메뉴 건너뛰기




Volumn 41, Issue 12, 2014, Pages

Deformable image registration based automatic CT-to-CT contour propagation for head and neck adaptive radiotherapy in the routine clinical setting

Author keywords

adaptive radiotherapy; automatic contouring; contour evaluation; contour propagation; deformable image registration

Indexed keywords

COMPUTERIZED TOMOGRAPHY; IMAGE REGISTRATION; RADIOTHERAPY;

EID: 84912535682     PISSN: 00942405     EISSN: 24734209     Source Type: Journal    
DOI: 10.1118/1.4901409     Document Type: Article
Times cited : (86)

References (28)
  • 1
    • 0035889335 scopus 로고    scopus 로고
    • Intensity-modulated radiotherapy: Current status and issues of interest
    • Intensity Modulated Radiation Therapy Collaborative Working Group, "," .
    • Intensity Modulated Radiation Therapy Collaborative Working Group, " Intensity-modulated radiotherapy: Current status and issues of interest," Int. J. Radiat. Oncol., Biol., Phys. 51 (4), 880-914 (2001). 10.1016/S0360-3016(01)01749-7
    • (2001) Int. J. Radiat. Oncol., Biol., Phys. , vol.51 , Issue.4 , pp. 880-914
  • 2
    • 0041564120 scopus 로고    scopus 로고
    • Intensity-modulated radiation therapy for head-and-neck cancer: The UCSF experience focusing on target volume delineation
    • N. Lee, P. Xia, N. J. Fischbein, P. Akazawa, C. Akazawa, and J. M. Quivey, " Intensity-modulated radiation therapy for head-and-neck cancer: The UCSF experience focusing on target volume delineation," Int. J. Radiat. Oncol., Biol., Phys. 57 (1), 49-60 (2003). 10.1016/S0360-3016(03)00405-X
    • (2003) Int. J. Radiat. Oncol., Biol., Phys. , vol.57 , Issue.1 , pp. 49-60
    • Lee, N.1    Xia, P.2    Fischbein, N.J.3    Akazawa, P.4    Akazawa, C.5    Quivey, J.M.6
  • 3
    • 84860868459 scopus 로고    scopus 로고
    • Current progress in adaptive radiation therapy for head and neck cancer
    • D. L. Schwartz, " Current progress in adaptive radiation therapy for head and neck cancer," Curr. Oncol. Rep. 14 (2), 139-147 (2012). 10.1007/s11912-012-0221-4
    • (2012) Curr. Oncol. Rep. , vol.14 , Issue.2 , pp. 139-147
    • Schwartz, D.L.1
  • 4
    • 77249116279 scopus 로고    scopus 로고
    • Adaptive radiotherapy of head and neck cancer
    • P. Castadot, J. A. Lee, X. Geets, and V. Grégoire, " Adaptive radiotherapy of head and neck cancer," Semin. Radiat. Oncol. 20 (2), 84-93 (2010). 10.1016/j.semradonc.2009.11.002
    • (2010) Semin. Radiat. Oncol. , vol.20 , Issue.2 , pp. 84-93
    • Castadot, P.1    Lee, J.A.2    Geets, X.3    Grégoire, V.4
  • 6
    • 77956819801 scopus 로고    scopus 로고
    • Adaptive radiation therapy for head and neck cancer - Can an old goal evolve into a new standard?
    • D. L. Schwartz and L. Dong, " Adaptive radiation therapy for head and neck cancer-Can an old goal evolve into a new standard?   J. Oncol. 690595 (2011). 10.1155/2011/690595
    • (2011) J. Oncol.
    • Schwartz, D.L.1    Dong, L.2
  • 8
    • 14844283770 scopus 로고    scopus 로고
    • Use of deformed intensity distributions for on-line modifications of image-guided IMRT to account for interfractional anatomical changes
    • R. Mohan, X. Zhang, H. Wang, Y. Kang, X. Wang, H. Liu, K. K. Ang, D. Kuban, and L. Dong, " Use of deformed intensity distributions for on-line modifications of image-guided IMRT to account for interfractional anatomical changes," Int. J. Radiat. Oncol., Biol., Phys. 61 (4), 1258-1266 (2005). 10.1016/j.ijrobp.2004.11.033
    • (2005) Int. J. Radiat. Oncol., Biol., Phys. , vol.61 , Issue.4 , pp. 1258-1266
    • Mohan, R.1    Zhang, X.2    Wang, H.3    Kang, Y.4    Wang, X.5    Liu, H.6    Ang, K.K.7    Kuban, D.8    Dong, L.9
  • 9
    • 34247869928 scopus 로고    scopus 로고
