-
2
-
-
33846269659
-
Mannheim carotid intima-media thickness consensus (2004-2006)
-
P.-J. Touboul, M. Hennerici, S. Meairs, H. Adams, P. Amarenco, N. Bornstein, L. Csiba, M. Desvarieux, S. Ebrahim, and M. Fatar Mannheim carotid intima-media thickness consensus (2004-2006) Cerebrovasc. Dis. 23 2007 75 80
-
(2007)
Cerebrovasc. Dis.
, vol.23
, pp. 75-80
-
-
Touboul, P.-J.1
Hennerici, M.2
Meairs, S.3
Adams, H.4
Amarenco, P.5
Bornstein, N.6
Csiba, L.7
Desvarieux, M.8
Ebrahim, S.9
Fatar, M.10
-
3
-
-
0027446488
-
Isolated systolic hypertension and vessel wall thickness of the carotid artery. the Rotterdam Elderly Study
-
M.L. Bots, A. Hofman, A.M. de Bruyn, P.T. de Jong, and D.E. Grobbee Isolated systolic hypertension and vessel wall thickness of the carotid artery. The Rotterdam Elderly Study Arterioscler. Thrombos. Vasc. Biol. 13 1993 64 69
-
(1993)
Arterioscler. Thrombos. Vasc. Biol.
, vol.13
, pp. 64-69
-
-
Bots, M.L.1
Hofman, A.2
De Bruyn, A.M.3
De Jong, P.T.4
Grobbee, D.E.5
-
4
-
-
33846609195
-
Prediction of clinical cardiovascular events with carotid intima-media thickness: A systematic review and meta-analysis
-
M. Lorenz, H. Markus, M. Bots, M. Rosvall, and M. Sitzer Prediction of clinical cardiovascular events with carotid intima-media thickness: a systematic review and meta-analysis Circ.: J. Am. Heart Assoc. 115 2007 459 467
-
(2007)
Circ.: J. Am. Heart Assoc.
, vol.115
, pp. 459-467
-
-
Lorenz, M.1
Markus, H.2
Bots, M.3
Rosvall, M.4
Sitzer, M.5
-
5
-
-
84884628631
-
Atherosclerosis: The evolving role of vascular image analysis
-
K.S. Nikita Atherosclerosis: the evolving role of vascular image analysis Comp. Med. Imaging Graph. 2012
-
(2012)
Comp. Med. Imaging Graph.
-
-
Nikita, K.S.1
-
6
-
-
4244087040
-
Ultrasound B-mode imaging in observational studies of atherosclerotic progression
-
J. Salonen, and R. Salonen Ultrasound B-mode imaging in observational studies of atherosclerotic progression Circulation 87 Suppl. II 1993 56 65
-
(1993)
Circulation
, vol.87
, Issue.SUPPLEMENT II
, pp. 56-65
-
-
Salonen, J.1
Salonen, R.2
-
7
-
-
56749163347
-
Reproducibility of sonographic measurements of carotid intima-media thickness
-
F. Velázquez, J.D. Berná, J.L. Abellán, L. Serrano, A. Escribano, and M. Canteras Reproducibility of sonographic measurements of carotid intima-media thickness Acta Radiol. 49 2008 1162 1166
-
(2008)
Acta Radiol.
, vol.49
, pp. 1162-1166
-
-
Velázquez, F.1
Berná, J.D.2
Abellán, J.L.3
Serrano, L.4
Escribano, A.5
Canteras, M.6
-
8
-
-
0034421371
-
Greedy algorithm for error correction in automatically produced boundaries from low contrast ventriculograms
-
J.S. Suri, R.M. Haralick, and F.H. Sheehan Greedy algorithm for error correction in automatically produced boundaries from low contrast ventriculograms Pattern Anal. Appl. 3 2000 39 60
-
(2000)
Pattern Anal. Appl.
