메뉴 건너뛰기




Volumn 22, Issue 12, 2014, Pages 3127-3134

Computer-assisted surgery improves rotational positioning of the femoral component but not the tibial component in total knee arthroplasty

Author keywords

Alignment; Femoral rotation; Navigation; Tibial rotation; Total knee arthroplasty

Indexed keywords

AGED; BODY POSTURE; COMPARATIVE STUDY; COMPUTER ASSISTED SURGERY; COMPUTER ASSISTED TOMOGRAPHY; CONTROLLED STUDY; FEMALE; FEMUR; HUMAN; JOINT DISEASES; KNEE; KNEE ARTHROPLASTY; KNEE PROSTHESIS; MALE; MIDDLE AGED; PATHOPHYSIOLOGY; PROCEDURES; PROSPECTIVE STUDY; RADIOGRAPHY; RANDOMIZED CONTROLLED TRIAL; ROTATION; TIBIA;

EID: 84911383087     PISSN: 09422056     EISSN: 14337347     Source Type: Journal    
DOI: 10.1007/s00167-014-3233-9     Document Type: Article
Times cited : (31)

References (37)
  • 1
    • 54449090723 scopus 로고    scopus 로고
    • Rotational position of femoral and tibial components in TKA using the femoral transepicondylar axis
    • PID: 18825470
    • Aglietti P, Sensi L, Cuomo P, Ciardullo A (2008) Rotational position of femoral and tibial components in TKA using the femoral transepicondylar axis. Clin Orthop Relat Res 466:2751–2755
    • (2008) Clin Orthop Relat Res , vol.466 , pp. 2751-2755
    • Aglietti, P.1    Sensi, L.2    Cuomo, P.3    Ciardullo, A.4
  • 4
    • 79960966887 scopus 로고    scopus 로고
    • Internal rotation of the tibial component is frequent in stiff total knee arthroplasty
    • Bedard M, Vince KJ, Redfern J, Collen SR (2011) Internal rotation of the tibial component is frequent in stiff total knee arthroplasty. Clin Orthop Rel Res 469:2346–2355
    • (2011) Clin Orthop Rel Res , vol.469 , pp. 2346-2355
    • Bedard, M.1    Vince, K.J.2    Redfern, J.3    Collen, S.R.4
  • 5
    • 54449092099 scopus 로고    scopus 로고
    • Determining femoral component position using CAS and measured resection
    • PID: 18709429
    • Benjamin J (2008) Determining femoral component position using CAS and measured resection. Clin Orthop Relat Res 466:2745–2750
    • (2008) Clin Orthop Relat Res , vol.466 , pp. 2745-2750
    • Benjamin, J.1
  • 6
    • 78751575863 scopus 로고    scopus 로고
    • Is the anterior tibial tuberosity a reliable rotational landmark for the tibial component in total knee arthroplasty?
    • PID: 20452177
    • Bonnin MP, Saffarini M, Mercier PE, Laurent JR, Carrillon Y (2011) Is the anterior tibial tuberosity a reliable rotational landmark for the tibial component in total knee arthroplasty? J Arthroplasty 26:260–267
    • (2011) J Arthroplasty , vol.26 , pp. 260-267
    • Bonnin, M.P.1    Saffarini, M.2    Mercier, P.E.3    Laurent, J.R.4    Carrillon, Y.5
  • 7
    • 4444262696 scopus 로고    scopus 로고
    • Computer-assisted total knee replacement. A controlled cadaver study using a multiparameter quantitative CT assessment of alignment (The Perth CT protocol)
    • Chauhan SK, Clark GW, Lloyd S, Scott G, Breidahl W, Sikorski JM (2004) Computer-assisted total knee replacement. A controlled cadaver study using a multiparameter quantitative CT assessment of alignment (The Perth CT protocol). J Bone Joint Surg 86-B:818–823
    • (2004) J Bone Joint Surg , vol.86-B , pp. 818-823
    • Chauhan, S.K.1    Clark, G.W.2    Lloyd, S.3    Scott, G.4    Breidahl, W.5    Sikorski, J.M.6
  • 8
    • 81155135118 scopus 로고    scopus 로고
    • Imageless navigation system does not improve component rotational alignment in total knee arthroplasty
    • PID: 21176919
    • Cheng T, Zhang G, Zhang X (2011) Imageless navigation system does not improve component rotational alignment in total knee arthroplasty. J Surg Res 171:590–600
    • (2011) J Surg Res , vol.171 , pp. 590-600
    • Cheng, T.1    Zhang, G.2    Zhang, X.3
  • 9
    • 84862703156 scopus 로고    scopus 로고
    • Does computer-assisted surgery improve postoperative leg alignment and implant positioning following total knee arthroplasty? A meta-analysis of randomized controlled trials?
