1
-
-
77951143798
-
Functional outcome of computer-assisted spinal pedicle screw placement: A systematic review and meta-analysis of 23 studies including 5,992 pedicle screws
-
Verma R., Krishan S., Haendlmayer K. et al. Functional outcome of computer-assisted spinal pedicle screw placement: a systematic review and meta-analysis of 23 studies including 5,992 pedicle screws. Eur Spine J: 2010; 19 370 375
-
(2010)
Eur Spine J
, vol.19
, pp. 370-375
-
-
Verma, R.1
Krishan, S.2
Haendlmayer, K.3
-
2
-
-
33846421082
-
Cervical pedicle screw placement: Feasibility and accuracy of two new insertion techniques based on morphometric data
-
DOI 10.1007/s00586-006-0104-1
-
Reinhold M., Magerl F., Rieger M. et al. Cervical pedicle screw placement: feasibility and accuracy of two new insertion techniques based on morphometric data. Eur Spine J: 2007; 16 47 56 (Pubitemid 46147227)
-
(2007)
European Spine Journal
, vol.16
, Issue.1
, pp. 47-56
-
-
Reinhold, M.1
Magerl, F.2
Rieger, M.3
Blauth, M.4
-
3
-
-
0032532465
-
Clinical relevance of accuracy of pedicle screw placement: A computed tomographic-supported analysis
-
DOI 10.1097/00007632-199810150-00014
-
Schulze C. J., Munzinger E., Weber U. Clinical relevance of accuracy of pedicle screw placement. A computed tomographic-supported analysis. Spine: 1998; 23 2215 2220 (Pubitemid 28485179)
-
(1998)
Spine
, vol.23
, Issue.20
, pp. 2215-2220
-
-
Schulze, C.J.1
Munzinger, E.2
Weber, U.3
-
4
-
-
77955385364
-
The biomechanics of pedicle screw-based instrumentation
-
Cho W., Cho S. K., Wu C. The biomechanics of pedicle screw-based instrumentation. J Bone Joint Surg [Br]: 2010; 92 1061 1065
-
(2010)
J Bone Joint Surg [Br]
, vol.92
, pp. 1061-1065
-
-
Cho, W.1
Cho, S.K.2
Wu, C.3
-
5
-
-
34447578691
-
A biomechanical cadaveric analysis of polymethylmethacrylate-augmented pedicle screw fixation
-
DOI 10.3171/SPI-07/07/047
-
Frankel B. M., DAgostino S., Wang C. A biomechanical cadaveric analysis of polymethylmethacrylate-augmented pedicle screw fixation. J Neurosurg Spine: 2007; 7 47 53 (Pubitemid 47071757)
-
(2007)
Journal of Neurosurgery: Spine
, vol.7
, Issue.1
, pp. 47-53
-
-
Frankel, B.M.1
D'Agostino, S.2
Wang, C.3
-
6
-
-
68749113746
-
Pullout strength for cannulated pedicle screws with bone cement augmentation in severely osteoporotic bone: Influences of radial hole and pilot hole tapping
-
Chen L. H., Tai C. L., Lai P. L. et al. Pullout strength for cannulated pedicle screws with bone cement augmentation in severely osteoporotic bone: influences of radial hole and pilot hole tapping. Clin Biomech (Bristol, Avon): 2009; 24 613 618
-
(2009)
Clin Biomech (Bristol, Avon)
, vol.24
, pp. 613-618
-
-
Chen, L.H.1
Tai, C.L.2
Lai, P.L.3
-
7
-
-
77954456491
-
Pedikelschraubenaugmentation aus biomechanischer Sicht
-
Bullmann V., Liljenqvist U. R., Rodl R. et al. Pedikelschraubenaugmentation aus biomechanischer Sicht. Orthopäde: 2010; 39 673 678
-
(2010)
Orthopäde
, vol.39
, pp. 673-678
-
-
Bullmann, V.1
Liljenqvist, U.R.2
Rodl, R.3
-
8
-
-
80052327624
-
Biomechanical comparison of different techniques in primary spinal surgery in osteoporotic cadaveric lumbar vertebrae: Expansive pedicle screw versus polymethylmethacrylate-augmented pedicle screw