, vol.3
, pp. 39-60
-
-
Suri, J.S.1
Haralick, R.M.2
Sheehan, F.H.3
-
9
-
-
0020573591
-
Variability in the measurement of regional left ventricular wall motion from contrast angiograms
-
F.H. Sheehan, D.K. Stewart, H.T. Dodge, S. Mitten, E.L. Bolson, and B.G. Brown Variability in the measurement of regional left ventricular wall motion from contrast angiograms. Circulation 68 1983 550 559
-
(1983)
Circulation
, vol.68
, pp. 550-559
-
-
Sheehan, F.H.1
Stewart, D.K.2
Dodge, H.T.3
Mitten, S.4
Bolson, E.L.5
Brown, B.G.6
-
11
-
-
0015285440
-
Use of the hough transformation to detect lines and curves in pictures
-
R.O. Duda, and P.E. Hart Use of the hough transformation to detect lines and curves in pictures Commun. ACM 15 1972 11 15
-
(1972)
Commun. ACM
, vol.15
, pp. 11-15
-
-
Duda, R.O.1
Hart, P.E.2
-
15
-
-
0036034807
-
Splines: A perfect fit for medical imaging
-
M. Unser Splines: a perfect fit for medical imaging Progr. Biomed. Opt. Imaging 2002 225 236
-
(2002)
Progr. Biomed. Opt. Imaging
, pp. 225-236
-
-
Unser, M.1
-
16
-
-
0027576716
-
Morphological grayscale reconstruction in image analysis: Applications and efficient algorithms
-
L. Vincent Morphological grayscale reconstruction in image analysis: applications and efficient algorithms IEEE Trans. Image Process. 2 1993 176 201
-
(1993)
IEEE Trans. Image Process.
, vol.2
, pp. 176-201
-
-
Vincent, L.1
-
17
-
-
0032884749
-
Measuring agreement in method comparison studies
-
J.M. Bland, and D.G. Altman Measuring agreement in method comparison studies Stat. Methods Med. Res. 8 1999 135 160
-
(1999)
Stat. Methods Med. Res.
, vol.8
, pp. 135-160
-
-
Bland, J.M.1
Altman, D.G.2
-
18
-
-
0000815211
-
A dynamic programming procedure for automated ultrasonic measurement of the carotid artery
-
T. Gustavsson, Q. Liang, I. Wendelhag, and J. Wikstrand A dynamic programming procedure for automated ultrasonic measurement of the carotid artery Comp. Cardiol. 1994 297 300
-
(1994)
Comp. Cardiol.
, pp. 297-300
-
-
Gustavsson, T.1
Liang, Q.2
Wendelhag, I.3
Wikstrand, J.4
-
19
-
-
0030710511
-
A new automated computerized analyzing system simplifies readings and reduces the variability in ultrasound measurement of intima-media thickness
-
I. Wendelhag, Q. Liang, T. Gustavsson, and J. Wikstrand A new automated computerized analyzing system simplifies readings and reduces the variability in ultrasound measurement of intima-media thickness Stroke 28 1997 2195 2200
-
(1997)
Stroke
, vol.28
, pp. 2195-2200
-
-
Wendelhag, I.1
Liang, Q.2
Gustavsson, T.3
Wikstrand, J.4
-
20
-
-
0033624995
-
A multiscale dynamic programming procedure for boundary detection in ultrasonic artery images
-
Q. Liang, I. Wendelhag, J. Wikstrand, and T. Gustavsson A multiscale dynamic programming procedure for boundary detection in ultrasonic artery images IEEE Trans. Med. Imag 19 2000 127 142
-
(2000)
IEEE Trans. Med. Imag
, vol.19
, pp. 127-142
-
-
Liang, Q.1
Wendelhag, I.2
Wikstrand, J.3
Gustavsson, T.4
-
21
-
-
47849127426
-
Automatic measurement of the intima-media thickness with active contour based image segmentation
-
M. Ceccarelli, N. De Luca, and A. Morganella Automatic measurement of the intima-media thickness with active contour based image segmentation IEEE International Workshop on Medical Measurement and Applications, 2007, MEMEA'07 2007 1 5
-
(2007)
IEEE International Workshop on Medical Measurement and Applications, 2007, MEMEA'07
, pp. 1-5
-
-
Ceccarelli, M.1
De Luca, N.2
Morganella, A.3
-
22
-
-
56549127393
-
Detections of arterial wall in sonographic artery images using dual dynamic programming
-
D.-C. Cheng, and X. Jiang Detections of arterial wall in sonographic artery images using dual dynamic programming, IEEE Trans. Inform. Technol. Biomed. 12 2008 792 799
-
(2008)
IEEE Trans. Inform. Technol. Biomed.
