-
1
-
-
0031010530
-
Pregnancy toxaemia in the ewe
-
Andrews A. Pregnancy toxaemia in the ewe. In Pract. 1997, 19:306-312.
-
(1997)
In Pract.
, vol.19
, pp. 306-312
-
-
Andrews, A.1
-
2
-
-
84908219488
-
Statistical methods for assessing agreement between two methods of clinical measurement
-
Bland J.M., Altman D.G. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986, 1:307-310.
-
(1986)
Lancet
, vol.1
, pp. 307-310
-
-
Bland, J.M.1
Altman, D.G.2
-
3
-
-
78650806344
-
Treatment and control of peri-parturient metabolic diseases: Pregnancy toxemia, hypocalcemia, hypomagnesemia
-
Brozos C., Mavrogianni V.S., Fthenakis G.C. Treatment and control of peri-parturient metabolic diseases: Pregnancy toxemia, hypocalcemia, hypomagnesemia. Vet. Clin. North Am. Food Anim. Pract. 2011, 27:105-113.
-
(2011)
Vet. Clin. North Am. Food Anim. Pract.
, vol.27
, pp. 105-113
-
-
Brozos, C.1
Mavrogianni, V.S.2
Fthenakis, G.C.3
-
4
-
-
0034029245
-
Evaluation of an electrochemical sensor for measuring blood ketones
-
Byrne H.A., Tieszen K.L., Hollis S., Dornan T.L., New J.P. Evaluation of an electrochemical sensor for measuring blood ketones. Diabetes Care 2000, 23:500-503.
-
(2000)
Diabetes Care
, vol.23
, pp. 500-503
-
-
Byrne, H.A.1
Tieszen, K.L.2
Hollis, S.3
Dornan, T.L.4
New, J.P.5
-
5
-
-
8344284385
-
Evaluation and use of three cowside tests for detection of subclinical ketosis in early postpartum cows
-
Carrier J., Stewart S., Godden S., Fetrow J., Rapnicki P. Evaluation and use of three cowside tests for detection of subclinical ketosis in early postpartum cows. J. Dairy Sci. 2004, 87:3725-3735.
-
(2004)
J. Dairy Sci.
, vol.87
, pp. 3725-3735
-
-
Carrier, J.1
Stewart, S.2
Godden, S.3
Fetrow, J.4
Rapnicki, P.5
-
6
-
-
84879287856
-
Short communication: Evaluation of the accuracy of an electronic on-farm test to quantify blood beta-hydroxybutyrate concentration in dairy goats
-
Doré V., Dubuc J., Belanger A.M., Buczinski S. Short communication: Evaluation of the accuracy of an electronic on-farm test to quantify blood beta-hydroxybutyrate concentration in dairy goats. J. Dairy Sci. 2013, 96:4505-4507.
-
(2013)
J. Dairy Sci.
, vol.96
, pp. 4505-4507
-
-
Doré, V.1
Dubuc, J.2
Belanger, A.M.3
Buczinski, S.4
-
7
-
-
84876724376
-
-
European Medicines Agency, London, UK. Accessed June, 25, 2014.
-
EMEA (European Medicines Agency). 2011. Guidelines on bioanalytical method validation. European Medicines Agency, London, UK. Accessed June, 25, 2014. http://www.ema.europa.eu/docs/en_GB/document_library/Scientific_guideline/2011/08/WC500109686.pdf.
-
(2011)
Guidelines on bioanalytical method validation
-
-
-
8
-
-
2842534748
-
New aspects of ketone bodies in energy metabolism of dairy cows: A review
-
Holtenius P., Holtenius K. New aspects of ketone bodies in energy metabolism of dairy cows: A review. Zentralbl. Veterinarmed. A 1996, 43:579-587.
