메뉴 건너뛰기




Volumn 46, Issue 5, 2014, Pages 392-405

The role of abdominal compliance, the neglected parameter in critically ill patients - A consensus review of 16. Part 1: Definitions and pathophysiology

(16)  Malbrain, Manu L N G a   Roberts, Derek J b   De Laet, Inneke a,c   De Waele, Jan J c   Sugrue, Michael d   Schachtrupp, Alexander e   Duchesne, Juan f   Van Ramshorst, Gabrielle g   De Keulenaer, Bart h,i   Kirkpatrick, Andrew W j   Ahmadi Noorbakhsh, Siavash i   Mulier, Jan k   Ivatury, Rao l   Pracca, Francisco m   Wise, Robert n   Pelosi, Paolo o  


Author keywords

Abdominal compartment; Abdominal compliance; Abdominal hypertension; Abdominal pressure; Abdominal volume; Abdominal wall; Diagnosis; Laparoscopy; Pressure volume relation; Risk factors; Treatment

Indexed keywords

ABDOMINAL COMPARTMENT SYNDROME; ABDOMINAL COMPLIANCE; ABDOMINAL PRESSURE; ABDOMINAL VOLUME; ABDOMINAL WALL; ARTICLE; BODY POSITION; COMPLIANCE (PHYSICAL); CONSENSUS; CRITICALLY ILL PATIENT; DIAPHRAGM; ELASTICITY; HUMAN; INTRAABDOMINAL HYPERTENSION; ORGAN PERFUSION; PATHOPHYSIOLOGY; PHYSICAL PARAMETERS; PRESSURE MEASUREMENT; PRESSURE VOLUME CURVE; ABDOMEN; ANATOMY AND HISTOLOGY; CRITICAL ILLNESS; INTRA-ABDOMINAL HYPERTENSION; NOMENCLATURE; PRESSURE;

EID: 84916940869     PISSN: 16425758     EISSN: 17312531     Source Type: Journal    
DOI: 10.5603/AIT.2014.0062     Document Type: Article
Times cited : (58)

References (80)
  • 1
    • 33750217742 scopus 로고    scopus 로고
    • Results from the international conference of experts on intra-abdominal hypertension and abdominal compartment syndrome. I. Definitions
    • Malbrain ML, Cheatham ML, Kirkpatrick A et al.: Results from the International Conference of Experts on Intra-abdominal Hypertension and Abdominal Compartment Syndrome. I. Definitions. Intensive Care Med 2006; 32: 1722-1732.
    • (2006) Intensive Care Med , vol.32 , pp. 1722-1732
    • Malbrain, M.L.1    Cheatham, M.L.2    Kirkpatrick, A.3
  • 2
    • 33847653298 scopus 로고    scopus 로고
    • Results from the international conference of experts on intra-abdominal hypertension and abdominal compartment syndrome. II. Recommendations
    • Cheatham ML, Malbrain ML, Kirkpatrick A et al.: Results from the International Conference of Experts on Intra-abdominal Hypertension and Abdominal Compartment Syndrome. II. Recommendations. Intensive Care Med 2007; 33: 951-962.
    • (2007) Intensive Care Med , vol.33 , pp. 951-962
    • Cheatham, M.L.1    Malbrain, M.L.2    Kirkpatrick, A.3
  • 3
    • 84879090297 scopus 로고    scopus 로고
    • Intra-abdominal hypertension and the abdominal compartment syndrome: Updated consensus definitions and clinical practice guidelines from the World Society of the Abdominal Compartment Syndrome
    • Kirkpatrick AW, Roberts DJ, De Waele J et al.: Intra-abdominal hypertension and the abdominal compartment syndrome: updated consensus definitions and clinical practice guidelines from the World Society of the Abdominal Compartment Syndrome. Intensive Care Med 2013; 39: 1190-1206.
    • (2013) Intensive Care Med , vol.39 , pp. 1190-1206
    • Kirkpatrick, A.W.1    Roberts, D.J.2    De Waele, J.3
  • 4
    • 13444252257 scopus 로고    scopus 로고
    • Incidence and prognosis of intraabdominal hypertension in a mixed population of critically ill patients: A multiple-center epidemiological study
    • Malbrain ML, Chiumello D, Pelosi P, Bihari D et al.: Incidence and prognosis of intraabdominal hypertension in a mixed population of critically ill patients: a multiple-center epidemiological study. Crit Care Med 2005; 33: 315-322.