, vol.12
, pp. 792-799
-
-
Cheng, D.-C.1
Jiang, X.2
-
24
-
-
74749094600
-
Segmentation of the carotid intima-media region in B-mode ultrasound images
-
R. Rocha, A. Campilho, J. Silva, E. Azevedo, and R. Santos Segmentation of the carotid intima-media region in B-mode ultrasound images Image Vis. Comput. 28 2010 614 625
-
(2010)
Image Vis. Comput.
, vol.28
, pp. 614-625
-
-
Rocha, R.1
Campilho, A.2
Silva, J.3
Azevedo, E.4
Santos, R.5
-
25
-
-
59449093925
-
Segmentation in ultrasonic B-mode images of healthy carotid arteries using mixtures of Nakagami distributions and stochastic optimization
-
F. Destrempes, J. Meunier, M.-F. Giroux, G. Soulez, and G. Cloutier Segmentation in ultrasonic B-mode images of healthy carotid arteries using mixtures of Nakagami distributions and stochastic optimization IEEE Trans. Med. Imaging 28 2009 215 229
-
(2009)
IEEE Trans. Med. Imaging
, vol.28
, pp. 215-229
-
-
Destrempes, F.1
Meunier, J.2
Giroux, M.-F.3
Soulez, G.4
Cloutier, G.5
-
26
-
-
36849025927
-
Using the hough transform to segment ultrasound images of longitudinal and transverse sections of the carotid artery
-
S. Golemati, J. Stoitsis, E.G. Sifakis, T. Balkizas, and K.S. Nikita Using the hough transform to segment ultrasound images of longitudinal and transverse sections of the carotid artery Ultrasound Med. Biol. 33 2007 1918 1932
-
(2007)
Ultrasound Med. Biol.
, vol.33
, pp. 1918-1932
-
-
Golemati, S.1
Stoitsis, J.2
Sifakis, E.G.3
Balkizas, T.4
Nikita, K.S.5
-
27
-
-
84858072893
-
Ultrasound intima-media segmentation using hough transform and dual snake model
-
X. Xu, Y. Zhou, X. Cheng, E. Song, and G. Li Ultrasound intima-media segmentation using hough transform and dual snake model Comp. Med. Imaging Graph. 36 2012 248 258
-
(2012)
Comp. Med. Imaging Graph.
, vol.36
, pp. 248-258
-
-
Xu, X.1
Zhou, Y.2
Cheng, X.3
Song, E.4
Li, G.5
-
28
-
-
78650679026
-
Segmentation of ultrasound images of the carotid using ransac and cubic splines
-
R. Rocha, A. Campilho, J. Silva, E. Azevedo, and R. Santos Segmentation of ultrasound images of the carotid using ransac and cubic splines Comp. Methods Progr. Biomed. 101 2011 94 106
-
(2011)
Comp. Methods Progr. Biomed.