    • PID: 21732057
    • Cheng T, Zhao S, Peng X, Zhang X (2012) Does computer-assisted surgery improve postoperative leg alignment and implant positioning following total knee arthroplasty? A meta-analysis of randomized controlled trials? Knee Surg Sports Traumatol Arthrosc 20:1307–1322
    • (2012) Knee Surg Sports Traumatol Arthrosc , vol.20 , pp. 1307-1322
    • Cheng, T.1    Zhao, S.2    Peng, X.3    Zhang, X.4
  • 10
    • 53649104513 scopus 로고    scopus 로고
    • The anatomical tibial axis. Reliable rotational orientation in knee replacement
    • Cobb JP, Dixon H, Dandachli W, Iranpour F (2008) The anatomical tibial axis. Reliable rotational orientation in knee replacement. J Bone Joint Surg 90B:1032–1038
    • (2008) J Bone Joint Surg , vol.90B , pp. 1032-1038
    • Cobb, J.P.1    Dixon, H.2    Dandachli, W.3    Iranpour, F.4
  • 11
    • 77953912775 scopus 로고    scopus 로고
    • The association between component malalignment and post-operative pain following navigation-assisted total knee arthroplasty: results of a cohort/nested case-control study
    • PID: 19946667
    • Czurda T, Fennema P, Baumgartner M, Ritschl P (2010) The association between component malalignment and post-operative pain following navigation-assisted total knee arthroplasty: results of a cohort/nested case-control study. Knee Surg Sports Traumatol Arthrosc 18:863–869
    • (2010) Knee Surg Sports Traumatol Arthrosc , vol.18 , pp. 863-869
    • Czurda, T.1    Fennema, P.2    Baumgartner, M.3    Ritschl, P.4
  • 12
    • 77953292038 scopus 로고    scopus 로고
    • Computer assistance increases precision of component placement in total knee arthroplasty with articular deformity
    • PID: 19937166
    • Hernandez-Vaquero D, Suarez-Vazquez A, Sandoval-Garcia MA, Noriega-Fernandez A (2010) Computer assistance increases precision of component placement in total knee arthroplasty with articular deformity. Clin Orthop Relat Res 468:1237–1241
    • (2010) Clin Orthop Relat Res , vol.468 , pp. 1237-1241
    • Hernandez-Vaquero, D.1    Suarez-Vazquez, A.2    Sandoval-Garcia, M.A.3    Noriega-Fernandez, A.4
  • 13
    • 82655172409 scopus 로고    scopus 로고
    • Can computer assistance improve the clinical and functional scores in total knee arthroplasty?
