메뉴 건너뛰기




Volumn 13, Issue , 2013, Pages

Reproducibility and accuracy of optic nerve sheath diameter assessment using ultrasound compared to magnetic resonance imaging

Author keywords

HASTE; MRI; Optic nerve sheath diameter; Transbulbar sonography; TSE

Indexed keywords

ADULT; ARTICLE; ECHOGRAPHY; FEMALE; HUMAN; INTERMETHOD COMPARISON; MALE; MEASUREMENT ACCURACY; NERVOUS SYSTEM PARAMETERS; NORMAL HUMAN; NUCLEAR MAGNETIC RESONANCE IMAGING; OPTIC NERVE; OPTIC NERVE SHEATH DIAMETER; PROSPECTIVE STUDY; QUANTITATIVE ANALYSIS; RELIABILITY; REPRODUCIBILITY; TRANSBULBAR SONOGRAPHY; ULTRASOUND TRANSDUCER; WHOLE BODY SCANNER;

EID: 84888331608     PISSN: None     EISSN: 14712377     Source Type: Journal    
DOI: 10.1186/1471-2377-13-187     Document Type: Article
Times cited : (158)

References (16)
  • 1
    • 84857678143 scopus 로고    scopus 로고
    • Sonographic assessment of the optic nerve sheath in idiopathic intracranial hypertension
    • Bäuerle J, Nedelmann M. Sonographic assessment of the optic nerve sheath in idiopathic intracranial hypertension. J Neurol 2001, 258:2014-2019.
    • (2001) J Neurol , vol.258 , pp. 2014-2019
    • Bäuerle, J.1    Nedelmann, M.2
  • 2
    • 54449094864 scopus 로고    scopus 로고
    • Non-invasive assessment of intracranial pressure using ocular sonography in neurocritical care patients
    • 10.1007/s00134-008-1149-x, 18509619
    • Geeraerts T, Merceron S, Benhamou D, Vigué B, Duranteau J. Non-invasive assessment of intracranial pressure using ocular sonography in neurocritical care patients. Intensive Care Med 2008, 34:2062-2067. 10.1007/s00134-008-1149-x, 18509619.
    • (2008) Intensive Care Med , vol.34 , pp. 2062-2067
    • Geeraerts, T.1    Merceron, S.2    Benhamou, D.3    Vigué, B.4    Duranteau, J.5
  • 5
    • 80052619842 scopus 로고    scopus 로고
    • Increase in optic nerve sheath diameter induced by epidural blood patch: a preliminary report
    • 10.1093/bja/aer186, 21693468
    • Dubost C, Le Gouez A, Zetlaoui PJ, Benhamou D, Mercier FJ, Geeraerts T. Increase in optic nerve sheath diameter induced by epidural blood patch: a preliminary report. Br J Anaesth 2011, 107:627-630. 10.1093/bja/aer186, 21693468.
    • (2011) Br J Anaesth , vol.107 , pp. 627-630
    • Dubost, C.1    Le Gouez, A.2    Zetlaoui, P.J.3    Benhamou, D.4    Mercier, F.J.5    Geeraerts, T.6
  • 6
    • 33846569944 scopus 로고    scopus 로고
    • Cerebrospinal fluid dynamics between the intracranial and the subarachnoid space of the optic nerve. Is it always bidirectional?
    • 10.1093/brain/awl324, 17114796
    • Killer HE, Jaggi GP, Flammer J, Miller NR, Huber AR, Mironov A. Cerebrospinal fluid dynamics between the intracranial and the subarachnoid space of the optic nerve. Is it always bidirectional?. Brain 2007, 130:514-520. 10.1093/brain/awl324, 17114796.
    • (2007) Brain , vol.130 , pp. 514-520
    • Killer, H.E.1    Jaggi, G.P.2    Flammer, J.3    Miller, N.R.4    Huber, A.R.5    Mironov, A.6
  • 7
    • 0030999303 scopus 로고    scopus 로고
    • Validation of the optic nerve sheath response to changing cerebrospinal fluid pressure: ultrasound findings during intrathecal infusion tests
    • 10.3171/jns.1997.87.1.0034, 9202262
    • Hansen HC, Helmke K. Validation of the optic nerve sheath response to changing cerebrospinal fluid pressure: ultrasound findings during intrathecal infusion tests. J Neurosurg 1997, 87:34-40. 10.3171/jns.1997.87.1.0034, 9202262.
    • (1997) J Neurosurg , vol.87 , pp. 34-40
    • Hansen, H.C.1    Helmke, K.2
  • 8
    • 0036804714 scopus 로고    scopus 로고
    • Observer variation in the sonographic measurement of optic nerve sheath diameter in normal adults
    • 10.1016/S0929-8266(02)00036-8, 12423741
    • Ballantyne SA, O'Neill G, Hamilton R, Hollman AS. Observer variation in the sonographic measurement of optic nerve sheath diameter in normal adults. Eur J Ultrasound 2002, 15:145-149. 10.1016/S0929-8266(02)00036-8, 12423741.
    • (2002) Eur J Ultrasound , vol.15 , pp. 145-149
    • Ballantyne, S.A.1    O'Neill, G.2    Hamilton, R.3    Hollman, A.S.4
  • 9
    • 84855928920 scopus 로고    scopus 로고
    • Intra- and interobsever reliability of sonographic assessment of the optic nerve sheath diameter in healthy adults
    • 10.1111/j.1552-6569.2010.00546.x, 21121998
    • Bäuerle J, Lochner P, Kaps M, Nedelmann M. Intra- and interobsever reliability of sonographic assessment of the optic nerve sheath diameter in healthy adults. J Neuroimaging 2012, 22:42-45. 10.1111/j.1552-6569.2010.00546.x, 21121998.