    • (2005) Crit Care Med , vol.33 , pp. 315-322
    • Malbrain, M.L.1    Chiumello, D.2    Pelosi, P.3    Bihari, D.4
  • 5
    • 2442616190 scopus 로고    scopus 로고
    • Prevalence of intra-abdominal hypertension in critically ill patients: A multicentre epidemiological study
    • Malbrain ML, Chiumello D, Pelosi P et al.: Prevalence of Intra-abdominal hypertension in critically ill patients: a multicentre epidemiological study. Intensive Care Med 2004; 30: 822-829.
    • (2004) Intensive Care Med , vol.30 , pp. 822-829
    • Malbrain, M.L.1    Chiumello, D.2    Pelosi, P.3
  • 6
    • 84901485094 scopus 로고    scopus 로고
    • A systematic review and individual patient data meta-analysis on intra-abdominal hypertension in critically ill patients: The wake-up project. World initiative on Abdominal Hypertension Epidemiology, a Unifying Project (WAKE-Up!)
    • Malbrain ML, Chiumello D, Cesana BM et al.: A systematic review and individual patient data meta-analysis on Intra-abdominal hypertension in critically ill patients: the wake-up project. World initiative on Abdominal Hypertension Epidemiology, a Unifying Project (WAKE-Up!). Minerva Anestesiol 2014; 80: 293-306.
    • (2014) Minerva Anestesiol , vol.80 , pp. 293-306
    • Malbrain, M.L.1    Chiumello, D.2    Cesana, B.M.3
  • 7
    • 84916940869 scopus 로고    scopus 로고
    • The role of abdominal compliance, the neglected parameter in critically ill patients - A consensus review of 16. Part 2: Measurement techniques and management recommendations
    • Malbrain MLNG, De laet I, De Waele J et al.: The role of abdominal compliance, the neglected parameter in critically ill patients - a consensus review of 16. Part 2: Measurement techniques and management recommendations. Anaesthesiol Intensive Ther 2014; 46: 392-405.
    • (2014) Anaesthesiol Intensive Ther , vol.46 , pp. 392-405
    • Malbrain, M.L.N.G.1    De Laet, I.2    De Waele, J.3
  • 8
    • 0002487105 scopus 로고    scopus 로고
    • Intra-abdominal pressure in the intensive care unit: Clinical tool or toy?
    • Vincent JL (ed.): Berlin: Springer-Verlag
    • Malbrain ML: Intra-abdominal pressure in the intensive care unit: Clinical tool or toy? In: Vincent JL (ed.): Yearbook of Intensive Care and Emergency Medicine. Berlin: Springer-Verlag 2001: 547-585.
    • (2001) Yearbook of Intensive Care and Emergency Medicine , pp. 547-585
    • Malbrain, M.L.1
  • 9
    • 1942519284 scopus 로고    scopus 로고
    • Is it wise not to think about intraabdominal hypertension in the ICU?
    • Malbrain ML: Is it wise not to think about intraabdominal hypertension in the ICU? Curr Opin Crit Care 2004; 10: 132-145.
    • (2004) Curr Opin Crit Care , vol.10 , pp. 132-145
    • Malbrain, M.L.1
  • 10
    • 0033943356 scopus 로고    scopus 로고
    • Abdominal pressure in the critically ill
    • Malbrain ML: Abdominal pressure in the critically ill. Curr Opin Crit Care 2000; 6: 17-29.
    • (2000) Curr Opin Crit Care , vol.6 , pp. 17-29
    • Malbrain, M.L.1
  • 11
    • 33744722834 scopus 로고    scopus 로고
    • Mechanical properties of the human abdominal wall measured in vivo during insufflation for laparoscopic surgery
    • Song C, Alijani A, Frank T, Hanna GB, Cuschieri A: Mechanical properties of the human abdominal wall measured in vivo during insufflation for laparoscopic surgery. Surg Endosc 2006; 20: 987-990.
    • (2006) Surg Endosc , vol.20 , pp. 987-990
    • Song, C.1    Alijani, A.2    Frank, T.3    Hanna, G.B.4    Cuschieri, A.5
  • 12
    • 79951721681 scopus 로고    scopus 로고
    • Forces and deformations of the abdominal wall - A mechanical and geometrical approach to the linea alba
    • Forstemann T, Trzewik J, Holste J et al.: Forces and deformations of the abdominal wall - a mechanical and geometrical approach to the linea alba. J Biomech 2011; 44: 600-606.
    • (2011) J Biomech , vol.44 , pp. 600-606
    • Forstemann, T.1    Trzewik, J.2    Holste, J.3
  • 13
    • 34249732090 scopus 로고    scopus 로고
    • Effect of intra-abdominal pressure on respiratory mechanics
    • Pelosi P, Quintel M, Malbrain ML: Effect of Intra-abdominal pressure on respiratory mechanics. Acta Clin Belg Suppl 2007; 62: 78-88.