-
Liu D., Wu Z. X., Pan X. M. et al. Biomechanical comparison of different techniques in primary spinal surgery in osteoporotic cadaveric lumbar vertebrae: expansive pedicle screw versus polymethylmethacrylate-augmented pedicle screw. Arch Orthop Trauma Surg: 2011; 131 1227 1232
-
(2011)
Arch Orthop Trauma Surg
, vol.131
, pp. 1227-1232
-
-
Liu, D.1
Wu, Z.X.2
Pan, X.M.3
-
9
-
-
79351469598
-
Pullout strength of pedicle screws with cement augmentation in severe osteoporosis: A comparative study between cannulated screws with cement injection and solid screws with cement pre-filling
-
Chen L. H., Tai C. L., Lee D. M. et al. Pullout strength of pedicle screws with cement augmentation in severe osteoporosis: a comparative study between cannulated screws with cement injection and solid screws with cement pre-filling. BMC Musculoskelet Disord: 2011; 12 33
-
(2011)
BMC Musculoskelet Disord
, vol.12
, pp. 33
-
-
Chen, L.H.1
Tai, C.L.2
Lee, D.M.3
-
10
-
-
56349095102
-
Assessment of different screw augmentation techniques and screw designs in osteoporotic spines
-
Becker S., Chavanne A., Spitaler R. et al. Assessment of different screw augmentation techniques and screw designs in osteoporotic spines. Eur Spine J: 2008; 17 1462 1469
-
(2008)
Eur Spine J
, vol.17
, pp. 1462-1469
-
-
Becker, S.1
Chavanne, A.2
Spitaler, R.3
-
11
-
-
84874193890
-
-
[Anonym] Im Internet: (Internetpräsenz des InEK mit Zugriff auf das Kalkulationshandbuch und den DRG-Definitionshandbüchern); Stand: 30.11.2011
-
[Anonym] Im Internet: http://www.g-drg.de (Internetpräsenz des InEK mit Zugriff auf das Kalkulationshandbuch und den DRG- Definitionshandbüchern); Stand: 30.11.2011
-
-
-
-
12
-
-
34247637260
-
Primary pedicle screw augmentation in osteoporotic lumbar vertebrae: Biomechanical analysis of pedicle fixation strength
-
DOI 10.1097/01.brs.0000261566.38422.40, PII 0000763220070501000006
-
Burval D. J., McLain R. F., Milks R. et al. Primary pedicle screw augmentation in osteoporotic lumbar vertebrae: biomechanical analysis of pedicle fixation strength. Spine: 2007; 32 1077 1083 (Pubitemid 46685984)
-
(2007)
Spine
, vol.32
, Issue.10
, pp. 1077-1083
-
-
Burval, D.J.1
McLain, R.F.2
Milks, R.3
Inceoglu, S.4
-
13
-
-
77954458466
-
Zementverteilung bei Vertebroplastieschrauben unterschiedlichen Designs
-
Kafchitsas K., Geiger F., Rauschmann M. et al. Zementverteilung bei Vertebroplastieschrauben unterschiedlichen Designs. Orthopäde: 2010; 39 679 686
-
(2010)
Orthopäde
, vol.39
, pp. 679-686
-
-
Kafchitsas, K.1
Geiger, F.2
Rauschmann, M.3
-
14
-
-
0028314201
-
Repair of failed transpedicle screw fixation: A biomechanical study comparing polymethylmethacrylate, milled bone, and matchstick bone reconstruction
-
Pfeifer B. A., Krag M. H., Johnson C. Repair of failed transpedicle screw fixation. A biomechanical study comparing polymethylmethacrylate, milled bone, and matchstick bone reconstruction. Spine: 1994; 19 350 353 (Pubitemid 24071120)
-
(1994)
Spine
, vol.19
, Issue.3
, pp. 350-353
-
-
Pfeifer, B.A.1
Krag, M.H.2
Johnson, C.3
-
15
-
-
3042742564
-
Augmentation of pedicle screw fixation strength using an injectable calcium phosphate cement as a function of injection timing and method
