What is the ideal off-test trial for continuous-flow ventricular-assist- device explantation? Intracircuit back-flow analysis in a mock circulation model

Author keywords

Bridge to recovery; Left ventricular assist device; Mock circulation model

Indexed keywords

ARTICLE; ASCENDING AORTA; CENTRIFUGATION; CONTROLLED STUDY; EXPLANT; FLOW KINETICS; FLOW MEASUREMENT; HEART CYCLE; HEART PERFUSION; HEART RATE VARIABILITY; HEART WORK; HEMODYNAMIC MONITORING; LEFT VENTRICULAR ASSIST DEVICE; PRIORITY JOURNAL; PROCESS DEVELOPMENT; PROCESS MODEL; PULSE RATE; SYSTEMIC CIRCULATION;

EID: 79955869935     PISSN: 14347229     EISSN: None     Source Type: Journal    
DOI: 10.1007/s10047-010-0543-7     Document Type: Article
Times cited : (18)

References (6)
  • 2
    • 65449181968 scopus 로고    scopus 로고
    • To explant or not to explants: An invasive and noninvasive monitoring protocol to determine the need of continued ventricular assist device support
    • Osaki S, Sweitzer NK, Rahko PS, Murray MA, Hoffmann JA, Johnson MR, Edwards NM, Kohmoto T. To explant or not to explants: an invasive and noninvasive monitoring protocol to determine the need of continued ventricular assist device support. Congest Heart Fail. 2009;15:58-62.
    • (2009) Congest Heart Fail , vol.15 , pp. 58-62
    • Osaki, S.1    Sweitzer, N.K.2    Rahko, P.S.3    Murray, M.A.4    Hoffmann, J.A.5    Johnson, M.R.6    Edwards, N.M.7    Kohmoto, T.8
  • 3
    • 38049129742 scopus 로고    scopus 로고
    • How to ensure safety factors in the development of artificial heart
    • Umezu Mitsuo. How to ensure safety factors in the development of artificial heart. Lect Notes Comput Sci. 2007;4689:88-96.
    • (2007) Lect Notes Comput Sci , vol.4689 , pp. 88-96
    • Mitsuo, U.1
  • 5
    • 33645084581 scopus 로고    scopus 로고
    • Hemodynamics and patient safety during pump-off studies of an axial-flow left ventricular assist device
    • Myers TJ, Frazier OH, Mesina HS, Radovancevic B, Gregoric ID. Hemodynamics and patient safety during pump-off studies of an axial-flow left ventricular assist device. J Heart Lung Transplant. 2006;25:379-83.
    • (2006) J Heart Lung Transplant , vol.25 , pp. 379-383
    • Myers, T.J.1    Frazier, O.H.2    Mesina, H.S.3    Radovancevic, B.4    Gregoric, I.D.5
  • 6
    • 0031977417 scopus 로고    scopus 로고
    • The safety system for the rotary blood pump, combination of the valve and LVAD pulsatile mode: In vitro test
    • DOI 10.1046/j.1525-1594.1998.05068.x
    • Tayama E, Ohashi Y, Niimi Y, Takami Y, Ohtsuka G, Nakata K, Benkowski R, Glueck JA, Nosé Y. The safety system for the rotary blood pump, combination of the valve and LVAD pulsatile mode: in vitro test. Artif Organs. 1998;22:342-5. (Pubitemid 28188451)
    • (1998) Artificial Organs , vol.22 , Issue.4 , pp. 342-345
    • Tayama, E.1    Ohashi, Y.2    Niimi, Y.3    Takami, Y.4    Ohtsuka, G.5    Nakata, K.-I.6    Benkowski, R.7    Glueck, J.A.8    Nose, Y.9


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.