    • (2007) Acta Clin Belg Suppl , vol.62 , pp. 78-88
    • Pelosi, P.1    Quintel, M.2    Malbrain, M.L.3
  • 14
    • 10744219512 scopus 로고    scopus 로고
    • An increase of abdominal pressure increases pulmonary edema in oleic acid-induced lung injury
    • Quintel M, Pelosi P, Caironi P et al.: An increase of abdominal pressure increases pulmonary edema in oleic acid-induced lung injury. Am J Respir Crit Care Med 2004; 169: 534-541.
    • (2004) Am J Respir Crit Care Med , vol.169 , pp. 534-541
    • Quintel, M.1    Pelosi, P.2    Caironi, P.3
  • 15
    • 84866258823 scopus 로고    scopus 로고
    • Relationship between abdominal pressure, pulmonary compliance, and cardiac preload in a porcine model
    • Wauters J, Claus P, Brosens N et al.: Relationship between abdominal pressure, pulmonary compliance, and cardiac preload in a porcine model. Crit Care Res Pract 2012; 2012: 763181.
    • (2012) Crit Care Res Pract , vol.2012 , pp. 763181
    • Wauters, J.1    Claus, P.2    Brosens, N.3
  • 16
    • 84867817907 scopus 로고    scopus 로고
    • Matching positive end-expiratory pressure to intra-abdominal pressure improves oxygenation in a porcine sick lung model of intra-abdominal hypertension
    • Regli A, Mahendran R, Fysh ET et al.: Matching positive end-expiratory pressure to Intra-abdominal pressure improves oxygenation in a porcine sick lung model of Intra-abdominal hypertension. Crit Care 2012; 16: R208.
    • (2012) Crit Care , vol.16 , pp. R208
    • Regli, A.1    Mahendran, R.2    Fysh, E.T.3
  • 17
    • 33745015118 scopus 로고    scopus 로고
    • Functional anatomy of the abdominal wall
    • Flament JB: Functional anatomy of the abdominal wall. Chirurg 2006; 77: 401-407.
    • (2006) Chirurg , vol.77 , pp. 401-407
    • Flament, J.B.1
  • 18
    • 10944225073 scopus 로고    scopus 로고
    • Anatomy of the anterior abdominal wall. Operative techniques in general surgery
    • Ahluwalia HS, Burger JP, Quinn TH: Anatomy of the anterior abdominal wall. operative techniques in general surgery. Oper Tech Gen Surg 2004; 6: 147-155.
    • (2004) Oper Tech Gen Surg , vol.6 , pp. 147-155
    • Ahluwalia, H.S.1    Burger, J.P.2    Quinn, T.H.3
  • 19
    • 67349155244 scopus 로고    scopus 로고
    • What is normal intra-abdominal pressure and how is it affected by positioning, body mass and positive end-expiratory pressure?
    • De Keulenaer BL, De Waele JJ, Powell B, Malbrain ML: What is normal Intra-abdominal pressure and how is it affected by positioning, body mass and positive end-expiratory pressure? Intensive Care Med 2009; 35: 969-976.
    • (2009) Intensive Care Med , vol.35 , pp. 969-976
    • De Keulenaer, B.L.1    De Waele, J.J.2    Powell, B.3    Malbrain, M.L.4
  • 20
    • 84896093255 scopus 로고    scopus 로고
    • Optimizing working space in laparoscopy: CT measurement of the effect of pre-stretching of the abdominal wall in a porcine model
    • Vlot J, Wijnen R, Stolker RJ, Bax KN: Optimizing working space in laparoscopy: CT measurement of the effect of pre-stretching of the abdominal wall in a porcine model. Surg Endosc Surg Endosc 2014; 28: 841-846.
    • (2014) Surg Endosc Surg Endosc , vol.28 , pp. 841-846
    • Vlot, J.1    Wijnen, R.2    Stolker, R.J.3    Bax, K.N.4
  • 21
    • 84859736759 scopus 로고    scopus 로고
    • Mechanically relevant consequences of the composite laminate-like design of the abdominal wall muscles and connective tissues
    • Brown SH: Mechanically relevant consequences of the composite laminate-like design of the abdominal wall muscles and connective tissues. Med Eng Phys 2012; 34: 521-523.
    • (2012) Med Eng Phys , vol.34 , pp. 521-523
    • Brown, S.H.1
  • 23
    • 0027970030 scopus 로고
    • Intra-abdominal pressure measurement using a modified nasogastric tube: Description and validation of a new technique
    • Sugrue M, Buist MD, Lee A, Sanchez DJ, Hillman KM: Intra-abdominal pressure measurement using a modified nasogastric tube: description and validation of a new technique. Intensive Care Med 1994; 20: 588-590.
