메뉴 건너뛰기




Volumn 40, Issue 6, 2014, Pages 633-639

Effect of splinting in accuracy of two implant impression techniques

Author keywords

Dental implants; Dental material; Impression materials; Impression techniques; Splinting material

Indexed keywords

BIOMEDICAL AND DENTAL MATERIALS; DENTAL MATERIAL; POLYVINYL DERIVATIVE; SILOXANE; TITANIUM; TOOTH IMPLANT; VINYL POLYSILOXANE;

EID: 84918832146     PISSN: 01606972     EISSN: 15481336     Source Type: Journal    
DOI: 10.1563/AAID-JOI-D-12-00198     Document Type: Article
Times cited : (18)

References (22)
  • 1
    • 0024741319 scopus 로고
    • Preventing and resolving complications with osseointegrated implants
    • Balshi TJ. Preventing and resolving complications with osseointegrated implants. Dent Clin North Am. 1989;33:821-868.
    • (1989) Dent Clin North Am , vol.33 , pp. 821-868
    • Balshi, T.J.1
  • 2
    • 77954144133 scopus 로고    scopus 로고
    • Design of a custom angled abutment for dental implants using computer-aided design and nonlinear finite element analysis
    • Wu T, Liao W, Dai N, Tang C. Design of a custom angled abutment for dental implants using computer-aided design and nonlinear finite element analysis. J Biomech. 2010:43:1941-1946.
    • (2010) J Biomech , vol.43 , pp. 1941-1946
    • Wu, T.1    Liao, W.2    Dai, N.3    Tang, C.4
  • 3
    • 77953273784 scopus 로고    scopus 로고
    • Paramenters of passive fit using a new technique to mill implant-supported superstructures: An in vitro study of a novel three-dimensional force measurement-misfit method
    • Tahmaseb A, Van de Weijden JJ, Mercellis P, De Clerck R, Wismeijer D. Paramenters of passive fit using a new technique to mill implant-supported superstructures: an in vitro study of a novel three-dimensional force measurement-misfit method. Int J Oral Maxillofac Implants. 2010;25:247-257.
    • (2010) Int J Oral Maxillofac Implants , vol.25 , pp. 247-257
    • Tahmaseb, A.1    Van De Weijden, J.J.2    Mercellis, P.3    De Clerck, R.4    Wismeijer, D.5
  • 4
    • 3242775440 scopus 로고    scopus 로고
    • Contemporary all-ceramic fixed partial dentures: A review
    • Raigrodski AJ. Contemporary all-ceramic fixed partial dentures: a review. Dent Clin North Am. 2004;48:531-544.
    • (2004) Dent Clin North Am , vol.48 , pp. 531-544
    • Raigrodski, A.J.1
  • 5
    • 27244442763 scopus 로고    scopus 로고
    • A panorama of dental CAD/CAM restorative systems
    • Liu PR. A panorama of dental CAD/CAM restorative systems. Compend Contin Educ Dent. 2005;26:507-508.
    • (2005) Compend Contin Educ Dent , vol.26 , pp. 507-508
    • Liu, P.R.1
  • 7
    • 58149241172 scopus 로고    scopus 로고
    • The accuracy of three impression transfer techniques for implant supported prostheses
    • Dullabh HD, Sykes LM. The accuracy of three impression transfer techniques for implant supported prostheses. SADJ. 2008; 63:458-465.
    • (2008) SADJ , vol.63 , pp. 458-465
    • Dullabh, H.D.1    Sykes, L.M.2
  • 8
    • 0034132548 scopus 로고    scopus 로고
    • Accuracy of three polyvinyl siloxane putty-wash impression techniques
    • Nissan J, Laufer B-Z, Brosh T, Assif D. Accuracy of three polyvinyl siloxane putty-wash impression techniques. J Prosthet Dent. 2000;83:161-165.
    • (2000) J Prosthet Dent , vol.83 , pp. 161-165
    • Nissan, J.1    Laufer, B.-Z.2    Brosh, T.3    Assif, D.4
  • 10
    • 0027597615 scopus 로고
    • Evaluation of three impression techniques for osseointegrated oral implants
    • Interregui JA, Aquilino SA, Ryther JS, Lund PS. Evaluation of three impression techniques for osseointegrated oral implants. J Prosthet Dent. 1993;69:503-509.
    • (1993) J Prosthet Dent , vol.69 , pp. 503-509
