메뉴 건너뛰기




Volumn 208, Issue , 2015, Pages 491-496

Design of a novel magnetic particles based electrochemical biosensor for organophosphate insecticide detection in flow injection analysis

Author keywords

Automated flow system; Magnetic nanobeads; Organophosphate insecticide; Renewable interface; Reproducible sensing surface

Indexed keywords

BIOSENSORS; INSECTICIDES; NANOPARTICLES; NANOSTRUCTURED MATERIALS; POROUS SILICON; SOL-GELS;

EID: 84912143335     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2014.11.069     Document Type: Article
Times cited : (36)

References (26)
  • 1
    • 84887530408 scopus 로고    scopus 로고
    • Ultrasensitive protein detection: A case for microfluidic magnetic bead-based assays
    • H.C. Tekin, M.A.M Gijs, Ultrasensitive protein detection: a case for microfluidic magnetic bead-based assays, Lab Chip 13 (2013) 4711-4739.
    • (2013) Lab Chip , vol.13 , pp. 4711-4739
    • Tekin, H.C.1    Gijs, M.A.M.2
  • 2
    • 0142135898 scopus 로고    scopus 로고
    • Dual-function microanalytical device by in situ photolithographic grafting of porous polymer monolith: Integrating solid-phase extraction and enzymatic digestion for peptide mass mapping
    • D.S. Peterson, T. Rohr, F. Svec, J.M.J. Frechet, Dual-function microanalytical device by in situ photolithographic grafting of porous polymer monolith: integrating solid-phase extraction and enzymatic digestion for peptide mass mapping, Anal. Chem. 75 (2003) 5328-5335.
    • (2003) Anal. Chem. , vol.75 , pp. 5328-5335
    • Peterson, D.S.1    Rohr, T.2    Svec, F.3    Frechet, J.M.J.4
  • 3
    • 0037060169 scopus 로고    scopus 로고
    • Improved performance in silicon enzyme microreactors obtained by homogeneous porous silicon carrier matrix
    • M. Bengtsson, S. Ekstrom, G. Marko-Varga, T. Laurell, Improved performance in silicon enzyme microreactors obtained by homogeneous porous silicon carrier matrix, Talanta 56 (2002) 341-353.
    • (2002) Talanta , vol.56 , pp. 341-353
    • Bengtsson, M.1    Ekstrom, S.2    Marko-Varga, G.3    Laurell, T.4
  • 4
    • 77958033162 scopus 로고    scopus 로고
    • Lab-on-a-chip for analysis of triglycerides based on a replaceable enzyme carrier using magnetic beads
    • S.P. Chen, X.D. Yu, J.J. Xu, H.Y. Chen, Lab-on-a-chip for analysis of triglycerides based on a replaceable enzyme carrier using magnetic beads, Analyst 135 (2010) 2979-2986.
    • (2010) Analyst , vol.135 , pp. 2979-2986
    • Chen, S.P.1    Yu, X.D.2    Xu, J.J.3    Chen, H.Y.4
  • 5
    • 84875455140 scopus 로고    scopus 로고
    • Development of an automated flow-based electrochemical aptasensor for on-line detection of ochratoxin A
    • A. Rhouati, A. Hayat, D.B. Hernandez, Z. Meraihi, R. Munoz, J.L. Marty, Development of an automated flow-based electrochemical aptasensor for on-line detection of ochratoxin A, Sens. Actuators B: Chem. 176 (2013) 1160-1166.
    • (2013) Sens. Actuators B: Chem. , vol.176 , pp. 1160-1166
    • Rhouati, A.1    Hayat, A.2    Hernandez, D.B.3    Meraihi, Z.4    Munoz, R.5    Marty, J.L.6
  • 6
    • 84855776506 scopus 로고    scopus 로고
    • A novel automated.Ow-based biosensor for the determination of organophosphate pesticides in milk
    • R.K. Mishra, R.B. Dominguez, S. Bhand, R. Munoz, J.L. Marty, A novel automated .ow-based biosensor for the determination of organophosphate pesticides in milk, Biosens. Bioelectron. 32 (2012) 56-61.
    • (2012) Biosens. Bioelectron. , vol.32 , pp. 56-61
    • Mishra, R.K.1    Dominguez, R.B.2    Bhand, S.3    Munoz, R.4    Marty, J.L.5
  • 7
    • 77953012150 scopus 로고    scopus 로고
    • Functionalization strategies for protease immobilization on magnetic nanoparticles
    • D. Li, W.Y. Teoh, J.J. Gooding, C. Selomulya, R. Amal, Functionalization strategies for protease immobilization on magnetic nanoparticles, Adv. Funct. Mater. 20 (2010) 1767-1777.
    • (2010) Adv. Funct. Mater. , vol.20 , pp. 1767-1777