    • (1994) Intensive Care Med , vol.20 , pp. 588-590
    • Sugrue, M.1    Buist, M.D.2    Lee, A.3    Sanchez, D.J.4    Hillman, K.M.5
  • 24
    • 77955662434 scopus 로고    scopus 로고
    • Impact of the patient's body position on the intraabdominal workspace during laparoscopic surgery
    • Mulier JP, Dillemans B, Van Cauwenberge S: Impact of the patient's body position on the intraabdominal workspace during laparoscopic surgery. Surg Endosc 2010; 24: 1398-402.
    • (2010) Surg Endosc , vol.24 , pp. 1398-1402
    • Mulier, J.P.1    Dillemans, B.2    Van Cauwenberge, S.3
  • 26
    • 34249732093 scopus 로고    scopus 로고
    • Historical highlights in concept and treatment of abdominal compartment syndrome
    • Van Hee R: Historical highlights in concept and treatment of abdominal compartment syndrome. Acta Clin Belg Suppl 2007; 62: 9-15.
    • (2007) Acta Clin Belg Suppl , vol.62 , pp. 9-15
    • Van Hee, R.1
  • 27
    • 0008574916 scopus 로고
    • Uber den einfluss des intraabdominalen druckes auf die absonderungsgeschwindigkeit des harnes
    • Wendt E: Uber den einfluss des intraabdominalen druckes auf die absonderungsgeschwindigkeit des harnes. Arch Physiologische Heilkunde 1876; 57: 525-527.
    • (1876) Arch Physiologische Heilkunde , vol.57 , pp. 525-527
    • Wendt, E.1
  • 28
    • 1642306412 scopus 로고    scopus 로고
    • Different techniques to measure intra-abdominal pressure (IAP): Time for a critical re-appraisal
    • Malbrain ML: Different techniques to measure intra-abdominal pressure (IAP): time for a critical re-appraisal. Intensive Care Med 2004; 30: 357-371.
    • (2004) Intensive Care Med , vol.30 , pp. 357-371
    • Malbrain, M.L.1
  • 29
    • 34047099114 scopus 로고
    • Intra-abdominal pressures
    • Emerson H: Intra-abdominal pressures. Arch Intern Med 1911; 7: 754-784.
    • (1911) Arch Intern Med , vol.7 , pp. 754-784
    • Emerson, H.1
  • 30
    • 18844394226 scopus 로고    scopus 로고
    • The assumed problem of air bubbles in the tubing during intra-abdominal pressure measurement - Author reply
    • Malbrain ML: The assumed problem of air bubbles in the tubing during intra-abdominal pressure measurement - author reply. Intensive Care Med 2004; 30: 1693.
    • (2004) Intensive Care Med , vol.30 , pp. 1693
    • Malbrain, M.L.1
  • 32
    • 36149066827 scopus 로고
    • Oscillatory flow in arteries: The constrained elastic tube as a model of arterial flow and pulse transmission
    • Womersley JR: Oscillatory flow in arteries: the constrained elastic tube as a model of arterial flow and pulse transmission. Phys Med Biol 1957; 2: 178-187.
    • (1957) Phys Med Biol , vol.2 , pp. 178-187
    • Womersley, J.R.1
  • 33
    • 0001024798 scopus 로고
    • The mechanism of the regulation of intra-abdominal pressure
    • Coombs HC: The mechanism of the regulation of Intra-abdominal pressure. Am J Physiol 1922; 61: 159-170.
    • (1922) Am J Physiol , vol.61 , pp. 159-170
    • Coombs, H.C.1
  • 34
    • 34147103808 scopus 로고    scopus 로고
    • Effect of patient positioning on intra-abdominal pressure monitoring
    • McBeth PB, Zygun DA, Widder S et al.: Effect of patient positioning on intra-abdominal pressure monitoring. Am J Surg 2007; 193: 644-647.
    • (2007) Am J Surg , vol.193 , pp. 644-647
    • McBeth, P.B.1    Zygun, D.A.2    Widder, S.3
  • 35
    • 76549126646 scopus 로고    scopus 로고
    • Do we need to know body anthropomorphic data whilst measuring abdominal pressure?
    • Malbrain ML, De laet I: Do we need to know body anthropomorphic data whilst measuring abdominal pressure? Intensive Care Med 2010; 36: 180-182.
    • (2010) Intensive Care Med , vol.36 , pp. 180-182
    • Malbrain, M.L.1    De Laet, I.2
  • 36
    • 0000668381 scopus 로고
    • The nature of intraperitoneal and intrarectal pressure
    • Rushmer R: The nature of intraperitoneal and intrarectal pressure Am J Physiol 1946: 242-249.