    • Automatic delineation of on-line head and neck computed tomography images: Toward on-line adaptive radiotherapy
    • T. Zhang, Y. Chi, E. Meldolesi, and D. Yan D, " Automatic delineation of on-line head and neck computed tomography images: Toward on-line adaptive radiotherapy," Int. J. Radiat. Oncol., Biol., Phys. 68 (2), 522-530 (2007). 10.1016/j.ijrobp.2007.01.038
    • (2007) Int. J. Radiat. Oncol., Biol., Phys. , vol.68 , Issue.2 , pp. 522-530
    • Zhang, T.1    Chi, Y.2    Meldolesi, E.3    Yan, D.D.4
  • 11
    • 52949153932 scopus 로고    scopus 로고
    • Feature-based rectal contour propagation from planning CT to cone beam CT
    • Y. Xie, M. Chao, P. Lee, and L. Xing, " Feature-based rectal contour propagation from planning CT to cone beam CT," Med. Phys. 35 (10), 4450-4459 (2008). 10.1118/1.2975230
    • (2008) Med. Phys. , vol.35 , Issue.10 , pp. 4450-4459
    • Xie, Y.1    Chao, M.2    Lee, P.3    Xing, L.4
  • 12
    • 63549096561 scopus 로고    scopus 로고
    • A framework for evaluation of deformable image registration spatial accuracy using large landmark point sets
    • R. Castillo, E. Castillo, R. Guerra, V. E. Johnson, T. McPhail, A. K. Garg, and T. Guerrero, " A framework for evaluation of deformable image registration spatial accuracy using large landmark point sets," Phys. Med. Biol. 54 (7), 1849-1870 (2009). 10.1088/0031-9155/54/7/001
    • (2009) Phys. Med. Biol. , vol.54 , Issue.7 , pp. 1849-1870
    • Castillo, R.1    Castillo, E.2    Guerra, R.3    Johnson, V.E.4    McPhail, T.5    Garg, A.K.6    Guerrero, T.7
  • 14
    • 53049093441 scopus 로고    scopus 로고
    • Comparison of 12 deformable registration strategies in adaptive radiation therapy for the treatment of head and neck tumors
    • P. Castadot, J. A. Lee, A. Parraga, X. Geets, B. Macq, and V. Grégoire, " Comparison of 12 deformable registration strategies in adaptive radiation therapy for the treatment of head and neck tumors," Radiother. Oncol. 89 (1), 1-12 (2008). 10.1016/j.radonc.2008.04.010
    • (2008) Radiother. Oncol. , vol.89 , Issue.1 , pp. 1-12
    • Castadot, P.1    Lee, J.A.2    Parraga, A.3    Geets, X.4    MacQ, B.5    Grégoire, V.6
  • 15
    • 77749240275 scopus 로고    scopus 로고
    • Analysis of deformable image registration accuracy using computational modeling
    • H. Zhong, J. Kim, and I. J. Chetty, " Analysis of deformable image registration accuracy using computational modeling," Med. Phys. 37 (3), 970-979 (2010). 10.1118/1.3302141
    • (2010) Med. Phys. , vol.37 , Issue.3 , pp. 970-979
    • Zhong, H.1    Kim, J.2    Chetty, I.J.3
  • 16
    • 84876188881 scopus 로고    scopus 로고
    • Site-specific deformable imaging registration algorithm selection using patient-based simulated deformations
    • (10p).
    • K. Nie, C. Chuang, N. Kirby, S. Braunstein, and J. Pouliot, " Site-specific deformable imaging registration algorithm selection using patient-based simulated deformations," Med. Phys. 40 (4), 041911 (10pp.) (2013). 10.1118/1.4793723
    • (2013) Med. Phys. , vol.40 , Issue.4
    • Nie, K.1    Chuang, C.2    Kirby, N.3    Braunstein, S.4    Pouliot, J.5
  • 17
    • 84872046036 scopus 로고    scopus 로고
    • The need for application-based adaptation of deformable image registration
    • (10p).
    • N. Kirby, C. Chuang, U. Ueda, and J. Pouliot, " The need for application-based adaptation of deformable image registration," Med. Phys. 40 (1), 011702 (10pp.) (2013). 10.1118/1.4769114
    • (2013) Med. Phys. , vol.40 , Issue.1
    • Kirby, N.1    Chuang, C.2    Ueda, U.3    Pouliot, J.4
  • 19
    • 84861092866 scopus 로고    scopus 로고
    • Evaluation of deformable image coregistration in adaptive dose painting by numbers for head-and-neck cancer
