Development of a novel MWCNTs-triazene-modified carbon paste electrode for potentiometric assessment of Hg(II) in the aquatic environments

Author keywords

Mercury(II); Modified carbon paste electrode; Multi walled carbon nanotube; Potentiometric sensor; Triazene

Indexed keywords

CARBON; ELECTRODES; IONS; MERCURY (METAL); POTENTIOMETERS (ELECTRIC MEASURING INSTRUMENTS); POTENTIOMETRIC SENSORS; TITRATION; VOLTAMMETRY; YARN;

EID: 84912575223     PISSN: 09284931     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.msec.2014.11.011     Document Type: Article
Times cited : (31)

References (42)
  • 1
    • 0036669292 scopus 로고    scopus 로고
    • The toxicology of mercury, the toxicology of heavy metals. Part II. Mercury
    • L.A. Broussard, C.A. Hammett-Stabler, R.E. Winecker, and J.D. Ropero The toxicology of mercury, the toxicology of heavy metals. Part II. Mercury Lab. Med. 33 2002 614 625
    • (2002) Lab. Med. , vol.33 , pp. 614-625
    • Broussard, L.A.1    Hammett-Stabler, C.A.2    Winecker, R.E.3    Ropero, J.D.4
  • 2
    • 0036227163 scopus 로고    scopus 로고
    • Mercury and the central nervous system
    • J.S. Woods Mercury and the central nervous system Environ. Health Perspect. 110 2002 A177
    • (2002) Environ. Health Perspect. , vol.110 , pp. 177
    • Woods, J.S.1
  • 3
    • 50149085273 scopus 로고    scopus 로고
    • Application of a wool column for flow injection online preconcentration of inorganic mercury(II) and methyl mercury species prior to atomic fluorescence measurement
    • V.N. Tirtom, S. Goulding, and E. Henden Application of a wool column for flow injection online preconcentration of inorganic mercury(II) and methyl mercury species prior to atomic fluorescence measurement Talanta 76 2008 1212 1217
    • (2008) Talanta , vol.76 , pp. 1212-1217
    • Tirtom, V.N.1    Goulding, S.2    Henden, E.3
  • 4
    • 33745146563 scopus 로고    scopus 로고
    • Determination of mercury in fish by cold vapor atomic absorption spectrophotometry using a multi-commuted flow injection analysis system
    • M.F. Silva, I.V. Toth, and A.O.S.S. Rangel Determination of mercury in fish by cold vapor atomic absorption spectrophotometry using a multi-commuted flow injection analysis system Anal. Sci. 22 2006 861 864
    • (2006) Anal. Sci. , vol.22 , pp. 861-864
    • Silva, M.F.1    Toth, I.V.2    Rangel, A.O.S.S.3
  • 5
    • 0037809216 scopus 로고    scopus 로고
    • Determination of mercury(II) ion by electrochemical cold vapor generation atomic absorption spectrometry
    • M.H. Arbab-Zavar, G.H. Rounaghi, M. Chamsaz, and M. Masrournia Determination of mercury(II) ion by electrochemical cold vapor generation atomic absorption spectrometry Anal. Sci. 19 2003 743 746
    • (2003) Anal. Sci. , vol.19 , pp. 743-746
    • Arbab-Zavar, M.H.1    Rounaghi, G.H.2    Chamsaz, M.3    Masrournia, M.4
  • 6
    • 84865682771 scopus 로고    scopus 로고
    • Multivariate optimization of mercury determination by flow injection-cold vapor generation-inductively coupled plasma optical emission spectrometry
    • V.C.G. dos Santos, M.T. Grassi, M.S. de Campos, P.G. Peralta-Zamora, and G. Abate Multivariate optimization of mercury determination by flow injection-cold vapor generation-inductively coupled plasma optical emission spectrometry Analyst 137 2012 4458 4463
    • (2012) Analyst , vol.137 , pp. 4458-4463
    • Dos Santos, V.C.G.1    Grassi, M.T.2    De Campos, M.S.3    Peralta-Zamora, P.G.4    Abate, G.5
  • 7
    • 80053286386 scopus 로고    scopus 로고