-
(1996)
Zentralbl. Veterinarmed. A
, vol.43
, pp. 579-587
-
-
Holtenius, P.1
Holtenius, K.2
-
9
-
-
58049172910
-
Metabolic profiles in goat does in late pregnancy with and without subclinical pregnancy toxemia
-
Ismail Z.A., Al-Majali A.M., Amireh F., Al-Rawashdeh O.F. Metabolic profiles in goat does in late pregnancy with and without subclinical pregnancy toxemia. Vet. Clin. Pathol. 2008, 37:434-437.
-
(2008)
Vet. Clin. Pathol.
, vol.37
, pp. 434-437
-
-
Ismail, Z.A.1
Al-Majali, A.M.2
Amireh, F.3
Al-Rawashdeh, O.F.4
-
10
-
-
84888040195
-
Comparison of 2 electronic cowside tests to detect subclinical ketosis in dairy cows and the influence of the temperature and type of blood sample on the test results
-
Iwersen M., Klein-Jöbstl D., Pichler M., Roland L., Fidlschuster B., Schwendenwein I., Drillich M. Comparison of 2 electronic cowside tests to detect subclinical ketosis in dairy cows and the influence of the temperature and type of blood sample on the test results. J. Dairy Sci. 2013, 96:7719-7730.
-
(2013)
J. Dairy Sci.
, vol.96
, pp. 7719-7730
-
-
Iwersen, M.1
Klein-Jöbstl, D.2
Pichler, M.3
Roland, L.4
Fidlschuster, B.5
Schwendenwein, I.6
Drillich, M.7
-
11
-
-
79955097657
-
Latent class evaluation of a milk test, a urine test, and the fat-to-protein percentage ratio in milk to diagnose ketosis in dairy cows
-
Krogh M.A., Toft N., Enevoldsen C. Latent class evaluation of a milk test, a urine test, and the fat-to-protein percentage ratio in milk to diagnose ketosis in dairy cows. J. Dairy Sci. 2011, 94:2360-2367.
-
(2011)
J. Dairy Sci.
, vol.94
, pp. 2360-2367
-
-
Krogh, M.A.1
Toft, N.2
Enevoldsen, C.3
-
12
-
-
0035034235
-
Relationships of glucose concentrations in capillary whole-blood, venous whole-blood and venous plasma
-
Kuwa K., Nakayama T., Hoshino T., Tominaga M. Relationships of glucose concentrations in capillary whole-blood, venous whole-blood and venous plasma. Clin. Chim. Acta 2001, 307:187-192.
-
(2001)
Clin. Chim. Acta
, vol.307
, pp. 187-192
-
-
Kuwa, K.1
Nakayama, T.2
Hoshino, T.3
Tominaga, M.4
-
13
-
-
84918834786
-
Chronic weight loss
-
Wiley-Blackwell, Oxford, UK, J. Matthews (Ed.)
-
Matthews J. Chronic weight loss. Diseases of the Goat 2009, 123-147. Wiley-Blackwell, Oxford, UK. 3rd. J. Matthews (Ed.).
-
(2009)
Diseases of the Goat
, pp. 123-147
-
-
Matthews, J.1
-
14
-
-
40849112973
-
Reflections on the causes and the diagnosis of peri-parturient losses of ewes
-
Mavrogianni V.S., Brozos C. Reflections on the causes and the diagnosis of peri-parturient losses of ewes. Small Rumin. Res. 2008, 76:77-82.
-
(2008)
Small Rumin. Res.
, vol.76
, pp. 77-82
-
-
Mavrogianni, V.S.1
Brozos, C.2
-
15
-
-
0036183806
-
Effects of sample handling, processing, storage, and hemolysis on measurements of key energy metabolites in ovine blood
-
Morris J.D., Fernandez J.M., Chapa A.M., Gentry L.R., Thorn K.E., Weick T.M. Effects of sample handling, processing, storage, and hemolysis on measurements of key energy metabolites in ovine blood. Small Rumin. Res. 2002, 43:157-166.
-
(2002)
Small Rumin. Res.