    • L. A. M. Olteanu, I. Madani, W. Neve, T. Vercauteren, and W. De Gersem, " Evaluation of deformable image coregistration in adaptive dose painting by numbers for head-and-neck cancer," Int. J. Radiat. Oncol., Biol., Phys. 83 (2), 696-703 (2012). 10.1016/j.ijrobp.2011.07.037
    • (2012) Int. J. Radiat. Oncol., Biol., Phys. , vol.83 , Issue.2 , pp. 696-703
    • Olteanu, L.A.M.1    Madani, I.2    Neve, W.3    Vercauteren, T.4    De Gersem, W.5
  • 21
    • 84866285679 scopus 로고    scopus 로고
    • Systematic evaluation of three different commercial software solutions for automatic segmentation for adaptive therapy in head-and-neck, prostate and pleural cancer
    • (16p).
    • M. La Macchia, F. Fellin, M. Amichetti, M. Cianchetti, S. Gianolini, V. Paola, A. J. Lomax, and L. Widesott, " Systematic evaluation of three different commercial software solutions for automatic segmentation for adaptive therapy in head-and-neck, prostate and pleural cancer," Radiat. Oncol. 7 (160) (16pp.) (2012). 10.1186/1748-717X-7-160
    • (2012) Radiat. Oncol. , vol.7 , Issue.160
    • La MacChia, M.1    Fellin, F.2    Amichetti, M.3    Cianchetti, M.4    Gianolini, S.5    Paola, V.6    Lomax, A.J.7    Widesott, L.8
  • 22
    • 0033169211 scopus 로고    scopus 로고
    • Nonrigid registration using free-form deformations: Application to breast MR images
    • D. Rueckert, L. I. Sonoda, C. Hayes, D. L. Hill, M. O. Leach, and D. J. Hawkes, " Nonrigid registration using free-form deformations: Application to breast MR images," IEEE Trans. Med. Imaging 18 (8), 712-721 (1999). 10.1109/42.796284
    • (1999) IEEE Trans. Med. Imaging , vol.18 , Issue.8 , pp. 712-721
    • Rueckert, D.1    Sonoda, L.I.2    Hayes, C.3    Hill, D.L.4    Leach, M.O.5    Hawkes, D.J.6
  • 24
    • 0032153006 scopus 로고    scopus 로고
    • Image matching as a diffusion process: An analogy with Maxwell's demons
    • J. P. Thirion, " Image matching as a diffusion process: An analogy with Maxwell's demons," Med. Image Anal. 2 (3), 243-260 (1998). 10.1016/S1361-8415(98)80022-4
    • (1998) Med. Image Anal. , vol.2 , Issue.3 , pp. 243-260
    • Thirion, J.P.1
  • 25
    • 0031106962 scopus 로고    scopus 로고
    • Multimodality image registration by maximization of mutual information
    • F. Maes, A. Collignon, D. Vandermeulen, G. Marchal, and P. Suetens, " Multimodality image registration by maximization of mutual information," IEEE Trans. Med. Imaging 16 (2), 187-198 (1997). 10.1109/42.563664
    • (1997) IEEE Trans. Med. Imaging , vol.16 , Issue.2 , pp. 187-198
    • Maes, F.1    Collignon, A.2    Vandermeulen, D.3    Marchal, G.4    Suetens, P.5
  • 26
    • 73849116467 scopus 로고    scopus 로고
    • Elastix: A toolbox for intensity based medical image registration
    • S. Klein, M. Staring, K. Murphy, M. A. Viergever, and J. P. Pluim, " Elastix: A toolbox for intensity based medical image registration," IEEE Trans. Med. Imaging 29 (1), 196-205 (2010). 10.1109/TMI.2009.2035616
    • (2010) IEEE Trans. Med. Imaging , vol.29 , Issue.1 , pp. 196-205
    • Klein, S.1    Staring, M.2    Murphy, K.3    Viergever, M.A.4    Pluim, J.P.5
  • 28
    • 84880059991 scopus 로고    scopus 로고
    • The role of regularization in deformable image registration for head and neck adaptive radiotherapy
    • D. Ciardo, M. Peroni, M. Riboldi, D. Alterio, G. Baroni, and R. Orecchia, " The role of regularization in deformable image registration for head and neck adaptive radiotherapy," Technol. Cancer Res. Treat. 12, 333-339 (2013). 10.7785/tcrt.2012.500327
    • (2013) Technol. Cancer Res. Treat. , vol.12 , pp. 333-339
    • Ciardo, D.1    Peroni, M.2    Riboldi, M.3    Alterio, D.4    Baroni, G.5    Orecchia, R.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.