    • Mercury determination in non- and biodegradable materials by cold vapor capacitively coupled plasma microtorch atomic emission spectrometry
    • T. Frentiu, A.I. Mihaltan, M. Ponta, E. Darvasi, M. Frentiu, and E. Cordos Mercury determination in non- and biodegradable materials by cold vapor capacitively coupled plasma microtorch atomic emission spectrometry J. Hazard. Mater. 193 2011 65 69
    • (2011) J. Hazard. Mater. , vol.193 , pp. 65-69
    • Frentiu, T.1    Mihaltan, A.I.2    Ponta, M.3    Darvasi, E.4    Frentiu, M.5    Cordos, E.6
  • 8
    • 84861148310 scopus 로고    scopus 로고
    • Automatic flow-batch system for cold vapor atomic absorption spectroscopy determination of mercury in honey from Argentina using online sample treatment
    • M.A. Domínguez, M. Grünhut, M.F. Pistonesi, M.S. Di Nezio, and M.E. Centurión Automatic flow-batch system for cold vapor atomic absorption spectroscopy determination of mercury in honey from Argentina using online sample treatment J. Agric. Food Chem. 60 2012 4812 4817
    • (2012) J. Agric. Food Chem. , vol.60 , pp. 4812-4817
    • Domínguez, M.A.1    Grünhut, M.2    Pistonesi, M.F.3    Di Nezio, M.S.4    Centurión, M.E.5
  • 9
    • 79956051589 scopus 로고    scopus 로고
    • The determination of mercury in mushrooms by CV-AAS and ICP-AES techniques
    • G. Jarzynska, and J. Falandysz The determination of mercury in mushrooms by CV-AAS and ICP-AES techniques J. Environ. Sci. Health 46 2011 569 573
    • (2011) J. Environ. Sci. Health , vol.46 , pp. 569-573
    • Jarzynska, G.1    Falandysz, J.2
  • 10
    • 74849097377 scopus 로고    scopus 로고
    • Ion selective electrodes (ISEs) and interferences - A review
    • G. Dimeski, T. Badrick, and A. St John Ion selective electrodes (ISEs) and interferences - a review Clin. Chim. Acta 411 2010 309 317
    • (2010) Clin. Chim. Acta , vol.411 , pp. 309-317
    • Dimeski, G.1    Badrick, T.2    St John, A.3
  • 11
    • 29344458530 scopus 로고    scopus 로고
    • Ion-selective electrodes in drug analysis (a review)
    • E.G. Kulapina, and O.V. Barinova Ion-selective electrodes in drug analysis (a review) Pharm. Chem. J. 31 1997 667 672
    • (1997) Pharm. Chem. J. , vol.31 , pp. 667-672
    • Kulapina, E.G.1    Barinova, O.V.2
  • 12
    • 84987573898 scopus 로고
    • Sensors based on carbon paste in electrochemical analysis: A review with particular emphasis on the period 1990-1993
    • K. Kalcher, J.M. Kauffmann, J. Wang, I. Švancara, K. Vytřas, C. Neuhold, and Z. Yang Sensors based on carbon paste in electrochemical analysis: a review with particular emphasis on the period 1990-1993 Electroanalysis 7 1995 5 22
    • (1995) Electroanalysis , vol.7 , pp. 5-22
    • Kalcher, K.1    Kauffmann, J.M.2    Wang, J.3    Švancara, I.4    Vytřas, K.5    Neuhold, C.6    Yang, Z.7
  • 13
    • 58149382234 scopus 로고    scopus 로고
    • Wang, carbon paste electrodes in facts, numbers, and notes: A review on the occasion of the 50-years jubilee of carbon paste in electrochemistry and electroanalysis
    • K. Švancara, K. Vytřas, A. Kalcher, and J. Walcarius Wang, carbon paste electrodes in facts, numbers, and notes: a review on the occasion of the 50-years jubilee of carbon paste in electrochemistry and electroanalysis Electroanalysis 21 2009 7 28
    • (2009) Electroanalysis , vol.21 , pp. 7-28
    • Švancara, K.1    Vytřas, K.2    Kalcher, A.3    Walcarius, J.4
  • 15
    • 35448951024 scopus 로고    scopus 로고
    • A novel modified carbon paste electrode for potentiometric determination of mercury(II) ion