    • Interregui, J.A.1    Aquilino, S.A.2    Ryther, J.S.3    Lund, P.S.4
  • 11
    • 0030237874 scopus 로고    scopus 로고
    • Prosthesis misfit and marginal bone loss in edentulous implant patients
    • Jemt T, Book K. Prosthesis misfit and marginal bone loss in edentulous implant patients. Int J Oral Maxillofac Implants. 1996;11: 620-625.
    • (1996) Int J Oral Maxillofac Implants , vol.11 , pp. 620-625
    • Jemt, T.1    Book, K.2
  • 12
    • 0027620268 scopus 로고
    • The accuracy of six impression techniques for osseointegrated implants
    • Barrett MG, de Rijk WG, Burgess JO. The accuracy of six impression techniques for osseointegrated implants. J Prosthodont. 1993;2:75-82.
    • (1993) J Prosthodont , vol.2 , pp. 75-82
    • Barrett, M.G.1    De Rijk, W.G.2    Burgess, J.O.3
  • 14
    • 0025622921 scopus 로고
    • The accuracy of implant master casts constructed from transfer impressions
    • Humphries RM, Yaman P, Bloem TJ. The accuracy of implant master casts constructed from transfer impressions. Int J Oral Maxillofac Implants. 1990;5:331-336.
    • (1990) Int J Oral Maxillofac Implants , vol.5 , pp. 331-336
    • Humphries, R.M.1    Yaman, P.2    Bloem, T.J.3
  • 15
    • 0025412492 scopus 로고
    • An evaluation of impression techniques for osseointegrated implants
    • Spector MR, Donovan TE, Nicholls JI: An evaluation of impression techniques for osseointegrated implants. J Prosthet Dent. 1990;63:444-447.
    • (1990) J Prosthet Dent , vol.63 , pp. 444-447
    • Spector, M.R.1    Donovan, T.E.2    Nicholls, J.I.3
  • 17
    • 38949213982 scopus 로고    scopus 로고
    • Effect of subgingival depth of implant placement on the dimensional accuracy of the implant impression: An in vitro study
    • Lee H, Ercoli C, Funkenbusch PD, Feng C. Effect of subgingival depth of implant placement on the dimensional accuracy of the implant impression: an in vitro study. J Prosthet Dent. 2008;99:107-113.
    • (2008) J Prosthet Dent , vol.99 , pp. 107-113
    • Lee, H.1    Ercoli, C.2    Funkenbusch, P.D.3    Feng, C.4
  • 18
    • 84864283529 scopus 로고    scopus 로고
    • Evaluation of impression accuracy for a four-implant mandibular model - a digital approach
    • Stimmelmayer M, Erdelt K, Gu[[amp]]die;th JF, Happe A, Beuer F. Evaluation of impression accuracy for a four-implant mandibular model - a digital approach. Clin Oral Invest. 2012;16:1137-1142.
    • (2012) Clin Oral Invest , vol.16 , pp. 1137-1142
    • Stimmelmayer, M.1    Erdelt, K.2    Güth, J.F.3    Happe, A.4    Beuer, F.5
  • 19
    • 2342418510 scopus 로고    scopus 로고
    • Cervieri. Evaluation of the accuracy of 3 transfers techniques for implantsupported prostheses with multiple abutments
    • Naconecy MM, Teixeira ER, Shinkai RS, Frasca LC, Cervieri. Evaluation of the accuracy of 3 transfers techniques for implantsupported prostheses with multiple abutments. Int J Oral Maxillofac Implants. 2004;19:192-198.
    • (2004) Int J Oral Maxillofac Implants , vol.19 , pp. 192-198
    • Naconecy, M.M.1    Teixeira, E.R.2    Shinkai, R.S.3    Frasca, L.C.4
  • 21
    • 84860242399 scopus 로고    scopus 로고
    • Accuracy of implant casts generated with splinted and non-splinted impression techniques for edentulous patients: An optical scanning study
    • Papaspyridakos P, Benic GI, Hogsett VL, White GS, Lal K, Gallucci GO. Accuracy of implant casts generated with splinted and non-splinted impression techniques for edentulous patients: an optical scanning study. Clin Oral Implants Res. 2012;23:676-681.
    • (2012) Clin Oral Implants Res , vol.23 , pp. 676-681
    • Papaspyridakos, P.1    Benic, G.I.2    Hogsett, V.L.3    White, G.S.4    Lal, K.5    Gallucci, G.O.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.