메뉴 건너뛰기




Volumn 11, Issue 6, 2007, Pages 661-667

An integrated system for the segmentation of atherosclerotic carotid plaque

Author keywords

Atherosclerosis; Carotid plaque; Snakes; Ultrasound imaging

Indexed keywords

CARDIOVASCULAR SYSTEM; DIAGNOSIS; IMAGE SEGMENTATION;

EID: 36349029691     PISSN: 10897771     EISSN: None     Source Type: Journal    
DOI: 10.1109/TITB.2006.890019     Document Type: Article
Times cited : (95)

References (37)
  • 1
    • 0035109536 scopus 로고    scopus 로고
    • Atherosclerotic enlargement of the human abdominal aorta
    • C. K. Zarins, C. Xu, and S. Glagov, "Atherosclerotic enlargement of the human abdominal aorta," Atherosclerosis, vol. 155, no. 1, pp. 157-164, 2001.
    • (2001) Atherosclerosis , vol.155 , Issue.1 , pp. 157-164
    • Zarins, C.K.1    Xu, C.2    Glagov, S.3
  • 2
    • 0028091769 scopus 로고    scopus 로고
    • ACAS clinical advisory, Carotid endarterectomy forpatients with asymptomatic internal carotid artery stenosis, Stroke, 25, no. 12, pp. 2523-2524, 1994.
    • ACAS clinical advisory, "Carotid endarterectomy forpatients with asymptomatic internal carotid artery stenosis," Stroke, vol. 25, no. 12, pp. 2523-2524, 1994.
  • 3
    • 0028938324 scopus 로고    scopus 로고
    • Endarterectomy for asymptomatic carotid stenosis
    • Executive committee for the asymptomatic carotid atherosclerosis study
    • Executive committee for the asymptomatic carotid atherosclerosis study, "Endarterectomy for asymptomatic carotid stenosis," J. Am. Med. Assoc., vol. 273, pp. 1421-1428, 2002.
    • (2002) J. Am. Med. Assoc , vol.273 , pp. 1421-1428
  • 5
    • 4544220683 scopus 로고    scopus 로고
    • A. Hamou and M. El-Sakka, A novel segmentation technique for carotid ultrasound images, in Proc. Int. Conf. Acoust. Speech Signal Process. (ICASSP), 2004, pp. III-521-III-524.
    • A. Hamou and M. El-Sakka, "A novel segmentation technique for carotid ultrasound images," in Proc. Int. Conf. Acoust. Speech Signal Process. (ICASSP), 2004, pp. III-521-III-524.
  • 6
    • 4944231471 scopus 로고    scopus 로고
    • A novel morphological-based carotid artery contour extraction
    • May 2-5
    • A. R. Abdel-Dayen and M. El-Sakka, "A novel morphological-based carotid artery contour extraction," in Proc. Can. Conf. Electr. Comput. Eng. May 2-5, 2004, vol. 4, pp. 1873-1876.
    • (2004) Proc. Can. Conf. Electr. Comput. Eng , vol.4 , pp. 1873-1876
    • Abdel-Dayen, A.R.1    El-Sakka, M.2
  • 7
    • 0033862587 scopus 로고    scopus 로고
    • Segmentation of carotid artery in ultrasound images: Method development and evaluation technique
    • Aug
    • F. Mao, J. Gill, D. Downey, and A. Fenster, "Segmentation of carotid artery in ultrasound images: Method development and evaluation technique," Med. Phys., vol. 27, no. 8, pp. 1-10, Aug. 2000.
    • (2000) Med. Phys , vol.27 , Issue.8 , pp. 1-10
    • Mao, F.1    Gill, J.2    Downey, D.3    Fenster, A.4
  • 10
    • 36348963907 scopus 로고    scopus 로고
    • Segmentation of ulcerated plaque: A semi-automatic method for tracking the progression of carotid atherosclerosis
    • Chicago, IL
