메뉴 건너뛰기




Volumn 17, Issue 4, 2014, Pages 366-369

Initial experience of EVAHEART explantation after continuous-flow LVAD off test with percutaneous occlusion balloon

Author keywords

EVAHEART; Explantation; Left ventricular assist device; LVAD off test

Indexed keywords

CARVEDILOL; DIPEPTIDYL CARBOXYPEPTIDASE INHIBITOR; SPIRONOLACTONE;

EID: 84914159068     PISSN: 14347229     EISSN: 16190904     Source Type: Journal    
DOI: 10.1007/s10047-014-0784-y     Document Type: Article
Times cited : (3)

References (5)
  • 1
    • 83555170951 scopus 로고    scopus 로고
    • Effects of continuous-flow versus pulsatile-flow left ventricular assist devices on myocardial unloading and remodeling
    • PID: 21765125
    • Kato TS, Chokshi A, Singh P, Khawaja T, Cheema F, Akashi H, et al. Effects of continuous-flow versus pulsatile-flow left ventricular assist devices on myocardial unloading and remodeling. Circ Heart Fail. 2011;4(5):546–53.
    • (2011) Circ Heart Fail , vol.4 , Issue.5 , pp. 546-553
    • Kato, T.S.1    Chokshi, A.2    Singh, P.3    Khawaja, T.4    Cheema, F.5    Akashi, H.6
  • 3
    • 79955869935 scopus 로고    scopus 로고
    • What is the ideal off-test trial for continuous-flow ventricular-assist-device explantation? Intracircuit back-flow analysis in a mock circulation model
    • PID: 21243384
    • Ando M, Nishimura T, Takewa Y, Ogawa D, Yamazaki K, Kashiwa K, et al. What is the ideal off-test trial for continuous-flow ventricular-assist-device explantation? Intracircuit back-flow analysis in a mock circulation model. J Artif Organs. 2011;14:70–3.
    • (2011) J Artif Organs , vol.14 , pp. 70-73
    • Ando, M.1    Nishimura, T.2    Takewa, Y.3    Ogawa, D.4    Yamazaki, K.5    Kashiwa, K.6
  • 4
    • 80053935814 scopus 로고    scopus 로고
    • Percutaneous balloon occlusion of a left ventricular assist device outflow cannula to facilitate evaluation of myocardial recovery
    • PID: 21873080
    • Potapov EV, Schweiger M, Krabatsch T. Percutaneous balloon occlusion of a left ventricular assist device outflow cannula to facilitate evaluation of myocardial recovery. J Heart Lung Transplant. 2011;30(11):1300–1.
    • (2011) J Heart Lung Transplant , vol.30 , Issue.11 , pp. 1300-1301
    • Potapov, E.V.1    Schweiger, M.2    Krabatsch, T.3
  • 5
    • 38749092155 scopus 로고    scopus 로고
    • Limited surgical approach for explanting the HeartMate II left ventricular assist device after myocardial recovery
    • COI: 1:STN:280:DC%2BD1c%2Fos1SltQ%3D%3D, PID: 18242292
    • Haj-Yahia S, Birks EJ, Dreyfus G, Khaghani A. Limited surgical approach for explanting the HeartMate II left ventricular assist device after myocardial recovery. J Thorac Cardiovasc Surg. 2008;135:453–4.
    • (2008) J Thorac Cardiovasc Surg , vol.135 , pp. 453-454
    • Haj-Yahia, S.1    Birks, E.J.2    Dreyfus, G.3    Khaghani, A.4