    • PID: 21874390
    • Hernandez-Vaquero D, Suarez-Vazquez A, Iglesias-Fernandez S (2011) Can computer assistance improve the clinical and functional scores in total knee arthroplasty? Clin Orthop Relat Res 469:3436–3442
    • (2011) Clin Orthop Relat Res , vol.469 , pp. 3436-3442
    • Hernandez-Vaquero, D.1    Suarez-Vazquez, A.2    Iglesias-Fernandez, S.3
  • 14
    • 80755132254 scopus 로고    scopus 로고
    • Randomized trial of computer-assisted knee arthroplasty: impact on clinical and radiographic outcomes
    • PID: 21592721
    • Hiscox CM, Bohm ER, Turgeon TR, Hedden DR, Burnell CD (2011) Randomized trial of computer-assisted knee arthroplasty: impact on clinical and radiographic outcomes. J Arthroplasty 26:1259–1264
    • (2011) J Arthroplasty , vol.26 , pp. 1259-1264
    • Hiscox, C.M.1    Bohm, E.R.2    Turgeon, T.R.3    Hedden, D.R.4    Burnell, C.D.5
  • 15
    • 84884534106 scopus 로고    scopus 로고
    • Accurate alignment and high function after kinematically aligned TKA performed with generic instruments
    • PID: 23948721
    • Howell SM, Papadopoulos S, Kuznik KT, Hull ML (2013) Accurate alignment and high function after kinematically aligned TKA performed with generic instruments. Knee Surg Sports Traumatol Arthrosc 21:2271–2280
    • (2013) Knee Surg Sports Traumatol Arthrosc , vol.21 , pp. 2271-2280
    • Howell, S.M.1    Papadopoulos, S.2    Kuznik, K.T.3    Hull, M.L.4
  • 16
    • 84876683837 scopus 로고    scopus 로고
    • Is There a gold standard for TKA tibial component rotational alignment?
    • PID: 23392991
    • Hutter EE, Granger JF, Beal MD, Siston RA (2013) Is There a gold standard for TKA tibial component rotational alignment? Clin Orthop Relat Res 471:1646–1653
    • (2013) Clin Orthop Relat Res , vol.471 , pp. 1646-1653
    • Hutter, E.E.1    Granger, J.F.2    Beal, M.D.3    Siston, R.A.4
  • 17
    • 33846871522 scopus 로고    scopus 로고
    • Determining the rotational alignment of the tibial component at total knee replacement. A comparison of two techniques
    • Ikeuchi M, Yamanaka N, Okanoue Y, Ueta E, Tani T (2007) Determining the rotational alignment of the tibial component at total knee replacement. A comparison of two techniques. J Bone Joint Surg Br 89-B:45–49
    • (2007) J Bone Joint Surg Br , vol.89-B , pp. 45-49
    • Ikeuchi, M.1    Yamanaka, N.2    Okanoue, Y.3    Ueta, E.4    Tani, T.5
  • 18
    • 0042422294 scopus 로고    scopus 로고
    • Anatomic rotational relationships of the proximal tibia, distal femur, and patella. Implications for rotational alignment in total knee arthroplasty
    • PID: 12934219
    • Incavo SJ, Coughlin KM, Pappas Ch, Beynnon BD (2003) Anatomic rotational relationships of the proximal tibia, distal femur, and patella. Implications for rotational alignment in total knee arthroplasty. J Arthroplasty 18:643–648
    • (2003) J Arthroplasty , vol.18 , pp. 643-648
    • Incavo, S.J.1    Coughlin, K.M.2    Pappas, C.3    Beynnon, B.D.4
  • 19
    • 0033822907 scopus 로고    scopus 로고
    • The accuracy of computed tomography for determining femoral and tibial total knee arthroplasty component rotation
    • COI: 1:STN:280:DC%2BD3cvmsFGhtw%3D%3D, PID: 11021452
    • Jazrawi LM, Birdzell L, Kummer FJ, Di Cesare PE (2000) The accuracy of computed tomography for determining femoral and tibial total knee arthroplasty component rotation. J Arthroplasty 15:761–766
    • (2000) J Arthroplasty , vol.15 , pp. 761-766
    • Jazrawi, L.M.1    Birdzell, L.2    Kummer, F.J.3    Di Cesare, P.E.4
  • 20