    • J. D. Gill, H. M. Ladak, D. A. Steinman, and A. Fenster, "Segmentation of ulcerated plaque: A semi-automatic method for tracking the progression of carotid atherosclerosis," in Proc. World Congr. Med. Phys. Biomed. Eng., Chicago, IL, 2000, pp. 1-4, 2000.
    • (2000) Proc. World Congr. Med. Phys. Biomed. Eng , pp. 1-4
    • Gill, J.D.1    Ladak, H.M.2    Steinman, D.A.3    Fenster, A.4
  • 11
    • 0032216603 scopus 로고    scopus 로고
    • Tissue characterization in intravascular ultrasound images
    • Dec
    • X. Zhang, C. R. McKay, and M. Sonka, "Tissue characterization in intravascular ultrasound images," IEEE Trans. Med. Imag., vol. 17, no. 6, pp. 889-899, Dec. 1998.
    • (1998) IEEE Trans. Med. Imag , vol.17 , Issue.6 , pp. 889-899
    • Zhang, X.1    McKay, C.R.2    Sonka, M.3
  • 12
    • 0344823962 scopus 로고    scopus 로고
    • Intravascular ultrasound image segmentation: A fast-marching method
    • Proc. MICCAI
    • M. R. Cardinal, J. Meunier, G. Soulez, E. Thérasse, and G. Cloutier, "Intravascular ultrasound image segmentation: A fast-marching method," in Proc. MICCAI, LNCS 2879, 2003, pp. 432-439.
    • (2003) LNCS , vol.2879 , pp. 432-439
    • Cardinal, M.R.1    Meunier, J.2    Soulez, G.3    Thérasse, E.4    Cloutier, G.5
  • 13
    • 2542430314 scopus 로고    scopus 로고
    • Fully automatic luminal contour segmentation in intracoronary ultrasound imaging: A statistical approach
    • May
    • E. Brusseau, C. L. De Korte, F. Mastick, J. Schaar, and A. F. W. Van der Steen, "Fully automatic luminal contour segmentation in intracoronary ultrasound imaging: A statistical approach," IEEE Trans. Med. Imag. vol. 23, no. 5, pp. 554-566, May 2004.
    • (2004) IEEE Trans. Med. Imag , vol.23 , Issue.5 , pp. 554-566
    • Brusseau, E.1    De Korte, C.L.2    Mastick, F.3    Schaar, J.4    Van der Steen, A.F.W.5
  • 14
    • 23844501699 scopus 로고    scopus 로고
    • Multi-dimensional segmentation of coronary intravascular ultrasound images using knowledge-based methods
    • M. E. Olszewski, A. Wahle, S. C. Vigmostad, and M. Sonka, "Multi-dimensional segmentation of coronary intravascular ultrasound images using knowledge-based methods," Proc SPIE, vol. 5747, pp. 496-504, 2005.
    • (2005) Proc SPIE , vol.5747 , pp. 496-504
    • Olszewski, M.E.1    Wahle, A.2    Vigmostad, S.C.3    Sonka, M.4
  • 15
    • 0035158999 scopus 로고    scopus 로고
    • Atherosclerotic plaque segmentation at human carotid artery based on multiple contrast weighting MR images
    • D. Xu, J.-N. Hwang, and C. Yuan, "Atherosclerotic plaque segmentation at human carotid artery based on multiple contrast weighting MR images," IEEE ICIP 2001, vol. 2, pp. 849-852.
    • (2001) IEEE ICIP , vol.2 , pp. 849-852
    • Xu, D.1    Hwang, J.-N.2    Yuan, C.3
  • 16
    • 0036916146 scopus 로고    scopus 로고
    • Estimation of carotid atherosclerotic plaque volume in vivo magnetic resonance images
    • G. J. Adams, G. W. Vick, C. M. Ballantyne, W. Insull, and J. D. Morrisett, "Estimation of carotid atherosclerotic plaque volume in vivo magnetic resonance images," in Proc. EMBS/BMES Conf., 2002, pp. 1072-1073.
    • (2002) Proc. EMBS/BMES Conf , pp. 1072-1073
    • Adams, G.J.1    Vick, G.W.2    Ballantyne, C.M.3    Insull, W.4    Morrisett, J.D.5
  • 18