, vol.101
, pp. 94-106
-
-
Rocha, R.1
Campilho, A.2
Silva, J.3
Azevedo, E.4
Santos, R.5
-
29
-
-
77957890201
-
Review: A state of the art review on intima-media thickness (IMT) measurement and wall segmentation techniques for carotid ultrasound
-
F. Molinari, G. Zeng, and J.S. Suri Review: a state of the art review on intima-media thickness (IMT) measurement and wall segmentation techniques for carotid ultrasound Comput. Methods Prog. Biomed. 100 2010 201 221
-
(2010)
Comput. Methods Prog. Biomed.
, vol.100
, pp. 201-221
-
-
Molinari, F.1
Zeng, G.2
Suri, J.S.3
-
30
-
-
34547924050
-
Characterization of a completely user-independent algorithm for carotid artery segmentation in 2-D ultrasound images
-
S. Delsanto, F. Molinari, P. Giustetto, W. Liboni, S. Badalamenti, and J. Suri Characterization of a completely user-independent algorithm for carotid artery segmentation in 2-D ultrasound images IEEE Trans. Instrument Meas 56 2007 1265 1274
-
(2007)
IEEE Trans. Instrument Meas
, vol.56
, pp. 1265-1274
-
-
Delsanto, S.1
Molinari, F.2
Giustetto, P.3
Liboni, W.4
Badalamenti, S.5
Suri, J.6
-
31
-
-
54149096512
-
Real-time measurement system for evaluation of the carotid intima-media thickness with a robust edge operator
-
F. Faita, V. Gemignani, E. Bianchini, C. Giannarelli, L. Ghiadoni, and M. Demi Real-time measurement system for evaluation of the carotid intima-media thickness with a robust edge operator J. Ultrasound Med. 27 2008 1353 1361
-
(2008)
J. Ultrasound Med.
, vol.27
, pp. 1353-1361
-
-
Faita, F.1
Gemignani, V.2
Bianchini, E.3
Giannarelli, C.4
Ghiadoni, L.5
Demi, M.6
-
32
-
-
76449106558
-
Automatic computer-based tracings (act) in longitudinal 2-D ultrasound images using different scanners
-
F. Molinari, W. Liboni, P. Giustetto, S. Badalamenti, and J.S. Suri Automatic computer-based tracings (act) in longitudinal 2-D ultrasound images using different scanners J. Mech. Med. Biol. 09 2009 481 505
-
(2009)
J. Mech. Med. Biol.
, vol.9
, pp. 481-505
-
-
Molinari, F.1
Liboni, W.2
Giustetto, P.3
Badalamenti, S.4
Suri, J.S.5
-
33
-
-
79960371742
-
Automated carotid artery intima layer regional segmentation
-
K.M. Meiburger, F. Molinari, U. Acharya, L. Saba, P. Rodrigues, W. Liboni, A. Nicolaides, and J. Suri Automated carotid artery intima layer regional segmentation Phys. Med. Biol. 56 2011 4073 4090
-
(2011)
Phys. Med. Biol.
, vol.56
, pp. 4073-4090
-
-
Meiburger, K.M.1
Molinari, F.2
Acharya, U.3
Saba, L.4
Rodrigues, P.5
Liboni, W.6
Nicolaides, A.7
Suri, J.8
-
34
-
-
84855579414
-
Caudles-ef: Carotid automated ultrasound double line extraction system using edge flow
-
F. Molinari, K.M.G. Zeng, A. Nicolaides, and J. Suri Caudles-ef: carotid automated ultrasound double line extraction system using edge flow J. Digit. Imaging 24 2011 1059 1077
-
(2011)
J. Digit. Imaging
, vol.24
, pp. 1059-1077
-
-
Molinari, F.1
Zeng, K.M.G.2
Nicolaides, A.3
Suri, J.4
-
35
-
-
84864191643
-
Fully automated dual-snake formulation for carotid intima-media thickness measurement a new approach
-
F. Molinari, K.M. Meiburger, L. Saba, G. Zeng, U.R. Acharya, M. Ledda, A. Nicolaides, and J.S. Suri Fully automated dual-snake formulation for carotid intima-media thickness measurement a new approach J. Ultrasound Med. 31 2012 1123 1136
-
(2012)
