메뉴 건너뛰기




Volumn 89, Issue 1, 2008, Pages 81-88

Evaluation of geometric changes of parotid glands during head and neck cancer radiotherapy using daily MVCT and automatic deformable registration

Author keywords

Daily MVCT; Deformable image registration; Head and neck cancer; Parotid gland changes

Indexed keywords

ACCURACY; ALGORITHM; ARTICLE; CLINICAL ARTICLE; COMPARATIVE STUDY; DOSIMETRY; GEOMETRY; HEAD AND NECK CANCER; HUMAN; HUMAN TISSUE; MEGAVOLTAGE RADIOTHERAPY; PAROTID GLAND; PRIORITY JOURNAL; QUALITATIVE ANALYSIS;

EID: 53049094349     PISSN: 01678140     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.radonc.2008.07.006     Document Type: Article
Times cited : (106)

References (16)
  • 1
    • 14844337004 scopus 로고    scopus 로고
    • Intensity modulated radiotherapy for head and neck cancer: evidence for preserved salivary gland function
    • Saarilahti K., Kouri M., Collan J., et al. Intensity modulated radiotherapy for head and neck cancer: evidence for preserved salivary gland function. Radiother Oncol 74 (2005) 251-258
    • (2005) Radiother Oncol , vol.74 , pp. 251-258
    • Saarilahti, K.1    Kouri, M.2    Collan, J.3
  • 2
    • 33646491060 scopus 로고    scopus 로고
    • Sparing of the submandibular glands by intensity modulated radiotherapy in the treatment of head and neck cancer
    • Saarilahti K., Kouri M., Collan J., et al. Sparing of the submandibular glands by intensity modulated radiotherapy in the treatment of head and neck cancer. Radiother Oncol 78 (2006) 270-275
    • (2006) Radiother Oncol , vol.78 , pp. 270-275
    • Saarilahti, K.1    Kouri, M.2    Collan, J.3
  • 3
    • 33748945694 scopus 로고    scopus 로고
    • Daily variations in delivered doses in patients treated with radiotherapy for localized prostate cancer
    • Kupelian P.A., Langen K.M., Zeidan O.A., et al. Daily variations in delivered doses in patients treated with radiotherapy for localized prostate cancer. Int J Radiat Oncol Biol Phys 66 (2006) 876-882
    • (2006) Int J Radiat Oncol Biol Phys , vol.66 , pp. 876-882
    • Kupelian, P.A.1    Langen, K.M.2    Zeidan, O.A.3
  • 4
    • 24644479041 scopus 로고    scopus 로고
    • The use of megavoltage CT (MVCT) images for dose recomputations
    • Langen K.M., Meeks S.L., Poole D.O., et al. The use of megavoltage CT (MVCT) images for dose recomputations. Phys Med Biol 50 (2005) 4259-4276
    • (2005) Phys Med Biol , vol.50 , pp. 4259-4276
    • Langen, K.M.1    Meeks, S.L.2    Poole, D.O.3
  • 5
    • 33847250480 scopus 로고    scopus 로고
    • Dose calculation using megavoltage cone-beam CT
    • Morin O., Chen J., Aubin M., et al. Dose calculation using megavoltage cone-beam CT. Int J Radiat Oncol Biol Phys 67 (2007) 1201-1210
    • (2007) Int J Radiat Oncol Biol Phys , vol.67 , pp. 1201-1210
    • Morin, O.1    Chen, J.2    Aubin, M.3
  • 6
    • 4344692365 scopus 로고    scopus 로고
    • Fast free-form deformable registration via calculus of variations
    • Lu W., Chen M.L., Olivera G.H., Ruchala K.J., and Mackie T.R. Fast free-form deformable registration via calculus of variations. Phys Med Biol 49 (2004) 3067-3087
    • (2004) Phys Med Biol , vol.49 , pp. 3067-3087
    • Lu, W.1    Chen, M.L.2    Olivera, G.H.3    Ruchala, K.J.4    Mackie, T.R.5
  • 8
    • 34247869928 scopus 로고    scopus 로고
    • Automatic delineation of on-line head-and-neck computed tomography images: toward on-line adaptive radiotherapy
    • Zhang T., Chi Y., Meldolesi E., and Yan D. Automatic delineation of on-line head-and-neck computed tomography images: toward on-line adaptive radiotherapy. Int J Radiat Oncol Biol Phys 68 (2007) 522-530
    • (2007) Int J Radiat Oncol Biol Phys , vol.68 , pp. 522-530
    • Zhang, T.1    Chi, Y.2    Meldolesi, E.3    Yan, D.4
  • 9
    • 34347391909 scopus 로고    scopus 로고