    • (1946) Am J Physiol , pp. 242-249
    • Rushmer, R.1
  • 40
    • 33750211393 scopus 로고    scopus 로고
    • Morbid obesity and chronic intra-abdominal hypertension
    • Ivatury R, Cheatham M, Malbrain M, Sugrue M (ed.): Georgetown, Landes Bioscience
    • Hamad GG, Peitzman AB: Morbid obesity and chronic intra-abdominal hypertension. In: Ivatury R, Cheatham M, Malbrain M, Sugrue M (ed.): Abdominal compartment syndrome. Georgetown, Landes Bioscience 2006: 187-194.
    • (2006) Abdominal Compartment Syndrome , pp. 187-194
    • Hamad, G.G.1    Peitzman, A.B.2
  • 41
    • 0031764813 scopus 로고    scopus 로고
    • Increased intra-abdominal pressure in obesity
    • Sugerman HJ: Increased intra-abdominal pressure in obesity. Int J Obes Relat Metab Disord 1998; 22: 1138.
    • (1998) Int J Obes Relat Metab Disord , vol.22 , pp. 1138
    • Sugerman, H.J.1
  • 42
    • 0031023631 scopus 로고    scopus 로고
    • Intra-abdominal pressure, sagittal abdominal diameter and obesity comorbidity
    • Sugerman H, Windsor A, Bessos M, Wolfe L: Intra-abdominal pressure, sagittal abdominal diameter and obesity comorbidity. J Intern Med 1997; 241: 71-79.
    • (1997) J Intern Med , vol.241 , pp. 71-79
    • Sugerman, H.1    Windsor, A.2    Bessos, M.3    Wolfe, L.4
  • 43
    • 4444266712 scopus 로고    scopus 로고
    • Intra-abdominal hypertension and the abdominal compartment syndrome
    • Hunter JD, Damani Z: Intra-abdominal hypertension and the abdominal compartment syndrome. Anaesthesia 2004; 59: 899-907.
    • (2004) Anaesthesia , vol.59 , pp. 899-907
    • Hunter, J.D.1    Damani, Z.2
  • 44
    • 80053999686 scopus 로고    scopus 로고
    • Hypothesis: Preeclampsia is a venous disease secondary to an increased intra-abdominal pressure
    • Sugerman H: Hypothesis: preeclampsia is a venous disease secondary to an increased Intra-abdominal pressure. Med Hypotheses 2011; 77: 841-849.
    • (2011) Med Hypotheses , vol.77 , pp. 841-849
    • Sugerman, H.1
  • 45
    • 84887349991 scopus 로고    scopus 로고
    • Risk factors for intra-abdominal hypertension and abdominal compartment syndrome among adult intensive care unit patients: A systematic review and meta-analysis
    • Holodinsky JK, Roberts DJ, Ball CG et al.: Risk factors for intra-abdominal hypertension and abdominal compartment syndrome among adult intensive care unit patients: a systematic review and meta-analysis. Crit Care 2013; 17: R249.
    • (2013) Crit Care , vol.17 , pp. R249
    • Holodinsky, J.K.1    Roberts, D.J.2    Ball, C.G.3
  • 46
    • 84896695453 scopus 로고    scopus 로고
    • Integration of inspiratory and expiratory intra-abdominal pressure: A novel concept looking at mean intra-abdominal pressure
    • Ahmadi-Noorbakhsh S, Malbrain ML: Integration of inspiratory and expiratory intra-abdominal pressure: a novel concept looking at mean Intra-abdominal pressure. Ann Intensive Care 2012; 2 (Suppl 1): S18.
    • (2012) Ann Intensive Care , vol.2 , pp. S18
    • Ahmadi-Noorbakhsh, S.1    Malbrain, M.L.2
  • 47
    • 79952118556 scopus 로고    scopus 로고
    • Clinical review: Intra-abdominal hypertension: Does it influence the physiology of prone ventilation?
    • Kirkpatrick AW, Pelosi P, De Waele JJ et al.: Clinical review: intra-abdominal hypertension: does it influence the physiology of prone ventilation? Crit Care 2010; 14: 232.
    • (2010) Crit Care , vol.14 , pp. 232
    • Kirkpatrick, A.W.1    Pelosi, P.2    De Waele, J.J.3
  • 48
    • 49749119992 scopus 로고    scopus 로고
    • Respiratory variation of intra-abdominal pressure: Indirect indicator of abdominal compliance?
    • Sturini E, Saporito A, Sugrue M, Parr MJ, Bishop G, Braschi A: Respiratory variation of intra-abdominal pressure: indirect indicator of abdominal compliance? Intensive Care Med 2008; 34: 1632-1637.
