메뉴 건너뛰기




Volumn 89, Issue 3, 2010, Pages 344-351

Use of a hand-held meter for detecting subclinical ketosis in dairy cows

Author keywords

Hydroxybutyrate; Cows; Hand held meter; Subclinical ketosis

Indexed keywords

3 HYDROXYBUTYRIC ACID; GLUCOSE;

EID: 78049305594     PISSN: 00345288     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.rvsc.2010.04.007     Document Type: Article
Times cited : (62)

References (53)
  • 1
    • 78049287476 scopus 로고    scopus 로고
    • Anonymous, MediSense Optium™ Blood Glucose Test Strip Instructions for Use
    • Anonymous, 2005. MediSense Optium™ Blood Glucose Test Strip Instructions for Use.
    • (2005)
  • 2
    • 78049232104 scopus 로고    scopus 로고
    • Anonymous, a. Abbott Optium Xceed Diabetes Monitoring System. User's Guide
    • Anonymous, 2006a. Abbott Optium Xceed Diabetes Monitoring System. User's Guide http://www.abbottdiabetescare.com/.
    • (2006)
  • 3
    • 78049290662 scopus 로고    scopus 로고
    • Anonymous, b. MediSense Glucose and Ketone Control Solutions
    • Anonymous, 2006b. MediSense Glucose and Ketone Control Solutions.
    • (2006)
  • 4
    • 78049310608 scopus 로고    scopus 로고
    • Anonymous,c. Optium™ Blood β-Ketone Test Strip Instructions For Use
    • Anonymous, 2006c. Optium™ Blood β-Ketone Test Strip Instructions For Use.
    • (2006)
  • 5
    • 78049242271 scopus 로고    scopus 로고
    • Evaluation of MediSense SoftSense Blood Glucose Sensor. Medical Device Agency Evaluation Report, MDA 02002
    • Batki, A.D., Nayyar, P., Holder, R., Thomason, H.L., Thorpe, G.H.G., 2002. Evaluation of MediSense SoftSense Blood Glucose Sensor. Medical Device Agency Evaluation Report, MDA 02002.
    • (2002)
    • Batki, A.D.1    Nayyar, P.2    Holder, R.3    Thomason, H.L.4    Thorpe, G.H.G.5
  • 6
    • 7544251779 scopus 로고    scopus 로고
    • Point of care blood ketone testing of diabetic patients in the emergency department
    • Bektas F., Eray O., Sari R., Akbas H. Point of care blood ketone testing of diabetic patients in the emergency department. Endocrine Research 2004, 30:395-402.
    • (2004) Endocrine Research , vol.30 , pp. 395-402
    • Bektas, F.1    Eray, O.2    Sari, R.3    Akbas, H.4
  • 7
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland J.M., Altman D.G. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986, 1(8476):307-310.
    • (1986) Lancet , vol.1 , Issue.8476 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 8
    • 0043064332 scopus 로고    scopus 로고
    • Lipids and ketones
    • Academic Press, San Diego, J.J. Kaneko, J.W. Harvey, M.L. Bruss (Eds.)
    • Bruss M.L. Lipids and ketones. Clinical Biochemistry of Domestic Animals 1997, 83-117. Academic Press, San Diego. fifth ed. J.J. Kaneko, J.W. Harvey, M.L. Bruss (Eds.).
    • (1997) Clinical Biochemistry of Domestic Animals , pp. 83-117
    • Bruss, M.L.1
  • 9
    • 0034029245 scopus 로고    scopus 로고
    • Evaluation of an electrochemical sensor for measuring blood ketones
    • Byrne H.A., Tieszen K.L., Hollis S., Dornan T.L., New J.P. Evaluation of an electrochemical sensor for measuring blood ketones. Diabetes Care 2000, 23:500-503.
    • (2000) Diabetes Care , vol.23 , pp. 500-503
    • Byrne, H.A.1    Tieszen, K.L.2    Hollis, S.3    Dornan, T.L.4    New, J.P.5
  • 10
    • 8344284385 scopus 로고    scopus 로고
    • Evaluation and use of three cowside tests for detection of subclinical ketosis in early postpartum cows
    • Carrier J., Stewart S., Godden S., Fetrow J., Rapnicki P. Evaluation and use of three cowside tests for detection of subclinical ketosis in early postpartum cows. Journal of Dairy Science 2004, 87:3725-3735.