    • 1342305509 scopus 로고    scopus 로고
    • Low reproducibility of the intra–operative measurement of the transepicondylar axis during total knee replacement
    • PID: 15022812
    • Jenny JY, Boeri C (2004) Low reproducibility of the intra–operative measurement of the transepicondylar axis during total knee replacement. Acta Orthop Scand 75:74–77
    • (2004) Acta Orthop Scand , vol.75 , pp. 74-77
    • Jenny, J.Y.1    Boeri, C.2
  • 22
    • 84894584951 scopus 로고    scopus 로고
    • The relationship between the survival of total knee arthroplasty and postoperative coronal, sagittal and rotational alignment of knee prosthesis
    • PID: 24173677
    • Kim H-O, Park J-W, Kim J-S, Park S-D (2014) The relationship between the survival of total knee arthroplasty and postoperative coronal, sagittal and rotational alignment of knee prosthesis. Int Orthop 38:379–385
    • (2014) Int Orthop , vol.38 , pp. 379-385
    • Kim, H.-O.1    Park, J.-W.2    Kim, J.-S.3    Park, S.-D.4
  • 23
    • 84884530756 scopus 로고    scopus 로고
    • Less femoral lift-off and better femoral alignment in TKA using computer-assisted surgery
    • PID: 23052122
    • Kim SW, Lee H-J, Jung H-J, Lee J-S, Kim KS (2013) Less femoral lift-off and better femoral alignment in TKA using computer-assisted surgery. Knee Surg Sports Traumatol Arthrosc 21:2255–2262
    • (2013) Knee Surg Sports Traumatol Arthrosc , vol.21 , pp. 2255-2262
    • Kim, S.W.1    Lee, H.-J.2    Jung, H.-J.3    Lee, J.-S.4    Kim, K.S.5
  • 24
    • 84884531175 scopus 로고    scopus 로고
    • Radiographic accuracy in TKA with a CT-based patient-specific cutting block technique
    • COI: 1:STN:280:DC%2BC3sfpsVemsQ%3D%3D, PID: 23942882
    • Koch PP, Müller D, Pisan M, Fucentese SF (2013) Radiographic accuracy in TKA with a CT-based patient-specific cutting block technique. Knee Surg Sports Traumatol Arthrosc 21:2200–2205
    • (2013) Knee Surg Sports Traumatol Arthrosc , vol.21 , pp. 2200-2205
    • Koch, P.P.1    Müller, D.2    Pisan, M.3    Fucentese, S.F.4
  • 25
    • 84870300920 scopus 로고    scopus 로고
    • CT measurements prior to computer-assisted total knee arthroplasty do not improve rotational placement of the femoral component
    • de Ladoucette A (2012) CT measurements prior to computer-assisted total knee arthroplasty do not improve rotational placement of the femoral component. Knee Surg Sports Traumatol Arthrosc 20:2471–2475
    • (2012) Knee Surg Sports Traumatol Arthrosc , vol.20 , pp. 2471-2475
    • de Ladoucette, A.1
  • 26
    • 53249142255 scopus 로고    scopus 로고
    • Rotational alignment of femoral component with computed-assisted surgery (CAS) during total knee arthroplasty
    • COI: 1:STN:280:DC%2BD1cnnsVagtw%3D%3D, PID: 18929753
    • Michaut M, Beaufils P, Galaud B, Abadie P, Boisrenoult P, Fallet L (2008) Rotational alignment of femoral component with computed-assisted surgery (CAS) during total knee arthroplasty. Rev Chir Orthop Reparatrice Appar Mot 94:580–584
    • (2008) Rev Chir Orthop Reparatrice Appar Mot , vol.94 , pp. 580-584
    • Michaut, M.1    Beaufils, P.2    Galaud, B.3    Abadie, P.4    Boisrenoult, P.5    Fallet, L.6
  • 27
    • 84857282759 scopus 로고    scopus 로고
    • Comparison of robot-assisted and conventional total knee arthroplasty: a controlled cadaver study using multiparameter quantitative three-dimensional CT assessment of alignment
    • PID: 22348661
    • Moon YW, Ha CW, Do KH, Kim CY, Han JH, Na SE, Lee CH, Kim JG, Park YS (2012) Comparison of robot-assisted and conventional total knee arthroplasty: a controlled cadaver study using multiparameter quantitative three-dimensional CT assessment of alignment. Comput Aided Surg 17:86–95