    • (2008) Intensive Care Med , vol.34 , pp. 1632-1637
    • Sturini, E.1    Saporito, A.2    Sugrue, M.3    Parr, M.J.4    Bishop, G.5    Braschi, A.6
  • 49
    • 84884146223 scopus 로고    scopus 로고
    • The effect of body position on compartmental intra-abdominal pressure following liver transplantation
    • Cresswell AB, Jassem W, Srinivasan P et al.: The effect of body position on compartmental Intra-abdominal pressure following liver transplantation. Ann Intensive Care 2012; 2 (Suppl 1): S12.
    • (2012) Ann Intensive Care , vol.2 , pp. S12
    • Cresswell, A.B.1    Jassem, W.2    Srinivasan, P.3
  • 50
    • 77951991317 scopus 로고    scopus 로고
    • Localised abdominal compartment syndrome: Bladder-over-gastric pressure ratio (B/G ratio) as a clue to diagnosis
    • Malbrain ML, De Laet IE, Willems A, Van Regenmortel N, Schoonheydt K, Dits H: Localised abdominal compartment syndrome: bladder-over-gastric pressure ratio (B/G ratio) as a clue to diagnosis. Acta Clin Belg 2010; 65: 98-106.
    • (2010) Acta Clin Belg , vol.65 , pp. 98-106
    • Malbrain, M.L.1    De Laet, I.E.2    Willems, A.3    Van Regenmortel, N.4    Schoonheydt, K.5    Dits, H.6
  • 51
    • 84884162734 scopus 로고    scopus 로고
    • Determinants of the abdominal pressure volume relation in non ACS patients
    • Mulier JP, Dillemans B, Heremans L: Determinants of the abdominal pressure volume relation in non ACS patients. Acta Clin Belg Suppl 2007; 62: 289.
    • (2007) Acta Clin Belg Suppl , vol.62 , pp. 289
    • Mulier, J.P.1    Dillemans, B.2    Heremans, L.3
  • 52
    • 84916941110 scopus 로고    scopus 로고
    • CT analysis of the elastic deformation and elongation of the abdominal wall during colon insufflation for virtual coloscopy
    • Mulier JP, Coenegrachts K, Van de Moortele K: CT analysis of the elastic deformation and elongation of the abdominal wall during colon insufflation for virtual coloscopy. Eur J Anaesthesiol 2008; 25(S44): 42.
    • (2008) Eur J Anaesthesiol , vol.25 , Issue.S44 , pp. 42
    • Mulier, J.P.1    Coenegrachts, K.2    Van De Moortele, K.3
  • 53
    • 55349121482 scopus 로고    scopus 로고
    • Abdominal accommodation: A coordinated adaptation of the abdominal wall to its content
    • Villoria A, Azpiroz F, Soldevilla A, Perez F, Malagelada JR: Abdominal accommodation: a coordinated adaptation of the abdominal wall to its content. Am J Gastroenterol 2008; 103: 2807-2815.
    • (2008) Am J Gastroenterol , vol.103 , pp. 2807-2815
    • Villoria, A.1    Azpiroz, F.2    Soldevilla, A.3    Perez, F.4    Malagelada, J.R.5
  • 54
    • 84916941833 scopus 로고    scopus 로고
    • Evaluation of a mechanical build model of the abdominal pressure volume relation
    • Mulier JP, Dillemans B, Heremans L, Vanlander E: Evaluation of a mechanical build model of the abdominal pressure volume relation. Eur J Anaesthesiol 2008; 25(S24): 14.
    • (2008) Eur J Anaesthesiol , vol.25 , Issue.S24 , pp. 14
    • Mulier, J.P.1    Dillemans, B.2    Heremans, L.3    Vanlander, E.4
  • 55
    • 34447532209 scopus 로고    scopus 로고
    • Intraperitoneal pressure in PD patients: Relationship to intraperitoneal volume, body size and PD-related complications
    • Dejardin A, Robert A, Goffin E: Intraperitoneal pressure in PD patients: relationship to intraperitoneal volume, body size and PD-related complications. Nephrol Dial Transplant 2007; 22: 1437-1444.
    • (2007) Nephrol Dial Transplant , vol.22 , pp. 1437-1444
    • Dejardin, A.1    Robert, A.2    Goffin, E.3
  • 57
    • 0041919614 scopus 로고    scopus 로고
    • Intraperitoneal pressure in children: Fill-volume related and impacted by body mass index
    • Fischbach M, Terzic J, Provot E et al.: Intraperitoneal pressure in children: fill-volume related and impacted by body mass index. Perit Dial Int 2003; 23: 391-394.
    • (2003) Perit Dial Int , vol.23 , pp. 391-394
    • Fischbach, M.1    Terzic, J.2    Provot, E.3
  • 58
    • 0032222859 scopus 로고    scopus 로고
    • Impact of increased intraperitoneal fill volume on tolerance and dialysis effectiveness in children
    • Fischbach M, Terzic J, Gaugler C et al.: Impact of increased intraperitoneal fill volume on tolerance and dialysis effectiveness in children. Adv Perit Dial 1998; 14: 258-264.