    • (2012) J Neuroimaging , vol.22 , pp. 42-45
    • Bäuerle, J.1    Lochner, P.2    Kaps, M.3    Nedelmann, M.4
  • 10
    • 34250182757 scopus 로고    scopus 로고
    • Morphometry of the retrobulbar human optic nerve: comparison between conventional sonography and ultrafast magnetic resonance sequences
    • 10.1167/iovs.06-1075, 17460241
    • Lagrèze WA, Lazzaro A, Weigel M, Hansen HC, Hennig J, Bley TA. Morphometry of the retrobulbar human optic nerve: comparison between conventional sonography and ultrafast magnetic resonance sequences. Invest Ophthalmol Vis Sci 2007, 48:1913-1917. 10.1167/iovs.06-1075, 17460241.
    • (2007) Invest Ophthalmol Vis Sci , vol.48 , pp. 1913-1917
    • Lagrèze, W.A.1    Lazzaro, A.2    Weigel, M.3    Hansen, H.C.4    Hennig, J.5    Bley, T.A.6
  • 11
    • 85085490359 scopus 로고    scopus 로고
    • Measurement of the Optic Nerve Sheath Diameter in Children: Comparison Between Transbulbar Sonography and Magnetic Resonance Imaging
    • Steinborn M, Fiegler J, Ruedisser K, Hapfelmeier A, Denne C, Macdonald E, Hahn H. Measurement of the Optic Nerve Sheath Diameter in Children: Comparison Between Transbulbar Sonography and Magnetic Resonance Imaging. Ultraschall in Med 2012, 33:569-573.
    • (2012) Ultraschall in Med , vol.33 , pp. 569-573
    • Steinborn, M.1    Fiegler, J.2    Ruedisser, K.3    Hapfelmeier, A.4    Denne, C.5    Macdonald, E.6    Hahn, H.7
  • 12
    • 0029770461 scopus 로고    scopus 로고
    • Fundamentals of transorbital sonographic evaluation of optic nerve sheath expansion under intracranial hypertension I. Experimental study
    • 10.1007/BF01383383, 8805599
    • Helmke K, Hansen HC. Fundamentals of transorbital sonographic evaluation of optic nerve sheath expansion under intracranial hypertension I. Experimental study. Pediatr Radiol 1996, 26:701-705. 10.1007/BF01383383, 8805599.
    • (1996) Pediatr Radiol , vol.26 , pp. 701-705
    • Helmke, K.1    Hansen, H.C.2
  • 13
    • 0029786097 scopus 로고    scopus 로고
    • Fundamentals of transorbital sonographic evaluation of optic nerve sheath expansion under intracranial hypertension II. Patient study
    • 10.1007/BF01383384, 8805600
    • Helmke K, Hansen HC. Fundamentals of transorbital sonographic evaluation of optic nerve sheath expansion under intracranial hypertension II. Patient study. Pediatr Radiol 1996, 26:706-710. 10.1007/BF01383384, 8805600.
    • (1996) Pediatr Radiol , vol.26 , pp. 706-710
    • Helmke, K.1    Hansen, H.C.2
  • 14
    • 33646339426 scopus 로고    scopus 로고
    • Fast and quantitative high-resolution magnetic resonance imaging of the optic nerve at 3.0 tesla
    • 10.1097/01.rli.0000195820.98062.c5, 16428977
    • Weigel M, Lagrèze WA, Lazzaro A, Hennig J, Bley TA. Fast and quantitative high-resolution magnetic resonance imaging of the optic nerve at 3.0 tesla. Invest Radiol 2006, 41:83-86. 10.1097/01.rli.0000195820.98062.c5, 16428977.
    • (2006) Invest Radiol , vol.41 , pp. 83-86
    • Weigel, M.1    Lagrèze, W.A.2    Lazzaro, A.3    Hennig, J.4    Bley, T.A.5
  • 15
    • 70349257365 scopus 로고    scopus 로고
    • Retrobulbar optic nerve diameter measured by high-speed magnetic resonance imaging as a biomarker for axonal loss in glaucomatous optic atrophy
    • 10.1167/iovs.08-2683, 19407026
    • Lagrèze WA, Gaggl M, Weigel M, Schulte-Mönting J, Bühler A, Bach M, Munk RD, Bley TA. Retrobulbar optic nerve diameter measured by high-speed magnetic resonance imaging as a biomarker for axonal loss in glaucomatous optic atrophy. Invest Ophthalmol Vis Sci 2009, 50:4223-4228. 10.1167/iovs.08-2683, 19407026.
    • (2009) Invest Ophthalmol Vis Sci , vol.50 , pp. 4223-4228
    • Lagrèze, W.A.1    Gaggl, M.2    Weigel, M.3    Schulte-Mönting, J.4    Bühler, A.5    Bach, M.6    Munk, R.D.7    Bley, T.A.8
  • 16
    • 83655164976 scopus 로고    scopus 로고
    • High Resolution Ultrasound and Magnetic Resonance Imaging of the Optic Nerve and the Optic Nerve Sheath: Anatomic Correlation and Clinical Importance
    • Steinborn M, Fiegler J, Kraus V, Denne C, Hapfelmeier A, Wurzinger L, Hahn H. High Resolution Ultrasound and Magnetic Resonance Imaging of the Optic Nerve and the Optic Nerve Sheath: Anatomic Correlation and Clinical Importance. Ultraschall in Med 2011, 32:608-613.
    • (2011) Ultraschall in Med , vol.32 , pp. 608-613
    • Steinborn, M.1    Fiegler, J.2    Kraus, V.3    Denne, C.4    Hapfelmeier, A.5    Wurzinger, L.6    Hahn, H.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.