메뉴 건너뛰기




Volumn , Issue , 2014, Pages 1066-1071

Noise cancellation for electrotactile sensory feedback of myoelectric forearm prostheses

Author keywords

bidirectional control interface; electrotactile sensory feedback; myoelectric forearm prostheses

Indexed keywords

BIOMEDICAL SIGNAL PROCESSING; DIGITAL SIGNAL PROCESSING; ELECTROMYOGRAPHY; FEEDBACK; SENSORY FEEDBACK; SIGNAL TO NOISE RATIO;

EID: 84914133321     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/ICInfA.2014.6932807     Document Type: Conference Paper
Times cited : (12)

References (18)
  • 2
    • 79960791840 scopus 로고    scopus 로고
    • Electromyogram pattern recognition for control of powered upper-limb prostheses: State of the art and challenges for clinical use
    • Scheme and K. Englehart, "Electromyogram pattern recognition for control of powered upper-limb prostheses: state of the art and challenges for clinical use", Journal of Rehabilitation Research and Development, 2011, 48(6): 643-660.
    • (2011) Journal of Rehabilitation Research and Development , vol.48 , Issue.6 , pp. 643-660
    • Scheme1    Englehart, K.2
  • 4
    • 60249100489 scopus 로고    scopus 로고
    • Consumer design priorities for upper limb prosthetics
    • Biddiss, D. Beaton, and T. Chau, "Consumer design priorities for upper limb prosthetics". Disabil. Rehabil. Assist. Technol, 2007, 2(6), 346-357.
    • (2007) Disabil. Rehabil. Assist. Technol , vol.2 , Issue.6 , pp. 346-357
    • Beaton, B.D.1    Chau, T.2
  • 6
    • 84856201341 scopus 로고    scopus 로고
    • A miniature vibrotactile sensory substitution device for multi-fingered hand prosthetics
    • C. Cipriani, M. D'Alonzo, and M. Carrozza, "A miniature vibrotactile sensory substitution device for multi-fingered hand prosthetics", IEEE Transactions on Biomedical Engineering, 2012, 59(2), 400-408.
    • (2012) IEEE Transactions on Biomedical Engineering , vol.59 , Issue.2 , pp. 400-408
    • Cipriani, C.1    D'Alonzo, M.2    Carrozza, M.3
  • 7
    • 84871981621 scopus 로고    scopus 로고
    • Artificial redirection of sensation from prosthetic fingers to the phantom hand map on transradial amputees: Vibrotactile versus mechanotactile sensory feedback
    • C. Antfolk, M. D'Alonzo, M. Controzzi, G. Lundborg, B. Rosen, and et al., "Artificial Redirection of Sensation From Prosthetic Fingers to the Phantom Hand Map on Transradial Amputees: Vibrotactile Versus Mechanotactile Sensory Feedback", IEEE Transactions on Neural Systems and Rehabilitation Engineering, 2013, 21(1), 112-120.
    • (2013) IEEE Transactions on Neural Systems and Rehabilitation Engineering , vol.21 , Issue.1 , pp. 112-120
    • Antfolk, C.1    D'Alonzo, M.2    Controzzi, M.3    Lundborg, G.4    Rosen, B.5
  • 8
    • 84864217853 scopus 로고    scopus 로고
    • Vibro-and electrotactile user feedback on hand opening for myoelectric forearm prostheses
    • H. Witteveen, E. Droog, J. Rietman, and P. Veltink, "Vibro-and Electrotactile User Feedback on Hand Opening for Myoelectric Forearm Prostheses", IEEE Transactions on Biomedical Engineering, 2012, 59(8), 2219-2226.
    • (2012) IEEE Transactions on Biomedical Engineering , vol.59 , Issue.8 , pp. 2219-2226
    • Witteveen, H.1    Droog, E.2    Rietman, J.3    Veltink, P.4
  • 13
    • 0021055056 scopus 로고
    • Optimization of pulse duration and pulse charge during transcutaneous electrical nerve stimulation
    • Alon, J. Allin, and G. Inbar, "Optimization of pulse duration and pulse charge during transcutaneous electrical nerve stimulation", Aust J Physiother, 1983, 29(6), 195-201.
    • (1983) Aust J Physiother , vol.29 , Issue.6 , pp. 195-201
    • Allin, A.J.1    Inbar, G.2
  • 16
    • 0028383996 scopus 로고
    • A family of normalized LMS algorithms
    • S. Douglas, "A family of normalized LMS algorithms", IEEE Signal Processing Letters, 1994, 1(3), 49-51.
    • (1994) IEEE Signal Processing Letters , vol.1 , Issue.3 , pp. 49-51
    • Douglas, S.1
  • 17
    • 84949433866 scopus 로고    scopus 로고
    • Analysis of the output spectrum for direct digital frequency synthesizers in the presence of phase truncation and finite arithmetic precision
    • A. Torosyan, and A. Willson, "Analysis of the output spectrum for direct digital frequency synthesizers in the presence of phase truncation and finite arithmetic precision", In the Proceedings of International Symposium on Image and Signal Processing and Analysis, 2001, 458-463.
    • (2001) The Proceedings of International Symposium on Image and Signal Processing and Analysis , pp. 458-463
    • Torosyan, A.1    Willson, A.2
  • 18
    • 51649107181 scopus 로고    scopus 로고
    • Otto Bock Company accessed February 8 2014)
    • Otto Bock Company (2014), "Otto Bock MYOBOCK 13E200=50 electrodes", available at: www.ottobock. com/cps/rde/xchg/ob-us-en/hs.xsl/16573.html ?id=16607 (accessed February 8 2014).
    • (2014) Otto Bock MYOBOCK 13E200=50 Electrodes


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.