메뉴 건너뛰기




Volumn 20, Issue 4, 2014, Pages 333-338

10kVp rule - An anthropomorphic pelvis phantom imaging study using a CR system: Impact on image quality and effective dose using AEC and manual mode

Author keywords

10kVp rule; AEC; CR; Effective dose; Perceptual image quality

Indexed keywords

ARTICLE; AUTOMATION; COMPUTER ASSISTED RADIOGRAPHY; CONTROLLED STUDY; FORCED CHOICE METHOD; HUMAN; IMAGE DISPLAY; IMAGE QUALITY; IMAGING PHANTOM; IMAGING SOFTWARE; RADIATION RESPONSE; X RAY GENERATOR; X RAY TUBE;

EID: 84908540234     PISSN: 10788174     EISSN: 15322831     Source Type: Journal    
DOI: 10.1016/j.radi.2014.04.007     Document Type: Article
Times cited : (22)

References (13)
  • 1
    • 81255169128 scopus 로고    scopus 로고
    • Management of patient dose in radiology in the UK
    • [Internet], [cited 26.03.12]. Available from:
    • Martin C.J. Management of patient dose in radiology in the UK. Radiat Prot Dosim 2011 Nov, 147(3):355-372. [Internet], [cited 26.03.12]. Available from:. http://www.ncbi.nlm.nih.gov/pubmed/22008582.
    • (2011) Radiat Prot Dosim , vol.147 , Issue.3 , pp. 355-372
    • Martin, C.J.1
  • 2
    • 84880581888 scopus 로고    scopus 로고
    • Anthropomorphic chest phantom imaging - the potential for dose creep in computed radiography
    • [Internet], [cited 18.11.13]. Available from:
    • Ma W.K., Hogg P., Tootell a, Manning D., Thomas N., Kane T., et al. Anthropomorphic chest phantom imaging - the potential for dose creep in computed radiography. Radiography 2013 Aug, 19(3):207-211. [Internet], [cited 18.11.13]. Available from:. http://linkinghub.elsevier.com/retrieve/pii/S1078817413000424.
    • (2013) Radiography , vol.19 , Issue.3 , pp. 207-211
    • Ma, W.K.1    Hogg, P.2    Tootell, A.3    Manning, D.4    Thomas, N.5    Kane, T.6
  • 4
    • 84866762386 scopus 로고    scopus 로고
    • Optimization of patient radiation protection in pelvic X-ray examination in Ghana
    • [Internet], Available from:
    • Ofori E.K., Antwi W.K., Scutt D.N., Ward M. Optimization of patient radiation protection in pelvic X-ray examination in Ghana. JAppl Clin Med Phys 2012 Jan, 13(4):3719. [Internet], Available from:. http://www.ncbi.nlm.nih.gov/pubmed/22766943.
    • (2012) JAppl Clin Med Phys , vol.13 , Issue.4 , pp. 3719
    • Ofori, E.K.1    Antwi, W.K.2    Scutt, D.N.3    Ward, M.4
  • 6
    • 0030723703 scopus 로고    scopus 로고
    • Modern day film-screen combinations do not obey conventional exposure rules
    • [Internet], Available from:
    • Brennan P.C., McCandless N., Masterson J. Modern day film-screen combinations do not obey conventional exposure rules. Radiography 1997, 3(4):305-310. [Internet], Available from:. http://www.scopus.com/inward/record.url?eid=2-s2.0-0030723703%26partnerID=40%26md5=1ba8e96402a7342a3f8b01918945a2cd.
    • (1997) Radiography , vol.3 , Issue.4 , pp. 305-310
    • Brennan, P.C.1    McCandless, N.2    Masterson, J.3
  • 7
    • 84880617734 scopus 로고    scopus 로고
    • Fact or fiction: an analysis of the 10 kVp "rule" in computed radiography
    • [Internet], [cited 16.11.13]. Available from:
    • Allen E., Hogg P., Ma W.K., Szczepura K. Fact or fiction: an analysis of the 10 kVp "rule" in computed radiography. Radiography 2013 Aug, 19(3):223-227. [Internet], [cited 16.11.13]. Available from:. http://linkinghub.elsevier.com/retrieve/pii/S1078817413000497.
    • (2013) Radiography , vol.19 , Issue.3 , pp. 223-227
    • Allen, E.1    Hogg, P.2    Ma, W.K.3    Szczepura, K.4
  • 8
    • 80053488769 scopus 로고    scopus 로고
    • Visual perception studies and observer models in medical imaging
    • [Internet]. Elsevier Inc., [cited 18.11.13]. Available from:
    • Burgess A.E. Visual perception studies and observer models in medical imaging. Semin Nucl Med 2011 Nov, 41(6):419-436. [Internet]. Elsevier Inc., [cited 18.11.13]. Available from:. http://www.ncbi.nlm.nih.gov/pubmed/21978445.
    • (2011) Semin Nucl Med , vol.41 , Issue.6 , pp. 419-436
    • Burgess, A.E.1
  • 10
    • 84908524181 scopus 로고    scopus 로고
    • [Internet] [cited 1BC Aug 27]. Available from:
    • The Phantom Laboratory Sectional lower Torso SK250 [Internet] [cited 1BC Aug 27]. Available from:. http://www.phantomlab.com/library/pdf/sectional_SK250DS.pdf.
    • Sectional lower Torso SK250
  • 13
    • 17844408736 scopus 로고    scopus 로고
    • Assessment of display performance for medical imaging systems: executive summary of AAPM TG18 report
    • [Internet], [cited 21.11.13]. Available from:
    • Samei E., Badano A., Chakraborty D., Compton K., Cornelius C., Corrigan K., et al. Assessment of display performance for medical imaging systems: executive summary of AAPM TG18 report. Med Phys 2005, 32(4):1205. [Internet], [cited 21.11.13]. Available from:. http://link.aip.org/link/MPHYA6/v32/i4/p1205/s1%26Agg=doi.
    • (2005) Med Phys , vol.32 , Issue.4 , pp. 1205
    • Samei, E.1    Badano, A.2    Chakraborty, D.3    Compton, K.4    Cornelius, C.5    Corrigan, K.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.