메뉴 건너뛰기




Volumn 32, Issue 12, 2014, Pages 1513-1515

Optic nerve sheath diameter and lumbar puncture opening pressure in nontrauma patients suspected of elevated intracranial pressure

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AREA UNDER THE CURVE; ARTICLE; COHORT ANALYSIS; COMPARATIVE STUDY; COMPUTER ASSISTED TOMOGRAPHY; CONVENIENCE SAMPLE; CROSS-SECTIONAL STUDY; EMERGENCY WARD; FEMALE; HUMAN; INTRACRANIAL HYPERTENSION; INTRACRANIAL PRESSURE; LUMBAR PUNCTURE; MAJOR CLINICAL STUDY; MALE; MANOMETRY; OBSERVATIONAL STUDY; OPTIC NERVE; PPTIC NERVE SHEATH DIAMETER; PROSPECTIVE STUDY; REAL TIME ULTRASOUND SCANNER; RECEIVER OPERATING CHARACTERISTIC; SENSITIVITY AND SPECIFICITY; ULTRASOUND; ECHOGRAPHY; PATHOLOGY; PUNCTURE;

EID: 84911040541     PISSN: 07356757     EISSN: 15328171     Source Type: Journal    
DOI: 10.1016/j.ajem.2014.09.014     Document Type: Article
Times cited : (33)

References (10)
  • 1
    • 0037389555 scopus 로고    scopus 로고
    • Elevated intracranial pressure detected by bedside emergency ultrasonography of the optic nerve sheath
    • M. Blaivas, D. Theodoro, and P.R. Sierzenski Elevated intracranial pressure detected by bedside emergency ultrasonography of the optic nerve sheath Acad Emerg Med 10 2003 376 381
    • (2003) Acad Emerg Med , vol.10 , pp. 376-381
    • Blaivas, M.1    Theodoro, D.2    Sierzenski, P.R.3
  • 2
    • 34748921616 scopus 로고    scopus 로고
    • Ultrasonography of the optic nerve sheath may be useful for detecting raised intracranial pressure after severe brain injury
    • T. Geeraerts, Y. Launey, L. Martin, J. Pottecher, B. Vigue, and J. Duranteau Ultrasonography of the optic nerve sheath may be useful for detecting raised intracranial pressure after severe brain injury Intensive Care Med 33 2007 1704 1711
    • (2007) Intensive Care Med , vol.33 , pp. 1704-1711
    • Geeraerts, T.1    Launey, Y.2    Martin, L.3    Pottecher, J.4    Vigue, B.5    Duranteau, J.6
  • 3
    • 84856260997 scopus 로고    scopus 로고
    • Optic nerve ultrasound for the detection of raised intracranial pressure
    • V. Rajajee, M. Vanaman, J.J. Fletcher, and T.L. Jacobs Optic nerve ultrasound for the detection of raised intracranial pressure Neurocrit Care 15 2011 506 515
    • (2011) Neurocrit Care , vol.15 , pp. 506-515
    • Rajajee, V.1    Vanaman, M.2    Fletcher, J.J.3    Jacobs, T.L.4
  • 4
    • 80052796844 scopus 로고    scopus 로고
    • Sonographic optic nerve sheath diameter as an estimate of intracranial pressure in adult trauma
    • A. Strumwasser, R.O. Kwan, L. Yeung, E. Miraflor, A. Ereso, and F. Castro-Moure Sonographic optic nerve sheath diameter as an estimate of intracranial pressure in adult trauma J Surg Res 170 2011 265 271
    • (2011) J Surg Res , vol.170 , pp. 265-271
    • Strumwasser, A.1    Kwan, R.O.2    Yeung, L.3    Miraflor, E.4    Ereso, A.5    Castro-Moure, F.6
  • 5
    • 33947254493 scopus 로고    scopus 로고
    • Emergency department sonographic measurement of optic nerve sheath diameter to detect findings of increased intracranial pressure in adult head injury patients
    • V.S. Tayal, M. Neulander, H.J. Norton, T. Foster, T. Saunders, and M. Blaivas Emergency department sonographic measurement of optic nerve sheath diameter to detect findings of increased intracranial pressure in adult head injury patients Ann Emerg Med 49 2007 508 514
    • (2007) Ann Emerg Med , vol.49 , pp. 508-514
    • Tayal, V.S.1    Neulander, M.2    Norton, H.J.3    Foster, T.4    Saunders, T.5    Blaivas, M.6
  • 6
    • 85027948724 scopus 로고    scopus 로고
    • Ultrasonography of optic nerve sheath diameter for detection of raised intracranial pressure: A systematic review and meta-analysis
    • J. Dubourg, E. Javouhey, T. Geeraerts, M. Messerer, and B. Kassai Ultrasonography of optic nerve sheath diameter for detection of raised intracranial pressure: a systematic review and meta-analysis Intensive Care Med 37 2011 1059 1068
    • (2011) Intensive Care Med , vol.37 , pp. 1059-1068
    • Dubourg, J.1    Javouhey, E.2    Geeraerts, T.3    Messerer, M.4    Kassai, B.5
  • 7
    • 84857678143 scopus 로고    scopus 로고
    • Sonographic assessment of the optic nerve sheath in idiopathic intracranial hypertension
    • J. Bauerle, and M. Nedelmann Sonographic assessment of the optic nerve sheath in idiopathic intracranial hypertension J Neurol 258 2011 2014 2019
    • (2011) J Neurol , vol.258 , pp. 2014-2019
    • Bauerle, J.1    Nedelmann, M.2
  • 9
    • 52049119909 scopus 로고    scopus 로고
    • Clinical policy: Critical issues in the evaluation and management of adult patients presenting to the emergency department with acute headache
    • College Of Emergency Physicians A.
    • J.A. Edlow, P.D. Panagos, S.A. Godwin, T.L. Thomas, W.W. Decker, and American College of Emergency Physicians Clinical policy: critical issues in the evaluation and management of adult patients presenting to the emergency department with acute headache Ann Emerg Med 52 2008 407 436
    • (2008) Ann Emerg Med , vol.52 , pp. 407-436
    • Edlow, J.A.1    Panagos, P.D.2    Godwin, S.A.3    Thomas, T.L.4    Decker, W.W.5
  • 10
    • 84888331608 scopus 로고    scopus 로고
    • Reproducibility and accuracy of optic nerve sheath diameter assessment using ultrasound compared to magnetic resonance imaging
    • J. Bauerle, F. Schuchardt, L. Schroeder, K. Egger, M. Weigel, and A. Harloff Reproducibility and accuracy of optic nerve sheath diameter assessment using ultrasound compared to magnetic resonance imaging BMC Neurol 13 2013
    • (2013) BMC Neurol , vol.13
    • Bauerle, J.1    Schuchardt, F.2    Schroeder, L.3    Egger, K.4    Weigel, M.5    Harloff, A.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.