    • M.H. Mashhadizadeh, M. Talakesh, M. Peste, A. Momeni, H. Hamidian, and M. Mazlum A novel modified carbon paste electrode for potentiometric determination of mercury(II) ion Electroanalysis 18 2006 2174 2179
    • (2006) Electroanalysis , vol.18 , pp. 2174-2179
    • Mashhadizadeh, M.H.1    Talakesh, M.2    Peste, M.3    Momeni, A.4    Hamidian, H.5    Mazlum, M.6
  • 18
    • 0038245105 scopus 로고    scopus 로고
    • Mercury(II) ion-selective polymeric membrane sensor based on a recently synthesized Schiff base
    • M.H. Mashhadizadeh, and I. Sheikhshoaie Mercury(II) ion-selective polymeric membrane sensor based on a recently synthesized Schiff base Talanta 60 2003 73 80
    • (2003) Talanta , vol.60 , pp. 73-80
    • Mashhadizadeh, M.H.1    Sheikhshoaie, I.2
  • 19
    • 0345861895 scopus 로고    scopus 로고
    • 2 +-selective membrane potentiometric sensor based on a recently synthesized mercapto compound
    • 2 +-selective membrane potentiometric sensor based on a recently synthesized mercapto compound Electroanalysis 15 2003 23 24
    • (2003) Electroanalysis , vol.15 , pp. 23-24
    • Bagheri, M.1    Mashhadizadeh, M.H.2    Razee, S.3    Momeni, A.4
  • 20
    • 38349190231 scopus 로고    scopus 로고
    • Mercury-selective membrane electrode based on methyl substituted dibenzo tetraphenyl tetraaza macrocycle
    • A.K. Singh, R.P. Singh, and S. Mehtab Mercury-selective membrane electrode based on methyl substituted dibenzo tetraphenyl tetraaza macrocycle J. Incl. Phenom. Macrocycl. Chem. 60 2008 9 15
    • (2008) J. Incl. Phenom. Macrocycl. Chem. , vol.60 , pp. 9-15
    • Singh, A.K.1    Singh, R.P.2    Mehtab, S.3
  • 21
    • 77956429693 scopus 로고    scopus 로고
    • Multi-walled carbon nanotubes-ionic liquid-carbon paste electrode as a super selectivity sensor: Application to potentiometric monitoring of mercury(II) ion
    • H. Khani, M.K. Rofouei, P. Arab, V.K. Gupta, and Z. Vafaei Multi-walled carbon nanotubes-ionic liquid-carbon paste electrode as a super selectivity sensor: application to potentiometric monitoring of mercury(II) ion J. Hazard. Mater. 183 2010 402 409
    • (2010) J. Hazard. Mater. , vol.183 , pp. 402-409
    • Khani, H.1    Rofouei, M.K.2    Arab, P.3    Gupta, V.K.4    Vafaei, Z.5
  • 22
    • 44449132375 scopus 로고    scopus 로고
    • Crystal structure of a novel complex of 1,3-bis(2-methoxybenzene)triazene with mercury(II)
    • M.R. Melardi, M.K. Rofouei, and J. Massomi Crystal structure of a novel complex of 1,3-bis(2-methoxybenzene)triazene with mercury(II) Anal. Sci. 23 2007 67 68
    • (2007) Anal. Sci. , vol.23 , pp. 67-68
    • Melardi, M.R.1    Rofouei, M.K.2    Massomi, J.3
  • 24
    • 77955322704 scopus 로고    scopus 로고
    • Optical sensor based on 1,3-di(2-methoxyphenyl)triazene for monitoring trace amounts of mercury(II) in water samples
    • M.B. Gholivand, M. Mohammadi, and M.K. Rofouei Optical sensor based on 1,3-di(2-methoxyphenyl)triazene for monitoring trace amounts of mercury(II) in water samples Mater. Sci. Eng. C 30 2010 847 852
    • (2010) Mater. Sci. Eng. C , vol.30 , pp. 847-852
    • Gholivand, M.B.1    Mohammadi, M.2    Rofouei, M.K.3
  • 25
    • 67349237202 scopus 로고    scopus 로고
    • Syntheses, structures, thermal behavior and solution studies of two types of Hg(II) complexes with [1,3-di(2-methoxy)benzene]triazene
    • M.K. Rofouei, M. Hematyar, V. Ghoulipour, and J.A. Gharamaleki Syntheses, structures, thermal behavior and solution studies of two types of Hg(II) complexes with [1,3-di(2-methoxy)benzene]triazene Inorg. Chim. Acta 362 2009 3777 3784
    • (2009) Inorg. Chim. Acta , vol.362 , pp. 3777-3784