    • (1998) Adv Perit Dial , vol.14 , pp. 258-264
    • Fischbach, M.1    Terzic, J.2    Gaugler, C.3
  • 59
    • 84916889589 scopus 로고    scopus 로고
    • Is the abdominal pressure? Volume relation linear?
    • Mulier JP: Is the abdominal pressure? volume relation linear? Eur J Anaesthesiol 2006; 23(S124): 32.
    • (2006) Eur J Anaesthesiol , vol.23 , Issue.S124 , pp. 32
    • Mulier, J.P.1
  • 60
    • 33646356462 scopus 로고    scopus 로고
    • Effect of body habitus and parity on insufflated CO2 volume at various intraabdominal pressures during laparoscopic access in women
    • Abu-Rafea B, Vilos GA, Vilos AG, Hollett-Caines J, Al-Omran M: Effect of body habitus and parity on insufflated CO2 volume at various intraabdominal pressures during laparoscopic access in women. J Minim Invasive Gynecol 2006; 13: 205-210.
    • (2006) J Minim Invasive Gynecol , vol.13 , pp. 205-210
    • Abu-Rafea, B.1    Vilos, G.A.2    Vilos, A.G.3    Hollett-Caines, J.4    Al-Omran, M.5
  • 61
    • 84855842704 scopus 로고    scopus 로고
    • The interpretation of intra-abdominal pressures from animal models: The rabbit to human example
    • Yoshino O, Quail A, Oldmeadow C, Balogh ZJ: The interpretation of Intra-abdominal pressures from animal models: the rabbit to human example. Injury 2011; 43: 169-173.
    • (2011) Injury , vol.43 , pp. 169-173
    • Yoshino, O.1    Quail, A.2    Oldmeadow, C.3    Balogh, Z.J.4
  • 62
    • 0026589118 scopus 로고
    • Volume infusion produces abdominal distension, lung compression, and chest wall stiffening in pigs
    • Mutoh T, Lamm WJ, Embree LJ, Hildebrandt J, Albert RK: Volume infusion produces abdominal distension, lung compression, and chest wall stiffening in pigs. J Appl Physiol 1992; 72: 575-582.
    • (1992) J Appl Physiol , vol.72 , pp. 575-582
    • Mutoh, T.1    Lamm, W.J.2    Embree, L.J.3    Hildebrandt, J.4    Albert, R.K.5
  • 64
    • 0141920481 scopus 로고    scopus 로고
    • Measurement of hydrostatic intraperitoneal pressure: A useful tool for the improvement of dialysis dose prescription
    • Fischbach M, Terzic J, Laugel V, Escande B, Dangelser C, Helmstetter A: Measurement of hydrostatic intraperitoneal pressure: a useful tool for the improvement of dialysis dose prescription. Pediatr Nephrol 2003; 18: 976-980.
    • (2003) Pediatr Nephrol , vol.18 , pp. 976-980
    • Fischbach, M.1    Terzic, J.2    Laugel, V.3    Escande, B.4    Dangelser, C.5    Helmstetter, A.6
  • 65
    • 35448947970 scopus 로고    scopus 로고
    • The polycompartment syndrome: Towards an understanding of the interactions between different compartments!
    • Malbrain ML, Wilmer A: The polycompartment syndrome: towards an understanding of the interactions between different compartments! Intensive Care Med 2007; 33: 1869-1872.
    • (2007) Intensive Care Med , vol.33 , pp. 1869-1872
    • Malbrain, M.L.1    Wilmer, A.2
  • 66
  • 67
    • 77957839427 scopus 로고    scopus 로고
    • The polycompartment syndrome - Part 1: Pathophysiology and pressure measurement of pelvic and abdominal compartment syndromes
    • Malbrain MLNG, De laet I: The polycompartment syndrome - Part 1: Pathophysiology and pressure measurement of pelvic and abdominal compartment syndromes. ICU Management 2009; 9: 19-22.
    • (2009) ICU Management , vol.9 , pp. 19-22
    • Malbrain, M.L.N.G.1    De Laet, I.2
  • 68
    • 84916942565 scopus 로고    scopus 로고
    • The polycompartment syndrome - Part 2: From cardiac to thoracic - The other compartment syndromes
    • Malbrain MLNG, De laet I: The polycompartment syndrome - Part 2: From cardiac to thoracic - the other compartment syndromes. ICU Management 2009; 9: 18-19.