    • (2004) Journal of Dairy Science , vol.87 , pp. 3725-3735
    • Carrier, J.1    Stewart, S.2    Godden, S.3    Fetrow, J.4    Rapnicki, P.5
  • 11
    • 0036597679 scopus 로고    scopus 로고
    • Evaluation of a new handheld biosensor for point-of-care testing of whole blood betahydroxybutyrate concentration
    • Chiu R.W., Ho C.S., Tong S.F., Ng K.F., Lam C.W. Evaluation of a new handheld biosensor for point-of-care testing of whole blood betahydroxybutyrate concentration. Hong Kong Medical Journal 2002, 8:172-176.
    • (2002) Hong Kong Medical Journal , vol.8 , pp. 172-176
    • Chiu, R.W.1    Ho, C.S.2    Tong, S.F.3    Ng, K.F.4    Lam, C.W.5
  • 12
    • 0014073294 scopus 로고
    • The distribution of sodium, potassium and glucose in the blood of some mammals
    • Coldman M.F., Good W. The distribution of sodium, potassium and glucose in the blood of some mammals. Comparative Biochemistry and Physiology 1967, 21:201-206.
    • (1967) Comparative Biochemistry and Physiology , vol.21 , pp. 201-206
    • Coldman, M.F.1    Good, W.2
  • 13
    • 78049241269 scopus 로고    scopus 로고
    • Clinical Evaluation of the Hand-Held Abbott Alpha TRAK™ Blood Glucose Monitoring Systems for Use with Dog and Cat Blood Samples., ALPHA-033.
    • Cozzi, M.E., Harris, C.N., Lawrence, A.J., Semon, R., Shridhara, A., Matthew, M.W., 2006. Clinical Evaluation of the Hand-Held Abbott Alpha TRAK™ Blood Glucose Monitoring Systems for Use with Dog and Cat Blood Samples., ALPHA-033. http://www.abbottanimalhealth.com/.
    • (2006)
    • Cozzi, M.E.1    Harris, C.N.2    Lawrence, A.J.3    Semon, R.4    Shridhara, A.5    Matthew, M.W.6
  • 14
    • 0021330876 scopus 로고
    • Subclinical ketosis: prevalence and associations with production and disease
    • Dohoo I.R., Martin S.W. Subclinical ketosis: prevalence and associations with production and disease. Canadian Journal of Comparative Medicine 1984, 48:1-5.
    • (1984) Canadian Journal of Comparative Medicine , vol.48 , pp. 1-5
    • Dohoo, I.R.1    Martin, S.W.2
  • 16
    • 78049272047 scopus 로고    scopus 로고
    • Minimizing subclinical metabolic diseases. In: Proceedings of Tri-State Dairy Nutrition Conference, Fort Wayne
    • Duffield, T., 2003. Minimizing subclinical metabolic diseases. In: Proceedings of Tri-State Dairy Nutrition Conference, Fort Wayne, pp. 1-14.
    • (2003) , pp. 1-14
    • Duffield, T.1
  • 17
    • 78049295809 scopus 로고    scopus 로고
    • Monitoring strategies for metabolic disease in transition dairy cows. In: Proceedings of the 23rd World Buiatrics Congress, Quebec, Canada, July 11-16, 2004
    • Duffield, T.F., 2004. Monitoring strategies for metabolic disease in transition dairy cows. In: Proceedings of the 23rd World Buiatrics Congress, Quebec, Canada, July 11-16, 2004.
    • (2004)
    • Duffield, T.F.1
  • 18
    • 78049238836 scopus 로고    scopus 로고
    • Impact of subclinical ketosis on health and performance. In: Proceedings of the North American Veterinary Conference, Orlando, Florida
    • Duffield, T., 2006. Impact of subclinical ketosis on health and performance. In: Proceedings of the North American Veterinary Conference, vol. 20, Orlando, Florida, pp. 13-16.
    • (2006) , vol.20 , pp. 13-16
    • Duffield, T.1
  • 19
    • 78049261243 scopus 로고    scopus 로고
    • Influence of concentrate feeding frequency and intrinsic factors on diurnal variations of blood metabolites in dairy cows. In: Proceedings of the 31st Annual Convention of the American Association of Bovine Practitioners, Rome, GA
    • Eicher, R., Liesegang, A., Bouchard, E., Tremblay, A., 1998. Influence of concentrate feeding frequency and intrinsic factors on diurnal variations of blood metabolites in dairy cows. In: Proceedings of the 31st Annual Convention of the American Association of Bovine Practitioners, Rome, GA, pp. 198-202.