    • Rofouei, M.K.1    Hematyar, M.2    Ghoulipour, V.3    Gharamaleki, J.A.4
  • 26
    • 80052025111 scopus 로고    scopus 로고
    • Solid phase extraction of ultra-traces mercury(II) using octadecyl silica membrane disks modified by 1,3-bis(2ethoxyphenyl)triazene (EPT) ligand and determination by cold vapor atomic absorption spectrometry
    • M.K. Rofouei, A. Sabouri, A. Ahmadalinezhad, and H. Ferdowsi Solid phase extraction of ultra-traces mercury(II) using octadecyl silica membrane disks modified by 1,3-bis(2ethoxyphenyl)triazene (EPT) ligand and determination by cold vapor atomic absorption spectrometry J. Hazard. Mater. 192 2011 1358 1363
    • (2011) J. Hazard. Mater. , vol.192 , pp. 1358-1363
    • Rofouei, M.K.1    Sabouri, A.2    Ahmadalinezhad, A.3    Ferdowsi, H.4
  • 27
    • 14344256125 scopus 로고    scopus 로고
    • Carbon-nanotube based electrochemical biosensors: A review
    • J. Wang Carbon-nanotube based electrochemical biosensors: a review Electroanalysis 17 2005 7 14
    • (2005) Electroanalysis , vol.17 , pp. 7-14
    • Wang, J.1
  • 28
    • 0346304911 scopus 로고    scopus 로고
    • Nanotubes from carbon
    • P.M. Ajayan Nanotubes from carbon Chem. Rev. 99 1999 1787 1799
    • (1999) Chem. Rev. , vol.99 , pp. 1787-1799
    • Ajayan, P.M.1
  • 29
    • 76449091462 scopus 로고    scopus 로고
    • Review: Carbon nanotube based electrochemical sensors for biomolecules
    • C.B. Jacobs, M.J. Peairs, and B.J. Venton Review: carbon nanotube based electrochemical sensors for biomolecules Anal. Chim. Acta. 662 2010 105 127
    • (2010) Anal. Chim. Acta. , vol.662 , pp. 105-127
    • Jacobs, C.B.1    Peairs, M.J.2    Venton, B.J.3
  • 30
    • 0041782437 scopus 로고    scopus 로고
    • Testing of unmodified carbon paste electrodes
    • I. Švancara, and K. Schachl Testing of unmodified carbon paste electrodes Chem. Listy 93 1999 490 499
    • (1999) Chem. Listy , vol.93 , pp. 490-499
    • Švancara, I.1    Schachl, K.2
  • 31
    • 33947290546 scopus 로고
    • A general purpose curve fitting program for class and research use
    • V.A. Nicely, and J.L. Dye A general purpose curve fitting program for class and research use J. Chem. Educ. 48 1971 443 448
    • (1971) J. Chem. Educ. , vol.48 , pp. 443-448
    • Nicely, V.A.1    Dye, J.L.2
  • 32
    • 77953681235 scopus 로고    scopus 로고
    • Sol-gel-Au nano-particle modified carbon paste electrode for potentiometric determination of sub ppb level of Al(III)
    • M.H. Mashhadizadeh, and H. Khani Sol-gel-Au nano-particle modified carbon paste electrode for potentiometric determination of sub ppb level of Al(III) Anal. Methods 2 2010 24 31
    • (2010) Anal. Methods , vol.2 , pp. 24-31
    • Mashhadizadeh, M.H.1    Khani, H.2
  • 33
    • 77952243023 scopus 로고    scopus 로고
    • Comparative studies of mercapto thiadiazoles self-assembled on gold nanoparticle as ionophores for Cu(II) carbon paste sensors
    • M.H. Mashhadizadeh, H. Khani, A. Foroumadi, and P. Sagharichi Comparative studies of mercapto thiadiazoles self-assembled on gold nanoparticle as ionophores for Cu(II) carbon paste sensors Anal. Chim. Acta. 665 2005 208 214
    • (2005) Anal. Chim. Acta. , vol.665 , pp. 208-214
    • Mashhadizadeh, M.H.1    Khani, H.2    Foroumadi, A.3    Sagharichi, P.4
  • 34
    • 0037533732 scopus 로고    scopus 로고
    • Polymeric membrane and coated graphite samarium(III)selective electrodes based on isopropyl 2-[(isopropoxycarbothioyl) disulfanyl]ethanethioate