    • Li, D.1    Teoh, W.Y.2    Gooding, J.J.3    Selomulya, C.4    Amal, R.5
  • 8
    • 0242486387 scopus 로고    scopus 로고
    • Glucose sensor for flow injection analysis of serum glucose based on immobilization of glucose oxidase in titania sol-gel membrane
    • J.H. Yu, S.Q. Liu, H.X. Ju, Glucose sensor for flow injection analysis of serum glucose based on immobilization of glucose oxidase in titania sol-gel membrane, Biosens. Bioelectron. 19 (2003) 401-409.
    • (2003) Biosens. Bioelectron. , vol.19 , pp. 401-409
    • Yu, J.H.1    Liu, S.Q.2    Ju, H.X.3
  • 9
    • 78650039937 scopus 로고    scopus 로고
    • Review on the use of enzymes for the detection of organochlorine organophosphate and carbamate pesticides in the environment
    • J.S. Van Dyk, B. Pletschke, Review on the use of enzymes for the detection of organochlorine organophosphate and carbamate pesticides in the environment, Chemosphere 82 (2011) 291-307.
    • (2011) Chemosphere , vol.82 , pp. 291-307
    • Van Dyk, J.S.1    Pletschke, B.2
  • 10
    • 0031754195 scopus 로고    scopus 로고
    • Review of health consequences from high-, intermediate- and low-level exposure to organophosphorus nerve agents
    • M.A. Brown, K.A. Brix, Review of health consequences from high-, intermediate- and low-level exposure to organophosphorus nerve agents, J. Appl. Toxicol. 18 (1998) 393-408.
    • (1998) J. Appl. Toxicol. , vol.18 , pp. 393-408
    • Brown, M.A.1    Brix, K.A.2
  • 11
    • 0036173305 scopus 로고    scopus 로고
    • The degradation of organophosphorus pesticides in natural waters: A critical review
    • S.O. Pehkonen, Q. Zhang, The degradation of organophosphorus pesticides in natural waters: a critical review, Crit. Rev. Environ. Sci. Technol. 32 (2002) 17-72.
    • (2002) Crit. Rev. Environ. Sci. Technol. , vol.32 , pp. 17-72
    • Pehkonen, S.O.1    Zhang, Q.2
  • 12
    • 32644444408 scopus 로고    scopus 로고
    • Twenty years research in cholinesterase biosensors: From basic research to practical applications
    • S. Andreescu, J.L. Marty, Twenty years research in cholinesterase biosensors: from basic research to practical applications, Biomol. Eng. 23 (2006) 1-15.
    • (2006) Biomol. Eng. , vol.23 , pp. 1-15
    • Andreescu, S.1    Marty, J.L.2
  • 13
    • 77956172992 scopus 로고    scopus 로고
    • Biosensors based on cholinesterase inhibition for insecticides, nerve agents and aflatoxin B-1 detection (review)
    • F. Arduini, A. Amine, D. Moscone, G. Palleschi, Biosensors based on cholinesterase inhibition for insecticides, nerve agents and aflatoxin B-1 detection (review), Microchim. Acta 170 (2010) 193-214.
    • (2010) Microchim. Acta , vol.170 , pp. 193-214
    • Arduini, F.1    Amine, A.2    Moscone, D.3    Palleschi, G.4
  • 14
    • 31044455163 scopus 로고    scopus 로고
    • Enzyme inhibition-based biosensors for food safety and environmental monitoring
    • A. Amine, H. Mohammadi, I. Bourais, G. Palleschi, Enzyme inhibition-based biosensors for food safety and environmental monitoring, Biosens. Bioelectron. 21 (2006) 1405-1423.
    • (2006) Biosens. Bioelectron. , vol.21 , pp. 1405-1423
    • Amine, A.1    Mohammadi, H.2    Bourais, I.3    Palleschi, G.4
  • 15
    • 67649588695 scopus 로고    scopus 로고
    • Nanomaterials - acetylcholinesterase enzyme matrices for organophosphorus pesticides electrochemical sensors: A review
    • A.P. Periasamy, Y. Umasankar, S.M. Chen, Nanomaterials - acetylcholinesterase enzyme matrices for organophosphorus pesticides electrochemical sensors: a review, Sensors 9 (2009) 4034-4055.
    • (2009) Sensors , vol.9 , pp. 4034-4055
    • Periasamy, A.P.1    Umasankar, Y.2    Chen, S.M.3
  • 16
    • 84869087896 scopus 로고    scopus 로고
    • Electrochemical biosensors based on magnetic micro/nano particles
    • Y. Xu, E. Wang, Electrochemical biosensors based on magnetic micro/nano particles, Electrochim. Acta 84 (2012) 62-73.
