Pfeiffer FM, Swope RW, Hirner JP (2012) Pedicle screw design and cement augmentation in osteoporotic vertebrae: effects of fenestrations and cement viscosity on fixation and extraction. Spine 37:E1628–E1632
    • (2012) Spine , vol.37 , pp. E1628-E1632
    • Choma, T.J.1    Pfeiffer, F.M.2    Swope, R.W.3    Hirner, J.P.4
  • 10
    • 58949104443 scopus 로고    scopus 로고
    • Biomechanical analysis of different techniques in revision spinal instrumentation: larger diameter screws versus cement augmentation
    • PID: 19011543
    • Kiner DW, Wybo CD, Sterba W, Yeni YN, Bartol SW, Vaidya R (2008) Biomechanical analysis of different techniques in revision spinal instrumentation: larger diameter screws versus cement augmentation. Spine 33:2618
    • (2008) Spine , vol.33 , pp. 2618
    • Kiner, D.W.1    Wybo, C.D.2    Sterba, W.3    Yeni, Y.N.4    Bartol, S.W.5    Vaidya, R.6
  • 11
    • 0037529207 scopus 로고    scopus 로고
    • Clinical relevance of pull-out strength testing of pedicle screws
    • Dawson JM, Boschert P, Macenski M, Rand N (2003) Clinical relevance of pull-out strength testing of pedicle screws. ASTM Spec Tech Publ 1431:68–80
    • (2003) ASTM Spec Tech Publ , vol.1431 , pp. 68-80
    • Dawson, J.M.1    Boschert, P.2    Macenski, M.3    Rand, N.4
  • 12
    • 84919367436 scopus 로고    scopus 로고
    • F543 standard specification and test methods for metallic medical bone screws
    • ASTM (2013) F543 standard specification and test methods for metallic medical bone screws. doi:10.1520/F0543
    • (2013) doi:10.1520/F0543
  • 13
    • 0027484342 scopus 로고
    • Complications associated with the technique of pedicle screw fixation a selected survey of ABS members
    • PID: 8278838, COI: 1:STN:280:DyaK2c7gsFOqtA%3D%3D
    • Esses SI, Sachs BL, Dreyzin V (1993) Complications associated with the technique of pedicle screw fixation a selected survey of ABS members. Spine 18:2231
    • (1993) Spine , vol.18 , pp. 2231
    • Esses, S.I.1    Sachs, B.L.2    Dreyzin, V.3
  • 14
    • 0029439303 scopus 로고
    • Complications of transpedicular reduction and stabilization of the thoracolumbar spine
    • PID: 8541735, COI: 1:STN:280:DyaK287ivFyhuw%3D%3D
    • Lee TC (1995) Complications of transpedicular reduction and stabilization of the thoracolumbar spine. J Formos Med Assoc 94:738–741
    • (1995) J Formos Med Assoc , vol.94 , pp. 738-741
    • Lee, T.C.1
  • 15
    • 0028600649 scopus 로고
    • Complications after transpedicular stabilization of the spine: a survivorship analysis of 163 cases
    • PID: 7899978, COI: 1:STN:280:DyaK2M3gslyrtA%3D%3D
    • Ohlin A, Karlsson M, Düppe H, Hasserius R, Redlund-Johnell I (1994) Complications after transpedicular stabilization of the spine: a survivorship analysis of 163 cases. Spine 19:2774–2779
    • (1994) Spine , vol.19 , pp. 2774-2779
    • Ohlin, A.1    Karlsson, M.2    Düppe, H.3    Hasserius, R.4    Redlund-Johnell, I.5
  • 16
    • 79952991395 scopus 로고    scopus 로고
    • Biomechanical analysis of pedicle screws in osteoporotic bone with bioactive cement augmentation using simulated in vivo multicomponent loading
    • PID: 20881517
    • Choma TJ, Frevert WF, Carson WL, Waters NP, Pfeiffer FM (2011) Biomechanical analysis of pedicle screws in osteoporotic bone with bioactive cement augmentation using simulated in vivo multicomponent loading. Spine 36:454–462. doi:10.1097/BRS.0b013e3181d449ec
    • (2011) Spine , vol.36 , pp. 454-462
    • Choma, T.J.1    Frevert, W.F.2    Carson, W.L.3    Waters, N.P.4    Pfeiffer, F.M.5
  • 17
    • 34247637260 scopus 로고    scopus 로고