    • (1998) , pp. 198-202
    • Eicher, R.1    Liesegang, A.2    Bouchard, E.3    Tremblay, A.4
  • 20
    • 78049304978 scopus 로고    scopus 로고
    • Blood ketone levels of young postpartum range cows increased after supplementation ceased
    • Endecott R.L., Black C.M., Notah K.A., Petersen M.K. Blood ketone levels of young postpartum range cows increased after supplementation ceased. Journal of Dairy Science 2004, 87(Suppl. 1):114.
    • (2004) Journal of Dairy Science , vol.87 , Issue.SUPPL. 1 , pp. 114
    • Endecott, R.L.1    Black, C.M.2    Notah, K.A.3    Petersen, M.K.4
  • 21
    • 78049296774 scopus 로고    scopus 로고
    • Ketose, die bedeutendste Stoffwechselerkrankung der Milchkuh, Viehwirtschaftliche Fachtagung, BAL Gumpenstein, Germany
    • Gasteiner, J., 2000. Ketose, die bedeutendste Stoffwechselerkrankung der Milchkuh, vol. 27. Viehwirtschaftliche Fachtagung, BAL Gumpenstein, Germany.
    • (2000) , vol.27
    • Gasteiner, J.1
  • 22
    • 0031989599 scopus 로고    scopus 로고
    • Evaluation of five cowside tests for use with milk to detect subclinical ketosis in dairy cows
    • Geishauser T., Leslie K., Kelton D., Duffield T. Evaluation of five cowside tests for use with milk to detect subclinical ketosis in dairy cows. Journal of Dairy Science 1998, 81:438-443.
    • (1998) Journal of Dairy Science , vol.81 , pp. 438-443
    • Geishauser, T.1    Leslie, K.2    Kelton, D.3    Duffield, T.4
  • 23
    • 0034133538 scopus 로고    scopus 로고
    • Evaluation of eight cow-side ketone tests in milk for detection of subclinical ketosis in dairy cows
    • Geishauser T., Leslie K., Tenhag J., Bashiri A. Evaluation of eight cow-side ketone tests in milk for detection of subclinical ketosis in dairy cows. Journal of Dairy Science 2000, 83:296-299.
    • (2000) Journal of Dairy Science , vol.83 , pp. 296-299
    • Geishauser, T.1    Leslie, K.2    Tenhag, J.3    Bashiri, A.4
  • 25
    • 0040685598 scopus 로고
    • Indikatoren zur Beurteilung der Energiebilanz der Milchkuh
    • Gravert H.O. Indikatoren zur Beurteilung der Energiebilanz der Milchkuh. Monatshefte für Veterinarmedizin 1991, 46:536-537.
    • (1991) Monatshefte für Veterinarmedizin , vol.46 , pp. 536-537
    • Gravert, H.O.1
  • 27
    • 1842832862 scopus 로고    scopus 로고
    • Bedside ketone determination in diabetic children with hyperglycemia and ketosis in the acute care setting
    • Ham M.R., Okada P., White P.C. Bedside ketone determination in diabetic children with hyperglycemia and ketosis in the acute care setting. Pediatric Diabetes 2004, 5:39-43.
    • (2004) Pediatric Diabetes , vol.5 , pp. 39-43
    • Ham, M.R.1    Okada, P.2    White, P.C.3
  • 28
    • 0034221650 scopus 로고    scopus 로고
    • Variability characteristics and test selection in herd-level nutritional and metabolic profile testing: metabolic disorders of ruminants
    • Herdt T.H. Variability characteristics and test selection in herd-level nutritional and metabolic profile testing: metabolic disorders of ruminants. Veterinary Clinics of North America: Food Animal Practice 2000, 16:387-403.
    • (2000) Veterinary Clinics of North America: Food Animal Practice , vol.16 , pp. 387-403
    • Herdt, T.H.1
  • 29
    • 38849131323 scopus 로고    scopus 로고
    • Use of a hand-held meter for the measurement of blood beta-hydroxybutyrate in dogs and cats
    • Hoenig M., Dorfman M., Koenig A. Use of a hand-held meter for the measurement of blood beta-hydroxybutyrate in dogs and cats. Journal of Veterinary Emergency and Critical Care 2008, 18:86-87.