    • (2012) Comput Aided Surg , vol.17 , pp. 86-95
    • Moon, Y.W.1    Ha, C.W.2    Do, K.H.3    Kim, C.Y.4    Han, J.H.5    Na, S.E.6    Lee, C.H.7    Kim, J.G.8    Park, Y.S.9
  • 28
    • 77956352984 scopus 로고    scopus 로고
    • Nicoll D, Rowley DI (2010). Internal rotational error of the tibial component is a major cause of pain after total knee replacement. J Bone Joint Surg 92-B:1238–1244
    • (2010) J Bone Joint Surg , vol.92B , pp. 1238-1244
    • Nicoll, D.1    Rowley, D.I.2
  • 30
    • 84892524380 scopus 로고    scopus 로고
    • Femoral and tibial component rotation in total knee arthroplasty
    • Scout RD (2013) Femoral and tibial component rotation in total knee arthroplasty. Methods and consequences. Bone Joint J 95B:140–143
    • (2013) Methods and consequences. Bone Joint J , vol.95B , pp. 140-143
    • Scout, R.D.1
  • 32
    • 53549126640 scopus 로고    scopus 로고
    • Averaging different alignment axes improves femoral rotational alignment in computer-navigated total knee arthroplasty
    • Siston RA, Cromie MJ, Gold GE, Goodman SB, Delp SL, Maloney WJ, Giori NJ (2008) Averaging different alignment axes improves femoral rotational alignment in computer-navigated total knee arthroplasty. J Bone Joint Surg 90A:2098–2104
    • (2008) J Bone Joint Surg , vol.90A , pp. 2098-2104
    • Siston, R.A.1    Cromie, M.J.2    Gold, G.E.3    Goodman, S.B.4    Delp, S.L.5    Maloney, W.J.6    Giori, N.J.7
  • 34
    • 80053071556 scopus 로고    scopus 로고
    • A computed tomography based study on rotational alignment accuracy of the femoral component in total knee arthroplasty using computer-assisted orthopaedic surgery
    • van der Linden-van der Zwaag HM, Bos J, van der Heide HJ, Nelissen RG (2011). A computed tomography based study on rotational alignment accuracy of the femoral component in total knee arthroplasty using computer-assisted orthopaedic surgery. Int Orthop 35:845–850
    • (2011) Int Orthop , vol.35 , pp. 845-850
  • 35
    • 68249091919 scopus 로고    scopus 로고
    • Rotational alignment of the distal femur: a literature review
    • COI: 1:STN:280:DC%2BD1Mrlt12rtg%3D%3D
    • Victor J (2009) Rotational alignment of the distal femur: a literature review. Orthop Traumat Surg Res 95:365–372
    • (2009) Orthop Traumat Surg Res , vol.95 , pp. 365-372
    • Victor, J.1
  • 36
    • 84887541400 scopus 로고    scopus 로고
    • Rotational alignment in total knee arthroplasty
    • Walmsley D, Backstein D (2013) Rotational alignment in total knee arthroplasty. Sem Arthroplasty 24:156–159
    • (2013) Sem Arthroplasty , vol.24 , pp. 156-159
    • Walmsley, D.1    Backstein, D.2
  • 37
    • 36849081392 scopus 로고    scopus 로고
    • Interobserver and intra-observer errors in obtaining visually selected anatomical landmarks during registration process in non–image-based navigation-assisted in total knee arthroplasty
    • COI: 1:STN:280:DC%2BD2sjksVCntg%3D%3D, PID: 18078884
    • Yau WP, Leung A, Liu KG, Yan CH, Wong LLS, Chiu KY (2007) Interobserver and intra-observer errors in obtaining visually selected anatomical landmarks during registration process in non–image-based navigation-assisted in total knee arthroplasty. J Arthroplasty 22:1150–1161
    • (2007) J Arthroplasty , vol.22 , pp. 1150-1161
    • Yau, W.P.1    Leung, A.2    Liu, K.G.3    Yan, C.H.4    Wong, L.L.S.5    Chiu, K.Y.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.