    • Primary pedicle screw augmentation in osteoporotic lumbar vertebrae: biomechanical analysis of pedicle fixation strength
    • PID: 17471088
    • Burval DJ, McLain RF, Milks R, Inceoglu S (2007) Primary pedicle screw augmentation in osteoporotic lumbar vertebrae: biomechanical analysis of pedicle fixation strength. Spine 32:1077–1083
    • (2007) Spine , vol.32 , pp. 1077-1083
    • Burval, D.J.1    McLain, R.F.2    Milks, R.3    Inceoglu, S.4
  • 18
    • 56349095102 scopus 로고    scopus 로고
    • Assessment of different screw augmentation techniques and screw designs in osteoporotic spines
    • PID: 18781342, COI: 1:STN:280:DC%2BD1cjktFGitw%3D%3D
    • Becker S, Chavanne A, Spitaler R, Kropik K, Aigner N, Ogon M, Redl H (2008) Assessment of different screw augmentation techniques and screw designs in osteoporotic spines. Eur Spine J 17:1462–1469. doi:10.1007/s00586-008-0769-8
    • (2008) Eur Spine J , vol.17 , pp. 1462-1469
    • Becker, S.1    Chavanne, A.2    Spitaler, R.3    Kropik, K.4    Aigner, N.5    Ogon, M.6    Redl, H.7
  • 19
    • 0027426783 scopus 로고
    • Effect of screw diameter, insertion technique, and bone cement augmentation of pedicular screw fixation strength
    • PID: 8222439
    • Wittenberg RH, Lee KS, Shea M, White AA, Hayes WC (1993) Effect of screw diameter, insertion technique, and bone cement augmentation of pedicular screw fixation strength. Clin Orthop Relat Res 296:278–287
    • (1993) Clin Orthop Relat Res , vol.296 , pp. 278-287
    • Wittenberg, R.H.1    Lee, K.S.2    Shea, M.3    White, A.A.4    Hayes, W.C.5
  • 21
    • 77956398094 scopus 로고    scopus 로고
    • Revision of cannulated and perforated cement-augmented pedicle screws: a biomechanical study in human cadavers
    • PID: 20508553
    • Bullmann V, Schmoelz W, Richter M, Grathwohl C, Schulte TL (2010) Revision of cannulated and perforated cement-augmented pedicle screws: a biomechanical study in human cadavers. Spine 35:E932–E939
    • (2010) Spine , vol.35 , pp. E932-E939
    • Bullmann, V.1    Schmoelz, W.2    Richter, M.3    Grathwohl, C.4    Schulte, T.L.5
  • 22
    • 0011735919 scopus 로고    scopus 로고
    • Implantatverankerung in osteoporotischem Knochen mittels monokortikaler Schrauben
    • Seebeck J, Lill C, Morlock M, Schneider E (1999) Implantatverankerung in osteoporotischem Knochen mittels monokortikaler Schrauben. Trauma Berufskrankheit 1:411–414
    • (1999) Trauma Berufskrankheit , vol.1 , pp. 411-414
    • Seebeck, J.1    Lill, C.2    Morlock, M.3    Schneider, E.4
  • 23
    • 78149281362 scopus 로고    scopus 로고
    • Calcium phosphate cement augmentation of cancellous bone screws can compensate for the absence of cortical fixation
    • PID: 20728888
    • Stadelmann VA, Bretton E, Terrier A, Procter P, Pioletti DP (2010) Calcium phosphate cement augmentation of cancellous bone screws can compensate for the absence of cortical fixation. J Biomech 43:2869–2874. doi:10.1016/j.jbiomech.2010.07.025
    • (2010) J Biomech , vol.43 , pp. 2869-2874
    • Stadelmann, V.A.1    Bretton, E.2    Terrier, A.3    Procter, P.4    Pioletti, D.P.5
  • 25
    • 0031060065 scopus 로고    scopus 로고
    • Loads on an internal spinal fixation device during walking
    • PID: 8970923, COI: 1:STN:280:DyaK2s7isFymsw%3D%3D
    • Rohlmann A, Bergmann G, Graichen F (1997) Loads on an internal spinal fixation device during walking. J Biomech 30:41–47
    • (1997) J Biomech , vol.30 , pp. 41-47
    • Rohlmann, A.1    Bergmann, G.2    Graichen, F.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.