메뉴 건너뛰기




Volumn 19, Issue 3, 2013, Pages 223-227

Fact or fiction: An analysis of the 10kVp 'rule' in computed radiography

Author keywords

10kVp rule; Effective dose; Image quality

Indexed keywords

ARTICLE; COMPUTER ASSISTED RADIOGRAPHY; COMPUTER PROGRAM; CONTROLLED STUDY; DIGITAL RADIOGRAPHY; DOSE RESPONSE; DOSIMETRY; ELECTRIC POTENTIAL; HUMAN; IMAGE ANALYSIS; IMAGE QUALITY; MAJOR CLINICAL STUDY; PHANTOM; PRIORITY JOURNAL; RADIATION DOSE; THORAX RADIOGRAPHY; X RAY TUBE;

EID: 84880617734     PISSN: 10788174     EISSN: 15322831     Source Type: Journal    
DOI: 10.1016/j.radi.2013.05.003     Document Type: Article
Times cited : (24)

References (15)
  • 1
    • 0348246078 scopus 로고    scopus 로고
    • The AAPM/RSNA physics tutorial for residents. Clinical applications of basic X-ray physics principles
    • Schueler B.A. The AAPM/RSNA physics tutorial for residents. Clinical applications of basic X-ray physics principles. Radiographics 1998, 18:731-744.
    • (1998) Radiographics , vol.18 , pp. 731-744
    • Schueler, B.A.1
  • 7
    • 0030723703 scopus 로고    scopus 로고
    • Modern day film-screen combinations do not obey conventional exposure rules
    • Brennan P.C., McCandless N., Masterson J. Modern day film-screen combinations do not obey conventional exposure rules. Radiography 1997, 3(4):305-310.
    • (1997) Radiography , vol.3 , Issue.4 , pp. 305-310
    • Brennan, P.C.1    McCandless, N.2    Masterson, J.3
  • 8
    • 84880576615 scopus 로고    scopus 로고
    • Kyoto Kagaku Ltd. Multipurpose chest phantom N1 "LUNGMAN" [last accessed 18.05.13].
    • Kyoto Kagaku Ltd. Multipurpose chest phantom N1 "LUNGMAN" [last accessed 18.05.13]. http://www.kyotokagaku.com/products/detail03/ph-1.html.
  • 9
    • 84880581888 scopus 로고    scopus 로고
    • Anthropomorphic chest phantom imaging - the potential for dose creep in computed radiography
    • Ma W.K., Hogg P., Tootell A., Manning D., Thomas N., Kane T., et al. Anthropomorphic chest phantom imaging - the potential for dose creep in computed radiography. Radiography 2013, 19(3):207-211.
    • (2013) Radiography , vol.19 , Issue.3 , pp. 207-211
    • Ma, W.K.1    Hogg, P.2    Tootell, A.3    Manning, D.4    Thomas, N.5    Kane, T.6
  • 12
    • 80053488769 scopus 로고    scopus 로고
    • Visual perception studies and observer models in medical imaging
    • Burgess A.E. Visual perception studies and observer models in medical imaging. Seminars in Nuclear Medicine 2011, 41(6):419-436.
    • (2011) Seminars in Nuclear Medicine , vol.41 , Issue.6 , pp. 419-436
    • Burgess, A.E.1
  • 13
    • 84880641008 scopus 로고    scopus 로고
    • Software for image quality evaluation using a forced choice method presented at the UKRC Manchester June 25-27
    • Hogg P and Blindell P. Software for image quality evaluation using a forced choice method presented at the UKRC Manchester June 25-27; 2012.
    • (2012)
    • Hogg, P.1    Blindell, P.2
  • 14
    • 0003892096 scopus 로고    scopus 로고
    • Office of Official Publications of the European Communities, Luxembourg, J.H.E. Carmichael, C. Maccia, B.M. Moores, J.W. Oestmann, H. Schibilla, D. Teunen (Eds.)
    • Commission of the European communities European guidelines on quality criteria for diagnostic radiographic images 1996, Office of Official Publications of the European Communities, Luxembourg. J.H.E. Carmichael, C. Maccia, B.M. Moores, J.W. Oestmann, H. Schibilla, D. Teunen (Eds.).
    • (1996) Commission of the European communities European guidelines on quality criteria for diagnostic radiographic images


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.