    • (2012) Electrochim. Acta , vol.84 , pp. 62-73
    • Xu, Y.1    Wang, E.2
  • 17
    • 62749123001 scopus 로고    scopus 로고
    • Lab-on-a-chip for ultrasensitive detection of carbofuran by enzymatic inhibition with replacement of enzyme using magnetic beads
    • X. Llopis, M. Pumera, S. Alegret, A. Merkoci, Lab-on-a-chip for ultrasensitive detection of carbofuran by enzymatic inhibition with replacement of enzyme using magnetic beads, Lab Chip 9 (2009) 213-218.
    • (2009) Lab Chip , vol.9 , pp. 213-218
    • Llopis, X.1    Pumera, M.2    Alegret, S.3    Merkoci, A.4
  • 18
    • 33750691668 scopus 로고    scopus 로고
    • Trends in flow-based biosensing systems for pesticide assessment
    • B. Prieto-Simon, M. Campas, S. Andreescu, J.-L. Marty, Trends in flow-based biosensing systems for pesticide assessment, Sensors 6 (2006) 1161-1186.
    • (2006) Sensors , vol.6 , pp. 1161-1186
    • Prieto-Simon, B.1    Campas, M.2    Andreescu, S.3    Marty, J.-L.4
  • 19
    • 0037031233 scopus 로고    scopus 로고
    • Immobilization of acetylcholinesterase on screen-printed electrodes: Comparative study between three immobilization methods and applications to the detection of organophosphorus insecticides
    • S. Andreescu, L. Barthelmebs, J.L. Marty, Immobilization of acetylcholinesterase on screen-printed electrodes: comparative study between three immobilization methods and applications to the detection of organophosphorus insecticides, Anal. Chim. Acta 464 (2002) 171-180.
    • (2002) Anal. Chim. Acta , vol.464 , pp. 171-180
    • Andreescu, S.1    Barthelmebs, L.2    Marty, J.L.3
  • 20
  • 21
    • 35348914660 scopus 로고    scopus 로고
    • Highly sensitive detection of organophosphorus insecticides using magnetic microbeads and genetically engineered acetylcholinesterase
    • G. Istamboulie, S. Andreescu, J.-L. Marty, T. Noguer, Highly sensitive detection of organophosphorus insecticides using magnetic microbeads and genetically engineered acetylcholinesterase, Biosens. Bioelectron. 23 (2007) 506-512.
    • (2007) Biosens. Bioelectron. , vol.23 , pp. 506-512
    • Istamboulie, G.1    Andreescu, S.2    Marty, J.-L.3    Noguer, T.4
  • 22
    • 27744510741 scopus 로고    scopus 로고
    • Rapid and reagent-saving immunoassay using innovative stirring actions of magnetic beads in microreactors in the sequential injection mode
    • K. Tanaka, H. Imagawa, Rapid and reagent-saving immunoassay using innovative stirring actions of magnetic beads in microreactors in the sequential injection mode, Talanta 68 (2005) 437-441.
    • (2005) Talanta , vol.68 , pp. 437-441
    • Tanaka, K.1    Imagawa, H.2
  • 23
    • 0034775620 scopus 로고    scopus 로고
    • Development of a quantitative relationship between inhibition percentage and both incubation time and inhibitor concentration for inhibition biosensors - theoretical and practical considerations
    • S. Zhang, H. Zhao, R. John, Development of a quantitative relationship between inhibition percentage and both incubation time and inhibitor concentration for inhibition biosensors - theoretical and practical considerations, Biosens. Bioelectron. 16 (2001) 1119-1126.
    • (2001) Biosens. Bioelectron. , vol.16 , pp. 1119-1126
    • Zhang, S.1    Zhao, H.2    John, R.3
  • 24
    • 0036038874 scopus 로고    scopus 로고
    • Flow-injection amperometric determination of pesticides on the basis of their inhibition of immobilized acetylcholinesterases of different origin
    • G. Jeanty, A. Wojciechowska, J.L. Marty, M. Trojanowicz, Flow-injection amperometric determination of pesticides on the basis of their inhibition of immobilized acetylcholinesterases of different origin, Anal. Bioanal. Chem. 373 (2002) 691-695.
    • (2002) Anal. Bioanal. Chem. , vol.373 , pp. 691-695
    • Jeanty, G.1    Wojciechowska, A.2    Marty, J.L.3    Trojanowicz, M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.