J. Ultrasound Med.
, vol.31
, pp. 1123-1136
-
-
Molinari, F.1
Meiburger, K.M.2
Saba, L.3
Zeng, G.4
Acharya, U.R.5
Ledda, M.6
Nicolaides, A.7
Suri, J.S.8
-
36
-
-
84872036761
-
Fully automated segmentation and tracking of the intima-media thickness in ultrasound video sequences of the common carotid artery
-
D. Ilea, C. Duffy, L. Kavanagh, A. Stanton, and P. Whelan Fully automated segmentation and tracking of the intima-media thickness in ultrasound video sequences of the common carotid artery IEEE Trans. Ultrason. Ferroelectr. Freq. Control 60 2013
-
(2013)
IEEE Trans. Ultrason. Ferroelectr. Freq. Control
, vol.60
-
-
Ilea, D.1
Duffy, C.2
Kavanagh, L.3
Stanton, A.4
Whelan, P.5
-
37
-
-
84894044783
-
Integrated system for the complete segmentation of the common carotid artery bifurcation in ultrasound images
-
H. Papadopoulos, A. Andreou, L. Iliadis, I. Maglogiannis, Springer Berlin, Heidelberg
-
C. Loizou, T. Kasparis, C. Spyrou, and M. Pantziaris Integrated system for the complete segmentation of the common carotid artery bifurcation in ultrasound images H. Papadopoulos, A. Andreou, L. Iliadis, I. Maglogiannis, Artificial Intelligence Applications and Innovations, volume 412 of IFIP Advances in Information and Communication Technology 2013 Springer Berlin, Heidelberg 292 301
-
(2013)
Artificial Intelligence Applications and Innovations, Volume 412 of IFIP Advances in Information and Communication Technology
, pp. 292-301
-
-
Loizou, C.1
Kasparis, T.2
Spyrou, C.3
Pantziaris, M.4
-
39
-
-
84868157978
-
Segmentation of the common carotid intima-media complex in ultrasound images using active contours
-
S. Petroudi, C. Loizou, M. Pantziaris, and C. Pattichis Segmentation of the common carotid intima-media complex in ultrasound images using active contours IEEE Trans. Biomed. Eng. 59 2012 3060 3069
-
(2012)
IEEE Trans. Biomed. Eng.
, vol.59
, pp. 3060-3069
-
-
Petroudi, S.1
Loizou, C.2
Pantziaris, M.3
Pattichis, C.4
-
41
-
-
84873059514
-
Segmentation of the common carotid artery walls based on a frequency implementation of active contours
-
M. Bastida-Jumilla, R. Menchón-Lara, J. Morales-Sánchez, R. Verdú-Monedero, J. Larrey-Ruiz, and J. Sancho-Gómez Segmentation of the common carotid artery walls based on a frequency implementation of active contours J. Digit. Imaging 26 2013 129 139
-
(2013)
J. Digit. Imaging
, vol.26
, pp. 129-139
-
-
Bastida-Jumilla, M.1
Menchón-Lara, R.2
Morales-Sánchez, J.3
Verdú-Monedero, R.4
Larrey-Ruiz, J.5
Sancho-Gómez, J.6
-
42
-
-
76749109541
-
Automatic localization of intimal and adventitial carotid artery layers with noninvasive ultrasound: A novel algorithm providing scan quality control
-
A. Rossi, P. Brands, and A. Hoeks Automatic localization of intimal and adventitial carotid artery layers with noninvasive ultrasound: a novel algorithm providing scan quality control Ultrasound Med. Biol. 36 2010 467 479
-
(2010)
Ultrasound Med. Biol.
, vol.36
, pp. 467-479
-
-
Rossi, A.1
Brands, P.2
Hoeks, A.3
|