    • (2009) ICU Management , vol.9 , pp. 18-19
    • Malbrain, M.L.N.G.1    De Laet, I.2
  • 69
    • 62649109441 scopus 로고    scopus 로고
    • A new concept: The polycompartment syndrome - Part 1
    • Autumn
    • Malbrain MLNG, De laet I: A new concept: the polycompartment syndrome - Part 1. Int J Intensive Care 2008; Autumn 2008: 19-24.
    • Int J Intensive Care 2008 , vol.2008 , pp. 19-24
    • Malbrain, M.L.N.G.1    De Laet, I.2
  • 70
    • 34249749462 scopus 로고    scopus 로고
    • New and old tools for abdominal imaging in critically ill patients
    • Severgnini P, Inzigneri G, Olvera C et al.: New and old tools for abdominal imaging in critically ill patients. Acta Clin Belg Suppl 2007; 62: 173-182.
    • (2007) Acta Clin Belg Suppl , vol.62 , pp. 173-182
    • Severgnini, P.1    Inzigneri, G.2    Olvera, C.3
  • 71
    • 59049084802 scopus 로고    scopus 로고
    • Intra-abdominal hypertension: evolving concepts
    • viii
    • Malbrain ML, De laet IE: Intra-abdominal hypertension: evolving concepts. Clin Chest Med 2009; 30: 45-70, viii.
    • (2009) Clin Chest Med , vol.30 , pp. 45-70
    • Malbrain, M.L.1    De Laet, I.2
  • 72
    • 2542641702 scopus 로고    scopus 로고
    • Does the intrapelvic compartment syndrome exist?
    • Hessmann M, Rommens P: Does the intrapelvic compartment syndrome exist? Acta Chir Belg 1998; 98: 18-22.
    • (1998) Acta Chir Belg , vol.98 , pp. 18-22
    • Hessmann, M.1    Rommens, P.2
  • 74
    • 38849130614 scopus 로고    scopus 로고
    • Continuous intra-abdominal pressure monitoring: This is the way to go!
    • Malbrain ML, De laet I, De Waele JJ: Continuous intra-abdominal pressure monitoring: this is the way to go! Int J Clin Prac 2008; 62: 359-362.
    • (2008) Int J Clin Prac , vol.62 , pp. 359-362
    • Malbrain, M.L.1    De Laet, I.2    De Waele, J.J.3
  • 75
    • 83455169751 scopus 로고    scopus 로고
    • Percutaneous catheter decompression in the treatment of elevated intraabdominal pressure
    • Cheatham ML, Safcsak K: Percutaneous catheter decompression in the treatment of elevated intraabdominal pressure. Chest 2011; 140: 1428-1435.
    • (2011) Chest , vol.140 , pp. 1428-1435
    • Cheatham, M.L.1    Safcsak, K.2
  • 76
    • 34247550878 scopus 로고    scopus 로고
    • Effect of bladder volume on measured intravesical pressure: A prospective cohort study
    • Malbrain ML, Deeren DH: Effect of bladder volume on measured intravesical pressure: a prospective cohort study. Crite Care 2006; 10: R98.
    • (2006) Crite Care , vol.10 , pp. R98
    • Malbrain, M.L.1    Deeren, D.H.2
  • 77
    • 34548119510 scopus 로고    scopus 로고
    • The effect of different volumes and temperatures of saline on the bladder pressure measurement in critically ill patients
    • Chiumello D, Tallarini F, Chierichetti M et al.: The effect of different volumes and temperatures of saline on the bladder pressure measurement in critically ill patients. Crite Care 2007; 11: R82.
    • (2007) Crite Care , vol.11 , pp. R82
    • Chiumello, D.1    Tallarini, F.2    Chierichetti, M.3
  • 78
    • 33344465726 scopus 로고    scopus 로고
    • Saline volume in transvesical intra-abdominal pressure measurement: Enough is enough
    • De Waele J, Pletinckx P, Blot S, Hoste E: Saline volume in transvesical intra-abdominal pressure measurement: enough is enough. Intensive Care Med 2006; 32: 455-459.
    • (2006) Intensive Care Med , vol.32 , pp. 455-459
    • De Waele, J.1    Pletinckx, P.2    Blot, S.3    Hoste, E.4
  • 80
    • 84884139475 scopus 로고    scopus 로고
    • Effect of mechanical ventilation on intra-abdominal pressure in critically ill patients without other risk factors for abdominal hypertension: An observational multicenter epidemiological study
    • Soler Morejon C, Tamargo Barbeito TO: Effect of mechanical ventilation on Intra-abdominal pressure in critically ill patients without other risk factors for abdominal hypertension: an observational multicenter epidemiological study. Ann Intensive Care 2012; 2 (Suppl. 1): S22.
    • (2012) Ann Intensive Care , vol.2 , pp. S22
    • Soler Morejon, C.1    Tamargo Barbeito, T.O.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.