메뉴 건너뛰기




Volumn 130, Issue 24, 2014, Pages

Response to letter regarding article "comparison of cardiovascular magnetic resonance and single-photon emission computed tomography in women with suspected coronary artery disease from the clinical evaluation of magnetic resonance imaging in coronary heart disease (CE-MARC) trial"

Author keywords

[No Author keywords available]

Indexed keywords

CARDIOVASCULAR MAGNETIC RESONANCE; CARDIOVASCULAR MORTALITY; CORONARY ARTERY DISEASE; DIAGNOSTIC ACCURACY; DIAGNOSTIC TEST; DIAGNOSTIC TEST ACCURACY STUDY; HUMAN; INTERMETHOD COMPARISON; ISCHEMIC HEART DISEASE; LETTER; MAGNETIC RESONANCE ANGIOGRAPHY; PREDICTIVE VALUE; SINGLE PHOTON EMISSION COMPUTER TOMOGRAPHY; FEMALE; MALE; NUCLEAR MAGNETIC RESONANCE IMAGING; PROCEDURES;

EID: 84917674405     PISSN: 00097322     EISSN: 15244539     Source Type: Journal    
DOI: 10.1161/CIRCULATIONAHA.114.012784     Document Type: Letter
Times cited : (3)

References (5)
  • 1
    • 84896744476 scopus 로고    scopus 로고
    • Comparison of cardiovascular magnetic resonance and single-photon emission computed tomography in women with suspected coronary artery disease from the Clinical Evaluation of Magnetic Resonance Imaging in Coronary Heart Disease (CE-MARC) trial
    • Greenwood JP, Motwani M, Maredia N, Brown JM, Everett CC, Nixon J, Bijsterveld P, Dickinson CJ, Ball SG, Plein S. Comparison of cardiovascular magnetic resonance and single-photon emission computed tomography in women with suspected coronary artery disease from the Clinical Evaluation of Magnetic Resonance Imaging in Coronary Heart Disease (CE-MARC) trial. Circulation. 2014;129:1129-1138.
    • (2014) Circulation , vol.129 , pp. 1129-1138
    • Greenwood, J.P.1    Motwani, M.2    Maredia, N.3    Brown, J.M.4    Everett, C.C.5    Nixon, J.6    Bijsterveld, P.7    Dickinson, C.J.8    Ball, S.G.9    Plein, S.10
  • 2
    • 84861950862 scopus 로고    scopus 로고
    • CMR versus SPECT for diagnosis of coronary heart disease-authors reply
    • Greenwood JP, Brown JM, Dickinson CJ, Ball SG, Plein S. CMR versus SPECT for diagnosis of coronary heart disease -authors reply. Lancet. 2012;379:2147-2148.
    • (2012) Lancet , vol.379 , pp. 2147-2148
    • Greenwood, J.P.1    Brown, J.M.2    Dickinson, C.J.3    Ball, S.G.4    Plein, S.5
  • 4
    • 0036119696 scopus 로고    scopus 로고
    • Effects of adjustment for referral bias on the sensitivity and specificity of single photon emission computed tomography for the diagnosis of coronary artery disease
    • Miller TD, Hodge DO, Christian TF, Milavetz JJ, Bailey KR, Gibbons RJ. Effects of adjustment for referral bias on the sensitivity and specificity of single photon emission computed tomography for the diagnosis of coronary artery disease. Am J Med. 2002;112:290-297.
    • (2002) Am J Med , vol.112 , pp. 290-297
    • Miller, T.D.1    Hodge, D.O.2    Christian, T.F.3    Milavetz, J.J.4    Bailey, K.R.5    Gibbons, R.J.6
  • 5
    • 84865567606 scopus 로고    scopus 로고
    • MR-IMPACT investigators. Superior diagnostic performance of perfusion-cardiovascular magnetic resonance versus SPECT to detect coronary artery disease: The secondary endpoints of the multicenter multivendor MR-IMPACT II (Magnetic Resonance Imaging for Myocardial Perfusion Assessment in Coronary Artery Disease Trial)
    • Schwitter J, Wacker CM, Wilke N, Al-Saadi N, Sauer E, Huettle K, Schönberg SO, Debl K, Strohm O, Ahlstrom H, Dill T, Hoebel N, Simor T; MR-IMPACT investigators. Superior diagnostic performance of perfusion-cardiovascular magnetic resonance versus SPECT to detect coronary artery disease: The secondary endpoints of the multicenter multivendor MR-IMPACT II (Magnetic Resonance Imaging for Myocardial Perfusion Assessment in Coronary Artery Disease Trial). J Cardiovasc Magn Reson. 2012;14:61.
    • (2012) J Cardiovasc Magn Reson , vol.14 , pp. 61
    • Schwitter, J.1    Wacker, C.M.2    Wilke, N.3    Al-Saadi, N.4    Sauer, E.5    Huettle, K.6    Schönberg, S.O.7    Debl, K.8    Strohm, O.9    Ahlstrom, H.10    Dill, T.11    Hoebel, N.12    Simor, T.13


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.