    • M. Shamsipur, M. Hosseini, K. Alizadeh, M.M. Eskandari, H. Sharghi, M.F. Mousavi, and M.R. Ganjali Polymeric membrane and coated graphite samarium(III)selective electrodes based on isopropyl 2-[(isopropoxycarbothioyl) disulfanyl]ethanethioate Anal. Chim. Acta. 486 2003 93 99
    • (2003) Anal. Chim. Acta. , vol.486 , pp. 93-99
    • Shamsipur, M.1    Hosseini, M.2    Alizadeh, K.3    Eskandari, M.M.4    Sharghi, H.5    Mousavi, M.F.6    Ganjali, M.R.7
  • 35
    • 2342578719 scopus 로고    scopus 로고
    • Response time of ion-selective electrodes current usage versus IUPAC recommendations
    • C. Maccà Response time of ion-selective electrodes current usage versus IUPAC recommendations Anal. Chim. Acta. 512 2004 183 190
    • (2004) Anal. Chim. Acta. , vol.512 , pp. 183-190
    • Maccà, C.1
  • 37
    • 0037413523 scopus 로고    scopus 로고
    • A mercury(II) ion-selective electrode based on neutral salicylaldehyde thiosemicarbazone
    • R.K. Mahajan, I. Kaur, and T.S. Lobana A mercury(II) ion-selective electrode based on neutral salicylaldehyde thiosemicarbazone Talanta 59 2003 101 105
    • (2003) Talanta , vol.59 , pp. 101-105
    • Mahajan, R.K.1    Kaur, I.2    Lobana, T.S.3
  • 38
    • 0037460633 scopus 로고    scopus 로고
    • New triiodomercurate-modified carbon paste electrode for the potentiometric determination of mercury
    • M.N. Abbas, and G.A.E. Mostafa New triiodomercurate-modified carbon paste electrode for the potentiometric determination of mercury Anal. Chim. Acta. 478 2003 329 335
    • (2003) Anal. Chim. Acta. , vol.478 , pp. 329-335
    • Abbas, M.N.1    Mostafa, G.A.E.2
  • 39
    • 33745107497 scopus 로고    scopus 로고
    • Potentiometric determination of mercury(II) using a tribromo-mercurate-rhodamine B PVC membrane sensor
    • A.M. Othman Potentiometric determination of mercury(II) using a tribromo-mercurate-rhodamine B PVC membrane sensor Int. J. Environ. Anal. Chem. 86 2006 367 379
    • (2006) Int. J. Environ. Anal. Chem. , vol.86 , pp. 367-379
    • Othman, A.M.1
  • 40
    • 68249106350 scopus 로고    scopus 로고
    • Potentiometric determination of mercury(II) ion using a carbon paste electrode modified with substituted thiourea-functionalized highly ordered nanoporous silica
    • M. Javanbakht, F. Divsar, A. Badiei, M.R. Ganjali, P. Norouzi, Gh.M. Ziarani, M. Chaloosi, and A.A. Jahangir Potentiometric determination of mercury(II) ion using a carbon paste electrode modified with substituted thiourea-functionalized highly ordered nanoporous silica Anal. Sci. 25 2009 789 794
    • (2009) Anal. Sci. , vol.25 , pp. 789-794
    • Javanbakht, M.1    Divsar, F.2    Badiei, A.3    Ganjali, M.R.4    Norouzi, P.5    Ziarani Gh., M.6    Chaloosi, M.7    Jahangir, A.A.8
  • 41
    • 67649243495 scopus 로고    scopus 로고
    • A mercury(II) selective sensor based on N, N′-bis(salicylaldehyde)-phenylenediamine as neutral carrier for potentiometric analysis in water samples
    • H.M. Abu-Shawish A mercury(II) selective sensor based on N, N′-bis(salicylaldehyde)-phenylenediamine as neutral carrier for potentiometric analysis in water samples J. Hazard. Mater. 167 2009 602 608
    • (2009) J. Hazard. Mater. , vol.167 , pp. 602-608
    • Abu-Shawish, H.M.1
  • 42
    • 18844399095 scopus 로고    scopus 로고
    • A highly selective mercury electrode based on a diamine donor ligand
    • V.K. Gupta, S. Chandrab, and H. Lang A highly selective mercury electrode based on a diamine donor ligand Talanta 66 2005 575 580
    • (2005) Talanta , vol.66 , pp. 575-580
    • Gupta, V.K.1    Chandrab, S.2    Lang, H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.