, vol.43
, pp. 157-166
-
-
Morris, J.D.1
Fernandez, J.M.2
Chapa, A.M.3
Gentry, L.R.4
Thorn, K.E.5
Weick, T.M.6
-
16
-
-
84882558458
-
Diseases of the gastrointestinal system
-
Elsevier Inc., Maryland Heights, MO, D.G. Pugh, A.N. Baird (Eds.)
-
Navarre C.B., Baird A.N., Pugh D.G. Diseases of the gastrointestinal system. Sheep and Goat Medicine 2012, 71-105. Elsevier Inc., Maryland Heights, MO. 2nd. D.G. Pugh, A.N. Baird (Eds.).
-
(2012)
Sheep and Goat Medicine
, pp. 71-105
-
-
Navarre, C.B.1
Baird, A.N.2
Pugh, D.G.3
-
17
-
-
34249880434
-
Hydroxybutyrate near-patient testing to evaluate a new end-point for intravenous insulin therapy in the treatment of diabetic ketoacidosis in children
-
Noyes K.J., Crofton P., Bath L.E., Holmes A., Stark L., Oxley C.D., Kelnar C.J. Hydroxybutyrate near-patient testing to evaluate a new end-point for intravenous insulin therapy in the treatment of diabetic ketoacidosis in children. Pediatr. Diabetes 2007, 8:150-156.
-
(2007)
Pediatr. Diabetes
, vol.8
, pp. 150-156
-
-
Noyes, K.J.1
Crofton, P.2
Bath, L.E.3
Holmes, A.4
Stark, L.5
Oxley, C.D.6
Kelnar, C.J.7
-
18
-
-
84858149045
-
Evaluation of Precision Xceed® meter for on-site monitoring of blood beta-hydroxybutyric acid and glucose concentrations in dairy sheep
-
Panousis N., Brozos C., Karagiannis I., Giadinis N.D., Lafi S., Kritsepi-Konstantinou M. Evaluation of Precision Xceed® meter for on-site monitoring of blood beta-hydroxybutyric acid and glucose concentrations in dairy sheep. Res. Vet. Sci. 2012, 93:435-439.
-
(2012)
Res. Vet. Sci.
, vol.93
, pp. 435-439
-
-
Panousis, N.1
Brozos, C.2
Karagiannis, I.3
Giadinis, N.D.4
Lafi, S.5
Kritsepi-Konstantinou, M.6
-
19
-
-
84894055924
-
Thresholds of whole-blood β-hydroxybutyrate and glucose concentrations measured with an electronic hand-held device to identify ovine hyperketonemia
-
Pichler M., Damberger A., Schwendenwein I., Gasteiner J., Drillich M., Iwersen M. Thresholds of whole-blood β-hydroxybutyrate and glucose concentrations measured with an electronic hand-held device to identify ovine hyperketonemia. J. Dairy Sci. 2014, 97:1388-1399.
-
(2014)
J. Dairy Sci.
, vol.97
, pp. 1388-1399
-
-
Pichler, M.1
Damberger, A.2
Schwendenwein, I.3
Gasteiner, J.4
Drillich, M.5
Iwersen, M.6
-
20
-
-
0023706735
-
Storage of whole blood: Effect of temperature on the measured concentration of analytes in serum
-
Rehak N.N., Chiang B.T. Storage of whole blood: Effect of temperature on the measured concentration of analytes in serum. Clin. Chem. 1988, 34:2111-2114.
-
(1988)
Clin. Chem.
, vol.34
, pp. 2111-2114
-
-
Rehak, N.N.1
Chiang, B.T.2
-
21
-
-
0034223503
-
Pregnancy toxemia of ewes, does, and beef cows
-
Rook J.S. Pregnancy toxemia of ewes, does, and beef cows. Vet. Clin. North Am. Food Anim. Pract. 2000, 16:293-317.