    • 0026741340 scopus 로고
    • A fast algorithm for active contour and curvature estimation
    • D. Williams and M. Shah, "A fast algorithm for active contour and curvature estimation," GVCIP: Imag. Understanding, vol. 55, no. 1, pp. 14-26, 1992.
    • (1992) GVCIP: Imag. Understanding , vol.55 , Issue.1 , pp. 14-26
    • Williams, D.1    Shah, M.2
  • 20
    • 0029404006 scopus 로고
    • Deformable contours: Modeling and extraction
    • PAMI, Nov
    • K. F. Lai and R. T. Chin, "'Deformable contours: Modeling and extraction," IEEE Trans. PAMI, vol. 17, no. 11, pp. 1084-1090, Nov. 1995.
    • (1995) IEEE Trans , vol.17 , Issue.11 , pp. 1084-1090
    • Lai, K.F.1    Chin, R.T.2
  • 21
    • 0032291262 scopus 로고    scopus 로고
    • Generalized gradient vector flow external forces for active contours
    • C. Xu and J. Prince, "Generalized gradient vector flow external forces for active contours," Signal Process., vol. 71, pp. 131-139, 1998.
    • (1998) Signal Process , vol.71 , pp. 131-139
    • Xu, C.1    Prince, J.2
  • 22
    • 36348979550 scopus 로고    scopus 로고
    • Performance evaluation of active contour models for carotid plaque segmentation
    • Prague, Czech Republic, Nov. 20-25
    • C. P. Loizou, C. S. Pattichis, M. Pantziaris, and A. Nicolaides, "Performance evaluation of active contour models for carotid plaque segmentation," in Proc. EMBEC 2005, Prague, Czech Republic, Nov. 20-25, 2005, vol 11, no. 1, p. 6.
    • (2005) Proc. EMBEC 2005 , vol.11 , Issue.1 , pp. 6
    • Loizou, C.P.1    Pattichis, C.S.2    Pantziaris, M.3    Nicolaides, A.4
  • 24
    • 34047169396 scopus 로고    scopus 로고
    • Ultrasound imaging in the analysis of carotid plaque morphology for the assessment of stroke
    • J. S. Suri, C. Yuan, D. L. Wilson, and S. Laxminarayan, Eds. Amsterdam, The Netherlands: IOS Press
    • E. Kyriakou, M. S. Pattichis, C. I. Christodoulou, C. S. Pattichis, S. Kakkos, M. Griffin, and A. Nicolaides, "Ultrasound imaging in the analysis of carotid plaque morphology for the assessment of stroke," in Plaque Imaging: Pixel to Molecular Level, J. S. Suri, C. Yuan, D. L. Wilson, and S. Laxminarayan, Eds. Amsterdam, The Netherlands: IOS Press, 2005, pp. 241-275.
    • (2005) Plaque Imaging: Pixel to Molecular Level , pp. 241-275
    • Kyriakou, E.1    Pattichis, M.S.2    Christodoulou, C.I.3    Pattichis, C.S.4    Kakkos, S.5    Griffin, M.6    Nicolaides, A.7
  • 25
    • 0031726069 scopus 로고    scopus 로고
    • The effect of B-mode ultrasonic image standardization of the echodensity of symptomatic and asymptomatic carotid bifurcation plaque
    • T. Elatrozy, A. Nicolaides, T. Tegos, A. Zarka, M. Griffin, and M. Sabetai, "The effect of B-mode ultrasonic image standardization of the echodensity of symptomatic and asymptomatic carotid bifurcation plaque," Int. Angiol., vol. 17, no. 3, pp. 179-186, 1998.
    • (1998) Int. Angiol , vol.17 , Issue.3 , pp. 179-186
    • Elatrozy, T.1    Nicolaides, A.2    Tegos, T.3    Zarka, A.4    Griffin, M.5    Sabetai, M.6
  • 26
    • 0018998148 scopus 로고
    • Digital image enhancement and noise filtering by use of local statistics