    • (2008) Journal of Veterinary Emergency and Critical Care , vol.18 , pp. 86-87
    • Hoenig, M.1    Dorfman, M.2    Koenig, A.3
  • 32
    • 78049278599 scopus 로고    scopus 로고
    • Ketone body measurement in dairy cows. In: Proceedings of the 24th World Buiatrics Congress, Nice, France, Ref. OS
    • Jeppesen, R., Enemark J.M.D., Enevoldsen, C., 2006. Ketone body measurement in dairy cows. In: Proceedings of the 24th World Buiatrics Congress, Nice, France, Ref. OS 43-2.
    • (2006) , vol.43 , Issue.2
    • Jeppesen, R.1    Enemark, J.M.D.2    Enevoldsen, C.3
  • 33
    • 84861478517 scopus 로고    scopus 로고
    • Sensitivity and specificity of various tests determining β-hydroxybutyrate acid in diagnosis of ketosis in cows
    • Kupczyński R., Cupok A. Sensitivity and specificity of various tests determining β-hydroxybutyrate acid in diagnosis of ketosis in cows. Electronic Journal of Polish Agricultural Universities 2007, 10(3).
    • (2007) Electronic Journal of Polish Agricultural Universities , vol.10 , Issue.3
    • Kupczyński, R.1    Cupok, A.2
  • 34
    • 0033400713 scopus 로고    scopus 로고
    • Ketone bodies: a review of physiology, pathophysiology and application of monitoring to diabetes
    • Laffel L. Ketone bodies: a review of physiology, pathophysiology and application of monitoring to diabetes. Diabetes-Metabolism Research and Reviews 1999, 15:412-426.
    • (1999) Diabetes-Metabolism Research and Reviews , vol.15 , pp. 412-426
    • Laffel, L.1
  • 35
    • 78049312074 scopus 로고    scopus 로고
    • Monitoring programs for transition dairy cows. In: Proceedings of the 26th World Buiatrics Congress, Nice, France
    • LeBlanc, S., 2006. Monitoring programs for transition dairy cows. In: Proceedings of the 26th World Buiatrics Congress, Nice, France, pp. 460-472.
    • (2006) , pp. 460-472
    • LeBlanc, S.1
  • 36
    • 0344402313 scopus 로고
    • The distribution of glucose in human blood
    • Mackay E.M. The distribution of glucose in human blood. The Journal of Biological Chemistry 1932, 97:685-688.
    • (1932) The Journal of Biological Chemistry , vol.97 , pp. 685-688
    • Mackay, E.M.1
  • 38
    • 34249880434 scopus 로고    scopus 로고
    • Hydroxybutyrate near-patient testing to evaluate a new end-point for intravenous insulin therapy in the treatment of diabetic ketoacidosis in children
    • Noyes K.J., Crofton P., Bath L.E., Holmes A., Stark L., Oxley C.D., Kelnar C.J.H. Hydroxybutyrate near-patient testing to evaluate a new end-point for intravenous insulin therapy in the treatment of diabetic ketoacidosis in children. Pediatric Diabetes 2007, 8:150-156.
    • (2007) Pediatric Diabetes , vol.8 , pp. 150-156
    • Noyes, K.J.1    Crofton, P.2    Bath, L.E.3    Holmes, A.4    Stark, L.5    Oxley, C.D.6    Kelnar, C.J.H.7
  • 40
    • 78049237525 scopus 로고    scopus 로고
    • Cowside blood BHBA testing with a hand-held "ketometer" fact sheet-version 2, 9/27/07, University of Wisconsin-Madison, School of Veterinary Medicine
    • Oetzel, G.R., McGuirk, S., 2007. Cowside blood BHBA testing with a hand-held "ketometer" fact sheet-version 2, 9/27/07, University of Wisconsin-Madison, School of Veterinary Medicine.
    • (2007)
    • Oetzel, G.R.1    McGuirk, S.2
  • 41
    • 78049287475 scopus 로고    scopus 로고
    • Evaluation of keto-test in urine and milk for the detection of subclinical ketosis in periparturient Holstein dairy cattle. In: Proceedings of the 35th Conference of the American Association of Bovine Practitioners, Rome, GA
    • Osborne, T.M., Leslie, K.E., Duffield, T., Petersson, C.S., Ten Hag, J., Okada, Y., 2002. Evaluation of keto-test in urine and milk for the detection of subclinical ketosis in periparturient Holstein dairy cattle. In: Proceedings of the 35th Conference of the American Association of Bovine Practitioners, Rome, GA, pp. 188-189.