    • Technical note: a physical phantom for assessment of accuracy of deformable alignment algorithms
    • Kashani R., Hub M., Kessler M.L., and Balter J.M. Technical note: a physical phantom for assessment of accuracy of deformable alignment algorithms. Med Phys 34 (2007) 2785-2788
    • (2007) Med Phys , vol.34 , pp. 2785-2788
    • Kashani, R.1    Hub, M.2    Kessler, M.L.3    Balter, J.M.4
  • 10
    • 33747610756 scopus 로고    scopus 로고
    • Deformable registration of the planning image (kVCT) and the daily images (MVCT) for adaptive radiation therapy
    • Lu W.G., Olivera G.H., Chen Q., et al. Deformable registration of the planning image (kVCT) and the daily images (MVCT) for adaptive radiation therapy. Phys Med Biol 51 (2006) 4357-4374
    • (2006) Phys Med Biol , vol.51 , pp. 4357-4374
    • Lu, W.G.1    Olivera, G.H.2    Chen, Q.3
  • 11
    • 53049110196 scopus 로고    scopus 로고
    • Commissioning and validation of a beam model for calculating megavoltage CT dose from imaging with a helical tomotherapy unit
    • Shah A., Langen K., Meeks S., et al. Commissioning and validation of a beam model for calculating megavoltage CT dose from imaging with a helical tomotherapy unit. Med Phys 34 (2007) 2608
    • (2007) Med Phys , vol.34 , pp. 2608
    • Shah, A.1    Langen, K.2    Meeks, S.3
  • 12
    • 53049087614 scopus 로고    scopus 로고
    • Green G. An essay on the application of mathematical analysis to the theories of electricity and magnetism. Nottingham: Wheelhouse; 1828.
    • Green G. An essay on the application of mathematical analysis to the theories of electricity and magnetism. Nottingham: Wheelhouse; 1828.
  • 13
    • 3042520594 scopus 로고    scopus 로고
    • Quantification of volumetric and geometric changes occurring during fractionated radiotherapy for head-and-neck cancer using an integrated CT/linear accelerator system
    • Barker J.L., Garden A.S., Ang K.K., et al. Quantification of volumetric and geometric changes occurring during fractionated radiotherapy for head-and-neck cancer using an integrated CT/linear accelerator system. Int J Radiat Oncol Biol Phys 59 (2004) 960-970
    • (2004) Int J Radiat Oncol Biol Phys , vol.59 , pp. 960-970
    • Barker, J.L.1    Garden, A.S.2    Ang, K.K.3
  • 14
    • 34447276902 scopus 로고    scopus 로고
    • Spatial and dosimetric variability of organs at risk in head-and-neck intensity-modulated radiotherapy
    • Robar J.L., Day A., Clancey J., et al. Spatial and dosimetric variability of organs at risk in head-and-neck intensity-modulated radiotherapy. Int J Radiat Oncol Biol Phys 68 (2007) 1121-1130
    • (2007) Int J Radiat Oncol Biol Phys , vol.68 , pp. 1121-1130
    • Robar, J.L.1    Day, A.2    Clancey, J.3
  • 15
    • 33646256149 scopus 로고    scopus 로고
    • Prostate contouring uncertainty in megavoltage computed tomography images acquired with a helical tomotherapy unit during image-guided radiation therapy
    • Song W.Y., Chiu B., Bauman G.S., et al. Prostate contouring uncertainty in megavoltage computed tomography images acquired with a helical tomotherapy unit during image-guided radiation therapy. Int J Radiat Oncol Biol Phys 65 (2006) 595-607
    • (2006) Int J Radiat Oncol Biol Phys , vol.65 , pp. 595-607
    • Song, W.Y.1    Chiu, B.2    Bauman, G.S.3
  • 16
    • 35448993585 scopus 로고    scopus 로고
    • Parotid gland dose in intensity-modulated radiotherapy for head and neck cancer: is what you plan what you get?
    • O'Daniel J.C., Garden A.S., Schwartz D.L., et al. Parotid gland dose in intensity-modulated radiotherapy for head and neck cancer: is what you plan what you get?. Int J Radiat Oncol Biol Phys 69 (2007) 1290-1296
    • (2007) Int J Radiat Oncol Biol Phys , vol.69 , pp. 1290-1296
    • O'Daniel, J.C.1    Garden, A.S.2    Schwartz, D.L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.