-
(2000)
Vet. Clin. North Am. Food Anim. Pract.
, vol.16
, pp. 293-317
-
-
Rook, J.S.1
-
22
-
-
40849113755
-
Pregnancy toxaemia
-
Blackwell Publishing Ltd., Oxford, UK, I.D. Aitken (Ed.)
-
Sargison N.D. Pregnancy toxaemia. Diseases of Sheep 2007, 359-363. Blackwell Publishing Ltd., Oxford, UK. 4th. I.D. Aitken (Ed.).
-
(2007)
Diseases of Sheep
, pp. 359-363
-
-
Sargison, N.D.1
-
23
-
-
84894050226
-
Probenahme, Laboruntersuchungen und invasive diagnostische Maßnahmen. Untersuchung des Blutes
-
Parey, Stuttgart, Germany, W. Baumgartner (Ed.)
-
Schwendenwein I. Probenahme, Laboruntersuchungen und invasive diagnostische Maßnahmen. Untersuchung des Blutes. Klinische Propädeutik der Haus- und Heimtiere 2009, 432-461. Parey, Stuttgart, Germany. 7th. W. Baumgartner (Ed.).
-
(2009)
Klinische Propädeutik der Haus- und Heimtiere
, pp. 432-461
-
-
Schwendenwein, I.1
-
24
-
-
84890142416
-
Metabolic and nutritional diseases
-
CABI International, Wallingford, UK, A. Cannas, G. Pulina (Eds.)
-
Stelletta C., Gianésella M., Morgante M. Metabolic and nutritional diseases. Dairy Goats Feeding and Nutrition 2008, 263-283. CABI International, Wallingford, UK. 1st. A. Cannas, G. Pulina (Eds.).
-
(2008)
Dairy Goats Feeding and Nutrition
, pp. 263-283
-
-
Stelletta, C.1
Gianésella, M.2
Morgante, M.3
-
25
-
-
0023890867
-
Measuring the accuracy of diagnostic systems
-
Swets J.A. Measuring the accuracy of diagnostic systems. Science 1988, 240:1285-1293.
-
(1988)
Science
, vol.240
, pp. 1285-1293
-
-
Swets, J.A.1
-
26
-
-
78049305594
-
Use of a hand-held meter for detecting subclinical ketosis in dairy cows
-
Voyvoda H., Erdogan H. Use of a hand-held meter for detecting subclinical ketosis in dairy cows. Res. Vet. Sci. 2010, 89:344-351.
-
(2010)
Res. Vet. Sci.
, vol.89
, pp. 344-351
-
-
Voyvoda, H.1
Erdogan, H.2
-
27
-
-
16244366026
-
Index for rating diagnostic tests
-
Youden W.J. Index for rating diagnostic tests. Cancer 1950, 3:32-35.
-
(1950)
Cancer
, vol.3
, pp. 32-35
-
-
Youden, W.J.1
-
28
-
-
77956194339
-
Alternative sampling site for blood glucose testing in cats: Giving the ears a rest
-
Zeugswetter F.K., Rebuzzi L., Karlovits S. Alternative sampling site for blood glucose testing in cats: Giving the ears a rest. J. Feline Med. Surg. 2010, 12:710-713.
-
(2010)
J. Feline Med. Surg.
, vol.12
, pp. 710-713
-
-
Zeugswetter, F.K.1
Rebuzzi, L.2
Karlovits, S.3
-
29
-
-
0031778391
-
Effect of serum-clot contact time on clinical chemistry laboratory results
-
Zhang D.J., Elswick R.K., Miller W.G., Bailey J.L. Effect of serum-clot contact time on clinical chemistry laboratory results. Clin. Chem. 1998, 44:1325-1333.
-
(1998)
Clin. Chem.
, vol.44
, pp. 1325-1333
-
-
Zhang, D.J.1
Elswick, R.K.2
Miller, W.G.3
Bailey, J.L.4
|