-
Renner S. M., Lim T. H., Kim W. J. et al. Augmentation of pedicle screw fixation strength using an injectable calcium phosphate cement as a function of injection timing and method. Spine: 2004; 29 E212 E216
-
(2004)
Spine
, vol.29
-
-
Renner, S.M.1
Lim, T.H.2
Kim, W.J.3
-
16
-
-
0036846092
-
Ex vivo biomechanical comparison of hydroxyapatite and polymethylmethacrylate cements for use with vertebroplasty
-
Belkoff S. M., Mathis J. M., Jasper L. E. Ex vivo biomechanical comparison of hydroxyapatite and polymethylmethacrylate cements for use with vertebroplasty. Am J Neuroradiol: 2002; 23 1647 1651 (Pubitemid 35304096)
-
(2002)
American Journal of Neuroradiology
, vol.23
, Issue.10
, pp. 1647-1651
-
-
Belkoff, S.M.1
Mathis, J.M.2
Jasper, L.E.3
-
17
-
-
0032143033
-
Revision of failed pedicle screws using hydroxyapatite cement: A biomechanical analysis
-
DOI 10.1097/00007632-199808010-00008
-
Yerby S. A., Toh E., McLain R. F. Revision of failed pedicle screws using hydroxyapatite cement. A biomechanical analysis. Spine: 1998; 23 1657 1661 (Pubitemid 28433864)
-
(1998)
Spine
, vol.23
, Issue.15
, pp. 1657-1661
-
-
Yerby, S.A.1
Toh, E.2
McLain, R.F.3
-
18
-
-
84863737397
-
Vergleich klinischer und radiologischer Daten bei der Behandlung von Patienten mit osteoporotischen Wirbelkörper-Kompressionsfrakturen mit Radiofrequenz-Kyphoplastie oder mit Ballon-Kyphoplastie
-
Pflugmacher R., Bornemann R., Koch E. M. et al. Vergleich klinischer und radiologischer Daten bei der Behandlung von Patienten mit osteoporotischen Wirbelkörper-Kompressionsfrakturen mit Radiofrequenz-Kyphoplastie oder mit Ballon-Kyphoplastie. Z Orthop Unfall: 2012; 150 56 61
-
(2012)
Z Orthop Unfall
, vol.150
, pp. 56-61
-
-
Pflugmacher, R.1
Bornemann, R.2
Koch, E.M.3
-
19
-
-
29144435629
-
Vertebroplastie und kyphoplastie bei osteoporotischen wirbelkö rperfrakturen - Eine prospektive analyse der einjahresergebnisse
-
DOI 10.1055/s-2005-858631
-
Pflugmacher R., Kandziora F., Schröder R. et al. Vertebroplastie und Kyphoplastie bei osteoporotischen Wirbelkörperfrakturen - Eine prospektive Analyse der Einjahresergebnisse. Röfo: 2005; 177 1670 1676 (Pubitemid 41806578)
-
(2005)
RoFo Fortschritte auf dem Gebiet der Rontgenstrahlen und der Bildgebenden Verfahren
, vol.177
, Issue.12
, pp. 1670-1676
-
-
Pflugmacher, R.1
Kandziora, F.2
Schroder, R.3
Schleicher, P.4
Scholz, M.5
Schnake, K.6
Haas, N.7
Khodadadyan-Klostermann, C.8
-
20
-
-
79959604919
-
Pulmonary cement embolism during cement augmentation of pedicle screw fixation: A case report
-
Akinola B., Lutchman L., Barker P. et al. Pulmonary cement embolism during cement augmentation of pedicle screw fixation: a case report. J Orthop Surg (Hong Kong): 2010; 18 364 366
-
(2010)
J Orthop Surg (Hong Kong)
, vol.18
, pp. 364-366
-
-
Akinola, B.1
Lutchman, L.2
Barker, P.3
-
21
-
-
77952392987
-
Pulmonary cement embolism after augmentation of pedicle screws with bone cement
-
Röllinghoff M., Siewe J., Eysel P. et al. Pulmonary cement embolism after augmentation of pedicle screws with bone cement. Acta Orthopaedica Belgica: 2010; 76 269 273
-
(2010)
Acta Orthopaedica Belgica
, vol.76
, pp. 269-273
-
-
Röllinghoff, M.1
Siewe, J.2
Eysel, P.3
|