    • J. S. Lee, "Digital image enhancement and noise filtering by use of local statistics," IEEE Trans. Pattern Anal. Mach. Intell., vol. PAMI-2, no. 2, pp. 165-168, 1980.
    • (1980) IEEE Trans. Pattern Anal. Mach. Intell , vol.PAMI-2 , Issue.2 , pp. 165-168
    • Lee, J.S.1
  • 28
    • 36348983013 scopus 로고    scopus 로고
    • Ultrasound image analysis of the carotid artery,
    • Ph.D. dissertation, Kingston Univ, London, U.K
    • C. P. Loizou, "Ultrasound image analysis of the carotid artery," Ph.D. dissertation, Kingston Univ., London, U.K., 2005.
    • (2005)
    • Loizou, C.P.1
  • 29
    • 0018079655 scopus 로고
    • Basic principles of ROC analysis
    • C. Metz, "Basic principles of ROC analysis," Semin. Nucl. Medic. vol. 8, pp. 283-298, 1978.
    • (1978) Semin. Nucl. Medic , vol.8 , pp. 283-298
    • Metz, C.1
  • 30
    • 33645066726 scopus 로고
    • Large sample standard errors of kappa and weighted kappa
    • J. L. Fleiss, J. Cohen, and B.S. Everitt, "Large sample standard errors of kappa and weighted kappa," Psychol. Bull., vol. 72, no. 5, pp. 323-327, 1969.
    • (1969) Psychol. Bull , vol.72 , Issue.5 , pp. 323-327
    • Fleiss, J.L.1    Cohen, J.2    Everitt, B.S.3
  • 31
    • 0022927129 scopus 로고
    • A coefficient of agreement as a measure of thematic classification accuracy
    • G. H. Rosenfield and K. Fitzpatrick Lins, "A coefficient of agreement as a measure of thematic classification accuracy," Photogramm. Eng. Remote Sens., vol. 52, no. 2, pp. 223-227, 1986.
    • (1986) Photogramm. Eng. Remote Sens , vol.52 , Issue.2 , pp. 223-227
    • Rosenfield, G.H.1    Fitzpatrick Lins, K.2
  • 33
  • 34
    • 24944478100 scopus 로고    scopus 로고
    • Effect of image normalization on carotid plaque classification and the risk of ipsilateral hemispheric events: Results from the asymptomatic carotid stenosis and risk of stroke study
    • A. N. Nicolaides, et al., "Effect of image normalization on carotid plaque classification and the risk of ipsilateral hemispheric events: Results from the asymptomatic carotid stenosis and risk of stroke study," Vascular, vol. 1, no. 4, pp. 211-221, 2005.
    • (2005) Vascular , vol.1 , Issue.4 , pp. 211-221
    • Nicolaides, A.N.1
  • 35
    • 0036721081 scopus 로고    scopus 로고
    • Real-time speckle reduction and coherence enhancement in ultrasound imaging via nonlinear anisotropic diffusion
    • Sep
    • K. Abd Elmonien, A.-B. Youssef, and Y. Kadah, "Real-time speckle reduction and coherence enhancement in ultrasound imaging via nonlinear anisotropic diffusion," IEEE Trans. Biomed. Eng., vol. 49, no. 9, pp. 997-1014, Sep. 2002.
    • (2002) IEEE Trans. Biomed. Eng , vol.49 , Issue.9 , pp. 997-1014
    • Abd Elmonien, K.1    Youssef, A.-B.2    Kadah, Y.3
  • 36
    • 33746609018 scopus 로고    scopus 로고
    • Statistical strategy for anisotropic adventitia modeling in IVUS
    • Jun
    • D. Gil, A. Hernandez, J. Mauri, and P. Radeva, "Statistical strategy for anisotropic adventitia modeling in IVUS," IEEE Trans. Med. Imag. vol. 25, no. 6, pp. 768-778, Jun. 2006.
    • (2006) IEEE Trans. Med. Imag , vol.25 , Issue.6 , pp. 768-778
    • Gil, D.1    Hernandez, A.2    Mauri, J.3    Radeva, P.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.