    • (2002) , pp. 188-189
    • Osborne, T.M.1    Leslie, K.E.2    Duffield, T.3    Petersson, C.S.4    Ten Hag, J.5    Okada, Y.6
  • 42
    • 0021045350 scopus 로고
    • A new biometrical procedure for testing the equality of measurements from two different analytical methods
    • Passing H., Bablok W. A new biometrical procedure for testing the equality of measurements from two different analytical methods. Journal of Clinical Chemistry and Clinical Biochemistry 1983, 21:709-720.
    • (1983) Journal of Clinical Chemistry and Clinical Biochemistry , vol.21 , pp. 709-720
    • Passing, H.1    Bablok, W.2
  • 44
    • 78049297267 scopus 로고    scopus 로고
    • Tools for a prompt cowside diagnosis: what can be implemented by the bovine practitioner? In: Proceedings of the 24th World Buiatrics Congress, Nice, France
    • Rollin, F., 2006. Tools for a prompt cowside diagnosis: what can be implemented by the bovine practitioner? In: Proceedings of the 24th World Buiatrics Congress, Nice, France. http://www.ivis.org/proceedings/wbc/wbc2006/rollin.pdf.
    • (2006)
    • Rollin, F.1
  • 45
    • 78049245172 scopus 로고    scopus 로고
    • Precision Xceed Pro System, an advanced point-of-care system for measuring blood glucose and ketone
    • Ronald Ng. Precision Xceed Pro System, an advanced point-of-care system for measuring blood glucose and ketone. Point of Care: The Journal of Near-Patient Testing and Technology 2008, 7:161.
    • (2008) Point of Care: The Journal of Near-Patient Testing and Technology , vol.7 , pp. 161
    • Ronald, N.1
  • 46
    • 0033174351 scopus 로고    scopus 로고
    • Field method for monitoring blood glucose in beef cattle
    • Rumsey T.S., Kahl S., Elsasser T.H. Field method for monitoring blood glucose in beef cattle. Journal of Animal Science 1999, 77:2194-2200.
    • (1999) Journal of Animal Science , vol.77 , pp. 2194-2200
    • Rumsey, T.S.1    Kahl, S.2    Elsasser, T.H.3
  • 48
    • 0037402409 scopus 로고    scopus 로고
    • Analytical performance of glucometers used for routine glucose self-monitoring of diabetic patients
    • Solnica B., Naskalski J.W., Sieradzki J. Analytical performance of glucometers used for routine glucose self-monitoring of diabetic patients. Clinical Chimica Acta 2003, 331:29-35.
    • (2003) Clinical Chimica Acta , vol.331 , pp. 29-35
    • Solnica, B.1    Naskalski, J.W.2    Sieradzki, J.3
  • 49
    • 34548669886 scopus 로고    scopus 로고
    • Ketose, lipomobilisationssyndrom
    • Parey Buchverlag, Berlin, G. Dirksen, H.D. Gründer, M. Stöber (Eds.)
    • Stöber M. Ketose, lipomobilisationssyndrom. Innere Medizin und Chirurgie des Rindes 2002, 649-664. Parey Buchverlag, Berlin. fourth ed. G. Dirksen, H.D. Gründer, M. Stöber (Eds.).
    • (2002) Innere Medizin und Chirurgie des Rindes , pp. 649-664
    • Stöber, M.1
  • 51
    • 0033849382 scopus 로고    scopus 로고
    • Effects of different hematocrit levels on glucose measurements with handheld meters for point of care testing
    • Tang Z., Lee J.H., Louie R.F., Kost G.J. Effects of different hematocrit levels on glucose measurements with handheld meters for point of care testing. Archives of Pathology and Laboratory Medicine 2000, 124:1135-1140.
    • (2000) Archives of Pathology and Laboratory Medicine , vol.124 , pp. 1135-1140
    • Tang, Z.1    Lee, J.H.2    Louie, R.F.3    Kost, G.J.4
  • 53
    • 51349106240 scopus 로고    scopus 로고
    • Blood ketone testing in the clinical laboratory-technical evaluation of test-strips
    • Yoong Ng.W., Crystal Y.W.M., Jacob E. Blood ketone testing in the clinical laboratory-technical evaluation of test-strips. Singapore General Hospital Proceedings 2008, 17:88-93.
    • (2008) Singapore General Hospital Proceedings , vol.17 , pp. 88-93
    • Yoong, N.1    Crystal, Y.W.M.2    Jacob, E.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.